Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiple isotope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The combined application of organic sulphur and isotope geochemistry to assess multiple sources of palaeobiochemicals with identical carbon skeletons

Five immature sediments from a Messinian evaporitic basin, representing one evaporitic cycle, were studied using molecular organic sulphur and isotope geochemistry. It is shown that a specific carbon skeleton which is present in different "modes of occurrence" ("free" hydrocarbon, alkylthiophene, alkylthiolane, alkyldithiane, alkylthiane, and sulphur-bound in macromolecules) may have different biosynthetic precursors which are possibly derived from different biota. It is demonstrated that the mode of occurrence and the carbon isotopic composition of a sedimentary lipid can be used to "reconstruct" its biochemical precursor. This novel approach of recognition of the suite of palaeobiochemicals present during the time of deposition allows for identification of the biological sources with an unprecedented specificity.

Non-NASA Center↗

Early Archean Spherule Beds: Chromium Isotopes Confirm Origin through Multiple Impacts of Projectiles of Carbonaceous Chondrite Type: Comment and Reply

This is a exchange in the form of a comment and a reply in regards to an earlier article. The authors of the original article, consider it likely that virtually all of the projectile will condense with the silicate fraction, resulting in very little platinum group element fractionation in the final ejecta deposit. Further, we find no evidence in the commentator's, (i.e., Glikson), comment to support vapor fractionation. We note that the Pd/Ir ratios of published data on 2.56 Ga Hamersley Basin spherules are all greater than in chondrites, contrary to the assertion by Glikson. This is consistent with relatively high Pd concentrations (and Pd/Ir ratios) in crustal rocks.

Kyte, Frank T.↗

Source term estimation using noble gas and aerosol samples

Algorithms that estimate the location, time, and magnitude of a point-source atmospheric release using remotely sampled air concentrations typically use data for a single chemical or radioactive isotope. Here, a Bayesian algorithm is presented that uses data from multiple radioactive isotopes that are all released in the same short-duration event. Data from noble gas and aerosol samplers can be used simultaneously in the model. Application to a large synthetic data set using four isotopes shows the new algorithm generally gives more accurate location and time estimates than a comparable model using a single isotope.

54 ENVIRONMENTAL SCIENCES↗

Xenon Isotopic Analysis of Individual Intermediate Particles From the OSIRIS-REx Sample of Asteroid Bennu

The OSIRIS-REx mission sampled material from the B-type asteroid Bennu and delivered the sample to Earth on 24 September 2023. Here we present initial xenon isotopic analysis of individual intermediate particles of Bennu material collected by the OSIRIS-REx mission. Noble gases are key tracers of Solar System evolution. Xenon is particularly useful among the noble gases because its nine isotopes allow multiple contributing sources to be unambiguously identified. The sun, asteroids (as measured in meteorites), and comets (measured in the coma of comet 67P) have distinct xenon isotopic signatures reflecting different mixtures of nucleosynthetic components. In addition, 129 I, 238 U, and 244 Pu decay with different half-lives, producing characteristic xenon signatures. Exposure of samples containing light rare earth elements and barium to cosmic rays produces xenon from spallation and secondary neutron capture reaction. Noble gas analyses help address several of the driving hypotheses of the mission [9]. Particle-by-particle analysis can elucidate the diversity of material present and reveal distinct noble gas compositions, including the potential to detect presolar or cometary noble gas signatures on a small scale. The isotopic signature provides a fingerprint that can be used to constrain the sources of volatiles in planetary reservoirs and combined with other information (e.g. mineralogy and petrology of the material analyses) contributes to our understanding of the initial constituents, formation, and history of Bennu and its parent asteroid.

S A Crowther↗

Final Measurement of the 235 U Antineutrino Energy Spectrum with the PROSPECT-I Detector at HFIR

This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely 235 U-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. Further, the reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5–7 MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.0 and 3.7 standard deviations the hypotheses that antineutrinos from 235 U are solely responsible and noncontributors to the excess observed at commercial reactors, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pu-238 Production Calculator and Estimation Tool in the Advanced Test Reactor

A MS Excel tool was created to help track Pu-238 production, Np-237 feedstock use, estimate production scenarios, and coordinate planning for shipments at the Idaho National Laboratory (INL) and Advanced Test Reactor (ATR). As-run estimates were used as a basis for beginning and end of life isotopic concentrations. Multiple target types were created to demonstrate a proof of concept while actual results were not yet available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identifying Sources of Sulfate Preserved in High Elevation Lava Tubes From Mauna Loa, Hawaii

Volcanic sulfates record a history of their formation pathways in their triple oxygen isotope compositions, making them a powerful target for understanding atmospheric chemistry. To understand how these isotopic signals may be preserved in sulfate minerals, we investigate multiple O and S isotopes of thenardite, mirabilite, and gypsum from in a Mars analog environment: a pair of lava tubes near the summit of Mauna Loa, Hawaii. Based on 16 O-, 17 O- 18 O compositions, the primary oxygen sources for sulfates in the lava tube are atmospheric oxygen (O 2 ), peroxide (H 2 O 2 ), and ozone (O 3 ). We suggest the isotopic signature of O 2 originates from combustion of reduced sulfur gases and/or elemental sulfur at the eruptive source or within the lava tube soon after skylight collapse. Sulfate with isotopic signatures of peroxide and ozone are typically expected from aqueous reactions in cloud droplets. Chemical modeling indicates the observed proportion of ozone sourced sulfate requires pH greater than ~5.4, higher than measured cloud water pH, instead suggesting the observed O 3 signature could not have formed in cloud water droplets. We interpret that sulfate possessing an ozone signature in the lava tube sulfates formed on wetted surfaces of the lava tubes with alkalinity from alteration of basaltic glass. Furthermore, the oxygen and sulfur isotopes of the sulfate are uncorrelated. Multiple sulfur isotopes ( 32 S- 33 S- 34 S- 36 S) from the Mauna Loa sulfates are consistent with ocean island basalt from Pitcairn, suggesting the sulfate-sulfur has not been modified compared to its volcanic source. The findings of this study indicate that oxidation by ozone plays a key role in the formation of sulfate within lava tubes. We also find that combustion is a significant pathway toward sulfuric acid formation in volcanic environments. Similar signatures should be expected on other planets if volcanism is a significant sulfate source, as has been suggested for Mars. If true, sulfates in returned samples from Mars may hold key information on pO 2 , pCO 2 and planetary scale oxygen fluxes at the time of sulfate formation.

Justin Hayles↗

Pu-238 Production Calculator and Estimation Tool

A MS Excel tool was created to help track Pu-238 production, Np-237 feedstock use, estimate production scenarios, and coordinate planning for shipments. As-run estimates were used as a basis for beginning and end of life isotopic concentrations. Multiple target types were created to demonstrate a proof of concept while actual results were not yet available The initial goals of this production tool were: • Track unirradiated, currently irradiated, and irradiated targets at the Advanced Test Reactor (ATR) • Estimate production yields from irradiated targets in various positions for each cycle • Provide past, current, and future year quantities of Np-237 and Pu-238 at ATR, amounts shipped to ATR and amounts shipped from ATR • Estimate production from current and future target designs based on data from numerical modeling (values will be provided by Idaho National Laboratory (INL)) • After proof of principle, additional work is planned that will further enhance the tool with: o Incorporate the High Flux Isotope Reactor (HFIR) reactor at Oak Ridge National Laboratory (ORNL) for irradiation o Incorporate irradiations and target shipments from ORNL to INL and back to track Np-237 transfers across the Department of Energy (DOE) Complex

07 ISOTOPE AND RADIATION SOURCES↗

Assessment of Modeling and Nuclear Data Needs for Active Neutron Interrogation

This document is the primary deliverable for a scoping study proposed to DOE National Laboratory Announcement Number LAB 19-2114 in the NNSA research area. The study supports user applications employing active neutron interrogation by providing a science plan to improve the modeling capability and the nuclear data that radiation transport codes use. Users rely on the accuracy of the elastic scattering and non-elastic cross-sections spanning thermal energies to 14 MeV (and higher in some cases) for modeling the neutron transport through complex geometries of materials potentially composed of many elements. While the elastic scattering cross-section data are accepted for all commonly occurring elements, the non-elastic cross-section data and the associated emission data include reaction channels that require attention. The study focused on the non-elastic reactions that emit secondary, also known as prompt, gammas with the premise that many users would benefit from improved modeling of these reactions. Many users develop material assay technologies based upon gamma signatures from radiative capture, inelastic scattering, and reactions on low-Z isotopes emitting multiple particles, so the nuclear data gaps, modeling deficiencies, and recommendations for addressing the shortfalls were assessed for these reactions. Fission gammas were excluded from this study because there are other efforts underway to address known shortfalls. Follow-on efforts that successfully execute the recommendations will tangibly improve to the ability to model gamma signatures and backgrounds for user applications, such as controlled substance detection, oil-well logging, and space exploration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Foundations of Molecular 'Isotomics'

The naturally occurring rare isotopes are versions of common elements, such as hydrogen, carbon and oxygen, that contain a larger than usual number of neutrons in their atomic nuclei and therefore are higher in mass than the common atoms of that element. Isotopes exist for most elements and are found in most natural and synthetic materials, but are uneven in their distribution because chemical and physical processes are isotope-selective (e.g., a chemical reaction may proceed more rapidly for one isotope than for another). For this reason, abundances of isotopes in a material of interest can provide a record, or ‘signature’ of various features of that material’s origin and history. These signatures have been used in the geo, life, chemical and physical sciences in a wide variety of ways over close to 8 decades. However, many such applications struggle to reach unique interpretations of isotopic data because multiple factors combine to control a given sample’s overall isotopic content. That is, the factors controlling isotopic content are too numerous and complex to fully constrain from a simple measurement of a material’s isotope abundances. However, the distribution of isotopes within materials, at molecular scales potentially provides a vastly larger number and diversity of constraints on the chemical and physical processes that comprise a material’s history. The rare isotopes may be concentrated into one atomic position in a molecule relative to another, some proportion of molecules in a sample may contain two or more rare isotopes, and those multiply-isotope-substituted forms of molecules may also have uneven distributions of those isotopes across individual atomic sites. For these reasons, even small, seemingly simple molecules, such as sugars, amino acids or drug compounds, actually exist in a vast number of isotopically unique forms (often millions or more), and each one of those forms is in some sense an independent ‘vote’ on that sample’s history. This project has focused on opening this rich archive of information by enabling the creation of routinely and widely applicable ways of measuring and interpreting isotopic structures of molecules. This work has included the development of core technologies and analytical methods, advancing fundamental understanding of the physical and chemical properties of isotopic versions of molecules, and conducting proof of concept studies of illustrative geochemical, cosmochemical and forensic problems in order to show how these technologies, methods and principles come together to solve problems in new ways. A key to the success of this project was the adaptation of ‘Fourier transform mass spectrometry’ (FTMS) to the task of precisely measuring proportions of the rare, naturally occurring isotopic forms of molecules. FTMS is a highly specialized form of mass spectrometry that traps ions within magnetic or electrostatic cavities and, effectively, ‘listens’ (through registering of subtle electrical signals) to the harmonic signals they make while rapidly orbiting within those cavities. These signals have periods that are a function of their mass and strength (or ‘loudness’) that is proportional to their abundances. Thus, these signals constrain relative amounts of molecules that differ in their mass due to various isotopic substitutions. This technology has been essential to the identification of organic molecules in the life, chemical and environmental sciences for over 4 decades, but generally has lacked the control, stability and precision to meaningfully measure rare isotope forms of molecules. This project’s most fundamental contribution has been to modify FTMS, both in terms of hardware and methods, to enable such measurements. The raw data of molecular isotopic structure is tremendously voluminous and complex, so another important activity of this project has been developing the theoretical and data-science tools needed to interpret the data generated by this new form of isotopic measurement. A particularly challenging part of this task has been predicting molecular isotopic structure, as only through the comparison of measurements with predictions can we make progress on hypothesis driven research questions. We have attacked this this prediction task through a combination of first-principles chemical-physics models of the effects of isotope substitution on molecule properties and data-science models that permit us to generalize that chemical physics to cases that have not yet been studied by detailed chemical physics theory. The proof of concept applications we have pursued over the course of this study include biological reactions of amino acids and other biomolecules, non-biological synthesis of organic molecules in extra-terrestrial settings such as meteorites, petroleum geoscience questions concerning the origin and evolution of natural gas, oil and kerogen compounds, and forensic questions such as the sourcing of chemical weapons. The successes of these applications have laid the groundwork for the next phase of this field’s development, which will include larger scale and more ambitious studies of molecular isotopic structure as a means of diagnosing human diseases, such as cancer, and reconstructing detailed interpretations of the origin and evolution of organic molecules in modern and geological environments.

Cesar, Jaime↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Production of NBL PO plutonium isotopic standards CRM 136A, CRM 137A, and CRM 138A

Lawrence Livermore National Laboratory (LLNL) produced approximately 1 mg units of purified Pu from the parent New Brunswick Laboratory (NBL) certified reference materials (CRM) 137, 136 and 138 isotopic standards for the NBL Program Office (NBL PO) as detailed in the revised project plan. As stated in the plan, three representative units of each material were dispensed at the same time to be characterized at LLNL and provide informational values for the quantity of Pu and progeny nuclides in each unit. NBL PO intends to collect and evaluate isotopic measurement data from multiple laboratories and certify these materials as new isotopic standards C137A, C136A, and C138A, respectively. Soon after production eleven units of each analytical standard were shipped to other analytical laboratories for the certification effort, and 121, 119, and 119 units of C137A, C136A and C138A, respectively were shipped to Mickey Finch at Y12 NBL distribution center in November 2024 (30-gallon drum, TID 003777 PRL 7000005043). Residual purified Pu from the effort is being stored indefinitely in B332 at LLNL. Detailed methods can be found in the production plan, and this report describes and documents aspects of the production effort that are not in or were modified from the original production plan.

and nuclear chemistry↗

Temporal Study 2022-2024: Sample-Based Surface Water Dissolved Inorganic Carbon, Dissolved Organic Carbon, Total Nitrogen, Stable Isotopes, and Total Suspended Solids from across Multiple Watersheds in the Yakima River Basin, Washington, USA

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides geochemistry data generated from samples collected at bi-weekly or monthly intervals at six sites across the Yakima River Basin in Washington, USA. Sample and sensor data from previous years (2021-2022) can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1898912 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1892054, respectively. Related sensor data from 2022-2024 will be published separately. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) field metadata; (5) dissolved inorganic carbon (DIC) and averages; (6) dissolved organic carbon (DOC; reported as non-purgeable organic carbon; NPOC) and averages; (7) total dissolved nitrogen (TN) and averages; (8) total suspended solids (TSS); (9) stable isotopes; (10) surface water sampling protocol; (11) sensor protocol; (12) methods codes; and (13) international generic sample number (IGSN) mapping file. All files are .csv or .pdf. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. For data and scripts associated with "Shifts in rain-snow partitioning drive faster water transit times in the US Pacific Northwest" (Butler et al., 2026), go to https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3025481

18-O↗

Multiple Scattering Effects in de/dx-E Instruments for Isotopic Composition Studies

The development of cosmic ray telescopes to separate individual isotopes of heavy elements using the dE/dx-vs.-E technique depends on the incorporation of precise trajectory sensing elements into these systems. In typical implementations the particle trajectory is derived from a set of position measurements made prior to a particle's entering the first energy loss detector. The use of the trajectory obtained in this way to correct energy loss signals for the actual pathlengths through the detectors depends on the assumption that the particle trajectory is a straight line. In order to resolve iron isotopes the angles of incidence, theta the particle track must be known rather accurately.

Wiedenbeck, M. E.↗

A Procedure to Simultaneously Determine the Calcium, Chromium, and Titanium Isotopic Compositions of Astromaterials

Many elements display both linear (mass-dependent) and non-linear (mass-independent) isotope anomalies (relative to a common reservoir). In early Solar System objects, with the exception of oxygen, mass-dependent isotope anomalies are most commonly thought to result from phase separation processes such as evaporation and condensation, whereas many mass-independent isotope anomalies likely reflect radiogenic ingrowth or incomplete mixing of presolar components in the proto-planetary disk. Coupling the isotopic characterization of multiple elements with differing volatilities in single objects may provide information regarding the location, source material, and/or processes involved in the formation of early Solar System solids. Here, we follow up on the work presented in, and detail new procedures developed to make high-precision multi-isotope measurements of Calcium, Chromium, and Titanium with small or limited amounts of sample using thermal ionization mass spectrometry and multi-collector ICP-MS, and characterize a suite of chondritic and terrestrial standards.

Tappa, M. J.↗

The stable isotopes of natural waters at the Marcell Experimental Forest

Here, we present a new data set from the Marcell Experimental Forest (MEF) that compiles water isotope measurements from multiple research catchments, some of which have been studied since the 1960s. The MEF is located in northern Minnesota, USA, and is home to heavily studied and monitored forests, streams, bogs, and fens. Peat-forming systems (bogs and fens) are an important component of the MEF landscape and have a profound impact on the water cycle in these catchments. Within the last decade, analysis of stable isotopes of water (expressed as δD and δ 18 O) has been implemented to characterize the different components of the water budget, and to allow researchers to look at catchment and peatland-specific hydrologic effects in the watershed. This δD and δ 18 O data set of natural waters from MEF catchments is primarily composed of measurements from three peatlands (S1, S2, S6) during an 11-year period. More recently collection and analysis were expanded to also include samples from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) project in the S1 bog, peatlands S3, S4, S5, as well as nearby lakes. We establish a local meteoric water line by analyzing the isotopic composition of precipitation, which fills a void in regional meteoric water lines for Minnesota. Furthermore, we establish baseline isotopic composition for bog outlet streams, bog porewater, aquifer groundwater, overland flow, subsurface stormflow, and snowpack, as well as runoff from the SPRUCE experimental chambers. These data are publicly available and will be expanded upon in the future.

54 ENVIRONMENTAL SCIENCES↗