At least 55 records · Page 3

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Multi-Scale Multi-physics Methods Development for the Calculation of Hot-Spots in the NGNP

Radioactive gaseous fission products are released out of the fuel element at a significantly higher rate when the fuel temperature exceeds 1600°C in high-temperature gas-cooled reactors (HTGRs). Therefore, it is of paramount importance to accurately predict the peak fuel temperature during all operational and design-basis accident conditions. The current methods used to predict the peak fuel temperature in HTGRs, such as the Next-Generation Nuclear Plant (NGNP), estimate the average fuel temperature in a computational mesh modeling hundreds of fuel pebbles or a fuel assembly in a pebble-bed reactor (PBR) or prismatic block type reactor (PMR), respectively. Experiments conducted in operating HTGRs indicate considerable uncertainty in the current methods and correlations used to predict actual temperatures. The objective of this project is to improve the accuracy in the prediction of local "hot" spots by developing multi-scale, multi-physics methods and implementing them within the framework of established codes used for NGNP analysis.The multi-scale approach which this project will implement begins with defining suitable scales for a physical and mathematical model and then deriving and applying the appropriate boundary conditions between scales. The macro scale is the greatest length that describes the entire reactor, whereas the meso scale models only a fuel block in a prismatic reactor and ten to hundreds of pebbles in a pebble bed reactor. The smallest scale is the micro scale--the level of a fuel kernel of the pebble in a PBR and fuel compact in a PMR--which needs to be resolved in order to calculate the peak temperature in a fuel kernel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on FY18 Testing Results in Support of Integrated EPP-SMT Design Methods Development

Experiments in support of the development of the integrated Elastic Perfectly-Plastic (EPP) analysis with the Simplified Model Test (SMT) design method continued in FY18. The goal of this integrated design method is to incorporate a SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid the separate evaluation of creep and fatigue damage and eliminate the requirement for stress classification in current methods; thus, greatly simplifying evaluation of elevated temperature cyclic service.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Neutron Scattering Evaluation Methods Development at ORNL [Slides]

The goal of the project was to develop a procedure to generate covariance matrix for S( α,β ) data that incorporated both computational simulations and experimental data. Experimental data and computer simulation fit is achieved using the Unified Monte Carlo (UMC) method. The framework is material & simulation method independent, and this is demonstrated using light water. A methodology was developed for generalized generation of covariances for thermal scattering files. The framework was subsequently tested on light water by generating covariance of pDOS with encouraging results. Preliminary results suggest temperature effects of polyethylene may warrant further investigation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microstructural Engineering and Accelerated Test Method Development to Achieve Low Cost, High Performance Solutions for Hydrogen Storage and Delivery

This project made advancements in developing lower cost steel alloys with novel microstructural design for use in hydrogen refueling infrastructure such as storage, compressors, and dispensing components, and utilizing accelerated test methods to efficiently evaluate variations in alloy and microstructure design. The project specifically sought to design alloys with lower nickel contents to reduce alloy cost, which was accomplished through substituting manganese for nickel along with other alloy additions to control deformation characteristics known to be important for hydrogen embrittlement resistance. Through Mn substitutions for nickel, austenitic and duplex austenite-ferrite steels were successfully developed with lower cost than currently available commercial stainless steel products that are employed for hydrogen refueling infrastructure. The steels were processed to achieve comparable strength and toughness in hydrogen environments as the commercially available steels containing high Ni contents. To evaluate mechanical performance in hydrogen, a testing methodology was employed to compare ubiquitous laboratory testing using electrochemical hydrogen charging in a liquid electrolyte to less accessible high pressure gaseous testing. While the application of these steels is in high pressure gaseous environments, the electrochemical hydrogen charging tests produced comparable results. Additionally, the Los Alamos Neutron Scatting Center enabled characterization of deformation mechanisms of the steel alloys in the presence of hydrogen, which has been associated with steel alloy characteristics associated with hydrogen embrittlement. Finally, a fracture mechanics based test bed model was developed to predict the influence of hydrogen gas pressure and fatigue conditions on fatigue lifetimes of pressure vessel steels. Together, these developments can be employed to enable lower cost hydrogen fueling infrastructure and more reliable prediction of steel alloy components in hydrogen service conditions. In particular, the newly alloys have the potential to replace stainless steels, having demonstrated comparable performance at substantially reduced cost.

08 HYDROGEN↗

Method Development for High Temperature In-Situ Neutron Diffraction Measurements of Glass Crystallization on Cooling from Melt

A glass-ceramic borosilicate waste form is being considered for immobilization of waste streams of alkali, alkaline-earth, lanthanide, and transition metals generated by transuranic extraction for reprocessing used nuclear fuel. Waste forms are created by partial crystallization on cooling, primarily of oxyapatite and powellite phases. In-situ neutron diffraction experiments were performed to obtain detailed information about crystallization upon cooling from 1200°C. The combination of high temperatures and reactivity of borosilicate glass with typical containers used in neutron experiments, such as vanadium and niobium, prevented their use here. Thus, methods using sealed thick-walled silica ampoules were developed for the in-situ studies. Unexpectedly, high neutron absorption, low crystal fraction, and high silica container background made quantification difficult for these high temperature measurements. As a follow-up, proof-of-concept measurements were performed on different potential high-temperature container materials, emphasizing crystalline materials so that residual glass in the waste form sample could be more easily analyzed. Room temperature measurements were conducted with a pre-crystallized sample in ‘ideal’ containers stable at low temperatures (i.e., vanadium and thin-wall silica capillaries) and compared to the same measurements in containers stable at high temperatures (i.e, platinum, single crystal sapphire, and thick-walled silica ampoules). Results indicated that Pt is probably the best choice if suitably sealed to prevent contamination from the sample after neutron activation.

36 MATERIALS SCIENCE↗

Accelerating Lipidomic Method Development through in Silico Simulation

Judicious selection of mass spectrometry (MS) acquisition parameters is essential for effectively profiling the broad diversity and dynamic range of biomolecules. Typically, acquisition parameters are individually optimized to maximally characterize analytes from each new sample matrix. This time-consuming process often ignores the synergistic relationship between MS method parameters, producing suboptimal results. Here in this paper, we detail the creation of an algorithm which accurately simulates LC-MS/MS lipidomic data acquisition performance for a benchtop quadrupole-Orbitrap MS system. By coupling this simulation tool with a genetic algorithm for constrained parameter optimization, we demonstrate the efficient identification of LC-MS/MS method parameter sets individually suited for specific sample matrices. Finally, we utilize the in silico simulation to examine how continued developments in MS acquisition speed and sensitivity will further increase the power of MS lipidomics as a vital tool for impactful biochemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Henkin-McGill critical temperature test for explosives revisited: An overview of historical and modern method development

Many overarching standards, regulations, or other requirements necessitate that the critical temperature (T crit ) of an energetic material be known or estimate prior to operations such as heating. However, they rarely, if ever, provide a specific method for doing so. While other methods exist to calculate T crit , such as the Frank-Kamenetskii equation, computer simulation, etc., these cannot be readily utilized for energetics that are physical mixtures (i.e. most pyrotechnics) or materials where detailed material properties required for such calculations are lacking. Here, in this study, a COTS (commercial off-the-shelf) SBAT (Simulated Bulk Auto-ignition Test) apparatus is modified to perform Henkin cookoff tests. This creates a simple, efficient, and cost-effective solution to estimate required T crit values for energetic materials. After a historical overview of the evolution of the Henkin test, several common energetic materials (PETN, RDX, etc.) for which T crit has been readily calculated, and historical data is available, were analyzed for comparison and verification purposes. This was followed by a variety of pyrotechnic mixtures and other materials to where calculation methods cannot be readily used. The modified apparatus, as well as an updated sample shell sealing method, produced results that aligned well with historical data. It also produced reasonable T crit estimates for those materials where the Frank-Kamenetskii equation cannot be applied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SAM Finite Volume Method Development Status Update: GCR Application, Restart, and MultiApp

The System Analysis Module (SAM) is being developed as a modern system analysis code for advanced non-light-water-reactor safety analysis under the U.S. DOE NEAMS program. Previous feasibility studies have demonstrated that a staggered-grid finite volume method (SG-FVM), implemented under the MOOSE framework, can deliver more than an order of magnitude speedup over the existing continuous Galerkin finite element method (CG-FEM) solver for liquid-cooled, incompressible but thermally expandable flow systems. This work extends the previous effort to compressible, gas-cooled reactor applications, where pressure couples directly into the mass equation adding additional nonlinearity into the equation system. New code capabilities are implemented for pebble bed high-temperature gas-cooled reactor (PB-HTGR) analysis, including a pebble bed CoreChannel component, built-in pebble bed effective thermal conductivity model and channel-to-channel crossflow model. The capabilities are tested, benchmarked, and demonstrated for problems with increased level of model and physical complexities, including the HTTU effective thermal conductivity test, the SANA passive cooling test, and a demonstration case using the GPBR200 reactor design covering steady-state operation, DLOFC and PLOFC transients. Across all cases, the SG-FVM solver demonstrated strong robustness and efficiency, and the solutions agree well with reference results and data. The finding of this work proves that SG-FVM is a viable and efficient solver pathway for compressible, gas-cooled reactor system analysis in SAM. In addition, work has been done to successfully support SAM-FVM recover/restart code feature that is essential to reactor safety analysis applications, and MultiApp code feature that is essential to multi-scale and multi-physics simulations. In summary, this work continued from previous feasibility studies, and further demonstrated that the SG-FVM will serve as a strong foundation for SAM’s advanced solver algorithm for future deployment.

Zou, Ling↗

Report on FY17 testing in support of integrated EPP-SMT design methods development

The goal of the proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology is to incorporate a SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid the separate evaluation of creep and fatigue damage and eliminate the requirement for stress classification in current methods; thus greatly simplifying evaluation of elevated temperature cyclic service. The purpose of this methodology is to minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed methodology and to verify the applicability of the code rules, thermomechanical tests continued in FY17. This report presents the recent test results for Type 1 SMT specimens on Alloy 617 with long hold times, pressurization SMT on Alloy 617, and two-bar thermal ratcheting test results on SS316H at the temperature range of 405 °C to 705 °C. Preliminary EPP strain range analysis on the two-bar tests are critically evaluated and compared with the experimental results.

97 MATHEMATICS AND COMPUTING↗

Inverse Sensitivity/Uncertainty Methods Development for Nuclear Fuel Cycle Applications

The Standardized Computer Analyses for Licensing Evaluation (SCALE) software package developed at the Oak Ridge National Laboratory includes codes that propagate uncertainties available in the nuclear data libraries to compute uncertainties in nuclear application performance parameters (responses). We report on our recently commenced eorts to extend this capability to develop an inverse sen- sitivity/uncertainty (IS/U) methodology that identies the improvements in nuclear data that are needed to compute application responses within prescribed tolerances, while minimizing the cost of such data improvements. We report on our progress to date and present a simple test case for our method. Our methodology is directly applicable to thermal and intermediate neutron energy systems because it addresses the implicit neutron resonance self-shielding eects that are essential to accurate modeling of thermal and intermediate systems. This methodology is likely to increase the eciency of nuclear data eorts.

Arbanas, Goran↗

Quantitative analysis of concrete using portable x-ray fluorescence: Method development and validation

During Decommissioning and Demolition (D&D) activities at SRS, it is important that the building be screened for radionuclides and heavy metals to ensure that the proper safety and disposal metrics are in place. A major source of contamination at DOE facilities is the accumulation of mercury contamination, from nuclear material processing and Liquid Waste System (LWS). This buildup of mercury could possibly cause harm to any demolition crew or the environment should this material be released. The current standard method is to take core samples in various places in the facility and use X-ray fluorescence (XRF) to detect the contamination. This standard method comes with a high financial value due to the security levels of these sample facilities with unknown contamination levels. Here in we propose the use of portable XRF units to detect for this contamination on-site. To validate this method, the instrument has to be calibrated to detect the heavy metal contamination, be both precise with the known elemental concentrations and consistent with its actual results of a sample concrete and pristine contaminant, and be able to detect changes in the sample concrete’s composition. After receiving the various concrete samples with their compositions found by a XRF wave-dispersive method, the calibration factor’s linear regressions were adjusted to give the baseline concentration of the concrete with no contamination. Samples of both concrete and concrete/flyash were evaluated; their standard deviations revealed that the measurements were consistent with the known composition. Finally, the samples were contaminated with different concentrations of sodium tungsten dihydrate, allowed to air dry, and measured. When the contaminated samples were analyzed, the heavy metal contamination was seen within the spectrum of the instrument, but there was not a trend of quantification based on the concentration of the solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron Based Microstructural Characterization Method Development for Pu Oxides

Identification of new plutonium oxide signatures is a high priority focus area of the technical nuclear forensics and nonproliferation communities. Comprehensive materials science studies of plutonium oxide are needed to advance the understanding of the microcrystalline properties and their relationship to macro-scale morphologies and signatures. Plutonium oxide particle growth is depenedent on the microcrystalline strucutures, grain size, and orientation. Microcrystalline structures have been found to vary for plutonium oxide based on the oxidation state of plutonium, concentration of reactants, and the physiochemical conditions of precipitation. Empirical observation confirms the relationship between processing conditions and particle morphology. High sensitivity, non destructive analysis of individual microcrystalline grains requires the use of bright sources of X-rays produced by synchrotron radiation, such as those at the Advanced Photon Source. The light source can reveal higher resolution crystallographic mapping, more sensitive chemical analysis, and higher fidelity morphological information than any current methods at SRNL.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Synchrotron Based Microstructural Characterization Method Development for Pu Oxides

Identification of new plutonium oxide signatures is a high priority focus area of the technical nuclear forensics and nonproliferation communities. Comprehensive materials science studies of plutonium oxide are needed to advance the understanding of the microcrystalline properties and their relationship to macro-scale morphologies and signatures. Plutonium oxide particle growth is depenedent on the microcrystalline strucutures, grain size, and orientation. Microcrystalline structures have been found to vary for plutonium oxide based on the oxidation state of plutonium, concentration of reactants, and the physiochemical conditions of precipitation. Empirical observation confirms the relationship between processing conditions and particle morphology. High sensitivity, non destructive analysis of individual microcrystalline grains requires the use of bright sources of X-rays produced by synchrotron radiation, such as those at the Advanced Photon Source. The light source can reveal higher resolution crystallographic mapping, more sensitive chemical analysis, and higher fidelity morphological information than any current methods at SRNL Progress of FY19 was the analysis of the synchrotron data. Areas of focus included XANES oxidation state and EXAFS to measure bond distances with modeling. Most measurements for XANES indicated that the plutonium was in the +4 oxidation state, however, some indicated that there could also be a +5 oxidation state. The EXAFS measurements showed typical Pu – O bonding distance of 2.33 and Pu – Pu bonding distances of 3.81 A; however, some samples also showed that there could be shorter Pu – O distances of approximately 1.81 A, indicative of plutonium in the +5 oxidation state.

36 MATERIALS SCIENCE↗

California GAMA Special Study: Stable isotopic composition of groundwater boron – Analytical method development

Boron is a ubiquitous dissolved constituent in natural waters due to its high solubility, natural occurrence in continental crust, and anthropogenic use in fertilizers, consumer products, and other non-natural sources. The two stable isotopes of boron, 10 B and 11 B (natural abundances ≈ 19.9 and ≈ 80.1 atom percent, respectively), undergo isotopic fractionation due to a variety of chemical processes related to boron speciation ( 10 B is preferentially incorporated into B(OH) 4 - versus B(OH) 3 , e.g. Byrne et al., 2006). The isotopic composition of dissolved boron in groundwater can be used to determine the source(s) of boron; this information can be used to infer the source(s) of other co-migrating contaminants (e.g. nitrate, pharmaceuticals, etc.). Boron behaves as a conservative element in groundwater and surface water systems (Barth, 2000), and the isotopic signature of boron is most useful in conjunction with other stable and radiogenic isotope systems (e.g. δ 18 O, δ 15 N, δ 13 C, 87 Sr/ 86 Sr; Tirez et al., 2010; Widory et al., 2004; Widory et al., 2005) to determine the source(s) of contaminants of interest. We present here a method for boron purification in natural water samples (groundwater, surface water, and seawater) by ion exchange chemistry and measurement of boron isotopic composition by MC-ICP-MS. These methods can be applied to samples with boron concentrations as low as 10 ppb with precision on δ 11 B measurements better than ± 1 ‰. We utilize boron isotopic measurements of boric acid, groundwater, and seawater standards to validate the methods. We also present boron isotopic measurements of San Diego County domestic well samples to demonstrate how these methods can be applied to any study of natural water samples.

07 ISOTOPE AND RADIATION SOURCES↗

Plastic additives in the ocean: Use of a comprehensive dataset for meta-analysis and method development

In excess of 13,000 chemicals are added to plastics (‘additives’) to improve performance, durability, and production of plastic products. They are categorized into numerous chemical classes including flame retardants, light stabilizers, antioxidants, and plasticizers. While research on plastic additives in the marine environment has increased over the past decade, there is a lack of methodological standardization. To direct future measurement of plastic additives, we compiled a first-of-its-kind dataset of literature assessing plastic additives in marine environments, delineated by sample type (plastic debris, seawater, sediment, biota). Using this dataset, we performed a meta-analysis to summarize the state of the science. Currently, our dataset includes 217 publications published between 1978 and May 2023. The majority of publications analyzed plastic additives in biota collected from Europe and Asia. Analyses concentrated on plasticizers, brominated flame retardants, and bisphenols. Common sample preparation techniques included Solvent - Agitation extraction for plastic, sediment, and biota samples, and Solid Phase Extraction for seawater samples with dichloromethane and solvent mixtures including dichloromethane as the organic extraction solvent. Finally, most analyses were performed utilizing gas chromatography/mass spectrometry. There are a variety of data gaps illuminated by this meta-analysis, most notably the small number of compounds that have been targeted for detection compared to the large number of additives used in plastic production. The provided dataset facilitates future investigation of trends in plastic additive concentration data in the marine environment (allowing for comparison to toxicity thresholds) and acts as a starting point for optimizing and harmonizing plastic additive analytical methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗