Search NASA⌕ Search

SEARCH · Search NASA

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

Barkas effect in strongly magnetized plasmas

Strongly magnetized plasmas, which are characterized by the particle gyrofrequency exceeding the plasma frequency, exhibit novel transport properties. For example, recent work showed that the friction force on a test charge moving through a strongly magnetized plasma not only consists of the typical stopping power component but also includes components perpendicular to the test charge's velocity. However, these studies only considered test charges that have the same sign as the charge of the plasma particles. Here, we extend these calculations to the case of charges with opposite signs (such as an ion interacting with strongly magnetized electrons). This is done with both a novel generalized Boltzmann kinetic theory and molecular dynamics simulations. It is found that the friction force changes dramatically depending on the sign of the interacting charges. Likewise, the stopping power component for oppositely charged particles decreases in magnitude compared with like-charged particles, and the perpendicular components increase in magnitude. Moreover, the difference between the two cases increases as the gyrofrequency becomes larger compared with the plasma frequency. Finally, the electrical resistivity is calculated from the friction force, where it is found that strong magnetization in conjunction with oppositely charged interactions significantly decreases the parallel resistivity and increases the perpendicular resistivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of a minority relativistic electron tail interacting with a thermal plasma containing high-atomic-number impurities

A minority relativistic electron component can arise in both laboratory and naturally-occurring plasmas. In the presence of high-atomic-number ion species, the ion charge state distribution at low bulk electron temperature can be dominated by relativistic electrons, even though their density is orders of magnitude lower. This is due to the relativistic enhancement of the collisional excitation and ionization cross sections. The resulting charge state effect can dramatically impact the radiative power loss rate and the related Bethe stopping power of relativistic electrons in a dilute plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First-In-Human Validation of CT-Based Proton Range Prediction Using Prompt Gamma Imaging in Prostate Cancer Treatments

Uncertainty in computed tomography (CT)-based range prediction substantially impairs the accuracy of proton therapy. Direct determination of the stopping-power ratio (SPR) from dual-energy CT (DECT) has been proposed (DirectSPR), and initial validation studies in phantoms and biological tissues have proven a high accuracy. However, a thorough validation of range prediction in patients has not yet been achieved by any means. Here, we present the first systematic validation of CT-based proton range prediction in patients using prompt gamma imaging (PGI).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

Effects of Coulomb coupling on friction in strongly magnetized plasmas

The friction force on a test particle traveling through a plasma that is both strongly coupled and strongly magnetized is studied using molecular dynamics simulations. In addition to the usual stopping power component aligned antiparallel to the velocity, a transverse component that is perpendicular to both the velocity and Lorentz force is observed. This component, which was recently discovered in weakly coupled plasmas, is found to increase in both absolute and relative magnitude in the strongly coupled regime. Strong coupling is also observed to induce a third component of the friction force in the direction of the Lorentz force. These first-principles simulations reveal novel physics associated with collisions in strongly coupled, strongly magnetized, plasmas that are not predicted by existing kinetic theories. The effect is expected to influence macroscopic transport in a number of laboratory experiments and astrophysical plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review of the first charged-particle transport coefficient comparison workshop

We present the results of the first Charged-Particle Transport Coefficient Code Comparison Workshop, which was held in Albuquerque, NM October 4–6, 2016. In this first workshop, scientists from eight institutions and four countries gathered to compare calculations of transport coefficients including thermal and electrical conduction, electron–ion coupling, inter-ion diffusion, ion viscosity, and charged particle stopping powers. In this paper, we give general background on Coulomb coupling and computational expense, review where some transport coefficients appear in hydrodynamic equations, and present the submitted data. Large variations are found when either the relevant Coulomb coupling parameter is large or computational expense causes difficulties. Understanding the general accuracy and uncertainty associated with such transport coefficients is important for quantifying errors in hydrodynamic simulations of inertial confinement fusion and high-energy density experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of the second charged-particle transport coefficient code comparison workshop

We report the results of the second charged-particle transport coefficient code comparison workshop, which was held in Livermore, California on 24–27 July 2023. This workshop gathered theoretical, computational, and experimental scientists to assess the state of computational and experimental techniques for understanding charged-particle transport coefficients relevant to high-energy-density plasma science. Data for electronic and ionic transport coefficients, namely, the direct current electrical conductivity, electron thermal conductivity, ion shear viscosity, and ion thermal conductivity were computed and compared for multiple plasma conditions. Additional comparisons were carried out for electron–ion properties such as the electron–ion equilibration time and alpha particle stopping power. Overall, 39 participants submitted calculated results from 18 independent approaches, spanning methods from parameterized semi-empirical models to time-dependent density functional theory. In the cases studied here, we find significant differences—several orders of magnitude—between approaches, particularly at lower temperatures, and smaller differences—roughly a factor of five—among first-principles models. We investigate the origins of these differences through comparisons of underlying predictions of ionic and electronic structure. The results of this workshop help to identify plasma conditions where computationally inexpensive approaches are accurate, where computationally expensive models are required, and where experimental measurements will have high impact.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalies in the Electronic Stopping of Slow Antiprotons in LiF

We present first-principles theoretical calculations for the electronic stopping power (SP) of both protons and antiprotons in LiF. Our results show the presence of the Barkas effect: a higher stopping for positively charged particles than their negatively charged antiparticles. In contrast, a previous study has predicted an anti-Barkas effect (higher stopping for negative charges) at low velocity [Qi, Bruneval and Maliyov, Phys. Rev. Lett. 128, 043401 (2022)]. Here, we explain this discrepancy by showing that this anti-Barkas effect appears for highly symmetric trajectories and disappears when considering trajectories that better reproduce the experimental setup. Our low-velocity results show that the SP of both protons and antiproton vanish for velocities under 0.1 a.u.

3-dimensional systems↗

Directional dependency of electronic stopping in nickel, projectile’s excited charge state and momentum transfer

Abstract We studied the directional dependency of electronic stopping power of swift light ions in nickel using real-time time-dependent density functional theory. We report a variation of electronic stopping for moving ions as the projectile probes different electronic densities of the host material. These results show that while the predicted magnitude stays in reasonable agreement with experiment, for $$v > 2$$ v > 2 . a.u. simulating only low index crystallographic directions is not enough to sample the experimental average values. The ab initio simulations give us access to microscopic quantities, such as non-adiabatic forces, momentum transfer and transient excited state charges of the projectile and host ions, which are not available through other methods. We report these quantities for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic stopping in molecular dynamics simulations of cascades in 3C–SiC

Here, we investigate the effect of the electronic stopping power on defect production due to ion irradiation of cubic silicon carbide using molecular dynamics simulations. We simulate 20 keV and 30 keV Si and C ions, with and without the electronic energy loss. The results show that the electronic stopping effects are more profound in the case of C irradiation, where the ratio of the electronic energy loss S e to the nuclear energy loss S n is much larger compared to the ratio for Si ions. These findings indicate that this ratio plays a role in the effect of the electronic stopping on ion irradiation.

36 MATERIALS SCIENCE↗

Time-dependent density-functional-theory calculations of the nonlocal electron stopping range for inertial confinement fusion applications

Nonlocal electron transport is important for understanding laser-target coupling for laser-direct-drive (LDD) inertial confinement fusion (ICF) simulations. Current models for the nonlocal electron mean free path in radiation-hydrodynamic codes are based on plasma-physics models developed decades ago; improvements are needed to accurately predict the electron conduction in LDD simulations of ICF target implosions. Here we utilized time-dependent density functional theory (TD-DFT) to calculate the electron stopping power (SP) in the so-called conduction-zone plasmas of polystyrene in a wide range of densities and temperatures relevant to LDD. Compared with the modified Lee-More model, the TD-DFT calculations indicated a lower SP and a higher stopping range for nonlocal electrons. We fit these electron SP calculations to obtain a global analytical model for the electron stopping range as a function of plasma conditions and the nonlocal electron kinetic energy. This model was implemented in the one-dimensional radiation-hydrodynamic code LILAC to perform simulations of LDD ICF implosions, which are further compared with simulations by the standard modified Lee-More model. In conclusion, results from these integrated simulations are discussed in terms of the implications of this TD-DFT-based mean-free-path model to ICF simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Devices for Thermal Conductivity Measurements of Electroplated Bi for X-ray TES Absorbers

Electroplated bismuth (Bi) is commonly used in transition-edge sensors (TESs) for X-rays because of its high stopping power and low heat capacity (Collan in Phys Rev B 1:2888, 1970, Yan in Appl Phys Lett 111:192602, 2017). Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically gold (Au), making it challenging to extrapolate its thermoelectric properties. In this work, we present four-wire resistance measurement structures that allow us to measure resistance as a function of temperature of electroplated Bi independently of Au. The results show that the thermal conductivity of the Bi at 3 K is high enough to ensure the correct thermalization of X-ray photons when used as an absorber for TESs.

Bismuth↗

Mechanisms of ion irradiation induced ordering in amorphous TiO 2 nanotubes: Effects of ion mass and energy

Here, amorphous TiO 2 nanotubes were irradiated in-situ in a transmission electron microscope (TEM) with Kr + ions at energies of 46 keV, 150 keV, and 1 MeV and with 46 keV Xe + ions, to investigate the structural and morphological evolution of the nanotubes under irradiation. At all irradiation conditions, amorphous TiO 2 nanotubes exhibited significant morphological instability, and tended to undergo volumetric swelling with increasing ion counts, often until collapse of the original nanotube structure. Molecular dynamics (MD) simulations confirmed that irradiation-induced defects can explain the observed swelling. Structurally, nanotubes remain amorphous following all Kr + irradiation conditions, but irradiation with 46 keV Xe + leads to the formation of anatase nanocrystallites. Importantly, through systematically varying ion energy and ion species, we try to elucidate the influence of nuclear and electronic stopping power on ion irradiation induced changes. By contextualizing these results within the existing literature, we propose that the observed changes in TiO 2 nanotube morphology and structure could be due to a competition between two mechanisms: (1) disorder-induced swelling and (2) irradiation-induced amorphous-to-crystalline transformation.

36 MATERIALS SCIENCE↗

In-situ ion irradiation induced nanograin growth in a spent UO 2 fuel

This study investigates the irradiation-driven evolution of nanograins in the early-stage restructured rim region of medium burnup spent uranium dioxide (UO 2 ) fuel. Transmission electron microscopy (TEM) lamellas prepared from Belgium Reactor 3 (BR-3) fuel were subjected to in-situ 300 keV Xe ion irradiations under varying doses, fluxes, and temperatures to evaluate their effect on the evolution of the nanograins. Our results reveal that the nanograins grow during ion irradiation. Additionally, the growth is most pronounced at elevated temperatures (300 °C), moderate at room temperature, and negligible at cryogenic temperature (−223 °C). This behavior indicates that thermal activation, alongside irradiation effects, is essential to overcome grain boundary pinning by fission gas bubbles, metallic precipitates, and porosity. Furthermore, while nanograins (<200 nm) consistently coarsened under irradiation, larger grains did not undergo further restructuring, which can be attributed to the strong defect annihilation at TEM lamella surfaces combined with the limited electronic stopping power of low energy Xe ions used in this work. These findings highlight the roles of thermal spike effects, defect mobility, and impurity pinning in governing grain evolution in the rim region of spent UO 2 fuel during ion irradiation, providing key insights for predictive models of restructuring and performance of the high burnup nuclear fuel.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compound pulse characteristics of a heterogeneous composite scintillator in a gamma-ray field

An important aspect of radiation detection in scintillators is the time dependence of emitted fluorescence, which results in characteristic measured pulse shape. In some materials, a relatively strong dependence of the scintillation pulse shape on stopping power exists, which can provide reliable identification of the incident particle. An alternative method to realize particle identification is by combining materials with different fluorescence lifetimes into heterogeneous structures. Such composite scintillators derive their properties from both the constituent material characteristics and the geometry of the composite structure. In composite scintillators with a high degree of heterogeneous loading, a superposition of fluorescence contributions originating in multiple materials, which is observed as single waveform with an intermediate pulse shape, may affect its ability to reject rays. We measure the time dependence of light output from a scintillator composed of 6 Li-containing glass shards and scintillating polyvinyl toluene and identify events that exhibit such compound behavior when exposed to rays and fast neutrons. We develop a modeling and simulation framework that reproduces the pulse shapes in heterogeneous scintillators and use it study the effect that the weight percentage of 6 Li glass has on rejection. The modeling framework is applied to the experimentally studied scintillator, finding a good agreement. Here, the developed modeling and simulation approach will help optimize the design of heterogeneous scintillators to meet the desired trade-o between neutron capture efficiency and -ray rejection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗