Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSULATED STRUCTURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Thermionic fuel element technology status

The results of research, conducted between the mid-1960s and 1973, on the multiconverter thermionic fuel elements (TFEs) that comprise the reactor core of an SP-100 thermionic reactor system are presented. Fueled-emitter technology, insulator technology and cell and TFE assembly technology of the prototypical TFEs which were tested in-pile and out-of-pile during these years are described. The proto-TFEs have demonstrated reproducible performance within 5 percent and no premature failures within the 1.5 yr of operation (with projected 3-yr lifetimes). The two primary life-limiting factors had been identified as thermionic emitter dimensional increase due to interactions with the fuel and electrical insulator structural damage from fast neutrons. Multiple options for extending TFE lifetimes to 7 yr or longer are available and will be investigated in the 1984-1985 SP-100 program for resolution of critical technology issues. Design diagrams and test graphs are included.

Holland, J. W.↗

Eutelsat 2: SAR-10009 nickel-hydrogen battery

The topics are presented in viewgraph form and include SAR-10009 design features, specific energy, analyses and testing, redundant structural insulation, electronics, corrosion protection, battery cell life cycle tests, and spacecraft launches.

Miller, Lee↗

High-Resolution Inspection of the Space Shuttle External Tank Spray-on-Foam Insulation (SOFI) using Focused Millimeter Waves at D-Band (150 GHz)

Space Shuttle Columbia's catastrophic failure has been attributed to a piece of spray-on-foam insulation (SOFI) that was dislodged from the external tank and struck the leading edge of the left wing. A piece of SOFI was also dislodged in the recent Space Shuttle Discovery's flight. Clearly, there is a great and urgent need to inspect the external tank SOFI and other similar insulating structures (including the acreage heat tile) in a reliable and robust fashion. In the past two years, millimeter wave nondestructive testing methods, using both real and synthetic focusing techniques, have shown great potential for this purpose. Recently obtained real-focused images from several different and complex SOFI panels have demonstrated the utility of these methods as being viable, robust, repeatable, simple, portable and effective. D-band frequency range which covers a frequency spectrum of 110- 170 GHz is well-suited for this purpose given the nature of the foam which causes significant scattering at much higher frequencies. This paper presents the results of using continuous-wave (CW) reflectometry conducted on several typical and complex SOFI panes at 150 GHz.

Kharkovsky, S.↗

Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Abstract: NASA is currently investigating methods to reduce the boil-off rate on large cryogenic upper stages. Two such methods to reduce the total heat load on existing upper stages are vapor cooling of the cryogenic tank support structure and integration of thick multilayer insulation systems to the upper stage of a launch vehicle. Previous efforts have flown a 2-layer MLI blanket and shown an improved thermal performance, and other efforts have ground-tested blankets up to 70 layers thick on tanks with diameters between 2 3 meters. However, thick multilayer insulation installation and testing in both thermal and structural modes has not been completed on a large scale tank. Similarly, multiple vapor cooled shields are common place on science payload helium dewars; however, minimal effort has gone into using boil-off to intercept heat on large structural surfaces associated with rocket stages. A majority of the vapor cooling effort focuses on metallic cylinders called skirts, which are the most common structural components for launch vehicles. In order to provide test data for comparison with analytical models, a 4 meter diameter test tank and assembly is currently being designed to include skirt structural systems with integral vapor cooling. In order to give a more representative result for actual applications, the technologies will be designed for an 8.4 m and scaled down to a 4 meter tank. In order to prove that the insulation system and vapor cooling attachment methods are structurally sound, acoustic testing will also be performed on the system. The test tank with insulation and vapor cooled shield installed will be tested thermally in the B2 test facility at NASAs Plum Brook Station both before and after being vibration tested at Plum Brooks Space Power Facility.

Johnson, Wesley↗

Space Tug Point Design Study. Volume 3: Design Definition. Part 2: Insulation, Meteoroid Protection, Structures, Mass Properties, GSE, Reliability and Safety

A study was conducted to determine the configuration and performance of a space tug. Detailed descriptions of the insulation, meteoroid protection, primary structure, and ground support equipment are presented. Technical assessments leading to the concept selection are analyzed. The tug mass properties, reliability, and safety assessments are included.

Source record↗

Technology Demonstration Mission (TDM) evolvable Cryogenics (eCryo) Project Structural Heat Intercept, Insulation and Vibration Evaluation Rig (SHIIVER) Diode Rake Assembly and Installation

NASA designed, assembled and installed a temperature diode rake into the SHIIVER test article for use of measuring liquid and gaseous hydrogen temperatures. Several special steps were taken to ensure that fluid temperatures were measured as opposed to structural temperatures. This document outlines design practices and methodologies that have become standard practice at Glenn Research Center to ensure the measurement of fluid temperatures for cryogenic systems research.

Cryogenic Fluid Management↗

LaF3 insulators for MIS structures

Thin films of LaF3 deposited on Si or GaAs substrates have been observed to form blocking contacts with very high capacitances. This results in comparatively hysteresis-free and sharp C-V (capacitance-voltage) characteristics for MIS structures. Such structures have been used to study the interface states of GaAs with increased resolution and to construct improved photocapacitive infrared detectors.

Sher, A.↗

Structural analysis of a thermal insulation retainer assembly

In January 1989 an accident occurred in the National Transonic Facility wind tunnel at NASA Langley Research Center that was believed to be caused by the failure of a thermal insulation retainer. A structural analysis of this retainer assembly was performed in order to understand the possible failure mechanisms. Two loading conditions are important and were considered in the analysis. The first is the centrifugal force due to the fact that this retainer is located on the fan drive shaft. The second loading is a differential temperature between the retainer assembly and the underlying shaft. Geometrically nonlinear analysis is required to predict the stiffness of this component and to account for varying contact regions between various components in the assembly. High, local stresses develop in the band part of the assembly near discontinuities under both the centrifugal and thermal loadings. The presence of an aluminum ring during a portion of the part's operating life was found to increase the stresses in other regions of the band. Under the centrifugal load, high bending stresses develop near the intersection of the band with joints in the assembly. These high bending stresses are believed to be the most likely cause for failure of the assembly.

Greene, William H.↗

Mechanical Attachment of Reusable Surface Insulation to Space Shuttle Primary Structure

Three methods of attaching surface insulation tiles to shuttle primary structure have been proposed: direct bond, mechanical attachment, and subpanels with standoffs. The direct bond approach is lightweight but is difficult to refurbish and inspect. The subpanel approach is heavier but allows for easy refurbishment since subpanels are easily removed and replaced. The mechanical attachment approach allows easy refurbishment and inspection and is lightweight when an efficient insulator is used between surface insulation tiles and primary structure.

Fleck, R. W.↗

The Structural Heat Intercept-Insulation-Vibration Evaluation Rig (SHIVER)

NASA is currently investigating methods to reduce the boil-off rate on large cryogenic upper stages. Two such methods to reduce the total heat load on existing upper stages are vapor cooling of the cryogenic tank support structure and integration of thick multilayer insulation systems to the upper stage of a launch vehicle. Previous efforts have flown a 2-layer MLI blanket and shown an improved thermal performance, and other efforts have ground-tested blankets up to 70 layers thick on tanks with diameters between 2 3 meters. However, thick multilayer insulation installation and testing in both thermal and structural modes has not been completed on a large scale tank. Similarly, multiple vapor cooled shields are common place on science payload helium dewars; however, minimal effort has gone into intercepting heat on large structural surfaces associated with rocket stages. A majority of the vapor cooling effort focuses on metallic cylinders called skirts, which are the most common structural components for launch vehicles. In order to provide test data for comparison with analytical models, a representative test tank is currently being designed to include skirt structural systems with integral vapor cooling. The tank is 4 m in diameter and 6.8 m tall to contain 5000 kg of liquid hydrogen. A multilayer insulation system will be designed to insulate the tank and structure while being installed in a representative manner that can be extended to tanks up to 10 meters in diameter. In order to prove that the insulation system and vapor cooling attachment methods are structurally sound, acoustic testing will also be performed on the system. The test tank with insulation and vapor cooled shield installed will be tested thermally in the B2 test facility at NASAs Plumbrook Station both before and after being vibration tested at Plumbrooks Space Power Facility.

Cryogenic Fluid Management↗

Solar-Thermal Engine Testing

A solar-thermal engine serves as a high-temperature solar-radiation absorber, heat exchanger, and rocket nozzle. collecting concentrated solar radiation into an absorber cavity and transferring this energy to a propellant as heat. Propellant gas can be heated to temperatures approaching 4,500 F and expanded in a rocket nozzle, creating low thrust with a high specific impulse (I(sub sp)). The Shooting Star Experiment (SSE) solar-thermal engine is made of 100 percent chemical vapor deposited (CVD) rhenium. The engine 'module' consists of an engine assembly, propellant feedline, engine support structure, thermal insulation, and instrumentation. Engine thermal performance tests consist of a series of high-temperature thermal cycles intended to characterize the propulsive performance of the engines and the thermal effectiveness of the engine support structure and insulation system. A silicone-carbide electrical resistance heater, placed inside the inner shell, substitutes for solar radiation and heats the engine. Although the preferred propellant is hydrogen, the propellant used in these tests is gaseous nitrogen. Because rhenium oxidizes at elevated temperatures, the tests are performed in a vacuum chamber. Test data will include transient and steady state temperatures on selected engine surfaces, propellant pressures and flow rates, and engine thrust levels. The engine propellant-feed system is designed to Supply GN2 to the engine at a constant inlet pressure of 60 psia, producing a near-constant thrust of 1.0 lb. Gaseous hydrogen will be used in subsequent tests. The propellant flow rate decreases with increasing propellant temperature, while maintaining constant thrust, increasing engine I(sub sp). In conjunction with analytical models of the heat exchanger, the temperature data will provide insight into the effectiveness of the insulation system, the structural support system, and the overall engine performance. These tests also provide experience on operational aspects of the engine and associated subsystems, and will include independent variation of both steady slate heat-exchanger temperature prior to thrust operation and nitrogen inlet pressure (flow rate) during thrust operation. Although the Shooting Star engines were designed as thermal-storage engines to accommodate mission parameters, they are fully capable of operating as scalable, direct-gain engines. Tests are conducted in both operational modes. Engine thrust and propellant flow rate will be measured and thereby I(sub sp). The objective of these tests is to investigate the effectiveness of the solar engine as a heat exchanger and a rocket. Of particular interest is the effectiveness of the support structure as a thermal insulator, the integrity of both the insulation system and the insulation containment system, the overall temperature distribution throughout the engine module, and the thermal power required to sustain steady state fluid temperatures at various flow rates.

Tucker, Stephen↗

Thermal Insulation Performance of Textile Structures for Spacesuit Applications at Martian Pressure and Temperature

Protection of astronauts from the extreme temperatures in the space environment has been provided in the past using multi-layer insulation in ultra-high vacuum environments of low earth orbit and the lunar surface. For planetary environments with residual gas atmospheres such as Mars with ambient pressures between 8 to 14 hPa (8 to 14 mbar), new protection techniques are required because of the dominating effect of the ambient gas on heat loss through the insulation. At Mars ambient pressure levels, the heat loss can be excessive at expected suit external temperatures of 172 K with state-of-the-art suit insulation, requiring an active heat source and its accompanying weight and volume penalties. Micro-fibers have been identified as one potential structure to reduce the heat losses, but existing fundamental data on fiber heat transfer at low pressure is lacking for integrated fabric structures. This baseline study presents insulation performance test data at different pressures and fabric loads for selected polyesters and aramids as a function of fiber density, fiber diameter, fabric density, and fabric construction. A set of trend data of thermal conductivity versus ambient pressure is presented for each fiber and fabric construction design to identify the design effects on thermal conductivity at various ambient pressures, and to select a fiber and fabric design for further development as a suit insulation. The trend data also shows the pressure level at which thermal conductivity approaches a minimum, below which no further improvement is possible for a given fiber and fabric design. The pressure levels and resulting thermal conductivities from the trend data can then be compared to the ambient pressure at a planetary surface, Mars for example, to determine if a particular fiber and fabric design has potential as a suit insulation.

Orndoff, Evelyne↗

Diamondlike carbon films on semiconductors for insulated-gate technology

MIS structures are fabricated on p-type InP, GaAs, and Si substrated by direct ionization of 25-percent CH4 in Ar and ion-beam deposition of 70-nm-thick diamondlike films, followed by application of Al gate electrodes and ohmic contacts. The films are found to have bandgap 0.9-1.1 eV, resistivity 8.1 Mohm cm, breakdown field strength 1 MV/cm, and density 1.8 g/cu cm, to be thermally stable up to 400 C, and to undergo rapid decomposition above 450 C. The electrical properties of the MIS structures are significantly improved by sputter cleaning the substrates with a 1-keV 2-mA/sq cm Ar beam for 2 min at 300 microtorr prior to C-film deposition. The resulting structures have fixed insulator charge number densities 4 x 10 to the 12th/sq cm (InP), 7.5 x 10 to the 12th/sq cm (GaAs), and 9 x 10 to the 11th/sq cm (Si) and interface state densities (5, 200, and 0.5) x 10 to the 12th/ sq cm eV, respectively. It is suggested that the low optical bandgap and resistivity of the C films and the high insulator-charge and interface-state densities make them unstable as gate dielectrics for microelectronics.

Kapoor, V. J.↗

Conceptual study of hypersonic airbreathing missiles

The purpose of this paper is to report recent results of an in-house conceptual study to evaluate the performance potential and research needs of airbreathing hypersonic missiles. An alkylated-borane (noncryogenic) fueled, dual-mode, ramjet/scramjet propulsion system structured with a Rene 41 inlet and a carbon-carbon combustor was assumed along with a Lockalloy heat sink fuselage structure and beryllium wings and control surfaces. Performance for an air-launched baseline missile with a 961 pound staging weight containing a 100 pound payload indicated excellent long range cruise, moderate acceleration and high maneuverability potential. A sizing study indicates that Mach 6 cruise ranges of the order of 2500 nautical miles for payloads of 300 pounds can be achieved with moderate size missile carry weights (9000 lbs.). Aerodynamic heating analyses indicate that unprotected heat-sink structures with internal insulation are feasible for ranges of several hundred miles. For ranges of several thousands of miles a multiwall radiation shield (Inconel/titanium) was selected for protection of the internally insulated heat sink structure.

Hunt, J. L.↗