Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

EPCAPE-PT-LANL Measurements: Wideband Integrated Bioaerosol Sensor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Wideband Integrated Bioaerosol Sensor (Droplet Measurements Technology) Data Notes: The WIBS is an online single-particle measurement that detects FBAPs (within a size range of 0.5 - 30 microns in diameter) based on the excitation and emission wavelengths of the individual particles. Using two xenon lamps, the WIBS excites FBAPs at 280 nm and 370 nm. Their emission is detected across two wavebands of 310-400 nm and 420-650 nm. We classified the FBAPs into seven different categories (A, B, C, AB, BC, AC, and ABC) using the classification scheme in Perring et. al. (2015) [1]. Averaged number concentration of FBAPs (total and by category) and particles that non-fluorescent bioaerosols particles (NFBAPs). In separate files, we also present one-minute-averaged size distributions and the asymmetry factor (AF, a surrogate for shape) of all FBAPs and NFBAPs. The logarithmic bin width of the size bins are the same as the average bin width of the AOS's optical particle counter (OPC, Grimm) for the range of sizes in which they overlap (26 bins from 0.5 - 30 microns). AF of the particles ranges from 0-100 and is divided into five bins with a linear spacing at increments of 20. The smallest AF bin represents more spherical particles while the largest bin represents more rod-shaped particles. [1] Perring, A. E., et al. (2015), Airborne observations of regional variation in fluorescent aerosol across the United States, J. Geophys. Res. Atmos., 120, 1153–1170, doi:10.1002/2014JD022495. Abstract and description of the campaign can be found here : https://www.arm.gov/research/campaigns/amf2023epcape-pt-lanl. Files data_10min_WIBS_AFDist.csv Header: - FBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of FBAPs detected during the measurement. - NFBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of non-fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of NFBAPs detected during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. AF Bins: • Bin 1: 0 – 20 [unitless] • Bin 2: 21 – 40 [unitless] • Bin 3: 41 – 60 [unitless] • Bin 4: 61 – 80 [unitless] • Bin 5: 81 – 100 [unitless] Files data_10min_WIBS_Conc.csv Header: - NumberConcentrationA[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel A, measured in particles per cubic centimeter. - NumberConcentrationB[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel B, measured in particles per cubic centimeter. - NumberConcentrationC[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel C, measured in particles per cubic centimeter. - NumberConcentrationAB[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and B, measured in particles per cubic centimeter. - NumberConcentrationBC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels B and C, measured in particles per cubic centimeter. - NumberConcentrationAC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and C, measured in particles per cubic centimeter. - NumberConcentrationABC[/cm3]: Combined number concentration of bioaerosol particles detected by all three fluorescence channels A, B, and C, measured in particles per cubic centimeter. - NumberConcentrationNFBAP[/cm3]: Number concentration of non-fluorescent bioaerosol particles, measured in particles per cubic centimeter. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Files data_10min_WIBS_SizeDist.csv Header: - FBAP_SizeDist[/cm3]_Bin_1 to FBAP_SizeDist[/cm3]_Bin_26: Number concentrations of FBAP in each of 26 size bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle sizes, capturing the size distribution of FBAPs detected during the measurement. - NFBAP_SizeDist[/cm3]_Bin_1 to NFBAP_SizeDist[/cm3]_Bin_26: Number concentrations of NFBAP in each of 26 size bins, measured in particles per cubic centimeter. Similar to FBAP, each bin covers a specific range of particle sizes, detailing the size distribution of NFBAPs detected. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Size Bins: • Bin 1: 0.48 to 0.57 μm • Bin 2: 0.57 to 0.67 μm • Bin 3: 0.67 to 0.79 μm • Bin 4: 0.79 to 0.93 μm • Bin 5: 0.93 to 1.1 μm • Bin 6: 1.1 to 1.29 μm • Bin 7: 1.29 to 1.52 μm • Bin 8: 1.52 to 1.8 μm • Bin 9: 1.8 to 2.11 μm • Bin 10: 2.11 to 2.5 μm • Bin 11: 2.5 to 2.94 μm • Bin 12: 2.94 to 3.46 μm • Bin 13: 3.46 to 4.08 μm • Bin 14: 4.08 to 4.81 μm • Bin 15: 4.81 to 5.67 μm • Bin 16: 5.67 to 6.68 μm • Bin 17: 6.68 to 7.88 μm • Bin 18: 7.88 to 9.29 μm • Bin 19: 9.29 to 10.96 μm • Bin 20: 10.96 to 12.92 μm • Bin 21: 12.92 to 15.23 μm • Bin 22: 15.23 to 17.96 μm • Bin 23: 17.96 to 21.17 μm • Bin 24: 21.17 to 24.96 μm • Bin 25: 24.96 to 29.43 μm • Bin 26: 29.43 to 34.70 μm

54 ENVIRONMENTAL SCIENCES↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Hydrogen Sensor and Separator for Parabolic Trough Expansion Tanks

The National Renewable Energy Laboratory (NREL) and Acciona Energy USA Global are developing and implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). As part of this effort, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. During previous work, we demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 1.33 mbar down to 0.003 mbar. In this paper, we report our most recent work, in which we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Sensor data from the integrated module also provide an estimate of the rate at which hydrogen is being extracted from the headspace gas. We designed and fabricated a laboratory-scale integrated module and determined its performance in our laboratory at NREL. Testing showed that the module performed as expected in both sensing and separating modes. The accuracy of the sensing function was +/-10%. The hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. The integrated module can be installed close to the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. We are currently installing a test-scale process at the Nevada Solar One (NSO) power plant to demonstrate this process and determine its operational performance. Results from the test-scale process will be used to specify and design the full-scale process that will be installed at NSO.

14 SOLAR ENERGY↗

Smart Composite Pressure Vessels (SCPV) with Integrated Health Monitoring

The U.S. Department of Energy (DOE) is promoting and developing more energy efficient and environmentally friendly technologies that will enable America to use less petroleum. Hydrogen fuel cells – which directly convert the chemical energy in hydrogen to electricity with only water and heat as byproducts – are a very attractive solution that can enable this to happen. To date, DOE's efforts have culminated in commercial demonstration of on-board vehicular hydrogen storage systems that can allow for a driving range of greater than 300 miles. This requires storing 5 Kgs of hydrogen onboard a light vehicle. In order to store this quantity of hydrogen, the hydrogen gas needs to be stored in a composite overwrapped pressure vessel (COPV) at a very high internal pressure. The objective of the program was to demonstrate continuous and predictable health-monitoring of composite pressure vessels. A higher confidence in the operational safety of the vessels will lead to reduced burst factor of safety imposed by regulatory standards and hence will help reduce the structural wall thickness that drives the cost of the vessel. Highly optimized Type III (metal lined) and Type IV (polymer lined) COPVs that are manufactured using filament winding process have been designed and qualified for the above mentioned application. However, the main structural component of the COPVs is carbon fiber and the high cost of carbon fiber composite in a pressure vessel is a primary challenge in reducing the cost of gaseous hydrogen storage. Continuous and remote monitoring of structural health of the COPVs as well as optimization of the strength translation of carbon fibers have the potential to allow for reduced factor of safety, thereby reduced amount of carbon and associated cost of the vessel. In the current program, the project team including Steelhead Composites (SHC), University of Tennessee, Knoxville (UTK), Teijin Carbon America, Oak Ridge National Laboratory (ORNL) and LUNA designed, fabricated, and tested smart composite pressure vessels with integrated sensors. Iterative loops of design and testing using coupons, subscale STEB vessels and full size vessels proved that a new generation of high performance carbon fiber can be used for efficient design of Type 3 vessels for H2 storage. Novel analysis techniques were developed to predict the initiation and propagation of interlaminar damage inside the composite shell due to impact damage, a real threat in practical operation. Such an analysis scheme is typically not used in tank design but is an essential tool for health monitoring of composite vessels. Remote sensing of the key signatures of the tank’s operating parameters such as pressure, acceleration and humidity was demonstrated using a unique device that can wirelessly transmit and stream the data to a remote server. Fiber optic sensors were successfully integrated during fabrication of the tanks. These sensors provide a wealth of information regarding the structural health of the vessel when it is subsequently pressurized or subjected to impact damage. Excellent correlation was demonstrated between the fiber optic sensor and mechanical strain gage data, and between the measurements and analytical predictions.

08 HYDROGEN↗

Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.

47 OTHER INSTRUMENTATION↗

An integrated portable Raman sensor with nanofabricated gold bowtie array substrates for energetics detection

An integrated field-portable surface enhaned Raman scattering (SERS) sensing system has been developed and evaluated for quantitative analysis of energetics such as perchlorate (ClO4-) and trinitrotoluene (TNT) at environmentally-relevant concentrations and conditions. The detection system consists of a portable Raman spectrometer equipped with an optical fiber probe that is coupled with novel elevated gold bowtie nanostructural arrays as a sensitive and reproducible SERS substrate. Using the standard addition technique, we show that ClO4- and TNT can be quantified at concentrations as low as 0.66 mg/L (or ~6.6 M) and 0.20 mg/L (~0.9 M), respectively, in groundwater samples collected from selected military sites. This research represents the first step toward the development of a field SERS sensor which may permit rapid, in-situ screening and analysis for various applications including national security, chemical, biological and environmental detection.

Abu Hatab, Nahla A↗

Specifying Calibration of Environmental Sensors

The emergence of the Internet of Things is resulting in an increased ability of devices and systems to share data and is generating increasing interest in integrating sensors into a variety of devices deployed in the built environment. The value of such data is a function of how the data can be used. Data-producing devices and systems that enable valuable use-cases in turn can be seen as more valuable. Lighting systems are particularly interesting platforms for integrated sensors. Both indoor and outdoor lighting devices are becoming more connected, and their location is often ideally suited for hosting environmental sensors that can characterize the properties of indoor or outdoor spaces in ways that support a wide variety of use cases, from improving air quality to supporting fault diagnostics and prediction. The value of environmental-sensor-driven use-cases and the lighting systems that house them is dependent to some degree on sensor accuracy. Environmental sensors utilize a wide variety of sensing techniques or technologies and have varying accuracy. More-accurate, laboratory-grade products or reference standards are often used to characterize, refine, calibrate, adjust, and monitor devices that are deployed, or are intended to be deployed, in physical spaces of interest. Sensors or reference standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user and use-case requirements. This paper provides guidance for evaluating the performance of environmental sensors so as to ensure that they meet user or use-case needs. It describes best practices that have been developed for a) calibrating sensors to ensure some known level of accuracy, and b) determining whether calibration-laboratory accreditation meets user or use-case needs. Excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently have sensors calibrated or who have new or changing needs for sensor calibration, rationale is provided for why a specification might be used to request calibration services that meet specific needs. Commercially available calibration-service providers that are accredited for environmental-sensor calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of environmental-sensor test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

42 ENGINEERING↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Electromagnetic Acoustic Transducers in a Modular Robotic Gripper for Inspecting Tubular Components

Tubular structures are critical components in infrastructure such as power plants. Throughout their life, they are subjected to extreme conditions or suffer from defects such as corrosion and cracks. Although regular inspection of these components is necessary, such inspection is limited by safety-related risks and limited access for human inspection. Robots can provide a solution for automatic inspection. The main challenge, however, lies in integrating sensors for nondestructive evaluation with robotic platforms. As part of developing a versatile lizard-inspired tube inspector robot, in this study the authors propose to integrate electromagnetic acoustic transducers into a modular robotic gripper for use in automated ultrasonic inspection. In particular, spiral coils with cylindrical magnets are integrated into a novel friction-based gripper to excite Lamb waves in thin cylindrical structures. To evaluate the performance of the integrated sensors, the gripper was attached to a robotic arm manipulator and tested on pipes of different outer diameters. Two sets of tests were carried out on both defect-free pipes and pipes with simulated defects, including surface partial cracking and corrosion. The inspection results indicated that transmitted and received signals could be acquired with an acceptable signal-to-noise ratio in the time domain. Moreover, the simulated defects could be successfully detected using the integrated robotic sensing system.

Materials Science↗

Additively manufactured tamper evident container

A tamper evident container includes a container body having walls surrounding a cavity. The walls are composed of a non-electrically conductive material and at least one integrity sensor that is embedded in the non-electrically conductive material. A monitoring circuit is configured to monitor the tamper evident container using the at least one integrity sensor and determine a state-of-health of the tamper evident container.

Bernardin, John D.↗

Microfluidic Liquid-Liquid Extraction Chip with Integrated Raman Sensors (Phase I and Phase II Final Report)

As demand for electricity continues to increase worldwide, the world’s nuclear power generating capacity will continue to grow. Nuclear power is the most environmentally benign way of producing electricity on a large scale. The long-term successful use of nuclear power, however, is critically dependent upon adequate and safe processing and disposal of spent nuclear fuels. A very important feature of nuclear energy is that spent fuels can be reprocessed to recover fissile and fertile materials that can then be used as fresh fuel for nuclear power plants. The DOE-NE Fuel Cycle Research and Development (FCR&D) is currently developing nuclear material reprocessing technologies. In a typical nuclear fuel reprocessing system, centrifugal contactors are used as liquid-liquid extraction devices where two immiscible liquids are mixed at high speeds using a rotor, which creates a fine dispersion of droplets of organic phase in an aqueous phase that contains the analyte. Understanding the extraction efficiency at these contactors through modeling and simulation is important in the development of reprocessing technologies and the optimization of current technologies such as the PUREX process. The outcome of this program will be a liquid-liquid microfluidic flow cell chip with embedded spectroscopic sensors for the analysis of extracted analytes. This device will be useful in the optimization of new fuel reprocessing schemes as well as existing reprocessing processes by providing a microfluidic modeling platform to optimize extraction parameters. The Phase I and Phase II work developed a microfluidic chip design that allows integration of Raman and absorption fiber optic probes and successfully demonstrated the feasibility of using Raman and absorption probes to detect key analytes that partition into the aqueous and organic phases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Novel Ceramic Nanofilm-Fiber Integrated Optical Sensors for Rapid Detection of Coal Derived Synthesis Gas

The overall goal of this project is to conduct fundamental studies on advanced ceramic materials and fiber optic devices for developing new types of high temperature (>500°C) fiber optic chemical sensors (FOCS) for monitoring fossil (mainly coal) and biomass derived gases in power plants. The primary technical objective is to investigate and demonstrate the nanocrystalline doped-ceramic thin film enabled FOCS that possess desired stability, sensitivity and selectivity for in-situ, rapid gas detection in the syngas streams from gasification and combustion flue gases. This report summarizes research works of two integrated parts: (1) development of metal oxide solid thin films as sensing materials for detection and measurement of important gas components relevant to the coal- and biomass-derived syngas and combustion gas streams at high temperatures; and (2) development of fiber optic devices that are potentially useful for constructing FOCS in combination with the solid oxide thin films identified in this program.

10 SYNTHETIC FUELS↗

Building-Integrated Microscale Sensors for CO 2 -Level Monitoring

This research effort enabled the development of new classes of small-scale sensing systems that use mass and/or electrochemical sensors to detect the presence of carbon dioxide (CO 2 ). The concentration of this gas within the indoor environment is an important metric, as it can help enable the use of variable speed ventilation fans in commercial and governmental buildings, thus saving a significant amount of energy. Furthermore, there is a pressing need for enhanced CO 2 sensing to improve the comfort and productivity of people in commercial and government buildings, including academic spaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modular Subsurface Sensors and Integrated Software for Advanced Subsurface Characterization and Monitoring using Unoccupied Vehicles

The advent and subsequent proliferation of autonomous airborne, waterborne, and groundbased vehicles (i.e., “drones”) promises to broadly transform the geosciences and associated industries, including fossil energy exploration and development, mineral resource exploration and development, water-resource management, and environmental remediation. For geophysical characterization and monitoring, the prospect of programming highly repeatable and low-cost drone missions for subsurface imaging will allow for deployments in hazardous and previously inaccessible areas. Coupled with autonomous workflows for data processing, management, and visualization, drone-based geophysical characterization and monitoring will enable unprecedented, real-time insight into diverse subsurface properties and processes of scientific and engineering importance. Toward this end, the objectives of this Lab Directed Research and Development (LDRD) project were to develop new (1) instrumentation for dronebased electromagnetic induction (EMI) geophysical imaging, including separated transmitter and receivers and associated electronics, (2) software for real-time data telemetry, processing, management, and visualization. Although EMI has been previously deployed using unoccupied aerial systems (UASs), these applications failed to capitalize on the game-changing capabilities of drone platforms. Whereas drone-based data acquisition allows for collection of rich, three-dimensional (3D) multi-offset/multi-angle configurations between transmitters and receivers, past efforts have relied on conventional instrumentation that was designed for ground-based data collection with the transmitter and a single receiver housed in the same unit; nor did these previous applications demonstrate real-time delivery of results to support rapid management decisions in the field. In this 1-year project, we (1) designed and constructed new lightweight independent transmitter and receiver antenna platforms that communicate with a laptop computer; (2) developed software to control data acquisition, manage/transfer data, and visualize data as its collected; and (3) demonstrated the operation of the new hardware and software systems in a ground-based field test. Our work entails major technological advances for EMI and established a foundation on which to build a new drone-based, real-time geophysical EMI imaging capability to support diverse challenges facing the nation.

47 OTHER INSTRUMENTATION↗