Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precise timing electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Reduction and analysis of data from experiment CAI on the IMP-8 mission

The Caltech Electron/Isotope Spectrometer (EIS) on the Interplanetary Monitoring Platform 8 (IMP-8) has provided precise measurements of the energy spectra and time variations of low energy electrons (0.16 to 6 MeV), the isotopes of hydrogen and helium (approximately 2 to 40 MeV/nucleon), and the elements from lithium through oxygen (approximately 5 to 50 MeV/nucleon) in energetic particle fluxes of solar, galactic, interplanetary, and magnetospheric origin since 1973. The accomplishments that have resulted from EIS measurements during the period March 24, 1980 to December 31, 1984 are summarized.

Stone, E. C.↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Double-pulse speckle contrast correlations with near Fourier transform limited free-electron laser light using hard X-ray split-and-delay

Abstract The ability to deliver two coherent X-ray pulses with precise time-delays ranging from a few femtoseconds to nanoseconds enables critical capabilities of probing ultra-fast phenomena in condensed matter systems at X-ray free electron laser (FEL) sources. Recent progress made in the hard X-ray split-and-delay optics developments now brings a very promising prospect for resolving atomic-scale motions that were not accessible by previous time-resolved techniques. Here, we report on characterizing the spatial and temporal coherence properties of the hard X-ray FEL beam after propagating through split-and-delay optics. Speckle contrast analysis of small-angle scattering measurements from nanoparticles reveals well-preserved transverse coherence of the beam. Measuring intensity fluctuations from successive X-ray pulses also reveals that only single or double temporal modes remain in the transmitted beam, corresponding to nearly Fourier transform limited pulses.

42 ENGINEERING↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 μm and 32 ps resolutions from strips of 1 cm length and 500 μm pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

47 OTHER INSTRUMENTATION↗

Survey of AC-LGADs for future 4D trackers with a proton beam

We will present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility, and a study of the performance of AC-LGAD sensors as a function of their thickness. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. Long strip sensors with sparse readout offer better cost and performance for applications where channel count or electrical power density is a constraint. Thanks to the excellent signal to noise ratio in AC-LGADs, sparse readout can be exploited without significant degradation of spatial or time resolution, which is demonstrated in our studies. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. We will present our studies of the sensor geometry optimizatio n to maintain the desirable sensor performance characteristics with increasingly larger electrodes.

43 PARTICLE ACCELERATORS↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We will present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility, and a study of the performance of AC-LGAD sensors as a function of their thickness. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. Long strip sensors with sparse readout offer better cost and performance for applications where channel count or electrical power density is a constraint. Thanks to the excellent signal to noise ratio in AC-LGADs, sparse readout can be exploited without significant degradation of spatial or time resolution, which is demonstrated in our studies. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. We will present our studies of the sensor geometry optimization to maintain the desirable sensor performance characteristics with increasingly larger electrodes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ionospheric specification algorithms for precise GPS-based aircraft navigation

We present a technique for converting real-time total electron content (TEC) measurements into gridded vertical delay corrections at the GPS L***sub***1 frequency, which will be broadcast to users every 5 min via geosynchronous satellite. Users will convert these delays to slant corrections for their own particular lines of sight to GPS satellites. To preserve user safety, estimates of the error in the user delay corrections will also be broadcast.

Global↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 micron and 32 ps resolutions from strips of 1 cm length and 500 micron pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Toward monochromated sub-nanometer UEM and femtosecond UED

A preliminary design of a mega-electron-volt (MeV) monochromator with 10 –5 energy spread for ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) is presented. Such a narrow energy spread is advantageous in both the single shot mode, where the momentum resolution in diffraction is improved, and the accumulation mode, where shot-to-shot energy jitter is reduced. In the single-shot mode, we numerically optimized the monochromator efficiency up to 13% achieving 1.3 million electrons per pulse. In the accumulation mode, to mitigate the efficiency degradation caused by the shot-to-shot energy jitter, an optimized gun phase yields only a mild reduction of the single-shot efficiency, therefore the number of accumulated electrons nearly proportional to the repetition rate. Inspired by the recent work of Qi et al. (Phys Rev Lett 124:134803, 2020), a novel concept of applying reverse bending magnets to adjust the energy-dependent path length difference has been successfully realized in designing a MeV monochromator to achieve the minimum energy-dependent path length difference between cathode and sample. Thanks to the achromat design, the pulse length of the electron bunches and the energy-dependent timing jitter can be greatly reduced to the 10 fs level. The introduction of such a monochromator provides a major step forward, towards constructing a UEM with sub-nm resolution and a UED with ten-femtosecond temporal resolution. The one-to-one mapping between the electron beam parameter and the diffraction peak broadening enables a real-time nondestructive diagnosis of the beam energy spread and divergence. The tunable electric–magnetic monochromator allows the scanning of the electron beam energy with a 10 –5 precision, enabling online energy matching for the UEM, on-momentum flux maximizing for the UED and real-time energy measuring for energy-loss spectroscopy. A combination of the monochromator and a downstream chicane enables “two-color” double pulses with femtosecond duration and the tunable delay in the range of 10 to 160 fs, which can potentially provide an unprecedented femtosecond time resolution for time resolved UED.

36 MATERIALS SCIENCE↗

Software and Hardware Development for the Mu2e Trigger and Data Acquisition System

The Mu2e experiment at Fermilab will be 10,000 times more sensitive than previous experiments looking for muon-to-electron conversion. This precise and complex experimental apparatus will produce 200 million billion muons per year. The accelerator complex repurposes elements of the infrastructure that produced high energy proton and anti-protons beams for the Tevatron experiments to produce the high-intensity muon beams necessary for Mu2e and the Muon (g-2) experiments.

43 PARTICLE ACCELERATORS↗

Nanometer Resolution Structure‐Emission Correlation of Individual Quantum Emitters via Enhanced Cathodoluminescence in Twisted Hexagonal Boron Nitride

Understanding the atomic structure of quantum emitters, often originating from point defects or impuritie, is essential for designing and optimizing materials for quantum technologies such as quantum computing, communication, and sensing. Despite the availability of atomic-resolution scanning transmission electron microscopy and nanoscale cathodoluminescence microscopy, experimentally determining the atomic structure of individual emitters is challenging due to the conflicting needs for thick samples to generate strong cathodoluminescence signals and thin samples for structural analysis. To overcome this challenge, significantly enhanced cathodoluminescence at twisted interfaces is leveraged to achieve sub-nanometer localization precision for the first time in mapping individual quantum emitters in carbon-implanted hexagonal boron nitride. This unprecedent spatial sensitivity, together with correlative electron energy loss spectroscopy quantitative scanning transmission electron microscopy imaging, and first principles density functional theory calculations, enables the identification of the atomic structure of the 440 nm blue emitter in hexagonal boron nitride as a substituted vertical carbon dimer. Building on the atomic structure insights, nanoscale spatially precise creation of blue emitters is demonstrated by electron beam irradiation of carbon-coated hexagonal boron nitride. This advancement in correlating atomic structures with optical properties lays the foundation for a deeper understanding and precise engineering of quantum emitters, significantly advancing the development of cutting-edge quantum information technologies.

2D material↗

Toward fully automated UED operation using two-stage machine learning model

To demonstrate the feasibility of automating UED operation and diagnosing the machine performance in real time, a two-stage machine learning (ML) model based on self-consistent start-to-end simulations has been implemented. This model will not only provide the machine parameters with adequate precision, toward the full automation of the UED instrument, but also make real-time electron beam information available as single-shot nondestructive diagnostics. Furthermore, based on a deep understanding of the root connection between the electron beam properties and the features of Bragg-diffraction patterns, we have applied the hidden symmetry as model constraints, successfully improving the accuracy of energy spread prediction by a factor of five and making the beam divergence prediction two times faster. The capability enabled by the global optimization via ML provides us with better opportunities for discoveries using near-parallel, bright, and ultrafast electron beams for single-shot imaging. It also enables directly visualizing the dynamics of defects and nanostructured materials, which is impossible using present electron-beam technologies.

36 MATERIALS SCIENCE↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

Jefferson Lab High Precision Proton Radius Measurement Experiment: PRad

Proton is not a point-like particle; it has a finite size and an internal structure. The proton charge radius is usually measured through two different methods: using spectroscopy of hydrogen atoms, or through electron-proton (e - p) elastic scattering at low momentum transfer. In 2010, Phol et al [1] published a new measurement for proton charge radius obtained using the spectroscopy method from muonic hydrogen atoms. An ordinary hydrogen (H) atom is a bound state of an electron orbiting a proton. Likewise, a muonic hydrogen atom has a muon orbiting a proton. Since a muon has 200 times more mass than an electron, resulting in a much smaller orbiting radius, its orbit is much more sensitive to the proton charge distribution in space than the electron’s of an ordinary H-atom. Thus, the measurement from muonic hydrogen provides a 10 times more precise result than the previous methods. The radius from the muonic hydrogen measurement reported in [1] was significantly smaller than all the p

Bai, Xinzhan↗

Few-femtosecond time resolution in optically pumped hard X-ray scattering at a free-electron laser

Capturing chemical dynamics in real time is a central goal of ultrafast science, necessitating measurements fast enough to track atomic motion on few-femtosecond timescales with high precision. We present time-resolved hard X-ray scattering that meets these criteria by combining 7 fs full-width at half maximum (FWHM) near-infrared laser pulses with sub10 fs FWHM hard X-ray pulses from a free-electron laser. Using heavy water’s electronic response to strong-field ionization as a benchmark, we achieve a sub-8 fs FWHM instrument response function. These optical pump X-ray probe measurements enable direct observation of chemical dynamics with angstrom spatial and few-fs temporal resolution.

Weckwerth, Eleanor [Stanford University, CA (Unite↗