Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ongoing Analysis of Rocket Based Combined Cycle Engines by the Applied Fluid Dynamics Analysis Group at Marshall Space Flight Center

This paper presents the status of analyses on three Rocket Based Combined Cycle configurations underway in the Applied Fluid Dynamics Analysis Group (TD64). TD64 is performing computational fluid dynamics analysis on a Penn State RBCC test rig, the proposed Draco axisymmetric RBCC engine and the Trailblazer engine. The intent of the analysis on the Penn State test rig is to benchmark the Finite Difference Navier Stokes code for ejector mode fluid dynamics. The Draco engine analysis is a trade study to determine the ejector mode performance as a function of three engine design variables. The Trailblazer analysis is to evaluate the nozzle performance in scramjet mode. Results to date of each analysis are presented.

Ruf, Joseph↗

Flowmeter evaluation for on-orbit operations

Various flowmetering concepts were flow tested to characterize the relative capabilities and limitations for on-orbit fluid-transfer operations. Performance results and basic operating principles of each flowmetering concept tested are summarized, and basic considerations required to select the best flowmeter(s) for fluid system application are discussed. Concepts tested were clamp-on ultrasonic, area averaging ultrasonic, offset ultrasonic, coriolis mass, vortex shedding, universal venturi tube, turbine, bearingless turbine, turbine/turbine differential-pressure hybrid, dragbody, and dragbody/turbine hybrid flowmeters. Fluid system flowmeter selection considerations discussed are flowmeter performance, fluid operating conditions, systems operating environments, flowmeter packaging, flowmeter maintenance, and flowmeter technology. No one flowmetering concept tested was shown to be best for all on-orbit fluid systems.

Baird, R. S.↗

Performance Model for Reversible Fluid Balloons

The Altitude Control Experiment (ALICE) is a balloon system that consists of a helium lifting balloon and a buoyancy-controlling freon R114 balloon. Condensation of freon gas in the cooler upper atmosphere and vaporization of liquid freon in the warmer lower atmosphere can be effectively used to adjust the net buoyant force so that the balloon system may float between desirable ranges of altitudes.This report summarizes efforts to produce an analytical model to predict the performance of this type of altitude control balloon in the earth's atmosphere. Various interactive parameters that are influential to the dynamics of the system were identified and treated. The analytical model developed herein correlated well with three ALICE day flight trajectories and one ALICE night flight trajectory in the earth's atmosphere. A similar approach can be applied to the design of a Venusian balloon system that could repeatedly travel to the lower, hot altitudes or surface of Venus for imaging or science experiments and then float higher in order to cool the electronics.

balloon↗

Inlet-Compressor Analysis Performed Using Coupled Computational Fluid Dynamics Codes

A thorough understanding of dynamic interactions between inlets and compressors is extremely important to the design and development of propulsion control systems, particularly for supersonic aircraft such as the High-Speed Civil Transport (HSCT). Computational fluid dynamics (CFD) codes are routinely used to analyze individual propulsion components. By coupling the appropriate CFD component codes, it is possible to investigate inlet-compressor interactions. The objectives of this work were to gain a better understanding of inlet-compressor interaction physics, formulate a more realistic compressor-face boundary condition for time-accurate CFD simulations of inlets, and to take a first step toward the CFD simulation of an entire engine by coupling multidimensional component codes. This work was conducted at the NASA Lewis Research Center by a team of civil servants and support service contractors as part of the High Performance Computing and Communications Program (HPCCP).

Cole, Gary L.↗

Thermal Performance of a Cryogenic Fluid Management Cubesat Mission

Development for an in-space demonstration of a CubeS at as a Cryogenic Fluid Management (CFM) test bed is currently underway. The favorable economics of CubeSats make them appealing for technology development activity. While their size limits testing to smaller scales, many of the regimes relevant to CFM can still be achieved. The first demo flight of this concept, CryoCube®-1, will focus on oxygen liquefaction and low-gravity level sensing using Reduced Gravity CryoTracker®. An extensive thermal modeling effort has been underway to both demonstrate concept feasibility and drive the prototype design. The satellite will utilize both a sun- and earth-shield to passively cool its experimental tank below 115 K. An on-board gas generator will create high pressure gaseous oxygen, which will be throttled into a bottle in the experimental node and condensed. The resulting liquid will be used to perform various experiments related to level sensing. Modeling efforts have focused on the spacecraft thermal performance and its effects on condensation in the experimental node. Parametric analyses for both optimal and suboptimal conditions have been considered and are presented herein.

Berg, J. J.↗

Performance of a plasma fluid code on the Intel parallel computers

One approach to improving the real-time efficiency of plasma turbulence calculations is to use a parallel algorithm. A parallel algorithm for plasma turbulence calculations was tested on the Intel iPSC/860 hypercube and the Touchtone Delta machine. Using the 128 processors of the Intel iPSC/860 hypercube, a factor of 5 improvement over a single-processor CRAY-2 is obtained. For the Touchtone Delta machine, the corresponding improvement factor is 16. For plasma edge turbulence calculations, an extrapolation of the present results to the Intel (sigma) machine gives an improvement factor close to 64 over the single-processor CRAY-2.

Lynch, V. E.↗

On the performance of finite journal bearings lubricated with micropolar fluids

A study of the performance parameters for a journal bearing of finite length lubricated with micropolar fluids is undertaken. Results indicate that a significantly higher load carrying capacity than the Newtonian fluids may result depending on the size of material characteristic length and the coupling number. It is also shown that although the frictional force associated with micropolar fluid is in general higher than that of a Newtonian fluid, the friction coefficient of micropolar fluids tends to be lower than that of the Newtonian.

Khonsari, M. M.↗

On the performance of finite journal bearings lubricated with micropolar fluids

A study of the performance parameters for a journal bearing of finite length lubricated with micropolar fluids is undertaken. Results indicate that a significantly higher load carrying capacity than the Newtonian fluids may result depending on the size of material characteristics length and the coupling number. It is also shown that although the frictional force associated with micropolar fluid is, in general, higher than that of a Newtonian fluid, the friction coefficient of micropolar fluids tends to be lower than that of the Newtonian.

Khonsari, M. M.↗

Testing of Liquid Metal Components for Nuclear Surface Power Systems

The capability to perform testing at both the module/component level and in near prototypic reactor configurations using a non-nuclear test methodology allowed for evaluation of two components critical to the development of a potential nuclear fission power system for the lunar surface. A pair of 1 kW Stirling power convertors, similar to the type that would be used in a reactor system to convert heat to electricity, were integrated into a reactor simulator system to determine their performance using pumped NaK as the hot side working fluid. The performance in the pumped-NaK system met or exceed the baseline performance measurements where the converters were electrically heated. At the maximum hot-side temperature of 550 C the maximum output power was 2375 watts. A specially-designed test apparatus was fabricated and used to quantify the performance of an annular linear induction pump that is similar to the type that could be used to circulate liquid metal through the core of a space reactor system. The errors on the measurements were generally much smaller than the magnitude of the measurements, permitting accurate performance evaluation over a wide range of operating conditions. The pump produced flow rates spanning roughly 0.16 to 5.7 l/s (2.5 to 90 GPM), and delta p levels from less than 1 kPa to 90 kPa (greater than 0.145 psi to roughly 13 psi). At the nominal FSP system operating temperature of 525 C the maximum efficiency was just over 4%.

Polzin, K. A.↗

Fluid infusion system

Performance testing carried out in the development of the prototype zero-g fluid infusion system is described and summarized. Engineering tests were performed in the course of development, both on the original breadboard device and on the prototype system. This testing was aimed at establishing baseline system performance parameters and facilitating improvements. Acceptance testing was then performed on the prototype system to verify functional performance. Acceptance testing included a demonstration of the fluid infusion system on a laboratory animal.

Source record↗

Choked flow of fluid nitrogen with emphasis on the thermodynamic critical region

A critical flow experiment was performed with fluid nitrogen in a converging-diverging nozzle at stagnation conditions from 87.5 to 234 K and pressures to 9.3 MN/sq m, with particular emphasis on the thermodynamic critical region. The nozzle throat conditions ranged from two-phase to near critical to gaseous. Proximity of the fluid in the nozzle to the critical point has a significant influence on the critical flow rate and pressure ratio curves. The flow rate exhibits an inflection and the pressure ratio shows a sharp peak when stagnation conditions are near the transposed critical point. The critical flow data are compared with equilibrium and nonequilibrium theories, and conditions are defined for which various methods of prediction remain valid.

Hendricks, R. C.↗

Working fluid selection for space-based two-phase heat transport systems

The working fluid for externally-mounted, space-based two-phase heat transport systems is considered. A sequence of screening criteria involving freezing and critical point temperatures and latent heat of vaporization and vapor density are applied to a data base of 860 fluids. The thermal performance of the 52 fluids which pass this preliminary screening are then ranked according to their impact on the weight of a reference system. Upon considering other nonthermal criteria (flammability, toxicity, and chemical stability) a final set of 10 preferred fluids is obtained. The effects of variations in system parameters is investigated for these 10 fluids by means of a factorial design.

Mclinden, Mark O.↗