At least 55 records · Page 3

A novel method for effective sodium ion implantation into silicon

Although sodium ion implantation is useful to the surface modification of biomaterials and nano-electronic materials, it is a challenging to conduct effective sodium implantation by traditional implantation methods due to its high chemical reactivity. In this paper, we present a novel method by coupling a Na dispenser with plasma immersion ion implantation and radio frequency discharge. X-ray photoelectron spectroscopy (XPS) depth profiling reveals that sodium is effectively implanted into a silicon wafer using this apparatus. The Na 1s XPS spectra disclose Na{sub 2}O-SiO{sub 2} bonds and the implantation effects are confirmed by tapping mode atomic force microscopy. Our setup provides a feasible way to conduct sodium ion implantation effectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing electrical conductivity and electron field emission properties of ultrananocrystalline diamond films by copper ion implantation and annealing

Copper ion implantation and subsequent annealing at 600 °C achieved high electrical conductivity of 95.0 (Ωcm){sup −1} for ultrananocrystalline diamond (UNCD) films with carrier concentration of 2.8 × 10{sup 18} cm{sup −2} and mobility of 6.8 × 10{sup 2} cm{sup 2}/V s. Transmission electron microscopy examinations reveal that the implanted Cu ions first formed Cu nanoclusters in UNCD films, which induced the formation of nanographitic grain boundary phases during annealing process. From current imaging tunneling spectroscopy and local current-voltage curves of scanning tunneling spectroscopic measurements, it is observed that the electrons are dominantly emitted from the grain boundaries. Consequently, the nanographitic phases presence in the grain boundaries formed conduction channels for efficient electron transport, ensuing in excellent electron field emission (EFE) properties for copper ion implanted/annealed UNCD films with low turn-on field of 4.80 V/μm and high EFE current density of 3.60 mA/cm{sup 2} at an applied field of 8.0 V/μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Upgraded vacuum arc ion source for metal ion implantation

Vacuum arc ion sources have been made and used by a large number of research groups around the world over the past twenty years. The first generation of vacuum arc ion sources (dubbed ''Mevva,'' for metal vapor vacuum arc) was developed at Lawrence Berkeley National Laboratory in the 1980s. This paper considers the design, performance parameters, and some applications of a new modified version of this kind of source which we have called Mevva-V.Ru. The source produces broad beams of metal ions at an extraction voltage of up to 60 kV and a time-averaged ion beam current in the milliampere range. Here, we describe the Mevva-V.Ru vacuum arc ion source that we have developed at Tomsk and summarize its beam characteristics along with some of the applications to which we have put it. We also describe the source performance using compound cathodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion-implanted thermal barrier

Ion implantation can be used to define a thermal dissipation path that allows for better thermal isolation between devices in close proximity on a microelectronics chip, thus providing a means for higher device density combined with better performance.

42 ENGINEERING↗

Setting up of a low temperature in-situ ion implantation and channeling facility at Kalpakkam

A simple low temperature ion implantation and ion channeling facility has been set up. Low temperatures upto 70 K has been obtained on a goniometer sample holder by connecting to a continuous flow Helium cryostat with a copper braid. Charge integration is carried out with a transmission Faraday cup with 10 mm diameter aperture and four Faraday cups for performing ion implantation and an electron suppressed 1.5 mm aperture with a TEM grid of 60% beam transmission for ion beam analysis. Typical low temperature ion implantation and channeling experiments have been carried out. Stabilization at intermediate temperatures by controlling the heater at the sample holder and improvement of the achievable lowest temperature by having liquid nitrogen cooled heat shield are in progress.

43 PARTICLE ACCELERATORS↗

Mapping of fracture and ionic conductivity changes in ion implanted solid electrolytes: Insights from molecular dynamics

Ion implantation emerges as a promising technique to address the persistent challenge of lithium (Li) filament growth in solid-state electrolytes as it can induce compressive stresses inhibiting crack growth and deflect dendrites, de facto mitigating early electrolyte failure. In this study, we examine the potential paradox of ion implantation: while aiming to enhance electrolyte performance, the radiation damage associated with implantation might inadvertently compromise both the ionic conductivity and the intrinsic fracture toughness of the material, rendering the material unsuitable for battery applications. Specifically, we employed molecular dynamics simulations to examine the scope of the downsides of ion implantation, specifically: (i) reduced ionic conductivity (due to radiation-induced amorphization) and (ii) mechanical stability (due to radiation-induced embrittlement) in ion-implanted Li 7 La 3 Zr 2 O 12 (LLZO) solid-state electrolytes. We explore how radiation damage impacts LLZO’s crystalline structure, Li-ion diffusion, and fracture properties at various temperatures and radiation damage levels. The study aims to provide insights into the competing effects of ion implantation and suggest potential engineering strategies for developing more robust solid-state electrolytes with improved conductivity and dendrite resistance.

Conductivity↗

Radiation Modified Ion-Implanted Materials

The objective of this project, by BNL and PVI, is to develop radiation-modified materials like titanium, nickel, aluminum, steel, refractory metals and alloys by implanting them with ions. Ion implantation radically improves strength & friction resistance. The focus will be on components of products like jet engines & windmills. Example: implanting windmill parts subject to friction may greatly reduce operating costs. Currently, electric power from wind is a factor of 1.5 more costly than coal due to labor costs [frequent lubrication of parts involves stopping a windmill & opening its nacelle (enclosures)]. A 50% friction reduction through ion implantation of parts will reduce the need for lubricants and make wind-generated electricity cheaper than fossil fuel. Major PVI role is adapting laboratory experimental results into commercially viable industrial processes and marketing them.

36 MATERIALS SCIENCE↗

Characterization of carbon ion implantation induced graded microstructure and phase transformation in stainless steel

Austenitic stainless steel 316L is ion implanted by carbon with implantation fluences of 1.2 × 10{sup 17} ions-cm{sup −} {sup 2}, 2.4 × 10{sup 17} ions-cm{sup −} {sup 2}, and 4.8 × 10{sup 17} ions-cm{sup −} {sup 2}. The ion implantation induced graded microstructure and phase transformation in stainless steel is investigated by X-ray diffraction, X-ray photoelectron spectroscopy and high resolution transmission electron microscopy. The corrosion resistance is evaluated by potentiodynamic test. It is found that the initial phase is austenite with a small amount of ferrite. After low fluence carbon ion implantation, an amorphous layer and ferrite phase enriched region underneath are formed. Nanophase particles precipitate from the amorphous layer due to energy minimization and irradiation at larger ion implantation fluence. The morphology of the precipitated nanophase particles changes from circular to dumbbell-like with increasing implantation fluence. The corrosion resistance of stainless steel is enhanced by the formation of amorphous layer and graphitic solid state carbon after carbon ion implantation. - Highlights: • Carbon implantation leads to phase transformation from austenite to ferrite. • The passive film on SS316L becomes thinner after carbon ion implantation. • An amorphous layer is formed by carbon ion implantation. • Nanophase precipitate from amorphous layer at higher ion implantation fluence. • Corrosion resistance of SS316L is improved by carbon implantation.

36 MATERIALS SCIENCE↗

Tribo-corrosion and Albumin Attachment of Nitrogen Ion-Implanted CoCrMo Alloy During Friction Onset

In this paper, CoCrMo alloy surface was implanted with 100 keV nitrogen ions to modify it. Bovine serum albumin (BSA) adsorption and the initial behavior of tribo-corrosion in the simulated system were studied. Nitrogen ion implantation can promote BSA dynamic adsorption due to the change of friction and wear mechanisms. From the tribo-corrosion test results, the open circuit potential (OCP) increased to about 0.6 V and the coefficient of friction (COF) decreased to about 0.2 for the nitrogen ion-implanted CoCrMo compared with the untreated sample before the modified layer failure. The point when the open circuit potential and the coefficient of friction changed during long wear time (1, 2 and 4 h) is considered the sign of the worn through modified layer. Then, the OCP of the implanted sample rose by 0.3 V compared with the untreated sample, and the COF remained at around 0.3, which is lower compared with the COF of untreated sample after the modified layer has been worn through. Thus, nitrogen ion implantation not only improved wear and corrosion resistance of the CoCrMo alloy, but also promoted BSA adsorption on the CoCrMo alloy surface, which effectively reduced the wear volume and metal ions release.

36 MATERIALS SCIENCE↗

Ion-implanted Al0.6Ga0.4N deep-ultraviolet avalanche photodiodes

A deep-ultraviolet Al0.6Ga0.4N p–i–n avalanche photodiode (APD) structure was grown on a (0001) AlN bulk substrate by metalorganic chemical vapor deposition. The wafer was fabricated into 20 μm diameter mesa APD devices both with and without ion-implantation with nitrogen ions on the periphery of the p-type region of the diode mesa and tested. The dark current density vs bias, photoresponse, and the optical gain of the APDs with and without ion implantation were compared. The devices fabricated with ion implantation showed improved performance, exhibiting lower dark current densities of ∼1 × 10−9 A/cm2 and a higher optical gain of ∼5.2 × 105 at a current density limit of 0.3 A/cm2. The average temperature coefficients of the reverse-bias breakdown voltage were also compared. Although the data showed negative coefficients for APDs fabricated both with and without ion implantation, the ion-implanted APDs showed an improvement relative to the devices fabricated without ion-implantation.

Physics↗

Depth Profiling of N and C in Ion Implanted ZnO and Si Using Deuterium Induced Nuclear Reaction Analysis

Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x10{sup 14} ions cm{sup -2}. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm{sup -1} compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced {sup 12}C(d,p){sup 13}C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large cold shield (liquid nitrogen trap) in the ion implanter chamber greatly reduces the amount of carbon impurity on the surface of ion implanted silicon. Various implantations with N{sub 2}, O{sub 2}, NO, NO{sub 2} and Pb ions were performed with and without cooling of the liquid nitrogen trap. Simultaneous detection of ppm-level concentrations of {sup 12}C, {sup 16}O and {sup 14}N enables highly sensitive measurement of impurities that may be incorporated during the fabrication process, transport of the samples and/or storage of the samples in air.

36 MATERIALS SCIENCE↗

Hardening by ion implantation of VT1-0 alloy having different grain size

The paper presents a transmission electron microscopy (TEM) study of the structural and phase state of commercially pure titanium implanted by aluminum ions. TEM study has been carried out for two types of grains, namely coarse (0.4 µm) and small (0.5 µm). This paper presents details of the yield stress calculations and the analysis of strength components for the both grain types in two areas of the modified layer: at a distance of 0-150 nm (surface area I) and ∼300 nm (central area II) from the irradiated surface. It is shown that the ion implantation results in a considerable hardening of the entire thickness of the implanted layer in the both grain types. The grain size has, however, a different effect on the yield stress in areas I and II. Thus, near the ion-alloyed layer, the yield stress decreases with the increase of the grain size, whilst area II demonstrates its increase. Moreover, the contribution to the general hardening of the alloy made by certain hardening mechanisms differs from contributions made by each of these mechanisms in each certain case.

36 MATERIALS SCIENCE↗

Structural and Thermal Characterization of Ti+O Ion Implanted UltraHigh Molecular Weight Polyethylene (UHMWPE)

In this work, Metal-Gas Hybrid Ion Implantation technique was used as a tool for the surface modification of Ultra High Molecular Weight Polyethylene (UHMWPE). Samples were Ti+O ion implanted by using Metal-Vapour Vacuum Arc (MEVVA) ion implanter to a fluence of 5x10{sup 16} ion/cm{sup 2} for each species and extraction voltage of 30 kV. Untreated and surface treated samples were investigated by Rutherford Back Scattering (RBS) Spectrometry, Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) Spectroscopy, Thermo Gravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC). Results indicate that Ti+O ion implantation can be applied on UHMWPE surfaces successfully. ATR-FTIR spectra indicate that the C-H concentration on the surface decreased after Ti+O implantation. Thermal characterization with TGA and DSC shows that polymeric decomposition temperature is shifted after ion implantation.

36 MATERIALS SCIENCE↗

Theoretical investigation of sheath expansion and implant fluence uniformity in enhanced glow discharge plasma immersion ion implantation

In enhanced glow discharge plasma immersion ion implantation that involves a small-pointed anode and large area tabular cathode, the high negative substrate bias acts as the plasma producer and supplies the implantation voltage. An electric field is created to focus the electrons and the electron-focusing field in turn enhances the glow discharge process. The sheath physics is theoretically investigated using numerical simulation based on the multiple-grid particle-in-cell code. Electron focusing is corroborated and the plasma sheath has enough expansion when t=40 {mu}s so that a uniform distribution of the incident ion fluence is attained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristic properties of Raman scattering and photoluminescence on ZnO crystals doped through phosphorous-ion implantation

P-doped ZnO was fabricated by means of the ion-implantation method. At the Raman measurement, the blue shift of the E{sub 2}{sup high} mode and A{sub 1}(LO) phonon of the inactive mode were observed after the P-ion implantation. It suggested to be caused by the compressive stress. Thus, Hall effect measurement indicates that the acceptor levels exists in P-doped ZnO while still maintaining n-type ZnO. From the X-ray photoelectron spectroscopy, the chemical bond formation of the P2p{sub 3/2} spectrum consisted of 2(P{sub 2}O{sub 5}) molecules. Therefore, the implanted P ions were substituted to the Zn site in ZnO. From the photoluminescence (PL) spectra, P-related PL peaks were observed in the energy ranges of 3.1 and 3.5 eV, and its origin was analyzed at P{sub Zn}-2V{sub Zn} complexes, acting as a shallow acceptor. With increasing temperatures, the neutral-acceptor bound-exciton emission, (A{sup 0}, X), shows a tendency to quench the intensity and extend the emission linewidth. From the relations of the intensity and the linewidth as a function of temperature, the broadening of linewidth was believed to the result that the vibration mode of E{sub 2}{sup high} participates in the broadening process of (A{sup 0}, X) and the change of luminescent intensity was attributed to the partial dissociation of (A{sup 0}, X). Consequently, these facts indicate that the acceptor levels existed in P-doped ZnO layer by the ion implantation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion implantation for manufacturing bent and periodically bent crystals

Ion implantation is proposed to produce self-standing bent monocrystals. A Si sample 0.2 mm thick was bent to a radius of curvature of 10.5 m. The sample curvature was characterized by interferometric measurements; the crystalline quality of the bulk was tested by X-ray diffraction in transmission geometry through synchrotron light at ESRF (Grenoble, France). Dislocations induced by ion implantation affect only a very superficial layer of the sample, namely, the damaged region is confined in a layer 1 μm thick. Finally, an elective application of a deformed crystal through ion implantation is here proposed, i.e., the realization of a crystalline undulator to produce X-ray beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoscale patterns produced by self-sputtering of solid surfaces: The effect of ion implantation

A theory of the effect that ion implantation has on the patterns produced by ion bombardment of solid surfaces is introduced. For simplicity, the case of self-sputtering of an elemental material is studied. We find that implantation of self-ions has a destabilizing effect along the projected beam direction for angles of incidence θ that exceed a critical value. In the transverse direction, ion implantation has a stabilizing influence for all θ.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗