Qualification of Commercially Available Silicon Carbide for Passive Thermometry in Reactor Experiments – FY23 Status Report

Silicon carbide (SiC) is often used as a passive temperature indicator for uninstrumented in-core nuclear experiments. For the past several decades, Oak Ridge National Laboratory has relied primarily on SiC thermometry manufactured by Dow Chemical Company, formerly Rohm and Haas because of the material’s high density and reduced grain boundary elements. Although Dow SiC has performed well in this application, this material is no longer commercially available, and a new supplier is needed for future experiments. To determine a suitable replacement, a study was initiated on five types of SiC from four commercial vendors. Several critical properties, including density, electrical resistivity, chemical purity, grain structure, crystal structure, and strength were measured in samples from each material. Additionally, thermometry specimens were manufactured for irradiation in the High Flux Isotope Reactor at nominal temperatures of 300°C, 600°C, and 900°C, which will be measured using continuous dilatometry at a later date. This report provides an update of commercially available SiC material characterization and the irradiation capsule design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless Instrumented RB Experiment Preliminary Design and Analysis

The ability to deploy new nuclear fuels for current or future reactor concepts requires carefully designed experiments to generate data to support fuel qualification. Ideally these experiments would include state of-the-art sensing to maximize the amount of in situ data that can be collected during operation. Furthermore, advanced reactor systems can take advantage of integrated in-core sensing technologies to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator’s understanding of limiting peaking factors. Before any novel sensing technologies can be readily adopted for nuclear applications, they must first demonstrate acceptable performance in test reactors. This report summarizes the preliminary design and analysis of the most highly instrumented irradiation experiment ever performed in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The Wireless Instrumented RB Experiment 2021 (WIRE-21) will test a wide range of sensors including wireless sensors being developed by Westinghouse Electric Company (WEC) that could provide in situ measurements of peak fuel temperatures and fuel rod pressurization due to fission gas release. The ability to wirelessly transmit a signal through the fuel rod’s cladding is critical to improving fuel monitoring capabilities without requiring signal penetrations through the cladding pressure boundary, which would significantly impact fuel fabrication, handling, and operation. Other sensors that will be tested in WIRE-21 include an array of thermocouples, self-powered neutron detectors (SPNDs), and spatially distributed fiber-optic temperature sensors. More generally, WIRE-21 will establish a flexible irradiation vehicle design to allow accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. This report summarizes the mechanical design for WIRE-21, the experimental test matrix, initial neutronic and thermal design analyses, and the active monitoring and control system enhancements necessary to support testing of advanced sensor technologies. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) relevant to light water reactors (LWRs), but the flexible design of the experiment vehicle allows much higher operating temperatures (>1,100°C). Neutronic calculations determine the neutron flux conditions as well as the nuclear heating within the experiments. These results are used as inputs to detailed thermal finite element calculations, which are required to evaluate the complex, three-dimensional heat transfer that occurs within WEC’s wireless sensor enclosures. Initial results show that the temperatures of the sensors’ enclosures and the metal bellows can be operated near the temperature range of LWR coolants and cladding while simultaneously increasing the temperature of a surrogate fuel material to values in the range of 800–1200°C to simulate centerline fuel temperatures during LWR operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment on Transport of Radioactive Species from Nuclear Facilities - 17079

It is generally recognized that radioactive nuclides are most hazardous fission products that could be released in the event of reactor accidents. The reactor coolant system of a pressurized water reactor (PWR) nuclear plant exhibits radioactivity from various sources. These radiation sources consist of the fission products from fuel element and activated products from corrosion products. The complex infrastructure of the processes does not allow detailed measurement of activity until after the reactor is shutdown. All of the components that require dismantling will be radioactive which was caused by neutron activation during operation, contamination by corrosion products, contamination by damaged by fuel rods and leaks by equipment. Due mainly to the various operation modes and their aging, there are the increasing needs to carry out repair works that are not sufficiently provided for by the original design. Many difficulties are involved in these tasks, namely, high radiation doses, cramped areas, hard to reach components, coupled with stringent quality conditions. The need to simulate the behavior of corrosion products in a nuclear power plant environment has attracted many researchers' attention. It has performed the in-depth reviews of the various theories and physics associated with the corrosion products transportation, the laboratory loop testing, and the field measurements in operating plants. Before we start the decommissioning of nuclear power plants, workers, the public and the environment shall be properly protected from radiation hazards. For this purpose, a safety assessment should be carried out relating to the potential hazards that may occur during the decommissioning. The radiological hazards involved in the decommissioning activities also should be identified, and be taken into account in the safety assessment. The radiation conditions of the primary circuit are determined by the activity of corrosion and fission products that have accumulated on the internal surfaces of the components. Therefore the estimation of contamination on the components is very important and, may be the first step in the reactor operation and decommissioning of components. The predominant radionuclide in the PWR primary coolant is Co-60, although Co-58 contributes significantly to radioactivity level at the early stage of a reactor operation. Since Co-60 is produced from the in-core Co-58, which is the source of cobalt in a reactor coolant system, many researchers have investigated its transmutation in the core, its transport around the system, and its subsequent deposition on surfaces. The major parameter influencing the behavior of radioactivity, such as Co-60 in the coolant, is the corrosion product oxides. The objective of this work is to analyze the corrosion product activity transported in the primary circuit by using a multi-region model. This model, which is incorporated with the mass and activity transport between the dissolved corrosion products in the coolant and the surface, describes the specific activity of corrosion products in coolant and on the surfaces according to the operation modes as well as decommissioning stage. In order to evaluate the analysis of the corrosion products in an integral type reactor, a multi-region mass balance model is applied. The specific activities of the various species on the surface of core and steam generator throughout the effective full power hours, 15,000 hours, are simulated for the various modes of operations. As a result, the specific activities of corrosion products from the surface of primary circuit were shown as very low compared to those of other commercial nuclear power plants. In this simulated reactor, a significant reduction of specific activities from the activated corrosion products is obtained due to the introduction of titanium alloy to the steam generator tube and the avoidance of boric acid induced corrosion. From this result we conclude that we are able to predict the level of radioactive nuclides generated by corrosion products in a primary circuit according to the various modes of operations by using multi-region model. In this point of view it is concluded that this multi-region model can be used as an engineering tool for analysis of the corrosion products within the primary coolant for the nuclear power plants. It is also considered that it is possible to extend to a calculation tool for estimating the radiological hazards involved in the decommissioning activities in terms of safety assessment. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of temperature effects on self-powered neutron detectors in a gamma field

Self-powered neutron detectors (SPND) are small, robust, in-core radiation sensors that have the potential to operate in high temperature environments (above 600°C). However, previous experiments indicated temperature related effects in the form of displacement currents. Given the recent irradiation at The Ohio State University Research Reactor using a delayed-response rhodium-based SPND alongside a prompt-response tantalum-based SPND, it was concluded that only low-energy electrons from gamma interactions were the cause of these temperature effects. A series of heated gamma irradiations with temperatures up to 750°C of SPNDs were performed at the Advanced Test Reactor Gamma Facility in order to better characterize these displacement currents. The results from the experiments demonstrated a strong relation between the displacement currents that occurred during temperature ramps to thermoluminescence (TL) glow peaks—the SPND with Al2O3 insulation has one glow peak within 750°C and the SPND with MgO has three. A demonstration was performed to calculate the trap energy levels of the displacement currents through TL glow peak analysis. Unfortunately, the methods employed provided inconsistent results, requiring an updated model based on ongoing irradiation instead of post-irradiation measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Assessment of Sensor Technologies for Advanced Reactors

This paper provides an assessment of sensor technologies and a determination of measurement needs for advanced reactors (AdvRx). It is a summary of a study performed to provide the technical basis for identifying and prioritizing research targets within the instrumentation and control (I&C) Technology Area under the Department of Energy’s (DOE’s) Advanced Reactor Technology (ART) program. The study covered two broad reactor technology categories: High Temperature Reactors and Fast Reactors. The scope of “High temperature reactors” included Gen IV reactors whose coolant exit temperatures exceed ≈650 °C and are moderated (as opposed to fast reactors). To bound the scope for fast reactors, this report reviewed relevant operating experience from US-operated Sodium Fast Reactor (SFR) and relevant test experience from the Fast Flux Test Facility (FFTF). For high temperature reactors the study showed that in many cases instrumentation have performed reasonably well in research and demonstration reactors. However, even in cases where the technology is “mature” (such as thermocouples), HTGRs can benefit from improved technologies. Current HTGR instrumentation is generally based on decades-old technology and adapting newer technologies could provide significant advantages. For sodium fast reactors, the study found that several key research needs arise around (1) radiation-tolerant sensor design for in-vessel or in-core applications, where possible non-invasive sensing approaches for key parameters that minimize the need to deploy sensors in-vessel, (2) approaches to exfiltrating data from in-vessel sensors while minimizing penetrations, (3) calibration of sensors in-situ, and (4) optimizing sensor placements to maximize the information content while minimizing the number of sensors needed.

Korsah, Kofi↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Instrumentation for the In-Core Real-Time Mechanical Testing of Structural Materials (INCREASE) Project

Idaho National Laboratory (INL), in collaboration with the Electric Power Research Institute (EPRI), the Nuclear Regulatory Commission (NRC), the French Atomic and Alternative Energies Commission (CEA), the Joint Research Center (JRC), the Nuclear Research and Consultancy Group (NRG), and the Research Center Rez (CVR), started a Joint Experimental Program (JEEP) project that operates within the Nuclear Energy Agency’s Framework for Irradiation Experiments (FIDES II) program in order to develop capabilities for the in-core real-time mechanical testing of structural materials. This effort will focus on designing a shared capsule capable of housing a variety of in-core mechanical testing instrumentation allowing enhanced experiments for the material science community. The outcome of the project would be high-priority, stress relaxation data for stainless-steel-based materials provided by EPRI and CEA. Stress relaxation is a major phenomenon that contributes to material degradation in nuclear reactor components. Currently, nuclear material stress relaxation is assessed both before and after irradiation, using complex and costly post-irradiation examination (PIE) activities. In-situ data would support the development of precision modeling and simulation of this degradation phenomena and would provide validation and benchmarking for existing models using the PIE data. As part of the U.S. Department of Energy Advanced Sensor and Instrumentation (ASI) program, INL has fabricated and tested out-of-core mechanical test instrumentation. This instrumentation was designed for easy adaptation to the irradiation capsule proposed under this JEEP, and can be deployed to measure real-time stress relaxation under pressurized-water reactor (PWR) conditions. This initial effort will partially serve to replace the testing capabilities lost because of shutting down the Halden Boiling Water Reactor (HBWR). The project would provide these capabilities to the international community via a shared capsule design that is easily adaptable to additional material test reactors. The design features will incorporate expansion to PWR and non-light-water reactor (LWR) environments that will be developed in future work. The capsule and instrumentation will be demonstrated in the Massachusetts Institute of Technology Reactor (MITR) for phase I and the Petten High Flux Reactor (HFR) for phase II irradiations to deliver real-time stress relaxation data on high priority stainless steel structural materials.

36 MATERIALS SCIENCE↗

A potential emerging issue concerning repair welding of out-of-core PWR components involving tritium exposure and 3 He retention

This paper identifies a potential but previously unrecognized risk of helium-induced embrittlement and cracking during repair welding of out-of-core pressurized water reactor (PWR) components exposed to tritium-contaminated coolant. While previous weldability concerns centered on 4 He accumulation in neutron-irradiated alloys located within the in-core or near-core regions, new measurements show that 3 He generated by tritium decay can accumulate in out-of-core components. Because hydrogen isotopes readily diffuse to grain boundaries and become trapped there, significant 3 He generation at grain boundaries may lead to cracking during weld repairs. Initial data from far-below-core PWR flux thimble tubes confirm the presence of 3 He levels above known cracking thresholds for repair welds. In conclusion, these findings indicate that out-of-core regions should be considered when defining safe weld repair windows in reactors operating for 60–100 years.

Extended PWR lifetimes↗

A Data-driven approach to Core Power distribution reconstruction in a Nuclear Reactor

This report presents the initial development of a data-driven approach for reconstructing the core power distribution in a nuclear reactor (power shape synthesis) using ex-core sensors. Traditional techniques rely on deploying a large number of detectors throughout the reactor core. However, this approach is not feasible for innovative reactor concepts like Advanced Reactors and Microreactors. First, the tight lattice pitch, designed to maximize power density, limits the space available for sensors. Secondly, the harsh operating conditions are not compatible with commercially available detectors. The method proposed in this work integrates high-fidelity modeling with data-driven techniques to accurately reconstruct power distribution across various reactor types, thereby reducing the reliance on in-core sensors. Purdue University Reactor One (PUR-1) was selected as the test case. The CAD model representing the latest configuration of the PUR-1 core was imported into the OpenMC simulation framework, and the model was built. Additionally, the previously developed MCNP6 model was updated. The two models were assessed against the data collected during an experimental campaign conducted in July 2024. Thirty gold foils were placed in three Irradiation Assemblies in PUR-1 core. Using the measured activity of the irradiated foils, the neutron flux at different core locations was estimated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AN ADVANCED ULTRASONIC WAVEGUIDE CONCEPT FOR SPATIALLY DISTRIBUTED MONITORING OF IN-CORE TEMPERATURES

Critical process temperatures in a reactor core are conventionally measured using either resistance temperature detectors or thermocouples, both of which exhibit performance degradation at the temperature ranges of advanced reactors. Ultrasonic thermometry (UT) has long been offered as an alternative, potentially robust measurement option. With emerging interest in advanced reactors and a trend toward extracting more information from the core and the connected heat transport systems, UT is again considered a potential measurement method. Conventionally, acoustic waveguides employ simple notches at a measurement point to reflect incident waves. However, this approach results in rapid attenuation of acoustic energy as the wave crosses notches, as some fraction of its energy is reflected while the rest is transmitted. This research addresses this fundamental issue. This paper reports on the development of an ultrasonic waveguide concept that exploits the constructive interference of wave dynamics. The waveguide uses acoustic filters at the measurement zones that exhibit very high transmittance or reflectance as a function of interrogation frequency. Preliminary results will be discussed.

Cetiner, Nesrin↗

Resonance Self-shielding Impact on Neutron Spectrum Determination for Missouri S and T Reactor

Neutron Activation Analysis is a useful technique for characterizing the neutron flux at nuclear facilities. It involves irradiating samples to produce unstable isotopes, which enables qualitative and quantitative analyses of unknown samples. In the process, samples are bombarded with neutrons; new elements then become radioactive isotopes due to absorption of neutrons. These emit different amounts of gamma energy during the decay process, and gamma rays are counted using HPGe. Each reaction product has a known half-life and cross-section, and by measuring the amount of gamma radiation energy emitted from a radioactive isotope, it is possible to identify the isotope and activity. However, the neutron spectrum is not precise or representative of the actual neutron environment because of the self-shielding effect. This occurs with large samples that have large cross-sections or thicknesses in the resonance range of the neutron flux spectrum. Several methods have been used to mitigate this problem, such as thinning or diluting alloys samples, calculating the self-shielding factor for each material, and generating a corrected library for the unfolding procedure code. The Missouri University of Science and Technology Reactor (MSTR) is a pool-type research reactor that operates up to 200 kW. It uses light-water for both moderation and natural convective heat removal. The reactor core consists of 15 fuel elements positioned in a 9 x 6 aluminum grid plate, with four elements used for reactor power control. The fuel element is 19.75% low enriched uranium in 18 curved fuel plates. The reactor has seen various configurations starting with configuration designation 101W and subsequent reconfiguration increases the numeric designation by 1. The current configuration, 120W, was implemented in 2010. The new configuration provides more in-core locations for activation experiments and uses more fuel elements than previous ones. One of the irradiation locations in the MSTR core is the source holder. It is desired to improve the documentation of neutronic characteristics of the MSTR which are cardinal to experiments supported by the facility. One of these characteristics is the neutron spectrum at various locations in the reactor. Successful efforts yielded the neutron spectrum at a known location through the unfolding of the activity of irradiated foils. The purpose of this current study is to investigate the impact of resonance self-shielding of some of the activated foils on the determined spectrum.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Analysis of Damage to MPFDs Caused by Reactor Pulses

The need for next-generation, accident-tolerant fuels has generated significant interest in the restart of domestic fuels testing at the Transient Reactor Test (TREAT) facility. The TREAT reactor is designed to produce large, transient fluxes that replicate the effects of a wide variety of accident conditions on an irradiated fuel sample. Peak powers generated during short pulses approach 20 GW with a neutron flux of approximately 10{sup 17} n cm{sup -2} s{sup -1}. As part of the restart effort, new vehicle designs are being explored for sample irradiation, including the Static Environment Rodlet Transient Test Apparatus (SERTTA) and variants. As part of the SERTTA designs, micro-pocket fission detectors (MPFDs) are being explored for localized flux measurements before, during, and after transient operations. These detectors are also being considered as part of future, core-wide instrumentation for the TREAT reactor. However, the high fluxes associated with the pulses in the TREAT core present certain thermodynamic concerns given their intensity and the amount of energy they will release within the MPFDs within such a short amount of time. Assuming each fission that occurs in a MPFD results in a fission fragment depositing 85 MeV of energy in the substrate on average and each MPFD has 0.5 μg of natural uranium deposited on it, a 100 ms long pulse in the TREAT reactor at 1017 n cm{sup -2} s{sup -1} flux will produce approximately 4.6 x 10{sup 6} fissions in an MPFD. This pulse deposits 6.3 x 10{sup -5} J in the substrate over a 100 ms duration. That amount of energy is sufficient to melt roughly 33% of the Pt under the UO{sub 2} deposition or a circular spot with a diameter of approximately 860 μm. Of course, the above estimate makes a number of simplifying assumptions and ignores heat transfer, but does serve to illustrate the point that this rapid heating effect could be detrimental to the integrity and life of these in-core MPFDs. To study how these layers are affected by large transient neutron fluxes, five samples were prepared, pre-analyzed, and then subjected to a pulse in the central thimble of the Kansas State University TRIGA Mark II reactor to a peak power of 1.58 GW. After being allowed to decay to safer radiation levels, the sample substrates and coatings were inspected using scanning electron microscopy (SEM) to identify any changes to their surface morphology. Indeed, certain changes were found and are discussed in greater detail in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MITR RELAP5 Model Validations at Steady States and Transients

The Massachusetts Institute of Technology Reactor (MITR-II) is a 6 MW university research reactor designed primarily for experiments using neuron beams and in-core irradiation facilities, and education. The objective of this study is to validate the MITR RELAP5 model, which includes the reactor core, primary coolant loop, secondary coolant loop and heat exchanger models. Two sets of operational data were collected for validation. Steady-state data for 1 MW, 3 MW, 5.5 MW was obtained in the first test. The continuous startup transient data and the cooling tower outlet coolant temperature reduction obtained during the second test. The five steady-state conditions and two transient conditions were calculated by the RELAP5. The reactor power and cooling tower outlet temperature were used as boundary conditions while the reactor core inlet temperature and outlet temperature were calculated. A comparison was made between the modeling results and the temperature measurements. The results show that the MITR RELAP5 modeling results are in good agreement with measurement data for both steady-state and transient conditions.