Search NASA⌕ Search

SEARCH · Search NASA

Results for “MOLECULAR PUMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Red Fluorescent Line Emission from Hydrogen Molecules in Diffuse Molecular Clouds

We have modeled the fluorescent pumping of electronic and vibrational emissions of molecular hydrogen (H2) within diffuse molecular clouds that are illuminated by ultraviolet continuum radiation. Fluorescent line intensities are predicted for transitions at ultraviolet, infrared, and red visible wavelengths as functions of the gas density, the visual extinction through the cloud, and the intensity of the incident UV continuum radiation. The observed intensity in each fluorescent transition is roughly proportional to the integrated rate of H2 photodissociation along the line of sight. Although the most luminous fluorescent emissions detectable from ground-based observatories lie at near-infrared wavelengths, we argue that the lower sky brightness at visible wavelengths makes the red fluorescent transitions a particularly sensitive probe. Fabry-Perot spectrographs of the type that have been designed to observe very faint diffuse Ha emissions are soon expected to yield sensitivities that will be adequate to detect H2 vibrational emissions from molecular clouds that are exposed to ultraviolet radiation no stronger than the mean radiation field within the Galaxy. Observations of red H2 fluorescent emission together with cospatial 21 cm H I observations could serve as a valuable probe of the gas density in diffuse molecular clouds.

Neufeld, David A.↗

Vacuum applications of metal foams

Several vacuum applications of copper foams in the density range 2-5% and pore sizes of 0.5-0.7 mm are discussed, such as a foreline hydrocarbon trap in a mechanical vacuum pump, a molecular-flow resistor, a diffuser, and a water injector. Other suggested applications include the use of foam copper in the form of an externally heated plug to remove traces of oxygen from inert gases bled into a vacuum system through a stainless steel line and the use of the porous surface for minimizing release of secondary electrons from electrodes in the path of charged particle beams.

Kendall, B. R. F.↗

Generation of Antibunched Light by Excited Molecules in a Microcavity Trap

The active microcavity is adopted as an efficient source of non-classical light. By this device, excited by a mode-locked laser at a rate of 100 MHz, single-photons are generated over a single field mode with a nonclassical sub-poissonian distribution. The process of adiabatic recycling within a multi-step Franck-Condon molecular optical-pumping mechanism, characterized in our case by a quantum efficiency very close to one, implies a pump self-regularization process leading to a striking n-squeezing effect. By a replication of the basic single-atom excitation process a beam of quantum photon (Fock states) can be created. The new process represents a significant advance in the modern fields of basic quantum-mechanical investigation, quantum communication and quantum cryptography.

DeMartini, F.↗

Wind tunnel mass spectrometer design study

The sampling probe to measure the free stream gas composition in a hypersonic wind tunnel is described. Using a free expansion of the continuum flow, a series of sampling inlet-pumping stages is evaluated. Mass analysis is carried out with a quadrupole mass spectrometer employing a crossed electron beam, molecular beam ion source, and an off-axis electron multiplier. The spatial distribution of the sampled molecular flux and the pumping requirements are evaluated for varying inlet conditions of gas density and flow velocity. The signal-to-noise ratio of the molecular beam formed by this series of coaxial inlets is also determined. The signal-to-noise ratio of the unscattered flux is sufficiently high that an unambiguous determination of the beam composition and of the free stream gas properties can be made. The magnitude of the detected signal is sufficiently high that measurement of trace constituents two orders of magnitude below the primary beam signal can be made.

Hueser, J. E.↗

Better vacuum by removal of diffusion-pump-oil contaminants

The complex problem of why large space simulation chambers do not realize true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance were identified, and some advances in vacuum distillation-fractionation technology were achieved which resulted in a two-decade-or-more lower ultimate pressure. Data are presented to show the overall or individual contaminating effects of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and for reclaiming contaminated oil by high-vacuum molecular distillation are described. Conceptual self-cleansing designs and operating procedures are proposed for modifying large diffusion pumps into high-efficiency distillation devices. The potential exists for application of these technological advancements to other disciplines, such as medicine, biomedical materials, metallurgy, refining, and chemical (diffusion-enrichment) processing.

Buggele, A. E.↗

Space simulation ultimate pressure lowered two decades by removal of diffusion pump oil contaminants during operation

The complex problem why large space simulation chambers do not realize the true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance have been identified and some advances in vacuum/distillation/fractionation technology have been achieved which resulted in a two decade or more lower ultimate pressure. Data are presented to show the overall or individual contaminating effect of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and reclaiming contaminated oil by high vacuum molecular distillation are described.

Buggele, A. E.↗

Proton Pumps: Mechanism of Action and Applications

Recent progress in understanding molecular structures and mechanisms of action of proton pumps has paved the way to their novel applications in biotechnology. Proton pumps, in particular bacteriorhodopsin and ATP synthases, are capable of continuous, renewable conversion of light to chemical, mechanical or electrical energy, which can be used in macro- or nano-scale devices. The capability of protein systems incorporated into liposomes to generate ATP, which can be further used to drive chemical reactions, and to act as molecular motors has been already demonstrated. Other possible applications of such biochemical devices include targeted drug delivery and biocatalytic re actors. All these devices might prove superior to their inorganic alternatives.

Lanyi, Janos K.↗

H2O heating in molecular clouds - Line transfer and thermal balance in a warm dusty medium

An investigation is undertaken into the possibility of the heating of molecular gas through collisions with radiatively pumped H2O, in the context of the overall thermal balance of optically thick molecular clouds with embedded sources. In order to solve the line transfer equation, which includes warm dust grains, an extended method of escape probability approximation is developed in which the equilibrium gas temperature arises from the balance of heating by cosmic ray ionization of H2, and by collisions with warm dust grains and radiatively pumped H2O molecules against cooling by collisions with CO and C I. The equilibrium gas temperature for a given dust temperature strongly depends on the efficiency of the cooling species, and is therefore most sensitive to the cloud optical depth. It is less dependent, in decreasing order, on H2O abundance, gas density, and velocity dispersion.

Takahashi, T.↗

Competition Effect in Atomic-Molecular System

The competition effects among the processes of atomic ionization, optical pumped stimulated radiation (OPSR), four-wave frequency mixing (FWFM) and molecular stimulated diffuse band radiation at the atomic two-photon resonance of 3S approaches 4D in Na2 - Na mixture were observed. The dip at the two-photon resonance in the excitation spectrum for the diffuse-band radiation was interpreted as suppression of population in 4D state.

Jia, Suotang↗

Vibrationally excited molecular hydrogen in Orion

Physical mechanisms for producing vibrationally excited molecular hydrogen, such as has recently been detected toward the Orion Nebula, are discussed. The most likely mechanisms are collisional excitation behind a shock moving into a molecular cloud and near-ultraviolet pumping in the H2 Lyman and Werner bands and subsequent cascade. The absolute intensities of the Orion lines require either a 10-km/s shock moving into a cloud with a density of 300,000 per cu cm or an incident near-UV flux 1 million times the mean interstellar value. The shock model is favored because it matches the observed relative line intensities and because the near-UV source, Theta-1 Ori C, may be too weak to provide the required flux. Intensities of other H2 lines in the shock model are predicted as a further observational discriminant.

Hollenbach, D. J.↗

Vibrational excitation of H2 in intense ultraviolet fluxes

The vibrational excitation of H2 in intense ultraviolet radiation fields is studied. The radiative cascade through bound levels of the ground electronic state, following absorption of Lyman- and Werner-band photons, is modified to include effects of 'multiple pumping' and direct photodissociation from the high vibrational levels. Although the column densities in the excited vibrational levels produced by UV pumping appear too low to explain the recently observed Orion quadrupole emission lines, it is suggested that the far-red lines in the (3-0) and (4-0) bands, produced by UV pumping from O stars near dense molecular clouds, may be detectable.

Shull, J. M.↗

Contamination Control Assessment of the World's Largest Space Environment Simulation Chamber

The Space Power Facility s thermal vacuum test chamber is the largest chamber in the world capable of providing an environment for space simulation. To improve performance and meet stringent requirements of a wide customer base, significant modifications were made to the vacuum chamber. These include major changes to the vacuum system and numerous enhancements to the chamber s unique polar crane, with a goal of providing high cleanliness levels. The significance of these changes and modifications are discussed in this paper. In addition, the composition and arrangement of the pumping system and its impact on molecular back-streaming are discussed in detail. Molecular contamination measurements obtained with a TQCM and witness wafers during two recent integrated system tests of the chamber are presented and discussed. Finally, a concluding remarks section is presented.

Snyder, Aaron↗

Ion-molecule processes in lasers

Three classes of molecular electronic transition lasers produced by hybrid pumping of high pressure rate gas mixtures are discussed. These are (1) rare gas dimer lasers (such as excited Ar2, Kr2, and Xe2) lasing in the VUV, (2) rare gas halide lasers or excimer lasers (such as KrF, ArF, and XeCl excimers) lasing in the UV, and (3) the charge transfer molecular ion laser (such as N2/+/) lasing in the visible range. Laser excitation methods and kinetic sequences are examined for these lasers.

Laudenslager, J. B.↗