Bench cooling the Thematic Mapper

The present investigation is concerned with the bench cooling system which was developed in conjunction with the Thematic Mapper (TM), a second-generation earth resources sensor. A small, permanently evacuated dewar, which is carried into space with the instrument, is employed to provide thermal isolation for bench cooling IR detectors of many space-borne instruments. This approach has, however, a number of disadvantages. The system designed for cooling the TM makes, therefore, use of a new approach, involving a temporarily evacuated, take-apart dewar in combination with a temperature-controlled Joule-Thomson cryostat.

Kuyper, D. J.↗

Kinetics of a gas adsorption compressor

Chan (1981) has suggested that a process based on gas adsorption could be used as a means to drive a Joule-Thomson (J-T) device. The resulting system has several advantages. It is heat powered, it has no sealing, there are no mechanical moving parts, and no active control is required. In the present investigation, a two-phase model is used to analyze the transients of a gas adsorption compressor. The modeling of the adsorption process is based on a consideration of complete thermal and mechanical equilibrium between the gaseous phase and the adsorbed gas phase. The experimental arrangement for two sets of kinetic tests is discussed, and data regarding the experimental results are presented in graphs. For a theoretical study, a two-phase model was developed to predict the transient behavior of the compressor. A computer code was written to solve the governing equations with the aid of a standard forward marching predictor-corrector method.

Chan, C. K.↗

Design of Cryocoolers for Microwatt Superconducting Devices

The primary applications of the cryocoolers are for cooling various Josephson devices such as SQUID magnetometers and amplifiers, voltage standards, and microwave mixers and detectors. The common feature of these devices is their extremely low inherent bias power requirement, of the order of 10/1 W per junction. This provides the possibility of designing compact, low-power cryocoolers for these applications. Several concepts were explored and a number of laboratory model cryocoolers were built. These include low-power nonmagnetic regenerative machines of the Stirling or Gifford-McMahon type, three or four-stage Joule-Thomson machines, liquid-helium dewars with integral small cryocoolers to reduce the evaporation rate, and liquid-helium dewars with integral continuously or intermittently operated small helium liquefiers to permit operation of cryogenic devices for indefinite time periods.

Zimmerman, J. E.↗

Magnetic refrigeration for low-temperature applications

The application of refrigeration at low temperatures ranging from production of liquid helium for medical imaging systems to cooling of infrared sensors on surveillance satellites is discussed. Cooling below about 15 K with regenerative refrigerators is difficult because of the decreasing thermal mass of the regenerator compared to that of the working material. In order to overcome this difficulty with helium gas as the working material, a heat exchanger plus a Joule-Thomson or other exponder is used. Regenerative magnetic refrigerators with magnetic solids as the working material have the same regenerator problem as gas refrigerators. This problem provides motivation for the development of nonregenerative magnetic refrigerators that span approximately 1 K to approximately 0 K. Particular emphasis is placed on high reliability and high efficiency. Calculations indicate considerable promise in this area. The principles, the potential, the problems, and the progress towards development of successful 4 to 20 K magnetic refrigerators are discussed.

Barclay, J. A.↗

Reciprocating magnetic refrigerator

A 4 to 15 K magnetic refrigerator to test as an alternative to the Joule-Thomson circuit as the low temperature stage of a 4 to 300 K closed-cycle refrigerator was developed. The reciprocating magnetic refrigerator consists of two matrices of gadolinium gallium garnet spheres located in tandem on a single piston which alternately moves each matrix into a 7 telsa magnetic field. A separate helium gas circuit is used as the heat exchange mechanism for the low and the high temperature extremes of the magnetic refrigerator. Details of the design and results of the initial refrigerator component tests are presented.

Johnson, D. L.↗

Hydride absorption refrigerator system for ten Kelvin and below

A very long-life, lightweight and efficient hydride absorption refrigerator system was built to operate at ten Kelvin and below. The system consists of four basic stages of refrigeration. The first stage is accomplished by an active refrigeration system. The second stage is operated by a hydride absorption system, wherein a heated hydride powder drives off high pressure hydrogen through a Joule-Thomson/heat exchanger expansion loop such that the hydrogen is partially liquefied. In the third stage, the vapor pressure over the collected liquid hydrogen is lowered by absorbing the hydrogen vapor onto a different low pressure, worn hydride. With a 1.7 torr partial pressure of hydrogen gas in the hydride, liquid hydrogen is solidified and sublimes at 10 K. Long-life adiabatic demagnetization refrigerators, helium desorption, or helium diaphragm compressors are used to cool to 4 K or below. It is shown that the hydride concepts provide an extremely efficient means of refrigeration to 10 K, and that an entire sorption refrigeration process can be accomplished solely by using low grade heat energy at about 150 C.

Jones, J. A.↗

Cryogenic optical systems and instruments; Proceedings of the Meeting, San Diego, CA, August 23, 24, 1984

Systems considerations for the Shuttle Infrared Telescope Facility (SIRTF) are discussed, taking into account SIRTF telescope engineering and trade studies, implications of orbital inclination for SIRTF design and operations, the approaching of the natural background limit with the SIRTF, a long life feasibility study for SIRTF, and the impact of chopping on image quality in the SIRTF telescope. Cryogenic systems and coolers for space missions are considered, giving attention to the Infrared Astronomical Satellite (IRAS) hardware flight performance, the design of the superfluid helium dewar for the Cosmic Background Explorer (COBE), Infrared Telescope (IRT) system cryogenic performance, the solidification of a cryogen by pumping, the production of superfluid helium using a Joule-Thomson Expander, and open cycle He-3 cooling to 0.18 K for space operation. Other topics explored are related to cryogenic optical instruments, facilities, and components, and to supporting technology for cryogenic infrared telescopes in space.

Melugin, R. K.↗

A comparison of three types of pulse tube refrigerators - New methods for reaching 60 K

The three types of pulse tube refrigerator, namely the resonant, basic, and orifice designs, are compared with each other and with such common refrigerators as the Joule-Thomson and Stirling types, using an apparatus able to measure their intrinsic behavior from 30 to 300 K. Orifice pulse tubes are found capable of reaching 60 K temperature drops in a single stage. Additional advantages of the type are (1) a single, room-temperature moving part, (2) the use of moderate pressures and pressure ratios, (3) good intrinsic efficiency, and (4) the ability to operate several stages from the same pressure wave generator. The low refrigeration rate/unit mass flow means, however, that better regenerator units are required.

Radebaugh, Ray↗

Dynamic design of gas sorption J-T refrigerator

A long-life Joule-Thomson refrigerator which is heat powered, involves no sealing, and has few mechanical parts is desirable for long-term sensor cooling in space. In the gas-sorption J-T refrigerator, cooling is achieved by gas sorption (either adsorption or absorption) processes. Currently, a modular, single-stage refrigerator is being designed and built to be operated at 20 K. The design was analyzed using a dynamic model, which is described here. The model includes the kinetics of the compressors and the heat switches, the heat transfer of the pre-coolers and the heat exchangers, the on/off ratio of the check valves, and the impedance of the J-T valve. The cooling power, the cycle time, and the operating conditions were obtained in terms of the power input, the heat sink temperature, and the J-T impedance.

Chan, C. K.↗

Short-Cycle Adsorption Refrigerator

Modular adsorption/Joule-Thomson-effect refrigerator offers fast regeneration; adsorption/desorption cycle time expected to be 1 minute. Pressurized hydrogen generated by bank of compressor modules during heating phase passes through system of check valves and expands in Joule-Thomson junction as it enters refrigeration chamber. Hydrogen absorbs heat from load before it is sucked out by another bank of compressor modules in cooling phase.

Chan, C. K.↗

Oxygen chemisorption cryogenic refrigerator

The present invention relates to a chemisorption compressor cryogenic refrigerator which employs oxygen to provide cooling at 60 to 100 K. The invention includes dual vessels containing an oxygen absorbent material, alternately heated and cooled to provide a continuous flow of high pressure oxygen, multiple heat exchangers for precooling the oxygen, a Joule-Thomson expansion valve system for expanding the oxygen to partially liquefy it and a liquid oxygen pressure vessel. The primary novelty is that, while it was believed that once oxygen combined with an element or compound the reaction could not reverse to release gaseous oxygen, in this case oxygen will indeed react in a reversible fashion with certain materials and will do so at temperatures and pressures which make it practical for incorporation into a cryogenic refrigeration system.

Jones, Jack A.↗

Integrated Heat Switch/Oxide Sorption Compressor

Thermally-driven, nonmechanical compressor uses container filled with compressed praseodymium cerium oxide powder (PrCeOx) to provide high-pressure flow of oxygen gas for driving closed-cycle Joule-Thomson-expansion refrigeration unit. Integrated heat switch/oxide sorption compressor has no moving parts except check valves, which control flow of oxygen gas between compressor and closed-cycle Joule-Thomson refrigeration system. Oxygen expelled from sorbent at high pressure by evacuating heat-switch gap and turning on heater.

Bard, Steven↗

Expansion Valve With Temperature-Sensitive Flow Regulation

Joule-Thomson expansion valve designed so particles or condensed contaminants in vapor flowing through unlikely to clog orifice. In addition, new valve automatically adjusts flow of vapor. Allows high initial flow for rapid cooling, but gradually reduces flow as operating temperature reached. Flow adjusts manually when necessary. Developed for expansion of high-pressure vapors to condense them into low-pressure cryogenic liquids. Used to conserve helium coolant in superconducting system by condensing vapor boiling from liquid-helium bath.

Walker, Graham↗

Sorption cooler technology development at JPL

Simple heating and cooling of chemisorption and physisorption compressors provide high pressure gas, which, when expanded through a Joule-Thomson (J- T) valve, can provide cooling from 0.3 to 200 K depending on the sorbent/gas combination. System life tests are under way on Pr(1-n)Ce(n)O(x)/O2 (PCO/O2) chemisorption compressors for 65-80 K cooling and on carbon/krypton (C/Kr) physisorption compressors for 120-140 K cooling. Investigations have been initiated to examine reliability physics issues related to critical compressor components such as sorbents, container materials and electrical heaters.

Jones, J. A.↗

Development of a cryogenic mixed fluid J-T cooling computer code, 'JTMIX'

An initial study was performed for analyzing and predicting the temperatures and cooling capacities when mixtures of fluids are used in Joule-Thomson coolers and in heat pipes. A computer code, JTMIX, was developed for mixed gas J-T analysis for any fluid combination of neon, nitrogen, various hydrocarbons, argon, oxygen, carbon monoxide, carbon dioxide, and hydrogen sulfide. When used in conjunction with the NIST computer code, DDMIX, it has accurately predicted order-of-magnitude increases in J-T cooling capacities when various hydrocarbons are added to nitrogen, and it predicts nitrogen normal boiling point depressions to as low as 60 K when neon is added.

Jones, Jack A.↗

Low capacity Linde-Hampson nitrogen liquefier

A closed-cycle Linde-Hampson nitrogen liquefier was developed incorporating a new, non-clogging, demand flow Joule-Thomson nozzle. The flow area of the nozzle, a tapered annular orifice, is regulated by a very rugged load-sensitive differential thermal expansion scheme and by a manually adjustable micrometer mechanism. Labyrinth flow spoilers within the orifice provide turbulent voids which break up and clear contaminants from the flow. The system's four-stage compressor features sealed, oil-free compression spaces and a very compact nested piston configuration with a minimum of moving parts and drive complexity. The drive mechanism is a rolling Scotch yoke which minimizes piston side forces and seal wear for prolonged operating life. The closed-cycled system is controlled by an innovative load-responsive electronic feedback circuit which further reduces wear and input power.

Hedegard, K.↗

Space Cryogenics Workshop, 10th, Cleveland, OH, June 18-20, 1991, Proceedings

The present workshop on cryogenics discusses the anomalous on-orbit behavior of the Cosmic Background Explorer Dewar, the SHOOT orbital operations, cooling options for Astromag, and space IR telescope facility mission and cryogenic design. Attention is given to the design of a spaceworthy adiabatic demagnetization refrigerator, the evaluation of metal hydride compressors for applications in Joule-Thomson cryocoolers, diaphragm Stirling cryocooler developments, and a computer simulation model for Stirling refrigerators. Topics addressed include low-gravity thermal stratification of liquid helium on SHOOT, a screening program to select a resin for gravity probe-B composites, a simplified generic cryostat thermal model for predicting cryogen mass and lifetime, and the effect of gas mass flux on cryogenic liquid jet breakup. Also discussed are damping criteria for thermal acoustic oscillations in slush and liquid hydrogen systems, an STS-based cryogenic fluid management experiment, and the design and testing of a cryogenic mixer pump.

Source record↗

640 x 480 MWIR and LWIR camera system developments

The performance of a 640 x 480 PtSi, 3,5 microns (MWIR), Stirling cooled camera system with a minimum resolvable temperature of 0.03 is considered. A preliminary specification of a full-TV resolution PtSi radiometer was developed using the measured performance characteristics of the Stirling cooled camera. The radiometer is capable of imaging rapid thermal transients from 25 to 250 C with better than 1 percent temperature resolution. This performance is achieved using the electronic exposure control capability of the MOS focal plane array (FPA). A liquid nitrogen cooled camera with an eight-position filter wheel has been developed using the 640 x 480 PtSi FPA. Low thermal mass packaging for the FPA was developed for Joule-Thomson applications.

Tower, J. R.↗