Search NASA⌕ Search

SEARCH · Search NASA

Results for “Procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Operating Procedure Extender For Novel Systems

Operating procedures that are used in nuclear power plants are primarily paper. These paper documents are functional for normal operations, but the process has remained relatively unchanged for thirty years. This neglects the digital technology advancements that have been made in that time. There are objectively more efficient ways to present a procedure to an operator using a digital interface. These digital interfaces require structured information to be able to function. This tool takes the procedure that has been written and converts it into the structured from required by the presentation system. This is accomplished through a reliable four phase compilation algorithm.

Lehmer, Jacob P↗

Dynamic Procedures Writer's Manual

This presentation provides the background information and introduction to a workshop with the goal to discuss a proposed standard for how to write dynamic procedures. The development of the proposed standard was conducted under the INL-led (Johanna Oxstrand) Work Digitalization Initiative. Mitch Burke (NextAxiom) and Steve McCord (Procedure Solution Management) are the authors of the proposed standard. They will lead the actual workshop.

47 OTHER INSTRUMENTATION↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory (BMS and RMS SOP)

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Determination of Total, Organic, and Inorganic Carbon and Total Nitrogen in Biological Cultures and Liquid Fraction Process Samples: Laboratory Analytical Procedure (LAP)

This Laboratory Analytical Procedure (LAP) describes the quantitative determination of total organic carbon, inorganic carbon in whole suspended biological samples and in the cell-free supernatant, by combustion and CO 2 detection with a non-dispersive infrared (NDIR) detector. This allows for distinct reporting of soluble and insoluble organic and inorganic carbon. In addition, this procedure covers the quantitative determination of soluble nitrogen in the cell-free supernatant.

09 BIOMASS FUELS↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2024 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2024 edition includes updates to the appendices to reflect the instrument changes from one year to another.

14 SOLAR ENERGY↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2025 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2025 edition includes updates to the appendices to describe the current instrumentation of the NREL-SRRL.

14 SOLAR ENERGY↗

An interlaboratory comparison of mid-infrared spectra acquisition: Instruments and procedures matter

Diffuse reflectance spectroscopy has been extensively employed to deliver timely and cost-effective predictions of a number of soil properties. However, although several soil spectral laboratories have been established worldwide, the distinct characteristics of instruments and operations still hamper further integration and interoperability across mid-infrared (MIR) soil spectral libraries. In this study, we conducted a large-scale ring trial experiment to understand the lab-to-lab variability of multiple MIR instruments. By developing a systematic evaluation of different mathematical treatments with modeling algorithms, including regular preprocessing and spectral standardization, we quantified and evaluated instruments' dissimilarity and how this impacts internal and shared model performance. We found that all instruments delivered good predictions when calibrated internally using the same instruments' characteristics and standard operating procedures by solely relying on regular spectral preprocessing that accounts for light scattering and multiplicative/additive effects, e.g., using standard normal variate (SNV). When performing model transfer from a large public library (the USDA NSSCKSSL MIR library) to secondary instruments, good performance was also achieved by regular preprocessing (e. g., SNV) if both instruments shared the same manufacturer. However, significant differences between the KSSL MIR library and contrasting ring trial instruments responses were evident and confirmed by a semi-unsupervised spectral clustering. For heavily contrasting setups, spectral standardization was necessary before transferring prediction models. Non-linear model types like Cubist and memory-based learning delivered more precise estimates because they seemed to be less sensitive to spectral variations than global partial least square regression. In summary, the results from this study can assist new laboratories in building spectroscopy capacity utilizing existing MIR spectral libraries and support the recent global efforts to make soil spectroscopy universally accessible with centralized or shared operating procedures.

58 GEOSCIENCES↗

Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests

Fracture injection/shut-in tests are commonly used to measure the state of stress. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering – the ‘tangent’ method and the ‘compliance’ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods – ‘first deviation from linearity’ and the method of Hayashi and Haimson. In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. In conclusion, the calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values.

58 GEOSCIENCES↗

Evaluation of SNOLAB background mitigation procedures through the use of an ICP-MS based dust monitoring methodology

Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of the naturally occurring radionuclides 40 K, 232 Th, 238 U, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models and assumed dust composition. Here, in this work, an ICP-MS based methodology was employed for a direct determination of fallout rates of radionuclides and stable isotopes of interest from dust particulate at the SNOLAB facility. Hosted in an active mine, the SNOLAB underground laboratory strives to maintain experimental areas at class 2000 cleanroom level. This work validates the mitigation procedures in place at SNOLAB and informs dust backgrounds during laboratory activities. Fallout rates of major constituents of the local rock were measured two to three orders of magnitude lower in the clean experimental areas compared to non-clean transition areas from the mine to the laboratory. An increase of approximately two orders of magnitude in the fallout rate of stable Pb isotopes was determined in an experimental area during activities involving handling of Pb bricks. Increased 40 K, 232 Th, and 238 U fallout rates were measured in clean experimental areas during activities generating particulate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ATLAS ITk strip sensor quality control procedures and testing site qualification

Abstract The high-luminosity upgrade of the Large Hadron Collider, scheduled to become operational in 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker. Radiation hard n + -in-p micro-strip silicon sensors were developed by the ATLAS Inner Tracker strip collaboration and are produced by Hamamatsu Photonics K.K. Production of the total amount of 22000 strip sensors has started in 2020 and will continue until 2025. The ATLAS strip sensor collaboration has the responsibility to monitor the quality of the fabricated devices by performing detailed measurements of individual sensor characteristics and by comparing the obtained results with the tests done by the manufacturer. Dedicated Quality Control procedures were developed to check whether the delivered large-format sensors adhere to the ATLAS specifications. The institutes performing the Quality Control testing of the pre-production and production ATLAS ITk strip sensors had to initially be qualified for multiple high-throughput tests by successfully completing the Site Qualification process. The Quality Control procedures and the qualification process are described in this paper.

Instruments & Instrumentation↗

A Weakly Supervised Machine Learning Procedure for Magnet Quench Diagnostics

Voltage taps remain the standard and reliable diagnostic tool for detecting quenches in superconducting magnets. However, they identify a quench only at the time of voltage rise and do not provide information on earlier physical precursors. In this work, we investigate whether acoustic emission data can reveal precursor activity that occurs before conventional voltage detection using machine learning techniques. We introduce an event selection method and a weakly supervised machine learning procedure to learn data-driven criteria for identifying potential acoustic precursors to quenches. Two Convolutional Neural Network (CNN) architectures are trained: one on acoustic sensor events from our selection procedure and one on the Fast Fourier Transforms (FFTs) of these events. Both networks are trained iteratively using confidence-weighted loss functions to associate certain subsets of training data with a precursor label. We evaluate the performance of these models by examining the time distribution of events classified as potential precursors relative to the quench onset. Results indicate that the proposed approach can possibly distinguish acoustic emission events occurring closer to the quench from earlier acoustic activity during ramping, suggesting the potential for flagging quench precursors in acoustic data.

Khan, Maira [Fermilab] (ORCID:0009000891602387)↗

A Fast Temporal Decomposition Procedure for Long-Horizon Nonlinear Dynamic Programming

We propose a fast temporal decomposition procedure for solving long-horizon nonlinear dynamic programs. The core of the procedure is sequential quadratic programming (SQP) that utilizes a differentiable exact augmented Lagrangian as the merit function. Within each SQP iteration, we approximately solve the Newton system using an overlapping temporal decomposition strategy. We show that the approximate search direction is still a descent direction of the augmented Lagrangian provided the overlap size and penalty parameters are suitably chosen, which allows us to establish the global convergence. Moreover, we show that a unit step size is accepted locally for the approximate search direction and further establish a uniform, local linear convergence over stages. This local convergence rate matches the rate of the recent Schwarz scheme (Na et al. 2022). However, the Schwarz scheme has to solve nonlinear subproblems to optimality in each iteration, whereas we only perform a single Newton step instead. Numerical experiments validate our theories and demonstrate the superiority of our method.

97 MATHEMATICS AND COMPUTING↗

Rejection of malathion by nanofiltration and reverse osmosis membranes exposed to foulant and two clean-in-place procedures

This research tested the treatment efficacy of an Energy Savings Nanofiltration 1 Low Fouling (ESNA 1-LF) nanofiltration (NF) and an Energy Saving Polyamide 2 (ESPA2) reverse osmosis (RO) membrane for removing malathion from water. Both membranes are of composite polyamide construction. The study included measuring malathion rejection using both pristine membranes and membranes exposed to a simulated secondary wastewater effluent foulant before and after two types of clean-in-place procedures. Across all conditions studied, malathion rejection ranged from 84 to 95% for the ESNA1-LF NF membrane and 77 to 94% for the ESPA2 RO membrane. Contact angle measurements were also collected for each membrane exposure condition. While the contact angle measurements indicated changes to the hydrophobicity of the selective layer of the membranes, they did not correlate to changes in the performance of malathion rejection. As expected, it was observed that malathion rejection improved with the introduction of foulant. Also, the clean-in-place procedures helped restore flux while maintaining malathion rejection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quality Procedures for TCR Metal Core Structure Advanced Manufacturing Processes

The Transformational Challenge Reactor (TCR) Manufacturing WBS# 3.02.04.02 organization is responsible for the advanced manufacturing process, research, development, and implementation that supports the TCR program under the TCR Additive Manufacturing (AM) Thrust. Advanced manufacturing at Oak Ridge National Laboratory (ORNL) includes the development and capabilities to use modern advanced manufacturing techniques, such as AM (e.g., 3D printing) and other novel methods, to rapidly design, develop, produce, finish, and characterize parts, samples, and components to support the nuclear and other high-quality standards industries. Deliverable # M2TC-20OR04020110 involved the development of TCR quality procedures for the TCR metal core structure by using the advanced manufacturing processes being developed at ORNL’s Manufacturing Demonstration Facility (MDF) and other ORNL locations. This report discusses the details of these procedures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rapid Quality Assessment in Additive Manufacturing: New Procedure Accelerates Build Quality Assessment. White paper

Accelerated growth of the additive manufacturing (AM) industry in recent years is accompanied by a rising need for methods to quickly assess quality at-scale. Current practices for quality inspection include nondestructive test methods and destructive testing of witness coupons, which are artifacts built alongside the actual part. However, these methods can be costly and time-consuming. Recognizing this need, the Additive Manufacturing Center of Excellence (AM CoE) initiated a project led by its partner, Auburn University, to develop rapid testing procedure using asbuilt samples tested in torsion to quantitatively assess build quality. The presented work developed a rapid testing procedure using as-built samples tested in torsion to quantify small variances for assessing build quality.

42 ENGINEERING↗

Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in Bio-Oils: Laboratory Analytical Procedure (LAP)

The determination of total carbon, hydrogen, and nitrogen in bio-oils is important as these values can be used to track the carbon balance of production processes as well as calculate total oxygen content by difference. Oxygen content of bio-oils is a key metric for production and upgrading strategies as these are typically aimed at reducing oxygen. Oxygenates in bio-oils contribute to poor hydrocarbon miscibility, high acidity, high viscosity, and poor stability. Upgrading of bio-oils via deoxygenation produces hydrocarbons which can be used to generate feedstocks for renewable fuels and chemicals. In this Laboratory Analytical Procedure (LAP), combustion-based ultimate analysis is used to determine the weight percent (wt%) of C, H, and N in bio-oils and upgraded products. Ultimate analysis uses high temperatures and a pure oxygen environment to completely combust organic samples to carbon dioxide (CO 2 ), water (H 2 O), and nitrogen oxides (NO x ). In this procedure the amount of C and H in the sample are quantified by measuring resultant CO 2 and H 2 O with Fourier-transform infrared spectroscopy (FTIR). For N, NO x is reduced to nitrogen (N 2 ) which is measured with a thermal conductivity detector (TCD), providing total N content.

09 BIOMASS FUELS↗