Search NASA⌕ Search

SEARCH · Search NASA

Results for “PMTs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Characterization of the miniPlanacon XPM85112-S-R2D2 MCP-PMT with custom modified backend electronics

We report the results of the measurements of three pieces of the new Photonis miniPLANACON microchannel-plate photomultipliers (MCP-PMTs) intended for use in the demanding environment of the Large Hadron Collider (LHC) beamline as a part of the AFP Time-of-Flight detector. These photomultipliers were modified in cooperation with the manufacturer by using a custom backend and were subjected to numerous tests, with the focus on the rate capability and crosstalk behaviour. We determined that the two of them with a lower MCP resistance are able to operate without significant saturation at an anode current density of 1 μA/cm 2 . These two are, therefore, suitable for the intended use and are currently installed as part of the AFP detector packages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The scintillation light detection system of ICARUS-T600: Hardware implementation and early results

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is taking data with the Fermilab Booster Neutrino Beam-line (BNB) in the Short Baseline Neutrino (SBN) program to search for a possible LSND-like sterile neutrino signal. A light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs) deployed behind the TPC wire chambers, has been realized to detect vacuum ultraviolet (VUV) photons produced by ionizing particles in LAr. This system is fundamental for the detector operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the TPC is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the beam spill gates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronic set-up for the scintillation light detection system of ICARUS-SBN at Fermilab

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible sterile neutrino signal with the Booster Neutrino Beam (BNB). We discuss a light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs), which has been realized to detect vacuum ultraviolet (VUV) photons produced after the passage of ionizing particles in LAr. High performance electronics allows recording of the PMT signals and provides a fast discrimination for the exploitation of the scintillation light for trigger purposes. This system is fundamental for the TPC operation, contributing to the trigger system and for the 3D reconstruction of events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The data acquisition system of the LZ dark matter detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. Furthermore, the hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

K 2 CuX 3 (X = Cl, Br): All-Inorganic Lead-Free Blue Emitters with Near-Unity Photoluminescence Quantum Yield

Recently, copper(I) halides have been gaining increased attention as highly luminescent nontoxic alternatives to lead halide perovskites for optoelectronic applications. In this paper, we report preparation of blue emitting, lead free, all-inorganic halides K 2 CuX 3 (X = Cl, Br) through five synthetic methods including traditional solid-state and solution methods. The photoluminescence (PL) emission spectra of K 2 CuCl 3 and K 2 CuBr 3 exhibit narrow peaks centered at 392 and 388 nm with full widths at half-maximum (fwhm) values of ~54 nm. The visible bright blue emission is corroborated by the remarkably high photoluminescence quantum yield (PLQY) values up to ~97%. Furthermore, radioluminescence measurements on K 2 CuCl 3 yield a bright peak at 404 nm under irradiation with X-rays at 200 kVp and 20 mA, which is optimal for use with PMTs and Si photomultipliers, suggesting a strong potential of this family for radiation detection applications. Based on our combined experimental and computational investigations, the origin of the efficient luminescence in K 2 CuX 3 is attributed to the high stability self-trapped excitons (STE) formed in the one-dimensional anionic ∞ 1 [CuX 3 ] 2– chains. Advantageously, K 2 CuX 3 demonstrate improved air- and photostability compared to the previously reported copper(I) halides. The discovery of highly efficient and high stability light emitters based on earth-abundant copper(I) halides paves the way for their potential practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

Scintillation light detection in the long-drift ProtoDUNE-DP liquid argon TPC

ProtoDUNE-DP is a 6 × 6 × 6m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the Neutrino Platform at CERN in 2019-2020 as a prototype of the DUNE Far Detector. DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. The light signal in these detectors is crucial to provide precise timing capabilities. In ProtoDUNE-DP, scintillation light produced by cosmic muons in the LArTPC is collected by the photomultiplier tubes (PMTs) placed up to 7 m away from the point of interaction. The scintillation light production and propagation processes are analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The 3×1×1 m3 demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performance of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light detection and cosmic rejection in the ICARUS LArTPC at Fermilab

Abstract The ICARUS-T600 detector is a 760-ton Liquid Argon Time Projection Chamber (LArTPC) currently operating at Fermilab as the Far Detector in the Short Baseline Neutrino (SBN) program. The SBN program is composed of three LArTPCs with a central goal of testing the sterile neutrino hypothesis. After operating for 3-years in the Gran Sasso Underground Laboratory, the ICARUS detector was shipped to CERN where it was outfitted with 360 8” Photomultiplier Tubes (PMTs) for a new optical detection system. The PMT system detects fast scintillation light from charged particles interacting in the Liquid Argon, generating the trigger signal for the full detector and allows 3D reconstruction of events. Now operating at shallow depth, the detector is exposed to a high flux of cosmic rays that can fake neutrino interactions. To mitigate this effect a Cosmic Ray Tagger (CRT) and a 3-meter-thick concrete were installed. Precise timing information from both the PMT and CRT subsystems can help to identify whether an interaction originated from inside or outside of the ICARUS cryostat. This paper reviews a method for cosmogenic background reduction and timing calibration of the CRT and PMT light detection systems in ICARUS.

Instruments & Instrumentation↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Physics potential of the IceCube Upgrade for atmospheric neutrino oscillations

The IceCube Upgrade is an extension of the existing IceCube Neutrino Observatory and will be deployed in the 2025–2026 austral summer. It will significantly improve the sensitivity of the detector to atmospheric neutrino oscillations. The existing 86-string IceCube array contains a dense in-fill known as DeepCore which is optimized to measure neutrinos with energies down to a few GeV. The IceCube Upgrade will consist of seven new densely instrumented strings placed within the DeepCore volume to further enhance the performance in the GeV energy range. The additional strings will feature new optical modules, each containing multiple photomultiplier tubes (PMTs), in contrast to the existing modules that each contain a single PMT. This will more than triple the number of PMT channels with respect to the current IceCube configuration, allowing for improved detection efficiency and reconstruction performance at GeV energies. We describe necessary updates to simulation, event selection, and reconstruction to accommodate the higher data rates observed by the upgraded detector and the addition of multi-PMT modules. We determine the expected sensitivity of the IceCube Upgrade to the atmospheric neutrino oscillation parameters sin 2 ⁡𝜃 23 and Δ⁢𝑚$^{2}_{32}$, the appearance of tau neutrinos and the neutrino mass ordering. The IceCube Upgrade will provide neutrino oscillation measurements that are of similar precision to those from accelerator experiments, while providing complementarity by probing higher energies and longer baselines, and with different sources of systematic uncertainties.

artificial neural networks↗

PANDA-FES: Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science

Nuclear fusion is a potential source of carbon-free electricity with many concepts in development. The Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science (PANDA-FES) suite has been deployed since 2021 to measure neutron yield, energy, and spatiotemporal source location at two different Z-pinch fusion devices. This diagnostic can be used at a variety of facilities pursuing fusion in the magnetic, inertial, and magneto-inertial regimes. These different regimes have a wide range of time scales from less than 100 ns to a few μ s, neutron yields from 10 6 to 10 11 , and noise environments. Neutron yield is measured through activation of 79 Br and 89 Y with calibrated detectors. Temporal, spatial, and energy dependence of neutrons is measured with scintillators coupled to photomultiplier tubes (PMTs). Experimental setups and data analysis methods have been developed for these conditions. Finally, neutron yield, neutron energy anisotropy, and spatiotemporal evolution of the source have been measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗