Search NASA⌕ Search

SEARCH · Search NASA

Results for “PMMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Fracture of PC and PMMA cylinders in the Taylor tests

The present paper analyzes failure observed in polymer rods collided with a steel anvil under the Taylor cylinder impact experiments. The experimental and numerical analysis demonstrates that association of the failure patterns with the loading mode depends on the rod material. Two materials are considered in the paper, specifically, polymethylmethacrylate (PMMA) and polycarbonate (PC). Damage in PMMA rods at the Taylor tests is shown to be dominated by the shear load resulting in plastic deformation. In contrast, the major mechanism of damage in PC rods is governed by omni-directional (pressure) mode of load. Analysis of the damage in sections of the rods associated with the glass transition is also addressed in the present theoretical study. Failure in these polymers follows the traditional fracture wave mechanism for brittle glass-type materials due to load in the corresponding mode. Numerical analysis employs a two-phase model with improved inter-phase thermal balance accounting for the inter-phase mass, momentum, and heat exchanges during the glass phase transition, while damage being accumulated in time. In conclusion, the simulation results demonstrate a good correlation with the experimental results.

36 MATERIALS SCIENCE↗

Measuring the x-ray irradiated degradation of PMMA through FTIR and 2D-COS analysis

To combat issues arising from polymer aging studies which include wasting valuable time and resources, Two-Dimensional Correlation Spectroscopy (2D-COS) has been observed to identify accelerated aging conditions in materials in a very short timeframe. This study is attempting to validate 2D-COS as a viable technique for aging studies by measuring the degradation of PMMA via x-ray radiation. PMMA has been previously observed to degrade via main chain scission under x-ray radiation, and similar results have possibly been seen in this study. More work needs to be done to collect reliable data, including finalizing a standard operating procedure and normalizing raw data so that noise is not recognized as spectral change by the extremely sensitive 2D-COS software.

36 MATERIALS SCIENCE↗

Phase holograms in PMMA with proximity effect correction

Complex computer generated phase holograms (CGPH's) have been fabricated in PMMA by partial e-beam exposure and subsequent partial development. The CGPH was encoded as a sequence of phase delay pixels and written by the JEOL JBX-5D2 E-beam lithography system, a different dose being assigned to each value of phase delay. Following carefully controlled partial development, the pattern appeared rendered in relief in the PMMA, which then acts as the phase-delay medium. The exposure dose was in the range 20-200 micro-C/sq cm, and very aggressive development in pure acetone led to low contrast. This enabled etch depth control to better than plus or minus lambda(sub vis)/60. That result was obtained by exposing isolated 50 micron square patches and measuring resist removal over the central area where the proximity effect dose was uniform and related only to the local exposure. For complex CGPH's with pixel size of the order of the e-beam proximity effect radius, the patterns must be corrected for the extra exposure caused by electrons scattered back up out of the substrate. This has been accomplished by deconvolving the two-dimensional dose deposition function with the desired dose pattern. The deposition function, which plays much the same role as an instrument response function, was carefully measured under the exact conditions used to expose the samples. The devices fabricated were designed with 16 equal phase steps per retardation cycle, were up to 1 cm square, and consisted of up to 100 million 0.3-2.0 micron square pixels. Data files were up to 500 MB long and exposure times ranged to tens of hours. A Fresnel phase lens was fabricated that had diffraction limited optical performance with better than 85 percent efficiency.

Maker, Paul D.↗

Experimental Observations of PMMA Spheres Burning at Reduced Gravity

Polymer combustion is a very complicated process which involves the coupling of gas-phase combustion, melting, pyrolysis, and possible charring of the condensed phase. Although only a few studies on the combustion of a spherically shaped polymer have been conducted, there is renewed interest in the subject. At the Third International Microgravity Combustion Workshop, we presented a preliminary experimental plan and proposed an apparatus to study the combustion of a PolyMethylMethAcrylate (PMMA) sphere at reduced gravity. In this paper, we describe the experimental hardware in detail, summarize our observations since the last workshop, and describe future studies. The main objective is to determine the burning rate of PMMA spheres at reduced gravity under different ambient oxygen concentrations and total pressures. The dependence of the burning rate on the initial sphere diameter will be examined. It is anticipated that the simple spherical geometry in conjunction with reduced gravity will facilitate an assessment of the effect of condensed phase behavior on polymer burning processes and can be used as a means to test polymer combustion models.

Yang, Ji-Ann C.↗

Fracture Toughness of PMMA as Measured with Indentation Cracks

Fracture toughness of polymethyl methacrylate (PMMA) was evaluated with indentation cracks. The cracks were developed by indenting in a liquid acetone environment, as suggested by previous researchers. Due to the inconsistency in crack configurations with varying indentation loads and to the negligible residual stress from indentation, the application of the indentation strength method was limited in evaluating fracture toughness of PMMA. The semi-elliptical crack approximation, however, particularly at a low indentation load of 9.8 N, resulted in reasonable agreement with the value determined by three conventional fracture toughness testings using the compact tension (CT), double cantilever beam (DCB), and single edge notched beam (SENB) specimens. Measurements at other indentation load typically were in poor agreement with conventional methods due to poorly developed crack configurations.

Choi, S. R.↗

Low Stretch PMMA Burning in Microgravity: Status of the Ground-Based Program and New ISS Glovebox Experiment SALSA

The objective of this ground-based program is to study low stretch diffusion flames burning PMMA as the solid fuel to determine the relationship between buoyant low stretch burning in normal gravity and forced flow low stretch burning in microgravity. The low stretch is generated in normal gravity by using the buoyant convection induced by burning the bottom of a large radius of curvature sample. Low stretch is also generated using the Combustion Tunnel drop tower rig (2.2 and 5.2 second facilities), which provides a forced convective low velocity flow past smaller radius of curvature samples. Lastly, an ISS glovebox investigation is being developed to study low stretch burning of PMMA spheres to obtain long duration testing needed to accurately assess the flammability and burning characteristics of the material in microgravity. A comparison of microgravity experiment results with normal gravity test results allows us to establish a direct link between a material's burning characteristics in normal gravity (easily measured) with its burning characteristics in extraterrestrial environments, including microgravity forced convective environments. Theoretical predictions and recent experimental results indicate that it should be possible to understand a material's burning characteristics in the low stretch environment of spacecraft (non-buoyant air movement induced by fans and crew disturbances) by understanding its burning characteristics in an equivalent Earth-based low stretch environment (induced by normal gravity buoyancy). Similarly, Earth-based stretch environments can be made equivalent to those in Lunar- and Martian-surface stretch environments (which would induce partial-gravity buoyancy).

Olson, S. L.↗

Integrity of Polymethylmethacrylate (PMMA) Chemically Welded Joints Examined

NASA Glenn Research Center s Capillary Flow Experiments (CFE) program is developing experiment payloads to explore fluid interfaces in microgravity on the International Space Station. The information to be gained from the CFE is relevant to the design of fluid-bearing systems in which capillary forces predominate, for example in the passive positioning of liquids in spacecraft fuel tanks. To achieve the science goals of CFE, Glenn researchers constructed several types of experiment vessels. One type of vessel, known as the interior corner flow (ICF), will be used to determine important transients for low-gravity liquid management in a two-phase system. Each vessel has a cylindrical fluid reservoir connected to each end of the test chamber by internal transport tubes, each with a quarter-turn shutoff valve (see the following photograph). These multipiece vessels are made from polymethylmethacrylate (PMMA) because of its excellent optical properties (i.e., the fluids can be observed easily in the vessel). Because of the complexity of certain vessels, the test chamber had to be manufactured in pieces and welded chemically. Some past experience with adhesive bonded plastic showed that the experiment fluid degraded the adhesive to the point of failure. Therefore, it was necessary to see if the fluid also degraded the chemically welded PMMA joints.

Lerch, Bradley A.↗

Polymethylmethacrylate (PMMA) Material Test Results for the Capillary Flow Experiments (CFE)

In support of the Capillary Flow Experiments (CFE) program, several polymethylmethacrylate (PMMA) flight vessels were constructed. Some vessels used a multipiece design, which was chemically welded together. Due to questions regarding the effects of the experiment fluid (silicone oil) on the weld integrity, a series of tests were conducted to provide evidence of the adequacy of the current vessel design. Tensile tests were conducted on PMMA samples that were both in the as-received condition, and also aged in air or oil for up to 8 weeks. Both welded and unwelded samples were examined. Fracture of the joints was studied using notched tensile specimens and Brazilian disk tests. Results showed that aging had no effect on tensile properties. While the welded samples were weaker than the base parent material, the weld strength was found to be further degraded by bubbles in the weld zone. Finally a fracture analysis using the worst-case fracture conditions of the vessel was performed, and the vessel design was found to have a factor of three safety margin.

Lerch, Bradley A.↗

Mixed Convection Blowoff Limits as a Function of Oxygen Concentration and Upward Forced Stretch Rate for Burning Pmma Rods of Various Sizes

Normal gravity flame blowoff limits in an axisymmetric pmma rod geometry in upward axial stagnation flow are compared with microgravity Burning and Suppression of Solids II (BASS-II) results recently obtained aboard the International Space Station. This testing utilized the same BASS-II concurrent rod geometry, but with the addition of normal gravity buoyant flow. Cast polymethylmethacrylate (pmma) rods of diameters ranging from 0.635 cm to 3.81 cm were burned at oxygen concentrations ranging from 14 to 18 by volume. The forced flow velocity where blowoff occurred was determined for each rod size and oxygen concentration. These blowoff limits compare favorably with the BASS-II results when the buoyant stretch is included and the flow is corrected by considering the blockage factor of the fuel. From these results, the normal gravity blowoff boundary for this axisymmetric rod geometry is determined to be linear, with oxygen concentration directly proportional to flow speed. We describe a new normal gravity upward flame spread test method which extrapolates the linear blowoff boundary to the zero stretch limit to resolve microgravity flammability limits, something current methods cannot do. This new test method can improve spacecraft fire safety for future exploration missions by providing a tractable way to obtain good estimates of material flammability in low gravity.

blowoff↗

Optical and Mechanical Properties of Nanocomposite Films Based on Polymethyl Methacrylate (PMMA) and Fumed Silica Nanoparticles

Nanocomposite polymer films are prepared by using ultrasonic spray deposition (USD) technique through mixing polymethyl methacrylate as matrix and fumed silica nanoparticles as second phase in dimethyl carbonate solvent. Annealing procedure improves the film uniformity and optical transmission. The addition of fumed silica nanoparticles impedes the transmission of the electrolyte films due to agglomeration of fumed silica nanoparticles. Adding surfactant, cetyltrimethylammonium bromide, disperses the fumed silica nanoparticles and retrieves the optical transmission of nanocomposite polymer films to around 90%. The hardness and elastic modulus of the nanocomposite polymer films are better than the commercial bulk. The USD deposited nanocomposite polymer film comprises of PMMA and fumed silica nanoparticles is a promising candidate of solid-state electrolyte for EC windows application.

36 MATERIALS SCIENCE↗

Comparison of MCNPX and GEANT4 to Predict the Contribution of Non-elastic Nuclear Interactions to Absorbed Dose in Water, PMMA and A150

Proton induced non-elastic nuclear reactions play an important role in the dose distribution of clinically used proton beams as they deposit dose of high biological effectiveness both within the primary beam path as well as outside the beam to untargeted tissues. Non-elastic nuclear reactions can be evaluated using transport codes based on the Monte Carlo method. In this work, we have utilized the Los Alamos code MCNPX and the CERN GEANT4 toolkit, which are currently the most widely used Monte Carlo programs for proton radiation transport simulations in medical physics, to study the contribution of non-elastic nuclear interactions to the absorbed dose of proton beams in the therapeutic energy range. The impact of different available theoretical models to address the nuclear reaction process was investigated. The contribution of secondary particles from non-elastic nuclear reactions was calculated in three materials relevant in radiotherapy applications: water, PMMA and A150. The results evidence that there are differences in the calculated contribution of the secondary particles heavier than protons to the absorbed dose, with different approaches to model the nuclear reactions. The MCNPX calculation give rise to a larger contribution of d, t, {alpha}{sup 3}He to the total dose compared to the GEANT4 physical models chosen in this work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Free Volume Related Fluorescence Properties of Electron Irradiated Chalcone Doped PMMA Films

Effect of electron irradiation on free volume related fluorescence properties of chalcone doped Poly(methyl methacrylate)(PMMA) composite films have been studied using Positron Annihilation and Fluorescence spectroscopic techniques. In this polymer composite, enhancement of fluorescence at lower doses and reduction at higher doses has been observed under electron irradiation. From Positron annihilation studies suggests that at lower doses of irradiation induced crosslinking which affect the free volume properties and inturn hinders the chalcone molecular rotation. At higher doses chain scission process affect matrix relaxation. Under the restricted condition the chromophore molecules likely to emit enhanced fluorescence and its mobility is directly related to the free volume around it.

36 MATERIALS SCIENCE↗

Modification of a new polymer photorecording material based on PMMA doped with 2,2-difluoro-4-(9-antracyl)-6-methyl-1,3,2-dioxaborine by ultrashort pulses

Specific features of modification of a new photorecording material based on PMMA doped with 2,2-difluoro-4-(9-antracyl)-6-methyl-1,3,2-dioxaborine are studied. The recording of the filament distribution in the studied material occurs at the expense of two-photon photochemical processes. The three-dimensional modification of the material is achieved in the filamentation regime without supercontinuum generation. It is possible to order the volume structure by preliminary photo-modification of the near-surface layer of the material. (extreme light fields and their applications)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technical Note: Partial body irradiation of mice using a customized PMMA apparatus and a clinical 3D planning/LINAC radiotherapy system

Purpose: In vivo radiobiology experiments involving partial body irradiation (PBI) of mice are of major importance because they allow for the evaluation of individual organ tolerance; overcoming current limitations of experiments using lower dose, whole body irradiation. In the current study, the authors characterize and validate an effective and efficient apparatus for multiple animal PBI, directed to the head, thorax, or abdomen of mice. Methods: The apparatus is made of polymethylmethacrylate and consists of a rectangular parallelepiped prism (40 cm × 16 cm × 8 cm), in which five holes were drilled to accomodate standard 60 ml syringes, each housing an unanesthetized, fully immobilized mouse. Following CT-scanning and radiotherapy treatment planning, radiation fields were designed to irradiate the head, thorax, or abdomen of the animal. Thermoluminescent dosimeters (TLDs) were used to confirm the treatment planning dosimetry for primary beam and scattered radiation. Results: Mice are efficiently placed into 60 ml syringes and immobilized, without the use of anesthetics. Although partial rotational movement around the longitudinal axis and a minor 2 mm forward/backward movement are permitted, this does not compromise the irradiation of the chosen body area. TLDs confirmed the dose values predicted by the treatment planning dosimetry, both for primary beam and scattered radiation. Conclusions: The customized PMMA apparatus described and validated is cost-effective, convenient to use, and efficient in performing PBI without the use of anesthesia. The developed apparatus permits the isolated irradiation of the mouse head, thorax, and abdomen. Importantly, the apparatus allows the delivery of PBI to five mice, simultaneously, representing an efficient way to effectively expose a large number of animals to PBI through multiple daily fractions, simulating clinical radiotherapy treatment schedules.

60 APPLIED LIFE SCIENCES↗

SU-F-J-202: Secondary Radiation Measurements for Charged Particle Therapy Monitoring: Fragmentation of Therapeutic He, C and O Ion Beams Impinging On a PMMA Target

Purpose: In Charged Particle Therapy (CPT), besides protons, there has been recently a growing interest in 4He, 12C and 16O beams. The secondary radiation produced in the interaction of those beams with a patient could be potentially used for on-line monitoring of range uncertainties in order to fully exploit the advantages of those light ions resulting from increased Radio Biological Effectiveness, reduced multiple scattering and Oxygen Enhancement Ratio. The study and precise characterization of secondary radiation (beta+, prompt gamma, charged fragments) is the cornerstone of any R&D activity aiming for online monitoring development and purpose of the analysis presented here. Methods: We present the measurements of the secondary radiation generated by He, C and O beams impinging on a beam stopping PMMA target. The data has been collected at the Heidelberg Ionbeam Therapy center (HIT), where several millions of collisions were recorded at different energies, relevant for therapeutical applications. Results: The experimental setup, as well as the analysis strategies will be reviewed. The detected particle fluxes as a function of the primary beam energy and the emission angle with respect to the beam direction will be presented and compared to the results of other available measurements. In addition, the energy spectra and emission shapes of charged secondary particles will be shown and discussed in the context of the primary beam range monitoring technique that is being developed by the ARPG collaboration, within the INSIDE project funded by the Italian research ministry. The implications for dose monitoring applications will be discussed, in the context of the current (or planned) state-of- the-art detector solutions. Conclusion: The characterization of the radiation produced by 12C, 4He and 16O beams fully supports the feasibility of on-line range monitoring in the clinical practice of CPT by means of secondary particles detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Do Very Small POSS Nanoparticles Perturb s-PMMA Chain Conformations?

Small-angle neutron scattering (SANS) measurements of syndiotactic s-PMMA polymers mixed with weakly attractive 1.0 nm diameter polyhedral oligomeric silsesquioxane (POSS) nanoparticles (NPs) show no observable changes in the chain radius of gyration R g , regardless of the polymer molecular weights, the amount of residual solvent, or the POSS NP loading and dispersion (from 0 to 20 vol %). In retrospect, these results are not surprising since scaling arguments imply that chain size in the concentrated region of the phase diagram of a polymer solution is ideal and independent of the polymer volume fraction Φ, and only as the semidilute region is entered with decreasing concentration does the chain size for a good solvent begin to increase due to polymer excluded volume and then scales with concentration as Φ –1/8 . For typical polymer nanocomposites the NP concentrations are less than 50% v/v, so the polymers are still generally within the concentrated regions of their phase diagrams, where ideal chain conformations are observed for small molecule solvents. By combining the present results with previous results from the literature, we conclude that spherical NPs apparently have little effect on the conformations of polymer chains, especially in typical polymer nanocomposites that only incorporate moderate amounts of NPs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Full-field quantitative visualization of shock-driven pore collapse and failure modes in PMMA

The dynamic collapse of pores under shock loading is thought to be directly related to hot spot generation and material failure, which is critical to the performance of porous energetic and structural materials. However, the shock compression response of porous materials at the local, individual pore scale is not well understood. This study examines, quantitatively, the collapse phenomenon of a single spherical void in PMMA at shock stresses ranging from 0.4 to 1.0 GPa. Using a newly developed internal digital image correlation technique in conjunction with plate impact experiments, full-field quantitative deformation measurements are conducted in the material surrounding the collapsing pore for the first time. The experimental results reveal two failure mode transitions as shock stress is increased: (i) the first in situ evidence of shear localization via adiabatic shear banding and (ii) dynamic fracture initiation at the pore surface. Numerical simulations using thermo-viscoplastic dynamic finite element analysis provide insights into the formation of adiabatic shear bands (ASBs) and stresses at which failure mode transitions occur. Further numerical and theoretical modeling indicates the dynamic fracture to occur along the weakened material inside an adiabatic shear band. Finally, analysis of the evolution of pore asymmetry and models for ASB spacing elucidate the mechanisms for the shear band initiation sites, and elastostatic theory explains the experimentally observed ASB and fracture paths based on the directions of maximum shear.

42 ENGINEERING↗