Search NASA⌕ Search

SEARCH · Search NASA

Results for “LLRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of an FGPA-Based Cavity Simulator for Testing RF Controls

LLRF is used to precisely control the amplitude and phase of the RF field in cavities. Often times, access to test the control algorithms with RF equipment, especially in the presence of beam, is limited or beyond reach. In such cases, testing must be done through computer modeling or simulations. Computer modeling is often too slow and difficult to interface with the LLRF hardware. Analog or digital cavity simulators are preferred as they allow for interaction with the LLRF controls platform in real-time, and compared to their analog counterparts, FPGA-based digital cavity simulators allow for a more adjustable and sophisticated implementation. The newly developed FPGA-based cavity simulator includes the cavity electrical model, the cavity mechanical model including Lorentz Force Detuning and microphonics, an amplifier model which can simulate real amplifier nonlinearities, and a beam model. The simulator has been validated using measurements from BNL’s CeC 704 MHz 5-cell SRF cryomodule.

43 PARTICLE ACCELERATORS↗

Warm Front End Upgrade for the PIP-II Linac

The warm front end for the PIP-II Linac consists of an Ion-source, an RFQ, and four buncher cavities. The LLRF systems for these were the first ones developed more than a decade ago for use at the test stands. Some were VXI crate based, and others used early generation FPGA boards that are light in resources. These LLRF systems and the one for the first superconducting cryomodule, the HWR will be upgraded with the ARRIA 10 SOC-FPGA chassis with EPICS interfaces like the rest of the PIP-II Linac. The RFQ and the HWR have unique resonance control systems which are integrated into the LLRF controller hardware. The results of the initial testing with a cavity emulator will be presented.

Reyes, Lennon [Fermilab] (ORCID:0009000891155652)↗

Active Microphonics Compensation for LCLS-II

Testing of early LCLS-II cryomodules showed microphonics-induced detuning levels well above specification. As part of a risk-mitigation effort, a collaboration was formed between SLAC, LBNL, and Fermilab to develop and implement active microphonics compensation into the LCLS-II LLRF system. Compensation was first demonstrated using a Fermilab FPGA-based development system compensating on single cavities, then with the LCLS-II LLRF system on single and multiple cavities simultaneously. The primary technique used for this effort is a bank of narrowband filter set using the piezo-to-detuning transfer function. Compensation automation, optimization, and stability studies were done. Details of the techniques used, firmware/software implementation, and results of these studies will be presented.

43 PARTICLE ACCELERATORS↗

CEBAF Photo Gun RF System

During the CEBAF 12 GeV Upgrade at Jefferson Lab, a fourth experimental hall, ?D?, was added to the existing three halls. To produce four beams and deliver them to all halls concurrently requires new frequencies and a new timing pattern of the electron bunches. Since a photo-gun is used to produce electron bunches, the gun?s drive laser pulses need to be synchronized with the required bunch rate frequencies of 499 MHz or 249.5 MHz. To meet these new operational requirements, the new LLRF system has been proposed. Very specific requirements (dual frequency operation) on one side and the simple RF drive mode operation on the other imply the use of a commercial off-the-shelf digital platform rather than a system typical for RF cavity field control. We have chosen the Texas Instruments FPGA board along with a high-speed 8-Channel, 14-Bit board, and a 4-Channel, 16-Bit board. The DAC board includes the clock generator for clocking ADCs, DACs and the FPGA. The only custom design section of the system is the RF Front End board. The complete Gun Laser LLRF system has been designed, built, and recently commissioned in the CEBAF Injector. This paper will detail the design and report on commissioning activities.

Plawski, Tomasz↗

Time-domain simulation of the crab cavity/beam interaction

The Electron-Ion Collider (EIC) will employ crab cavities to maximize luminosity. A time-domain simulation is developed to study the interaction between the particle beam and the crab cavities in the EIC, including the Low-Level RF (LLRF) feedback loops. The simulation is validated through power and induced voltage estimates. We then use the simulation tool to study the beam loading effects on the crabbing voltage and thus on the beam transverse position and tilt. We also study the crabbing voltage regulation and transmitter power transients as a function of the LLRF design.

43 PARTICLE ACCELERATORS↗

Progress in developing a superconducting accelerator for efficient eBeam and X-ray production

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

43 PARTICLE ACCELERATORS↗

Proton Improvement Plan II (PIP-II) Clock and Timing

The PIP-II timing system is planned to be a two-part system consisting of a global timing system (referred to as ACLK) that provides high level, event-based timing for the whole Fermilab accelerator complex while the second part is a RF synchronized clock system unique to the PIP-II Linac itself (referred to as LCLK). The ACLK System will make use of an external 10 MHz GPS based signal source as a reference for its 650 MHz phase lock as it is the reference frequency for the TCLK output of the system (needed to support legacy hardware around complex). The LCLK System will use a PIP-II Linac RF reference (162.5 MHz) from the Linac LLRF system to allow beam synchronized event placement. Both the ACLK and LCLK systems will have a clock output with a data frame of 16 event bits + 32 data bits with frames broadcast at 650 MHz, phase locked to the 10MHz reference in the case of ACLK and the PIP-II LLRF sourced 162.5 MHz reference in the case of LCLK.

43 PARTICLE ACCELERATORS↗

Fermilab PIP-II Master Oscillator and Precision Reference Line Design and Construction

The phase averaging reference line system pro- vides the RF phase reference, LO and clock sig- nals to the LLRF and other accelerator sub- systems. The PIP-II linac has RF systems at three frequencies – 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase- noise oscillator is used as the master oscil- lator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each fre- quency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, Ahmed [Fermilab]↗

Low Level RF Control for the PIP-II Accelerator

The PIP-II accelerator is a proposed upgrade to the Fermilab accelerator complex that will replace the existing, 400 MeV room temperature LINAC with an 800 MeV superconducting LINAC. Part of this upgrade includes a new injection scheme into the booster that levies tight requirements on the LLRF control system for the cavities. In this paper we discuss the challenges of the PIP-II accelerator and the present status of the LLRF system for this project.

43 PARTICLE ACCELERATORS↗

Control Systems Design for STS Accelerator

The Second Target Station (STS) Project will expand the capabilities of the existing Spallation Neutron Source (SNS), with a suite of neutron instruments optimized for long wavelengths. A new accelerator transport line will be built to deliver one out of four SNS pulses to the new target station. The Integrated Control Systems (ICS) will provide remote control, monitoring, OPI, alarms, and archivers for the accelerator systems, such as magnets power supply, vacuum devices, and beam instrumentation. The ICS will upgrade the existing Linac LLRF controls to allow independent operation of the FTS and STS and support different power levels of the FTS and STS proton beam. The ICS accelerator controls are in the phase of preliminary design for the control systems of magnet power supply, vacuum, LLRF, Timing, Machine protection system (MPS), and computing and machine network. The accelerator control systems build upon the existing SNS Machine Control systems, use the SNS standard hardware and EPICS software, and take full advantage of the performance gains delivered by the PPU Project at SNS.

Yan, Jay↗

Master Oscillator and Phase Reference Line Design for the PIP-II Linac

The phase averaging reference line system provides the RF phase reference, LO and clock signals to the LLRF and other accelerator sub-systems. The PIP-II linac has RF systems at three frequencies - 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase-noise oscillator is used as the master oscillator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each frequency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, A. [Fermilab]↗

Transverse emittance growth due to rf noise in crab cavities: Theory, measurements, cure, and high luminosity LHC estimates

The High-Luminosity LHC (HL-LHC) upgrade with planned operation from 2029 onward has a goal of achieving a tenfold increase in the integrated number of recorded collisions thanks to a doubling of the intensity per bunch ( 2.2 × 10 11 protons) and a reduction of β * (the β value in the two high luminosity detectors, namely ATLAS and CMS) to 15 cm. Such an increase in recorded collisions would significantly expedite new discoveries and exploration. Crab cavities are an important component of the HL-LHC upgrade and will contribute strongly to achieving an increase in the number of recorded collisions. However, noise injected through the crab cavity radio frequency (rf) system could cause significant transverse emittance growth and limit luminosity lifetime. We presented a theoretical formalism relating transverse emittance growth to rf noise in an earlier work. In this follow-up paper, we summarize measurements in the super-proton synchrotron (SPS) at CERN that validate the theory, we present estimates of the emittance growth rates using state-of-the-art rf and low-level rf (LLRF) technologies, and we set the rf noise specifications to achieve acceptable performance. A novel dedicated feedback system acting through the crab cavities to mitigate emittance growth will be required. In this work, we develop a theoretical formalism to evaluate the performance of such a feedback system in any collider, identify limiting components, present simulation results to validate these studies, and derive key design parameters for an HL-LHC implementation of such a feedback system. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

RF transient analysis and stabilization of the phase and energy of the proposed PIP-II LINAC

Here, this paper describes a recent effort to develop and benchmark a simulation tool for the analysis of RF transients and their compensation in an H- linear accelerator. Existing tools in this area either focus on electron LINACs or lack fundamental details about the LLRF system that are necessary to provide realistic performance estimates. In our paper we begin with a discussion of our computational models followed by benchmarking with existing beam-dynamics codes and measured data. We then analyze the effect of RF transients and their compensation in the PIP-II LINAC, followed by an analysis of calibration errors and how a Newton’s Method based feedback scheme can be used to regulate the beam energy to within the specified limits.

43 PARTICLE ACCELERATORS↗

slaclab/llrf-hls

This is the repository for "llrf-hls" developed by SLAC National Accelerator Laboratory.

Vasquez, Jesus↗

The RF Protection Interlock System Prototype Verification

The Radio Frequency Protection Interlock system plays vital role in the LLRF related/dependent accelerator sections Protection. It’s main role is to collect information from number different sensors and indicators around nearest cavities and cryomodule and provide instant RF signal termination in case of safety thresholds violation. This submission describes newly designed RFPI system tailored to the Proton Improvement Plan II (PIP-II) requirements. The proof of concept prototype of this system has been build. The paper includes also the CMTF environment evaluation tests results and findings as an input to the next full-scope prototype design.

43 PARTICLE ACCELERATORS↗

Magnetron R&D toward the Amplitude Modulation Control for SRF Accelerator

The scheme of using a high efficiency magnetron to drive a superconducting radio frequency (SRF) accelerator cavity needs not only the injection phase locking but also the amplitude modulation to compensate the cavity's microphomics caused cavity voltage change and the beam loading variation. To be able to do a fast and efficient modulation, the magnetron's magnetic field has to be trimmed by an external coil to compensate the frequency pushing effect due to the anode current change [1]. A low eddy current magnetron body has been designed and built [2]. This paper will present the analytical prediction, simulation and experimental results on the 2.45 GHz magnetron test stand with the modulation frequency up to 1 kHz. In addition, the progresses on the injection lock to a copper cavity, new 1497 MHz magnetron prototype, 13 kW high power magnetron test stand development and newly built low level RF (LLRF) controller for the amplitude modulation will be reported.

Rimmer, Robert A.↗