Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microcalorimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Interfacial Reactivity of Silicon Electrodes: Impact of Electrolyte Solvent and Presence of Conductive Carbon

Silicon (Si) is a promising high-capacity material for lithium-ion batteries; however, its limited reversibility hinders commercial adoption. Approaches such as particle and crystallite size reduction, introduction of conductive carbon, and use of different electrolyte solvents have been explored to overcome these electrochemical limitations. Herein, operando isothermal microcalorimetry (IMC) is used to probe the influence of silicon particle size, electrode composition, and electrolyte additives fluoroethylene carbonate and vinylene carbonate on the heat flow during silicon lithiation. In this work, the IMC data are complemented by X-ray photoelectron and Raman spectroscopies to elucidate differences in solid electrolyte interphase (SEI) composition. Nanosized (~50 nm, n-Si) and micrometer-sized (~4 μm, μ-Si) silicon electrodes are formulated with and without amorphous carbon and electrochemically lithiated in ethylene carbonate (EC), fluoroethylene carbonate (FEC), or vinylene carbonate (VC) based electrolytes. Notably, n-Si electrodes generate 53–61% more normalized heat relative to their μ-Si counterparts, consistent with increased surface area and electrode/electrolyte reactivity. Introduction of amorphous carbon significantly alters the heat flow profile where multiple exothermic peaks and increased normalized heat dissipation are observed for all electrolyte types. Notably, the VC-containing electrolyte demonstrates the greatest normalized heat dissipation of the electrode compositions tested showing as much as a 50% increase compared to the EC or FEC counterparts. The results are relevant to the understanding of silicon negative electrode function in the presence of electrolyte additives and provide insight relative to silicon containing cell reactivity and safety.

25 ENERGY STORAGE↗

dynamics of organic-mineral interactions at the metal oxide-solution interface as studied via binding energetics (Final report)

This project focused on addressing longstanding fundamental and experimental uncertainties on how dissolved organic substances (DOS) interact with metal oxide surface under environmentally relevant conditions. By leveraging a custom-built real-time, in-tandem flow adsorption microcalorimetry-UV-Vis/fluorescence spectroscopy platform, we characterized the binding energetics, kinetics and mechanistic pathways driving DOS-metal oxide interactions at temporal resolution on the order of 1-5 seconds. We studied a diverse suite of model organic compounds/substances – including monocarboxylates (e.g. acetate and benzoate), di-carboxylates (oxalate and succinate), amino acids, amino-based nanparticles and natural organic matter – interacting at the mineral-water interface of structurally- and/or chemically distinct metal oxides (including SiO2, boehmite, ferrihydrite, and γ-Al2O3). Our results indicated that DOS-metal oxide interactions are governed by multi-step reaction pathways, often switching between distinct, resolvable enthalpy- and entropy-driven non-electrostatic or electrostatic configurations. To quantify these interactions, we developed and implemented an analytical workflow that integrates peak deconvolution and Monte-Carlo based error propagation to determine site-specific thermodynamic and kinetic parameters for individual binding/debinding events. In addition to resolving apparent first-order rate constants of each event, we were able to quantify associated apparent equilibrium constants as well as free energy, enthalpy and entropy contribution to the activation and subsequent progression of the binding/debinding process across compounds, compound class and metal oxide surfaces. The kinetic-thermodynamic data produced in this study captured how the interplay between oxide surface reactivity and DOS molecular structure jointly drives binding-debinding dynamics. Notably, that at pH below PZC of the oxide surface, neutral species were heavily involved in monocarboxylate binding, while anionic species drove dicarboxylate binding. Also, that among amino acids 1) positional isomers show distinctive binding characteristics to each other while enantiomers show no significant differences in binding characteristics, 2) molecules that bind via outer-sphere complexation show a larger entropic shift between binding and debinding with no impact on oxide surface while 3) inner-sphere interactions increased anion exchange capacity of the oxide surface. The new insights and data from this work has great potential for improving predictive modeling of carbon dynamics and specifically organic-mineral interactions in environmental and industrial systems.

54 ENVIRONMENTAL SCIENCES↗

Deciphering the Evolution of Current Distribution in Hybrid Silver Vanadium Oxide / Carbon Monofluoride Cathodes within Lithium Primary Batteries

For batteries to function effectively all active material must be accessible requiring both electron and ion transport to each particle. A common approach to generating the needed conductive network is the addition of carbon to create a composite electrode. An alternative approach is the electrochemically induced formation of conductive reaction products where the electrochemically generated materials are in intimate contact with the active material contributing to effective connection of each active particle. Furthermore, this study probes silver vanadium oxide (Ag 2 V 4 O 11 , SVO), carbon monofluoride (CF x ), and hybrid SVO/CF x electrodes in lithium batteries. Ex situ XRD identifies Ag 0 as a reduction product from SVO and LiF from CF x that can be followed as a function of depth-of-discharge (DOD). Spatially-resolved operando energy dispersive x-ray diffraction reveals that the presence of SVO alleviates reaction heterogeneity in the electrodes which are electron transfer limited in the absence of sufficient Ag 0 . Synchrotron X-ray tomography on discharged cathodes reveals the distribution of silver particles where the particles are more closely spaced near the current collector indicating multiple nucleation sites for their formation. Finally, operando isothermal microcalorimetry is used to determine the heat dissipation of the parent and hybrid battery types. Using material enthalpy potentials, we determine the current distribution between the two active materials for the discharging hybrid cathode adding further insight to the diffraction analysis. Taken together, these results provide a comprehensive understanding of hybrid SVO/CF x cathodes and give guidance on optimal compositions that balance power and energy density considerations.

36 MATERIALS SCIENCE↗

Low-Energy Ion Scattering Intensities from Supported Nanoparticles: The Spherical Cap Model

Supported nanoparticles are of great importance to many technologies like fuel processing and chemical synthesis using catalysts and electrocatalysts, energy storage and generation using fuel cells and batteries, electrochemistry, magnetic information storage, and more. Low-energy ion scattering spectroscopy (LEIS) with noble gas ions like He+ is a powerful tool for the characterization of nanoparticles dispersed across flat support surfaces due to its ability to probe the elemental composition in the topmost atomic layer of a surface, providing quantitative information regarding the size and number density of nanoparticles. In this work, we present a derivation of the LEIS intensities expected from nanoparticles and the support material as a function of the average particle size, their number per unit area, and their contact angle with the support when modeled as spherical caps of the nanoparticle material dispersed over the surface of a flat support. The model assumes that the ion intensities are determined only by the physical blocking of linear ion trajectories and independent of the tilt angle of the local surface relative to the incident and scattered ion directions, an assumption we support by quantitative modeling of published data which tested tilt-angle effects. The model is a generalization to arbitrary contact angles of the hemispherical cap model, which assumes 90° contact angle and has been widely used to model spectroscopic signals in LEIS (and also in Auger and photoelectron spectroscopies) during nanoparticle growth. Here, this new model quantitatively reveals how LEIS signals are sensitive not only to the diameter and number density of the nanoparticle but also to their contact angle (or height/diameter ratio). With the use of additional data (e.g., from microscopy or adsorption microcalorimetry), the model presented here will enable more accurate determination of the average size, shape, and number density of supported nanoparticles based on LEIS intensity measurements.

99 GENERAL AND MISCELLANEOUS↗

Unraveling the Intermediate Reaction Complexes and Critical Role of Support-Derived Oxygen Atoms in CO Oxidation on Single-Atom Pt/CeO 2

CeO 2 -supported Pt single-atom catalysts have been extensively studied due to their relevance in automobile emission control and for the fundamental understanding of CeO 2 -based catalysts. Though CeO 2 -supported Pt nanoparticles are often more active than their single-atom counterparts, the former could easily redisperse to Pt single atom under oxidizing diesel conditions. Therefore, to maximize the reactivity of every Pt atom, it is important to fully understand the reaction mechanism of CeO 2 -supported Pt single atoms. Here, we report a CO oxidation study on a Pt/CeO 2 single-atom catalyst, where we can account for all of the neighbors using in situ and operando spectroscopy techniques and microcalorimetric measurements. Coupled with density functional theory calculations, we present a comprehensive picture of the dynamics of the surface species, the role of surface intermediates, and explain the observed reaction kinetics. We started with a catalyst containing exclusively single atoms and used in situ/operando spectroscopy to provide evidence for their stability during the reaction and to identify the Pt 1 complexes before and during the reaction and their binding to CO. The results reveal that in the precatalyst, Pt is present as Pt(O) 4 on the CeO 2 (111) step edge sites, but during CO oxidation, we find that two Pt 1 complexes coexist, representing two states of the same active site in the reaction cycle. The dominant state/complex remains Pt(O) 4 , which adsorbs CO very weakly as shown by CO microcalorimetry. The second, minority state/complex, Pt(CO)(O) 3 is generated through the reaction of Pt(O) 4 with CO, and CO is bound strongly to Pt 1 . Labile oxygen adatoms from the CeO 2 surface play a major role in the regeneration of Pt(O) 4 either directly from Pt(O) 3 or by reaction with the strongly adsorbed CO in Pt(CO)(O) 3 . We show that the formation of an oxygen vacancy and generation of a labile O* are not barrierless, which explains the long lifetime of Pt(CO)(O) 3 and its detectability despite being a minority complex. The results help to develop a comprehensive view of the dynamic evolution of Pt 1 complexes along the reaction cycle and provide mechanistic insights to guide the design of Pt-based single-atom catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Voltage and Temperature Limits of Advanced Electrolytes for Lithium-Metal Batteries

Several advanced electrolytes (mainly ether-based) have recently demonstrated excellent electrochemical performance in high energy density lithium (Li)-metal batteries. However, the safety of these ether-based electrolytes is still unknown. This work evaluates the thermal stability of these new formulations to understand their safety limits of operation in comparison to carbonate electrolytes typically used in Li-ion batteries. Electrolyte stability is assessed in conjunction with LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode and Li-metal anode at ultra-high voltages (≤ 4.8 V) and temperatures (≤ 300°C) to trigger thermal runaway, where onset and extent of heat release are monitored via isothermal microcalorimetry and differential scanning calorimetry Most ether-based electrolytes show improved thermal resilience over commercial carbonate formulations when heated up to 300°C. The thermal behavior in presence of charged cathode and Li-metal suggests that the new electrolytes may be better at stabilizing active material surfaces than carbonate electrolytes. Although extreme voltages severely destabilize the ether-based formulations, prompting thermal runaway, a phosphate based localized high concentration electrolyte exhibits superior stability over commercial carbonate electrolytes at all tested temperatures (32°C, 45°C, and 60°C). Although thermal analysis during the first charge process (as adopted in this preliminary study) may be insufficient to conclude the long-term advantages of these electrolytes, a more stable electrolyte identified under extreme voltage and temperature conditions will provide valuable guidance for the safety of future electrolyte designs.

25 ENERGY STORAGE↗

Importance of High Valence Element Nb in Ni-Rich Layered Cathodes for High-Voltage Lithium-Metal Batteries

Ni-rich layered cathode materials have attracted extensive attention due to their higher energy density and technological maturity in commercialization. As the nickel content is raised, especially surpassing 80%, the increased energy density comes with the tradeoff of diminished thermal stability and increased electrochemical structural instability of the cathode. Compared with Co, Al, B, and Ta, the introduction of high valence element Nb significantly improved the electrochemical cycling, delivering a capacity of 202 mAh/g, corresponding to a capacity retention of 92% after 200 cycles tested at 45 °C. Further, the ex situ differential scanning calorimetry and in situ isothermal microcalorimetry demonstrate that the Nb-modified cathode has the potential to enhance the safety of ultrahigh nickel (Ni) NMCs and displays remarkable resilience to extensive cycling by inhibiting high-temperature decomposition reactions and exhibiting a lower heat flow during electrochemical cycling.

25 ENERGY STORAGE↗

Ion solvation as a predictor of lanthanide adsorption structures and energetics in alumina nanopores

Adsorption reactions at solid-water interfaces define elemental fate and transport and enable contaminant clean-up, water purification, and chemical separations. For nanoparticles and nanopores, nanoconfinement may lead to unexpected and hard-to-predict products and energetics of adsorption, compared to analogous unconfined surfaces. Here we use X-ray absorption fine structure spectroscopy and operando flow microcalorimetry to determine nanoconfinement effects on the energetics and local coordination environment of trivalent lanthanides adsorbed on Al 2 O 3 surfaces. We show that the nanoconfinement effects on adsorption become more pronounced as the hydration free energy, ΔG hydr , of a lanthanide decreases. Neodymium (Nd 3+ ) has the least exothermic ΔG hydr (-3336 kJ·mol -1 ) and forms mostly outer-sphere complexes on unconfined Al 2 O 3 surfaces but shifts to inner-sphere complexes within the 4 nm Al 2 O 3 pores. Lutetium (Lu 3+ ) has the most exothermic ΔG hydr (-3589 kJ·mol -1 ) and forms inner-sphere adsorption complexes regardless of whether Al 2 O 3 surfaces are nanoconfined. Importantly, the energetics of adsorption is exothermic in nanopores only, and becomes endothermic with increasing surface coverage. Changes to the energetics and products of adsorption in nanopores are ion-specific, even within chemically similar trivalent lanthanide series, and can be predicted by considering the hydration energies of adsorbing ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO oxidation on MgAl 2 O 4 supported Ir n : activation of lattice oxygen in the subnanometer regime and emergence of nuclearity-activity volcano

CO oxidation on Pt group metals is affected by the metal size and reducibility of the oxide support. In this study, we report that Ir supported on MgAl 2 O 4 , traditionally considered non-reducible, exhibits properties similar to reducible oxides when the Ir size is in the subnanometer regime. To show this effect, we synthesized subnanometer Ir clusters and compared their properties to single atoms and nanoparticles (1–1.5 nm). The CO oxidation activity is highest on Ir 0.6–0.8nm while showing distinctly different reaction orders in CO and O 2 (0, +0.4), than single atoms (1, 0) and nanoparticles (–1, +1). Microcalorimetry, in situ X-ray absorption, and infrared spectroscopies show that the CO-saturated Ir 0.6–0.8nm clusters could adsorb and activate O 2 despite binding CO more strongly than nanoparticles. Density functional theory calculations on CO saturated Ir 4 clusters suggest that the increased activity is due to the ability to activate O 2 on oxygen vacancies at the Ir–MgAl 2 O 4 interface. The findings show the important effect of the metal nuclearity on the support and catalyst properties and can guide future design of CO oxidation catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Differentiated roles of Lifshitz transition on thermodynamics and superconductivity in La 2- x Sr x CuO 4

The effect of Lifshitz transition on thermodynamics and superconductivity in hole-doped cuprates has been heavily debated but remains an open question. In particular, an observed peak of electronic specific heat is proposed to originate from fluctuations of a putative quantum critical point p* (e.g., the termination of pseudogap at zero temperature), which is close to but distinguishable from the Lifshitz transition in overdoped La-based cuprates where the Fermi surface transforms from hole-like to electron-like. Here we report an in situ angle-resolved photoemission spectroscopy study of three-dimensional Fermi surfaces in La 2- x Sr x CuO 4 thin films ( x = 0.06 to 0.35). With accurate k z dispersion quantification, the said Lifshitz transition is determined to happen within a finite range around x = 0.21. Normal state electronic specific heat, calculated from spectroscopy-derived band parameters, reveals a doping-dependent profile with a maximum at x = 0.21 that agrees with previous thermodynamic microcalorimetry measurements. The account of the specific heat maximum by underlying band structures excludes the need for additionally dominant contribution from the quantum fluctuations at p* . A d -wave superconducting gap smoothly across the Lifshitz transition demonstrates the insensitivity of superconductivity to the dramatic density of states enhancement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Safeguards Technolgy Development Program FY2023 Mid-Year Report

We will develop specific aspects of ultra-high-resolution microcalorimetry that support IAEA NML needs in preparation for transfer of the technology. Two techniques will be considered: gamma spectroscopy for nondestructive isotopic analysis of milligram- to gram-scale uranium and plutonium samples, and decay energy spectroscopy (DES) for isotopic analysis of specially prepared nanogram- to microgram-scale samples of alpha decaying actinides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

FY26 Mid-Year Report

The goal of this project is to develop specific aspects of ultra-high-resolution microcalorimeter technologies that support IAEA Nuclear Material Laboratory needs and the goals of SP-1 19/NML-003 "Microcalorimetry Analysis Technique for NML" but are outside the scope of the SP-1. The focus is on commissioning, assembly, and testing of the microcalorimeter decay energy spectrometer with superconducting transition-edge sensors (TESs) and magnetic microcalorimeters (MMCs) in preparation for transfer to the IAEA Nuclear Material Laboratory.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Chemical contributions to silicon anode calendar aging are dominant over mechanical contributions

Silicon (Si) anodes are a promising candidate for increasing the energy density of lithium (Li)-ion batteries for electric vehicles. However, they have recently been identified as having poor calendar life that is insufficient for commercial needs, in addition to the well-known issue of their poor cycle life resulting from large volume expansion. Here, a specially designed protocol with variable rest periods between intermittent cycling is used to evaluate the impact of the mechanical disruption of Si and solid electrolyte interphase (SEI) from cycling on calendar aging measurements. Si was found to undergo more mechanical degradation during calendar aging with intermittent cycling than graphite. However, Si anode capacity fade was still dominated by time, especially for rest periods greater than or equal to 1 month between cycling. Postmortem dQ/dV half-cell analysis indicated this was mainly due to Li inventory loss and an increase in electrode resistance. Isothermal microcalorimetry further demonstrated that Si passivation is more disrupted than graphite passivation with intermittent cycling and suggested that there may be a chemical buildup of a detrimental species in the electrolyte, leading to a large spike in heat after the Si and SEI are disrupted by cycling.

25 ENERGY STORAGE↗

Kinetics of Open Circuit Processes in Undischarged Li/SOC12 Cells

The kinetics of the heat producing processes in undischarged Li/SOCl2 cells under open circuit conditions were measured by heat-conduction microcalorimetry. The cells studied, Honeywell type G2666 reserve cells, were activated as needed and the rate of open circuit heat output determined as a function of time since activation and temperature. The results at each temperature can be described by an equation of the form q = Bktx where q is the rate of heat output, B is the heat produced per unit of reaction, k and x are empirical constants, and t is the time since activation. Both x and k are found to be functions of temperature; therefore, accelerated testing at elevated temperatures is probably not valid for these cells until the processes involved are better understood.

Hansen, L. D.↗

The application of thermodynamic and spectroscopic techniques to adhesion in the polyimide/Ti 6-4 and polyphenylquinoxaline/Ti 6-4 systems

The results of calorimetric measurements of Ti adherend surfaces are presented. The measurements were carried out after several chemical pretreatments and after fracture of several lap shear samples aged at high temperature. The exact composition of the Ti samples was Ti(6 percent Al-4 percent V). The adhesives used were polyimides and polyphenylquinoxalines (PPQ). Each chemical pretreatment was accompanied by a unique spectroscopic feature which was characterized by XPS, SEM, and specular reflectance infrared spectroscopy. The energetics of the interaction between primer solutions and the Ti adherend were evaluated by microcalorimetry. Changes in the structure of the surface oxide layer upon heating of the adherend were deduced from immersion temperatures of the PI and PPQ solutions. The XPS and SEM data are given is a table.

Dias, S.↗

High resolution X-ray spectroscopy using microcalorimeters

The use of microcalorimeters for high-resolution, high quantum efficiency, nondispersive X-ray spectroscopy has been demonstrated over the past few years. In this paper, the principles of X-ray calorimetry are reviewed, and the results of ongoing X-ray tests using microcalorimetry are summarized. An approach to building an X-ray calorimeter spectrometer is discussed.

Kelley, R. L.↗