Search NASASearch

SEARCH · Search NASA

Results for “RC NETWORK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Power converter

A dc-to-dc converter employs four transistor switches in a bridge to chop dc power from a source, and a voltage multiplying diode rectifying ladder network to rectify and filter the chopped dc power for delivery to a load. The bridge switches are cross coupled in order for diagonally opposite pairs to turn on and off together using RC networks for the cross coupling to achieve the mode of operation of a free running multivibrator, and the diode rectifying ladder is configured to operate in a push-pull mode driven from opposite sides of the multivibrator outputs of the ridge switches. The four transistor switches provide a square-wave output voltage which as a peak-to-peak amplitude that is twice the input dc voltage, and is thus useful as a dc-to-ac inverter.

Black, J. M.

Extraction of Qualitative Features from Sensor Data Using Windowed Fourier Transform

In this paper, we use Matlab to model the health monitoring of a system through the information gathered from sensors. This implies assessment of the condition of the system components. Once a normal mode of operation is established any deviation from the normal behavior indicates a change. This change may be due to a malfunction of an element, a qualitative change, or a change due to a problem with another element in the network. For example, if one sensor indicates that the temperature in the tank has experienced a step change then a pressure sensor associated with the process in the tank should also experience a step change. The step up and step down as well as sensor disturbances are assumed to be exponential. An RC network is used to model the main process, which is step-up (charging), drift, and step-down (discharging). The sensor disturbances and spike are added while the system is in drift. The system is allowed to run for a period equal to three time constant of the main process before changes occur. Then each point of the signal is selected with a trailing data collected previously. Two trailing lengths of data are selected, one equal to two time constants of the main process and the other equal to two time constants of the sensor disturbance. Next, the DC is removed from each set of data and then the data are passed through a window followed by calculation of spectra for each set. In order to extract features the signal power, peak, and spectrum are plotted vs time. The results indicate distinct shapes corresponding to each process. The study is also carried out for a number of Gaussian distributed noisy cases.

Amini, Abolfazl M.

Tunable bandpass filter with variable selectivity

Basic active RC networks constructed from stages that realize second-order transfer functions using two integrators offer excellent stability. Modifications of the basic network produce a highly stable bandpass filter having separate controls that independently adjust center frequency, Q, and center frequency gain.

Kerwin, W. J.

Qualitative Features Extraction from Sensor Data using Short-time Fourier Transform

The information gathered from sensors is used to determine the health of a sensor. Once a normal mode of operation is established any deviation from the normal behavior indicates a change. This change may be due to a malfunction of the sensor(s) or the system (or process). The step-up and step-down features, as well as sensor disturbances are assumed to be exponential. An RC network is used to model the main process, which is defined by a step-up (charging), drift, and step-down (discharging). The sensor disturbances and spike are added while the system is in drift. The system runs for a period of at least three time-constants of the main process every time a process feature occurs (e.g. step change). The Short-Time Fourier Transform of the Signal is taken using the Hamming window. Three window widths are used. The DC value is removed from the windowed data prior to taking the FFT. The resulting three dimensional spectral plots provide good time frequency resolution. The results indicate distinct shapes corresponding to each process.

Amini, Abolfazl M.

Inductorless filters

Gyrator-capacitor network used in production of inductorless filters with RC-ACTIVE networks

NETWORK SYNTHESIS

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]

Solid-state switch increases switching speed

Solid state switch for commutating capacitors in an RC commutated network increases switching speed and extends the filtering or commutating frequency spectrum well into the kilocycle region. The switch is equivalent to the standard double- pole double-throw /DPDT/ relay and is driven from digital micrologic circuits.

Mc~gowan, G. F.