Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polymer polymer interface”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Understanding Thermal Transport in Polymer –Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems.Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Thermal transport↗

Understanding Thermal Transport in Polymer - Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems. Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Matthew L. Fitzgerald↗

Direct Evidence of Graphene-Induced Molecular Reorientation in Polymer Films

For the first time, direct evidence of graphene-induced molecular reorientation in polymer films using polarization modulated infrared reflection absorption spectroscopy (PMIRRAS) are presented. By creating favorable electrostatic interactions, graphene-polymer interfaces can be controlled by varying polymer and solvent composition. After trans of unmodified graphene from copper onto a polymer substrate, polymer chain rearrangement relative to the orientation at the polymer-copper interface is observed using PM-IRRAS. Transfer success is characterized using both optical transmission measurements and Raman spectroscopy to quantify the transfer fidelity, i.e. graphene coverage fraction. Taken together, oxygencontaining poly(ethylene-co-vinyl acetate) shows more polymer chain rearrangement and better graphene coverage compared to oxygen-free polyethylene. Polymer composition seems to dominate graphene-polymer interactions while solvent choice has a smaller effect on transfer quality. These results are the first direct measurement of this effect and point towards the possibility of engineering graphene-polymer interactions for specific applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interfaces in polymer nanocomposites – An NMR study

Nuclear Magnetic Resonance (NMR) is applied for the investigation of polymer nanocomposites. Solid-state NMR is applied to study the modification steps to compatibilize layered double hydroxides with non-polar polymers. {sup 1}H relaxation NMR gives insight on the polymer dynamics over a wide range of correlation times. For the polymer chain dynamics the transverse relaxation time T{sub 2} is most suited. In this presentation we report on two applications of T{sub 2} measurements under external mechanical stress. In a low-field system relaxation NMR studies are performed in-situ under uniaxial stress. High-temperature experiments in a Couette cell permit the investigation of the polymer dynamics in the melt under shear flow.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of Critical Surface Parameters Driving Lectin-Mediated Capture of Bacteria from Solution

Lectin-functional interfaces are useful for isolation of bacteria from solution because they are low-cost and allow nondestructive, reversible capture. This study provides a systematic investigation of physical and chemical surface parameters that influence bacteria capture over lectin-functionalized polymer interfaces and then applies these findings to construct surfaces with significantly enhanced bacteria capture. The designer block copolymer poly(glycidyl methacrylate)-block-poly(vinyldimethyl azlactone) was used as a lectin attachment layer, and lectin coupling into the polymer film through azlactone–lectin coupling reactions was first characterized. Here, experimental parameters including polymer areal chain density, lectin molecular weight, and lectin coupling buffer were systematically varied to identify parameters driving highest azlactone conversions and corresponding lectin surface densities. To introduce physical nanostructures into the attachment layer, nanopillar arrays (NPAs) of varied heights (300 and 2100 nm) were then used to provide an underlying surface template for the functional polymer layer. Capture of Escherichia coli on lectin–polymer surfaces coated over both flat and NPA surfaces was then investigated. For flat polymer interfaces, bacteria were detected on the surface after incubation at a solution concentration of 10 3 cfu/mL, and a corresponding detection limit of 1.7 × 10 3 cfu/mL was quantified. This detection limit was 1 order of magnitude lower than control lectin surfaces functionalized with standard, carbodiimide coupling chemistry. NPA surfaces containing 300 nm tall pillars further improved the detection limit to 2.1 × 10 2 cfu/mL, but also reduced the viability of captured cells. Finally, to investigate the impact of cell surface parameters on capture, we used Agrobacterium tumefaciens cells genetically modified to allow manipulation of exopolysaccharide adhesin production levels. Statistical analysis of surface capture levels revealed that lectin surface density was the primary factor driving capture, as opposed to exopolysaccharide adhesin expression. These findings emphasize the critical importance of the synthetic interface and the development of surfaces that combine high lectin densities with tailored physical features to drive high levels of capture. These insights will aid in design of biofunctional interfaces with physicochemical surface properties favorable for capture and isolation of bacteria cells from solutions.

59 BASIC BIOLOGICAL SCIENCES↗

Application of the core shell model for strengthening polymer filament interfaces

While surface segregation has been intensively studied in thin films, relatively little has been investigated in filament geometries. In contrast to thin films, the filament surface forms a continuum, with interactions both at the free air and internal filament interface, which makes it difficult to achieve an equilibrium configuration. This asymmetry has become particularly apparent with the increasing use of additive manufacturing where entire structures are constructed via layered deposition of filamentous layers from a moving thermal nozzle. In addition, this process is highly non-equilibrated with poor thermal retention and is responsible for insufficient filament–filament interfacial fusion and internal pore formation along the printing direction. These features all contribute to poor mechanical and structural properties, which are exacerbated in semi-crystalline polymers, such as Polylactic Acid (PLA), where the melting point, T m , is much higher than the glass transition, T g . Even though system is liquid the molecules become ordered within the crystal structure and this ordering interferes with interdiffusion, which in turn prevents proper interfacial fusion. Capitalizing on the differential in surface tension, we show that addition of less than 1%, or trace amounts, of longer chain polymers, an oriented core shell structure, will be formed with a self-limiting thickness of three time the radius of gyration, R g , of the tracer chains. The lower T g of the tracers and their orientation makes them poised for interdiffusion when subsequent layers are deposited producing structures with significant improvement of the mechanical properties and internal structural integrity.

36 MATERIALS SCIENCE↗

Biomolecular complex viewed by dynamic nuclear polarization solid-state NMR spectroscopy

Solid-state nuclear magnetic resonance (ssNMR) is an indispensable tool for elucidating the structure and dynamics of insoluble and non-crystalline biomolecules. The recent advances in the sensitivity-enhancing technique magic-angle spinning dynamic nuclear polarization (MAS-DNP) have substantially expanded the territory of ssNMR investigations and enabled the detection of polymer interfaces in a cellular environment. This article highlights the emerging MAS-DNP approaches and their applications to the analysis of biomolecular composites and intact cells to determine the folding pathway and ligand binding of proteins, the structural polymorphism of low-populated biopolymers, as well as the physical interactions between carbohydrates, proteins, and lignin. Furthermore, these structural features provide an atomic-level understanding of many cellular processes, promoting the development of better biomaterials and inhibitors. It is anticipated that the capabilities of MAS-DNP in biomolecular and biomaterial research will be further enlarged by the rapid development of instrumentation and methodology.

36 MATERIALS SCIENCE↗

A new class of tunable hypersonic phononic crystals based on polymer-tethered colloids

The design and engineering of hybrid materials exhibiting tailored phononic band gaps are fundamentally relevant to innovative material technologies in areas ranging from acoustics to thermo-optic devices. Phononic hybridization gaps, originating from the anti-crossing between local resonant and propagating modes, have attracted particular interest because of their relative robustness to structural disorder and the associated benefit to ‘manufacturability’. Although hybridization gap materials are well known, their economic fabrication and efficient control of the gap frequency have remained elusive because of the limited property variability and expensive fabrication methodologies. Here we report a new strategy to realize hybridization gap materials by harnessing the ‘anisotropic elasticity’ across the particle–polymer interface in densely polymer-tethered colloidal particles. Theoretical and Brillouin scattering analysis confirm both the robustness to disorder and the tunability of the resulting hybridization gap and provide guidelines for the economic synthesis of new materials with deliberately controlled gap position and width frequencies.

36 MATERIALS SCIENCE↗

Probing Diffuse Polymer Brush Interfaces Using Resonant Soft X-ray Scattering

The success of a neutron or x-ray scattering experiment relies on sufficient signal from the system being studied. The intensity of scattered radiation depends on instrument resolution, the structure of the scattering elements, and the interaction between the incident radiation and the sample—so-called ‘scattering contrast’. The contrast depends on the square of the difference in the scattering length densities (SLDs) for each component, and each SLD depends on the atoms and radiation involved (eq. 1). For neutrons, the scattering lengths bi are specific to the type of nuclei involved. For conventional x-ray scattering, b i depends on the electron density and thus the atomic number Z.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Molecular Dynamics of ULTEM 9085 for 3D Manufacturing: Spectra, Thermodynamic Properties, and Shear Viscosity.

We present results of a molecular dynamic analysis of welding at the polymer-polymer interface. The analysis is performed for polyetherimide/ polycarbonate polymer blends. The work is motivated by the applications to 3D manufacturing in space. In the first part of the report, we discuss bulk and spectral characteristics of the amorphous polymer blends. The vibrational and infra-red spectra obtained using auto-correlation functions calculations in molecular dynamics are compared with the experimental spectra. The mechanical and thermal properties of the samples including heat capacity, bulk modulus, and thermal expansion coefficients are estimated and compared with experimental values. In the second part of the report, we discuss the result of molecular dynamical modeling of shear viscosity in a fully atomistic model of amorphous polymer blends with flat interface. The key result of the research is the demonstration of shear thinning behavior of the shear viscosity as a function of shear rate which is in good agreement with experimental data.

Luchinsky, Dmitry G.↗

Intrinsic thermal interfacial resistance measurement in bonded metal–polymer foils

Heat conduction through bonded metal–polymer interfaces often limits the overall heat transfer in electronic packaging, batteries, and heat recovery systems. To design the thermal circuit in such systems, it is essential to measure the thermal interfacial resistance (TIR) across ~1 µm to 100 µm junctions. Previously reported TIR of metal–polymer junctions utilize ASTM E1530-based two-block systems that measure the TIR by applying pressure across the interface through external heating and cooling blocks. Here, we report a novel modification of the ASTM-E1530 technique that employs integrated heaters and sensors to provide an intrinsic TIR measurement of an adhesively bonded metal–polymer junction. We design the measurement technique using finite element simulations to either passively suppress or actively compensate the lateral heat diffusion through the polymer, which can minimize the systematic error to ≲5%. Through proof-of-concept experiments, we report the TIR of metal–polymer interfaces made from DuPont’s Pyralux double-side copper-clad laminates, commonly used in flexible printed circuit boards. Our TIR measurement errors are <10%. We highlight additional sources of errors due to non-idealities in the experiment and discuss possible ways to overcome them. Our measurement technique is also applicable to interfaces that are electrically insulating such as adhesively joined metal–metal junctions and sputter-coated or welded metal–polymer junctions. Altogether, the technique is capable of measuring TIR ≳10 –5 m 2 KW –1 in bonded metal–polymer foils and can be tailored for in situ measurements in flexible electronics, circuit packaging, and other hybrid metal–polymer systems.

47 OTHER INSTRUMENTATION↗