Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Window convolution of the galaxy clustering bispectrum

In galaxy survey analysis, the observed clustering statistics do not directly match theoretical predictions but rather have been processed by a window function that arises from the survey geometry including the sky footprint, redshift-dependent background number density and systematic weights. While window convolution of the power spectrum is well studied, for the bispectrum with a larger number of degrees of freedom, it poses a significant numerical and computational challenge. In this work, we consider the effect of the survey window in the tripolar spherical harmonic decomposition of the bispectrum and lay down a formal procedure for their convolution via a series expansion of configuration-space three-point correlation functions, which was first proposed by Sugiyama et al. (2019). We then provide a linear algebra formulation of the full window convolution, where an unwindowed bispectrum model vector can be directly premultiplied by a window matrix specific to each survey geometry. To validate the pipeline, we focus on the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 (DR1) luminous red galaxy (LRG) sample in the South Galactic Cap (SGC) in the redshift bin 0.4 ≤ z ≤ 0.6. We first perform convergence checks on the measurement of the window function from discrete random catalogues, and then investigate the convergence of the window convolution series expansion truncated at a finite of number of terms as well as the performance of the window matrix. This work highlights the differences in window convolution between the power spectrum and bispectrum, and provides a streamlined pipeline for the latter for current surveys such as DESI and the Euclid mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Cold Trap Replacement Project Report

This report documents the replacement of the Mechanisms Engineering Test Loop (METL) cold trap. The work involved preparation of the facility to replace the cold trap, removal of the existing welded cold trap from the sodium purification circuit, installation of a new replacement cold trap, completion of associated welds and examinations, restoration of instrumentation and heaters, and controlled return of the cold trap circuit to service. The replacement represented a significant maintenance evolution because the cold trap is an integral welded component of the sodium system. As a result, the work required coordinated control of sodium chemistry, deliberate formation of freeze plugs, inert gas management, precision cutting and welding, and a staged reheating and refill sequence. The activity was executed using procedural controls intended to protect personnel, preserve system cleanliness, and maintain the integrity of the sodium boundary throughout the work. This report provides a narrative summary of the milestone, including the purpose of the work, the pre-job system condition, the major field activities performed, observations made during execution, and the resulting post-work condition of the METL cold trap circuit.

42 ENGINEERING↗

ATLAS-MAP: An Automated Test Station for Gated Electronic Transport Measurements

The diversification of electronic materials in devices provides a strong incentive for methods to rapidly correlate device performance with fabrication decisions. In this work, we present a low-cost automated test station for gated electronic transport measurements of field-effect transistors. Utilizing open-source PyMeasure libraries for transparent instrument control, the “ATLAS-MAP” system serves as a customizable interface between sourcemeters and samples under test and is programmed to conduct transfer curve and van der Pauw methods with static and sweeping gate voltages. Zinc oxide transistors of variable thickness (5, 10, and 20 nm) and channel size (50 μm to 3 mm, of equal length and width) were fabricated to validate the design. Standardization of testing procedures and raw data formatting enabled automated data analysis. A detailed list of parts and code files for the system are provided.

36 MATERIALS SCIENCE↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of Scale Bar for AGHCF Metallography Data

The DOE Nuclear Energy Advanced Reactor Technologies (ART) Fast Reactor Program (FRP) has supported the development of several databases containing information on the safety performance of fast reactors, components, and fuels. This growing collection of legacy experimental data, operating data, and analysis is available online to registered users. Metallography data represents one of the most critical types of post-irradiation examination (PIE) data being collected, organized, and archived in several ART Fast Reactor Databases (https://frdb.ne.anl.gov), including the Metallic Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT (the Transient Reactor Test Facility) Experimental Relational Database (TREXR). These databases contain three principal sets of metallography data. The first set comprises metallography data from Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) irradiated fuel pins examined in the Hot Fuel Examination Facility (HFEF). The second set consists of metallography data from EBR-II irradiated fuel pins examined in the Alpha-Gamma Hot Cell Facility (AGHCF). The third set includes metallography data from transient-tested fuel pins (including both out-of-pile furnace tests and TREAT tests) examined in AGHCF. Since both the second and third sets were generated in AGHCF, they are governed by identical specifications. The metallography data in the databases consist of digital images scanned from either positive or negative photographic films. To analyze the microstructure of a fuel pin, a series of preparatory steps are required, including sectioning, epoxy mounting, mechanical grinding and polishing, and etching. Following sample preparation, specimens are transferred for metallographic examination. The AGHCF and HFEF metallography data were generated using optical microscopes manufactured by Leitz and Bausch and Lomb (B&L). Images were recorded on Polaroid film at preset magnifications. Magnification verification for the Leitz and B&L metallographs was conducted every two months prior to 1989 and at least every six months from 1989 through the conclusion of the IFR program. Magnifications determined from imaging of microslide standards were compared to the instrument settings for magnifications ranging from 50× to 500×. If the magnifications determined from standards deviated from the instrument settings, adjustments were made to the bellows extension until agreement was achieved. The specifications for AGHCF and HFEF legacy metallography data have been established based on available hard-copy and digital records, most of which have been incorporated into the data repositories associated with FIPD, OPTD, and TREXR. Detailed specifications including hard-copy records, digitized records, cutting diagrams and sectioning schemes, high-magnification photographs, photomosaics (composites), information tags, scale bars, and magnification verification procedures can be found in a separate report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Boron isotopic analysis in bulk silicate materials using the Neoma MS/MS MC-ICP-MS

Boron (B) isotopes are a valuable tracer with applications ranging from geological, environmental, and nuclear studies because B isotopic fractionation is highly sensitive to chemical processes yielding distinct isotopic trends in natural and anthropogenic systems. Despite this wide applicability, there remain relatively few measurements on well-described reference materials and in some cases, poor agreement between various methods. We report a method for boron isotope ratio measurement in solution on the Neoma MS/MS MC-ICP-MS specifically targeting bulk silicates. We evaluate the performance of the method and instrument as it relates to the measurement of the absolute boron isotope ratio ( 10 B/ 11 B). The results indicate that the method produces data in agreement with literature values and that the sample–standard bracketing technique is appropriate for the Neoma MS/MS MC-ICP-MS which has been in use for decades on previous generation instruments. Careful tuning of the MS/MS lenses is required to obtain precision comparable to non MS/MS equipped MC-ICP-MS. With careful tuning, internal and external precisions of ∼0.3‰ were achieved. However, when the MS/MS is not properly tuned external precisions exceed 3‰. Nevertheless, our results for IAEA B-6, BCR-2, BHVO-2 and W-2a reference materials overlap the 1σ range of previously reported 10 B/ 11 B. Data are reported for total boron quantities down to a few tens of nanograms. Our procedure yielded blanks as low as 3 ng but up to 29 ng, making blank corrections important for small samples sizes in the few 10s of nanogram range. We report B isotope ratios for AGV-2G, SL-1G, GSC-2G, GSD-2G, GSE-2G, RLS-132, RLS-140, NKT-1G, and T1-G glass reference materials that have not been previously reported in the literature.

Scott, Sean R. [Pacific Northwest National Laborat↗

Constraining primordial non-Gaussianity with DESI 2024 LRG and QSO samples

We analyse the large-scale clustering of the Luminous Red Galaxy (LRG) and Quasar (QSO) sample from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). In particular, we constrain the primordial non-Gaussianity (PNG) parameter f NL loc via the large-scale scale-dependent bias in the power spectrum using 1,631,716 LRGs (0.6 < z < 1.1) and 1,189,129 QSOs (0.8 < z < 3.1). This new measurement takes advantage of the enormous statistical power at large scales of DESI DR1 data, surpassing the latest data release (DR16) of the extended Baryon Oscillation Spectroscopic Survey (eBOSS). For the first time in this kind of analysis, we use a blinding procedure to mitigate the risk of confirmation bias in our results. We improve the model of the radial integral constraint proposing an innovative technique allowing the correction through the window matrix convolution. We also carefully test the mitigation of the dependence of the target selection on the photometry qualities by incorporating an angular integral constraint contribution to the window function, and validate our methodology with the blinded data. Finally, combining the two samples, we measure f NL loc = -3.6 -9.1 +9.0 at 68% confidence, where we assume the universality relation for the LRG sample and a recent merger model for the QSO sample about the response of bias to primordial non-Gaussianity. Adopting the universality relation for the PNG bias in the QSO analysis leads to f NL loc = 3.5 -7.4 +10.7 at 68% confidence. Due to restricted selection in the LRG sample, the inclusion of the LRGs allows for 10% improvement. This measurement is the most precise determination of primordial non-Gaussianity using large-scale structure to date, surpassing the latest result from eBOSS by a factor of 2.3.

79 ASTRONOMY AND ASTROPHYSICS↗

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

Accelerated Lifetime Testing of Main Shaft Seals for Tidal Turbine Rotors

This document will briefly discuss the observations and results from an NREL conducted accelerated lifetime testing of the main shaft seal for the Verdant Power fifth generation Gen5 underwater Tidal Energy Converter (TEC) turbine, which successfully performed at the RITE project in 2020-2021. In order to evaluate a 5-year Service Interval ( SI) for this component, testing at NREL operated the main shaft seal nearly continuously for over 135 (text says 130 days on page 5 and 125 days on page 7 and 137 days on page 11) days at a rotational velocity of 160 rpm while the test stand recorded water pressure, barrier fluid pressure, temperature, and number of cycles., representing ~ 40% of the SI. An additional separate test was conducted to measure the aging behavior of the rubber drive rings. The water pressure reservoir was held constant as 29 psi. Barrier fluid pressure remained relatively constant throughout the duration of the test but was seen to sink to as low as 10.1 psi. No barrier fluid leakage was observed throughout the test. A sudden failure occurred within the seal after the power to test machine was interrupted for a scheduled building maintenance procedure. Upon restarting, the main shaft seal lost all ability to prevent water ingress. The exact cause is not known but is believed to be either a seal assembly issue or a change in the alignment of the seal components during or following the power outage. Following seal disassembly, significant wear was seen on one of the graphite sealing rings. Based on these results it is recommended that a follow-on TEAMER be conducted to rectify protocol and assembly issues to further evaluate SI of this component. The support and participation of Verdant Power Inc, Dovetail Solutions LLC and Garlock Manufacturing Inc were instrumental in understanding the results. NREL thanks them for their significant effort.

13 HYDRO ENERGY↗

Micromechanical response of SiC-OPyC layers in TRISO fuel particles

Tristructural isotropic (TRISO)–coated particle fuel is a proposed fuel for multiple advanced reactor concepts. The performance of the particle depends on whether the silicon carbide (SiC) layer remains intact to prevent the release of metallic and gaseous fission products. Mechanical fracture of the SiC layer is a potential failure mode under various fuel configurations and operating environments, including the potential transmission of matrix-originating cracks through TRISO particles. Furthermore, this study uses instrumented indentation techniques on cross-sectioned surrogate particles to examine the mechanical stability of the critical interface between SiC and the outer pyrolytic carbon (OPyC) layer. The observed behavior at the interface is rationalized by examining the radially dependent fracture behavior of the SiC layer and performing a numerical analysis to quantify the residual stresses that develop during the processing and cross-sectioning of the as-fabricated particle. Characterizing the SiC-OPyC interface of surrogate TRISO particles using nanoindentation provides unique insight into the interface's room-temperature residual stress and mechanical stability. The modeling efforts were used to investigate the experimental procedure further, and the results are presented herein to validate this fuel form's potential mechanical failure modes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CalTestBed - Delphire - Testing and Evaluation of Delphire Sentinel System (CRADA Final Report)

The Delphire Sentinel is a modular fire detection and communications system operating as a mobile field unit, with low voltage DC power supplied by onboard photovoltaics (PV) and batteries. The Sentinel addresses several aspects of fire detection, communications and data analysis. The Sentinel's mobility enables it to be rapidly deployed and operate independently of existing power and communications networks. The duration of independent operation depends critically on the energy consumption of the systems and performance of the onboard PV and battery. The purpose of this testing is to ascertain the power draw and energy consumption of the Delphire Sentinel prototype system under several operational states, including various data transfer packet sizes, transmission time and frequencies, and communication pathways (Wi-Fi, cellular, satellite) expected to be encountered in field deployments. It will also include procedures to test the ability of the Sentinel to operate for extended periods without loss of functionality. Based on results from energy and power measurements, and anticipated duty cycles in field deployments, we will model annual system autonomy (e.g. loss of load probability) for off-grid operation in representative locations.

47 OTHER INSTRUMENTATION↗

An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules

At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about -35°C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times — this study is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass Spectrometer Transient Analysis

This software implements a complete preprocessing pipeline for transient mass spectrometry (MS) data collected during TAP (Temporal Analysis of Products) experiments. It is designed to extract chemically meaningful fluxes from overlapping ion signals by applying a calibrated defragmentation matrix and solving the resulting linear system using non-negative least squares (NNLS) regression. The core script, preprocess_mass_spec.py, performs the following operations: Gain correction: Applies amplifier gain scalars derived from inert-packed calibration pulses to normalize signal intensities across AMUs and acquisition settings. Background subtraction: Removes experiment baselines using user-defined time windows, ensuring compatibility with slow-diffusing species and preventing negative values that would interfere with NNLS. Options to subtract before and after defragmentation. Defragmentation: Constructs a fragmentation matrix A from zeroth moments of calibration pulses (equal molar gas:inert mixtures) and solves Ax=b at each time point, where b is the raw MS signal and x is the estimated species flux. The matrix is normalized to inert signals and accounts for instrument-specific fragmentation behavior. Pulse-mode handling: Supports both averaged and individual pulse modes, enabling statistical treatment of fluxes and calculation of standard deviations. Integration and output: Computes zeroth moments (integrated fluxes) and exports time-resolved and integrated data in CSV format, suitable for downstream kinetic modeling. The software is validated using both virtual TAP simulations (VTAP) and experimental data from propane dehydrogenation (PDH) on CrOx/Al2O3 catalysts. It preserves temporal resolution by applying NNLS point-by-point across the pulse duration (typically 6,000+ time slices per pulse), leveraging the linear superposition principle to reconstruct full flux profiles. The defragmented outputs are compatible with kinetic extraction methods such as the G and Y procedures, which are used to derive rate–concentration relationships from TAP data. The details of these validations are discussed in detail in the supporting manuscript and supporting information. Example data and output files are also included. The methodology is robust to experimental noise and drift, with calibration protocols that account for pulse size effects, MS aging, and inert gas normalization. The software is modular, reproducible, and tailored for high-throughput TAP-MS workflows in catalysis research.

Kristy, Stephen [Idaho National Laboratory (INL), ↗

Assessment of Condition Monitoring Methods and Technologies for Inservice Inspection and Testing of Nuclear Power Plant Components

This report was prepared for the U.S. Nuclear Regulatory Commission (NRC) to explore the application of advanced technologies toward meeting the current and future regulatory requirements for maintenance and condition monitoring of structures, systems, and components. The advanced technologies considered in this work are advanced sensors and instrumentation, data analytics, machine learning and artificial intelligence (ML/AI), physics-based models, and digital twins (DT). The interest in the application of advanced technologies for condition monitoring in nuclear power plants continues to grow, and current and future licensees are expected to implement advanced technologies as part of their inservice inspection (ISI) and inservice testing (IST) programs. This report delineates the outcomes of an exploratory investigation into the implementation of advanced condition monitoring technologies to address ISI and IST requirements. A thorough review was conducted of the existing regulatory requirements for ISI and IST, along with an analysis of associated industry practices. Additionally, a state-of-the-art assessment was performed on advanced condition monitoring technologies frequently employed in non-nuclear sectors. This research incorporated two nuclear-specific case studies to illustrate the application of these technologies within the current nuclear fleet. The report provides an exhaustive discussion on the technical challenges, considerations, and opportunities associated with the deployment of advanced condition monitoring technologies. The following are key considerations in the application of advanced technologies for the ISI and IST of nuclear power plant components: • Developing adequate verification and validation procedures to confirm the functional and non-functional requirements, • Developing technical capabilities to conduct real-time asset condition monitoring, • Establishing guidance and protocol for modeling and simulation tools to continuously meet regulatory requirements, • Addressing trustworthiness, explainability, and interpretability of ML/AI methods, • Evaluating maintenance activities to maintain an adequate safety margin and avoid undesirable conditions, • Establishing cybersecure condition monitoring programs associated with a computer-based software system, and • Establishing standardized evaluation metrics for advanced condition monitoring programs. Interest in the use of advanced technologies for condition monitoring in ISI and IST programs continues to grow, and the technology is expected to experience rapid and wide industry adoption in the near future. Adoption of advanced technologies for condition monitoring could have novel and unique impacts on regulatory activities associated with ISI and IST programs. The NRC is continuing to explore the regulatory aspects of advanced technologies as part of ISI and IST programs by pursuing additional research in this technical area.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗