Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron emission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spin inhibition in γ -decay probabilities for states above S n in Sm and Dy nuclei

When a compound nucleus is formed at an excitation energy above the neutron-separation threshold, it is assumed that its de-excitation will proceed via neutron emission. However, if the excited nucleus is in a high-spin state, but does not have enough excitation energy to conserve angular momentum by either photon emission after neutron emission or relative angular momentum carried off by the neutron, the nucleus will de-excite via γ -emission instead. This effect, the spin inhibition, provides an insight into the structure of the compound nuclei and can aid the understanding of the distribution of the populated spin states in a compound nuclear reaction. In this work, the effects of spin inhibition on the γ-decay probabilities from states in 146,147Sm and 160Dy are presented. For high-spin states above the Sn, spin inhibition is able to suppress neutron emission, and de-excitation via γ -ray emission is observed for states up to 3 MeV above the Sn .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of nonstatistical properties in nuclear structure on emission of prompt fission neutrons

We report the Hauser-Feshbach fission-fragment decay (HF 3 D) model is extended to calculate the prompt fission neutron spectrum (PFNS) for the thermal-neutron-induced fission on 235 U, where the evaporated neutrons from all possible fission-fragment pairs are aggregated. By studying model parameter sensitivities on the calculated PFNS as well as nonstatistical behavior of low-lying discrete level spin distribution, we conclude that discrepancies between the aggregation calculation and the experimental PFNS seen at higher neutron emission energies can be attributed to both the primary fission-fragment yield distribution and the possible high spin states that are not predicted by the statistical theory of nuclear structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energetic particle transport and loss induced by helically-trapped energetic-ion-driven resistive interchange modes in the Large Helical Device

Here, energetic-ion confinement and loss due to energetic-ion driven magnetohydrodynamic modes are studied using comprehensive neutron diagnostics and orbit-following numerical simulations for the Large Helical Device (LHD). The neutron flux monitor is employed in order to obtain global confinement of energetic ions and two installed vertical neutron cameras (VNCs) viewing different poloidal cross-sections are utilized in order to measure the radial profile of energetic ions. A strong helically-trapped energetic-ion-driven resistive interchange mode (EIC) excited in relatively low-density plasma terminated high-temperature state in LHD. Changes in the neutron emission profile due to the EIC excitation are clearly visualized by the VNCs. The reduction in the neutron signal for the helical ripple valley increases with EIC amplitude, which reaches approximately 50%. In addition to the EIC experiment, orbit-following simulations using the DELTA5D code with EIC fluctuations were performed to assess the energetic-ion transport and loss. Two-dimensional temporal evolution results show that the neutron emissivity at the helical ripple decreases significantly due to the EIC. The rapid reduction in neutron emissivity shows that the helically-trapped beam ions immediately escape from the plasma. The reduction in the VNC signals for the helical ripple valley and the total neutron emission rate increase with increasing EIC amplitude, as observed in the experiment. Calculated line-integrated neutron emission results show that the profile measured by VNC1 has one peak, whereas the profile measured by VNC2 has two peaks, as observed in the experiment. Although the neutron emission profile for VNC2 has a relatively wide peak compared with the experimental results, the significant decrease in neutron signal corresponding to the helical ripple valley was successfully reproduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First 𝛽-Delayed Two-Neutron Spectroscopy of the 𝑟-Process Nucleus 134 In and Observation of the 𝑖 13/2 Single-Particle Neutron State in 133 Sn

This manuscript reports on the direct observation of a 𝛽-delayed two-neutron emission in a study of 134 In at the ISOLDE Decay Station using neutron spectroscopy. We also report on the first measurement in 𝛽 − decay of the long-sought 13/2 + excited state in 133 Sn, attributed to be the neutron single-particle 𝑖 13/2 orbital. The observation of sequential neutron emission is used to extract the relative population of the 𝑖 13/2 state, which was found to be much smaller than the predictions of the statistical model. The experiment was possible because of the innovative use of a neutron array with neutron discrimination and interaction tracking capabilities. This is the first study of the details of the two-neutron emission for a nucleus, which belongs to the 𝑟-process path. Understanding 𝛽-delayed two-neutron emission probabilities is essential to validate models used in astrophysical 𝑟-process nucleosynthesis calculations. Observing two-neutron emissions in 𝛽 − decay paves the way for new experiments to study energy and angular correlations for 𝛽-delayed multineutron emitters.

Beta decay↗

Understanding Materials Characteristics of Palladium Lanthanide Cermet Wires as a Mimic of Californium Wire Production

Californium-252 (Cf-252) has been synthesized on a large scale (mg) since the 1970s for use as a portable neutron source. With a half-life of 2.645 years and a spontaneous fission fraction of 3.09%, Cf-252 emits 2.31 × 10 12 neutrons/gram second. Today most of the Cf-252 produced in the world is made at Oak Ridge National Laboratory (ORNL) using the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC). Because of its highly radioactive nature, all manipulations of Cf-252 need to be performed in hot cell facilities by highly trained personnel. The Cf-252 produced at ORNL is done at the REDC, which is conveniently located next to the HFIR. Cf-252 is sold as bulk wire, which has been described as palladium (Pd) metal incasing californium oxide (Cf 2 O 3 ). The process was developed by Mosley et al. at Savannah River Laboratory (SRL) where it was modeled after the thorium work done by Fuschillo et al. This process has been used since the 1970s to synthesize this unique wire, but its fundamental chemistry and materials characteristics were never openly reported. Here we aim to better understand the chemistry and the materials characteristics of Cf-252 wire production for process improvements and to better our fundamental understanding of the mid-late actinides. Though there are many challenges in working with radioactive elements such as Cf, the isotope Cf-252 is even more complicated due to its neutron emission. One challenge with neutron emission is the ability of neutrons to penetrate much deeper through materials, causing radiation damage. This makes using instrumentation to characterize the chemistry and materials properties of this process difficult. For this reason, this study will first focus on terbium (Tb) as a surrogate for Cf. Currently Tb is used as a carrier or filler in Cf production when small amounts of Cf are being processed. This, along with their similar size and charge, makes Tb a reasonable surrogate for this study.

36 MATERIALS SCIENCE↗

Isotopic mass effects of tritium-fueled high-performance TFTR supershots

An increase in total stored energy correlated with the addition of tritium fuel was observed in supershots during the TFTR DT campaign. This supershot regime had strikingly high, centrally peaked ion and electron temperatures, and the largest neutron emission rates observed in TFTR. This paper presents a study of the causes of this increase in stored energy in supershots. Twenty-six supershots have been recently reanalyzed with the TRANSP plasma analysis code. Early TRANSP simulations did not accurately match the measured magnitude and time evolutions of the neutron emission rates. This mismatch is attributed to neglecting apparent increases of trace amounts of heavy impurities during neutral beam injection. The new TRANSP runs were tuned to accommodate this and match the measured global neutron emission rates. These new runs also had improved fidelity in predicting the time histories and radial dependencies of measured DT neutron emission rates. That in turn adds confidence in the simulated thermal deuterium and tritium density profiles that are needed for calculating the average hydrogenic atomic mass profiles. Six subsets of these supershots had well matched toroidal field B tor , plasma current I p , flux geometry, and total injected neutral beam power. The mix of D and T beam ions was varied for different discharges. The magnitude of the increase of the thermal ion energy W i with added tritium was relatively small, and the total W tot increase is dominated by the increase in fast beam ions with T. Analyses at times before the occurrences of deleterious MHD instabilities yielded scaling of W tot with the volume-average isotopic mass consistent with previous publications. The relative fraction of fast energy ions is expected to be small in practical tokamak reactors. Thus the increase in stored energy W tot observed in TFTR supershots does not appear likely to be significantly helpful for producing useful fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compound-Nucleus and Doorway-State Decays of β -Delayed Neutron Emitters K 51 , 52 , 53

We investigated decays of K 51 , 52 , 53 at the ISOLDE Decay Station at CERN in order to understand the mechanism of the β -delayed neutron-emission ( β n ) process. The experiment quantified neutron and γ -ray emission paths for each precursor. We used this information to test the hypothesis, first formulated by Bohr in 1939, that neutrons in the β n process originate from the structureless “compound nucleus.” The data are consistent with this postulate for most of the observed decay paths. The agreement, however, is surprising because the compound-nucleus stage should not be achieved in the studied β decay due to insufficient excitation energy and level densities in the neutron emitter. In the K 53 β n decay, we found a preferential population of the first excited state in Ca 52 that contradicted Bohr’s hypothesis. The latter was interpreted as evidence for direct neutron emission sensitive to the structure of the neutron-unbound state. We propose that the observed nonstatistical neutron emission proceeds through the coupling with nearby doorway states that have large neutron-emission probabilities. The appearance of “compound-nucleus” decay is caused by the aggregated small contributions of multiple doorway states at higher excitation energy. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First measurement in a magnetic confinement fusion experiment of the H 3 + H 3 → He 5 + n intermediate two-body resonant reaction

We report on the first experimental measurements made at a magnetic confinement fusion device of the tritium(T)-tritium(T) reaction T + T → He 4 + 2 n indicating the presence of the intermediate two-body resonant reaction T + T → He 5 + n . During the second deuterium-tritium campaign (DTE2) at the Joint European Torus, measurements of fusion plasmas with high tritium concentrations, n T / ( n T + n D ) ≈ 0.99 , heated with tritium neutral beam injection, were performed using the neutron time-of-flight (TOF) spectrometer TOFOR. We detect a peak in the neutron emission TOF spectrum consistent with the two-body resonant reaction. The TT neutron emission energy spectrum is modeled using an R -matrix framework where the distributions of the most likely model parameters given our experimental TOF data are determined utilizing a Markov chain Monte Carlo approach. We compare our best estimate of the T + T neutron emission energy spectrum with results obtained at inertial confinement fusion experiments at the OMEGA facility and find a spectral shape that is consistent with the energy dependency in the neutron spectrum observed at OMEGA. Published by the American Physical Society 2024

Physics↗

Measuring the β-decay Properties of Neutron-rich Exotic Pm, Sm, Eu, and Gd Isotopes to Constrain the Nucleosynthesis Yields in the Rare-earth Region

Abstract The β -delayed neutron-emission probabilities of 28 exotic neutron-rich isotopes of Pm, Sm, Eu, and Gd were measured for the first time at RIKEN Nishina Center using the Advanced Implantation Detector Array (AIDA) and the BRIKEN neutron detector array. The existing β -decay half-life ( T 1/2 ) database was significantly increased toward more neutron-rich isotopes, and uncertainties for previously measured values were decreased. The new data not only constrain the theoretical predictions of half-lives and β -delayed neutron-emission probabilities, but also allow for probing the mechanisms of formation of the high-mass wing of the rare-earth peak located at A ≈ 160 in the r -process abundance distribution through astrophysical reaction network calculations. An uncertainty quantification of the calculated abundance patterns with the new data shows a reduction of the uncertainty in the rare-earth peak region. The newly introduced variance-based sensitivity analysis method offers valuable insight into the influence of important nuclear physics inputs on the calculated abundance patterns. The analysis has identified the half-lives of 168 Sm and of several gadolinium isotopes as some of the key variables among the current experimental data to understand the remaining abundance uncertainty at A = 167–172.

79 ASTRONOMY AND ASTROPHYSICS↗

Proton emission in ultraperipheral Pb-Pb collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 5.02 TeV

The first measurements of proton emission accompanied by neutron emission in the electromagnetic dissociation (EMD) of 208 Pb nuclei in the ALICE experiment at the Large Hadron Collider are presented. The EMD protons and neutrons emitted at very forward rapidities are detected by the proton and neutron zero degree calorimeters of the ALICE experiment. The emission cross sections of zero, one, two, and three protons accompanied by at least one neutron were measured in ultraperipheral 208 Pb − 208 Pb collisions at a center-of-mass energy per nucleon pair $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 5.02TeV. The 0p and 3p cross sections are described by the RELDIS model within their measurement uncertainties, while the 1p and 2p cross sections are underestimated by the model by 17–25%. According to this model, these 0p, 1p, 2p, and 3p cross sections are associated, respectively, with the production of various isotopes of Pb, Tl, Hg, and Au in the EMD of 208 Pb . The cross sections of the emission of a single proton accompanied by the emission of one, two, or three neutrons in EMD were also measured. The data are significantly overestimated by the RELDIS model, which predicts that the (1p,1n), (1p,2n), and (1p,3n) cross sections are very similar to the cross sections for the production of the thallium isotopes 206,205,204 Tl.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron source reconstruction using a generalized expectation–maximization algorithm on one-dimensional neutron images from the Z facility

Magnetized Liner Inertial Fusion experiments have been performed at the Z facility at Sandia National Laboratories. These experiments use deuterium fuel, which produces 2.45 MeV neutrons on reaching thermonuclear conditions. To study the spatial structure of neutron production, the one-dimensional imager of neutrons diagnostic was fielded to record axial resolved neutron images. In this diagnostic, neutrons passing through a rolled edge aperture form an image on a CR-39-based solid state nuclear track detector. In this report we present a modified generalized expectation–maximization algorithm to reconstruct an axial neutron emission profile of the stagnated fusion plasma. We validate the approach by comparing the reconstructed neutron emission profile to an x-ray emission profile provided by a time-integrated pinhole camera.

47 OTHER INSTRUMENTATION↗

The effects of low- Z shielding on uranium isotope discrimination using the time-emission profiles of long-lived delayed neutrons

Characteristic radiation signals can often be obscured or distorted by relatively small amounts of shielding, as is the case for highly-enriched uranium (HEU). Methods that can detect and identify special nuclear material (SNM) even in the presence of shielding are therefore of high value in many nuclear security and nonproliferation applications. It has been previously shown that the buildup and decay time profiles of long-lived delayed neutron emission from induced fission are unique and can be used to successfully discriminate between uranium isotopes and infer enrichment without the need for a calibration standard. Because the long-lived delayed neutron precursors exhibit decay times on the order of tens of seconds, their time profiles are not sensitive to the delays associated with scattering or diffusion in shielding materials, which occur on much shorter time scales. The use of capture-based neutron detectors can also mitigate the effects of shielding, because unlike recoil-based detectors, they do not have a low-energy detection threshold, so that neutrons that lose their energy in the shielding are still detectable. In this work, the effects of low-Z shielding on the discrimination of uranium isotopes using delayed neutron time profile measurements are investigated for the first time. Furthermore, the delayed neutron buildup and decay time profiles of polyethylene-shielded HEU and depleted uranium objects are measured using two different capture-gated detector designs. The recorded profiles show good agreement with the shapes predicted from six-group delayed neutron models even with the shielding in place, and the enrichment of the HEU and DU objects was estimated accurately to within 5%. While this method shows potential for discriminating and characterizing extreme cases of enrichment when a moderate amount of shielding is present, simulation results suggest that significant limitations exist for intermediate enrichment levels due to distortions to the delayed neutron time profile caused by neutron reflection in the shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

$\overline{TKE}$ Parameterization and $\bar{v}$ Uncertainty Analysis for CGMF

Previous work was performed on tuning CGMF parameters for 235 U, 238 U, and Plutonium isotopes. Now work is being done to tune minor uranium isotopes. However, uranium isotopes like 232 U and 236 U have almost no experimental data. We are applying cross-isotope models to extrapolate and tune CGMF on isotopes that lack experimental data. There exist several internal CGMF physics quantities that affect the output of CGMF—multi-chance fission probability, excitation energy sharing, spin-cutoff factor, spin scaling, and fragment total kinetic energy to name a few. The mean fragment total kinetic energy, $\overline{TKE}$, is particularly interesting because of its strong anti-correlation with $\bar{v}$. We are most interested in the mean fragment total kinetic energy before neutron emissions. $\overline{TKE}$ is assumed to be pre-neutron emission unless otherwise stated. Currently in CGMF, the $\overline{TKE}$ model for 233,234,235,238 U are tuned independently to reproduce ν for the associated isotopes. In this report, we will tune a cross-isotope $\overline{TKE}$ model to experimental $\overline{TKE}$ data for 232,233,234,235,236,238 U. Because of the unreliable and sparse nature of $\overline{TKE}$ experimental data, future work will use more reliable experimental $\bar{v}$ data to infer the $\overline{TKE}$ model (and likely other internal CGMF parameters) for uranium isotopes. Such work has been performed previously using a sensitivity analysis and Kalman filter methods.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of Newly Measured 𝛽-Delayed Neutron Emitters around 78 Ni on Light Element Nucleosynthesis in the Neutrino Wind Following a Neutron Star Merger

Neutron emission probabilities and half-lives of 37 𝛽-delayed neutron emitters from 75 Ni to 92 Br were measured at the RIKEN Nishina Center in Japan, including 11 one-neutron and 13 two-neutron emission probabilities and six half-lives for the first time that supersede theoretical estimates. These nuclei lie in the path of the weak 𝑟 process occurring in neutrino-driven winds from the accretion disk formed after the merger of two neutron stars synthesizing elements in the 𝐴∼80 abundance peak. The presence of such elements dominates the accompanying kilonova emission over the first few days and have been identified in the AT2017gfo event, associated to the gravitational wave detection GW170817. Abundance calculations based on over 17,000 simulated trajectories describing the evolution of matter properties in the merger outflows show that the new data lead to an increase of 50%–70% in the abundance of Y, Zr, Nb, and Mo. This enhancement is large compared to the scatter of relative abundances observed in old very metal poor stars and thus is significant in the comparison with other possible astrophysical processes contributing to the light-element production. These results underline the importance of including experimental decay data for very neutron-rich 𝛽 -delayed neutron emitters into 𝑟 -process models.

59 ≤ A ≤ 89↗

High repetition-rate 0.5 Hz broadband neutron source driven by the Advanced Laser Light Source

Neutron beams are an essential tool to investigate material structure and perform nondestructive analysis, as they give unique access to element composition, thus ideally complementing density analysis allowed by standard x-rays investigation. Laser-driven neutron sources, though compact and cost-effective, currently have lower average flux than conventional neutron sources, due to the limited repetition rate of the lasers used so far. However, advancements in laser technology allow nowadays to address this challenge. Here, we report results obtained at the Advanced Laser Light Source characterizing stable production of broadband (0.1–2 MeV) neutrons produced at a high repetition rate (0.5 Hz). The interaction of laser pulses of 22 fs duration and 3.2 J on-target energy with 2-μm-thick tantalum targets produced protons in the Target Normal Sheath Acceleration (TNSA) regime up to 7.3 MeV. These protons were subsequently converted into neutrons by (p,n) reactions in lithium fluoride (LiF). Activation measurements and bubble detectors were used to characterize neutron emissions, with a neutron fluence of up to ∼1.4×105 neutrons/shot/sr and energies mainly between a few hundred of kilo-electron volt and 2 MeV. The total neutron yield was ∼5×105 neutrons/shot. This paves the way for numerous applications, e.g., in homeland security, materials science, or cultural heritage.

Physics↗

A Technical basis for in-house calibration of 252 Cf neutron source emission rates

10CFR835 stipulates that radiation protection instruments must be calibrated at least annually. Accordingly, calibration of dose rate instruments are reliant on well-known reference fields. The neutron-free-in-air facility (NFIA) located at TA36-0214 provides such a capability for neutron remmeters. One of the reference NFIA sources, 252 Cf, must be replaced every 8-10 years due to its relatively short half-life (2.645 ± 0.008 y). In the past, each newly purchased 252 Cf source has been calibrated at NIST using the Mn-bath technique prior to shipping to LANL. However, because of COVID-19 complications, the most recently acquired 252 Cf source (FTC-CF-7167) has been stored at LANL pending approval to ship to NIST for calibration. Due to the considerable expense in transporting the source to and from NIST, this TBD was written to demonstrate that new sources can be accurately calibrated via intercomparison measurements with older NIST-calibrated 252 Cf sources. It had been previously noted that such measurements yielded emission rates that agreed very well with the official rates established by NIST

252cf↗

Numerical assessment of the impact of the guiding-centre approximation on fast ion simulations in NSTX

Guiding-centre (GC) and full-orbit (FO) simulations of the beam-injected fast ion distribution and the corresponding neutron emissivity have been carried out for magnetohydrodynamics-quiescent National Spherical Torus eXperiment (NSTX) plasmas, using a combination of ASCOT5 and DRESS, to assess the suitability of the GC approximation for fast ions in NSTX. It was found that GC and FO simulations predicted substantially different steady-state distributions in both position and velocity space and different neutron emissivity profiles, leading to a 15% reduction in the predicted global neutron rate for FO relative to GC. These changes accompany a higher magnetic moment in FO, and correspond to a change in particle orbits from co-passing to trapped and stagnation orbits. ASCOT5 was also benchmarked against TRANSP/NUBEAM with input loaded entirely from TRANSP/NUBEAM output files, with agreement found between the GC simulations when finite Larmor radius (FLR) corrections were omitted. ASCOT5 FO and TRANSP/NUBEAM with FLR produced fast ion distributions which differed in localised regions, but predicted global neutron rates which agree within 3%.

ASCOT↗