Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon strip detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Electrical performances of pre-production staves for the ATLAS ITk Strip Detector Upgrade

The ATLAS experiment is currently preparing for an upgrade of the inner tracking detector for the High-Luminosity LHC. The new tracker, ITk, employs an all-silicon detector with outer strip layers. The building block of the ITk strip barrel is the stave which consists of a low-mass support structure hosting the common electrical, optical and cooling services as well as 28 silicon modules. In this contribution, we outline the challenging aspects of the stave pre-production testing phase at Brookhaven National Laboratory. Here, the electrical characterization of these staves, hosting the final design of all ASICs, will be discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Specifications and pre-production of n + -in-p large-format strip sensors fabricated in 6-inch silicon wafers, ATLAS18, for the Inner Tracker of the ATLAS Detector for High-Luminosity Large Hadron Collider

Abstract The ATLAS experiment is constructing new all-silicon inner tracking system for HL-LHC. The strip detectors cover the radial extent of 40 to 100 cm. A new approach is adopted to use p-type silicon material, making the readout in n + -strips, so-called n + -in-p sensors. This allows for enhanced radiation tolerance against an order of magnitude higher particle fluence compared to the LHC. To cope with varying hit rates and occupancies as a function of radial distance, there are two barrel sensor types, the short strips (SS) for the inner 2 and the long strips (LS) for the outer 2 barrel cylinders, respectively. The barrel sensors exhibit a square, 9.8 × 9.8 cm 2 , geometry, the largest possible sensor area from a 6-inch wafer. The strips are laid out in parallel with a strip pitch of 75.5 μm and 4 or 2 rows of strip segments. The strips are AC-coupled and biased via polysilicon resistors. The endcap sensors employ a “stereo-annulus” geometry exhibiting a skewed-trapezoid shapes with circular edges. They are designed in 6 unique shapes, R0 to R5, corresponding to progressively increasing radial extents and which allows them to fit within the petal geometry and the 6-inch wafer maximally. The strips are in fan-out geometry with an in-built rotation angle, with a mean pitch of approximately 75 μm and 4 or 2 rows of strip segments. The eight sensor types are labeled as ATLAS18xx where xx stands for SS, LS, and R0 to R5. According to the mechanical and electrical specifications, CAD files for wafer processing were laid out, following the successful designs of prototype barrel and endcap sensors, together with a number of optimizations. A pre-production was carried out prior to the full production of the wafers. The quality of the sensors is reviewed and judged excellent through the test results carried out by vendor. These sensors are used for establishing acceptance procedures and to evaluate their performance in the ATLAS collaboration, and subsequently for pre-production of strip modules and stave and petal structures.

Instruments & Instrumentation↗

The Hitomi X-Ray Observatory, Part 2

When it was launched on 17 February 2016, the Hitomi X-ray Observatory carried four kinds of new-generation x-ray instruments—the Soft X-ray Spectrometer (SXS), the Soft X-ray Imager (SXI), the Hard X-ray Imager (HXI), and the Soft Gamma-ray Detector (SGD). All four instruments were turned on and were in the process of activation at the time of loss of contact on 26 March 2016. In the time it was operational, Hitomi was able to provide researchers with a trove of ground-breaking scientific results. Initial results demonstrated that the instruments were meeting or exceeding requirements and that Hitomi was on its way to pioneering a new era of broad-band and high-resolution x-ray spectroscopy. The results published here summarize the in-flight instrument performance, calibration, and data processing accomplishments of the observatory. Of the papers accepted for publication in this special section, 17 were presented in Part 1 in the January-March 2018 issue of JATIS (Journal of Astronomical Telescopes, Instruments, and Systems). Ten more papers are presented here as Part 2 in the April-June 2018 issue. These papers cover the detailed in-flight performance of the four state-of the-art instruments on-board the Hitomi X-Ray Observatory. These instruments were extremely diverse in their design and principles of operation, ranging from low temperature x-ray calorimeters for high-resolution spectroscopy, CCDs (Charge-Coupled Devices) for wide field imaging, high fill-factor grazing incidence x-ray optics, including multilayer x-ray optics and silicon strip and CdTe strip detectors for high-energy imaging, and a Si/CdTe Compton cameras for extending the bandpass out to 600 kiloelectronvolts. All of these instruments operated as expected and for sufficient time to validate their operating principles and carry out first light scientific investigations, published elsewhere. Collectively, these instruments, all co-aligned and operated simultaneously, provided a tool for astronomers with unprecedented resolution and broadband sensitivity for investigating high-energy processes throughout the universe. These papers serve as part of the Hitomi legacy and will guide the next generation of instruments planned for future missions.

Kelley, Richard L.↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon pinhole strip defects and their impact on ATLAS Inner Tracker HV current measurement

In preparation for the High-Luminsity LHC (HL-LHC) [1], the ATLAS detector will undergo major detector upgrades, including the replacement of the current Inner Detector with the new all-silicon Inner Tracker (ITk) [2]. The ITk consists of a pixel detector close to the beamline surrounded by a large-area strip detector. During detector production, the electrical properties of silicon sensors and readout electronics must be characterized through a series of quality control (QC) and quality assurance tests. These tests ensure any defect is captured at the earliest possible stage. One such defect, callled a pinhole, occurs when the strip implant and the metal readout electrode are shorted through the intermediary dielectric layer. Notably, the introduction of pinholes during module assembly and pinhole effects on completed modules, especially on leakage current measurement circuitry, have never been studied. In this paper, we investigate the effect of such connections on the sensor leakage current measurements of completed modules and introduce new ways to locate pinholed strips. Here, with minor modifications to testing procedures, such defects are shown not to impede module testing or performance.

FOS: Physical sciences↗

The ATLAS ITk Strip detector system for the Phase-II LHC upgrade

In the view of the luminosity increase foreseen by the High-Luminosity Large Hadron Collider program at CERN, the ATLAS experiment initiated an R&D program to replace its complete inner detector (ID) system. The new Inner Tracker (ITk) system, anticipated to be installed by 2028, will be a new all-silicon based tracker including Strip and Pixel detector technologies. The new detector is designed to meet the requirements of operating under a harsh environment namely, high radiation levels, increased pile-up and data rates while decrease the material budget and maintain or even improve the performance. The Strip project has advanced in several areas the last years while facing challenges moving from pre-production to production. Here, this manuscript gives an overview of the ITk Strip system and describes the advancements and challenges to date.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The STAR Forward Silicon Tracker

The Forward Silicon Tracker (FST) is a pivotal component of the forward upgrade of the Solenoidal Tracker at RHIC (STAR), designed to discern hadron charge signs with a momentum resolution better than 30% for 0.2 < p T < 2GeV/c in the 2.5 < η < 4 pseudorapidity range. Its compact design features three disks along the beam direction, minimized material budget, and scattering effects. The FST uses Hamamatsu’s p-in-n silicon strip sensors with a double metal layer that enables efficient signal routing to the readout electronics, enhancing overall detector performance. The flexible hybrid boards, essential for the readout system, are constructed with Kapton and copper layers to optimize signal handling and power distribution. These boards connect silicon strips to analogue pipeline ASIC APV25-S1 chips, which read up to 128 channels each. A cooling system with nonconducting, volatile NOVEC 7200 coolant at 22.2 °C mitigates ASIC-generated heat. Furthermore, the FST enhances forward tracking performance at STAR as an integral part of the forward upgrade.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Silicon strip defects and their impact on electrical performance of readout electronics

Abstract In preparation for the High Luminosity LHC (HL-LHC) runs, the ATLAS inner detector will be completely replaced with an all silicon Inner Tracker (ITk). Hybrid silicon pixel modules will be used for the innermost tracking layers, and silicon micro-strip detectors will be used the outer layers of the tracker. During the production of the detector, the sensors, readout electronics, and other components will undergo a series of quality control (QC) and quality assurance tests. Defects in the fabrication of the sensors will be flagged early in the manufacturer's and ATLAS QC tests. A study of the influence of sensor defects was performed to assess the characteristics of these defects in completed modules, and whether any defect posed a risk to the operation of the front-end readout electronics. All defects were found to have no impact on the performance of the front-end readout electronics for healthy amplifier channels, and defects that short the coupling between the strip implant and the metal readout electrode were only noticeable for strip leakage currents in excess of 250 nA, beyond the end-of-life currents expected for most sensors at the HL-LHC.

Instruments & Instrumentation↗

Operation and performance of the ATLAS semiconductor tracker in LHC Run 2

The semiconductor tracker (SCT) is one of the tracking systems for charged particles in the ATLAS detector. It consists of 4088 silicon strip sensor modules. During Run 2 (2015–2018) the Large Hadron Collider delivered an integrated luminosity of 156 fb ₋1 to the ATLAS experiment at a centre-of-mass proton-proton collision energy of 13 TeV. The instantaneous luminosity and pile-up conditions were far in excess of those assumed in the original design of the SCT detector. Due to improvements to the data acquisition system, the SCT operated stably throughout Run 2. It was available for 99.9% of the integrated luminosity and achieved a data-quality efficiency of 99.85%. Detailed studies have been made of the leakage current in SCT modules and the evolution of the full depletion voltage, which are used to study the impact of radiation damage to the modules.

47 OTHER INSTRUMENTATION↗

Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents

Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and physics analysis. This paper presents simulations and measurements of the leakage current in the ATLAS pixel detector and semiconductor tracker as a function of location in the detector and time, using data collected in Run 1 (2010-2012) and Run 2 (2015-2018) of the Large Hadron Collider. The extracted fluence shows a much stronger |z|-dependence in the innermost layers than is seen in simulation. Furthermore, the overall fluence on the second innermost layer is significantly higher than in simulation, with better agreement in layers at higher radii. These measurements are important for validating the simulation models and can be used in part to justify safety factors for future detector designs and interventions.

47 OTHER INSTRUMENTATION↗

Elemental Spectra from the First ATIC Flight

The Advanced Thin Ionization Calorimeter (ATIC) instrument is a balloon-borne experiment designed to measure the composition and energy spectra of Z = l to 26 cosmic rays over the energy range from approx. 10(exp 11) to approx. 10(exp 14) eV. The instrument consists of a silicon matrix charge detector, plastic scintillator strip hodoscopes interleaved with graphite interaction targets, and a fully active Bismuth Germanate (BGO) calorimeter. ATIC had two successful Long Duration Balloon flights launched from McMurdo Station, Antarctica in 2000 and 2002. In this paper, spectra of various elements measured during the first 16 day flight are presented.

Ahn, H. S.↗

Alignment of the CLAS12 central hybrid tracker with a Kalman Filter

Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5 T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10 µm, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts

Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring strips. However, to effectively extract the inherent positional information, the lateral spacing of the straight strips must be comparable to or preferably smaller than the full extent of the incident charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the incident charge with a pitch appreciably larger than the charge cloud.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and evaluation of large area strip sensor prototypes for the ATLAS Inner Tracker detector

The ATLAS community is facing the last stages prior to the production of the upgraded silicon strip Inner Tracker for the High-Luminosity Large Hadron Collider. An extensive Market Survey was carried out in order to evaluate the capability of different foundries to fabricate large area silicon strip sensors, satisfying the ATLAS specifications. The semiconductor manufacturing company, Infineon Technologies AG, was one of the two foundries, along with Hamamatsu Photonics K.K., that reached the last stage of the evaluation for the production of the new devices. The full prototype wafer layout for the participation of Infineon, called ATLAS17LS-IFX, was designed using a newly developed Python-based Automatic Layout Generation Tool, able to rapidly design sensors with different characteristics and dimensions based on a few geometrical and technological input parameters. Here we present the layout design process and the results obtained from the evaluation of the new Infineon large area sensors before and after proton and neutron irradiations, up to fluences expected in the inner layers of the future ATLAS detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Position sensitive device technologies for particle physics

Here, I will give a brief overview of the use of position sensitive devices for particle physics. I will focus on silicon-based systems only. In addition to the depiction of a suite of recently designed, built, and operated detectors I will also introduce planned near term additions. I will conclude with a brief outlook regarding challenges for silicon detector applications for future colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗