Single-Event Effect Test Report Analog Devices LTC1604AIG#90117 ADC

This study is to characterize the destructive single-event latchup (SEL) susceptibility of the LTC1604AIG#90117 (LTC1604) analog/digital converter (ADC). The device was monitored for SEL current events on the power supplies during exposure to a heavy ion beam at Lawrence Berkeley National Laboratory (LBNL) 88-inch Cyclotron. Testing was performed on September 11, 2021.

single-event latchup (SEL)↗

Single-Event Effect Testing of the Analog Devices AD8041ARZ Operational Amplifier

This study was undertaken to determine the single event transient distribution of a transimpedance amplifier configuration of the AD8041 Operational Amplifier. The AD8041 is made in a bipolar technology and the application of interest has a bipolar supply of ±5 V. The device was monitored for transient events on the output voltage during exposure to a heavy ion beam at Lawrence Berkeley National Laboratory’s (LBNL) 88-inch Cyclotron.

Matthew B. Joplin↗

Single-Event Effect Testing of the ON Semiconductor BSS123 N-Channel Logic Level Enhancement Mode FET and the Vishay Si1013R P-Channel MOSFET

This study was undertaken to determine the single event effect (SEE) susceptibility of two different MOSFET components. Heavy-ion testing was conducted at the Lawrence Berkeley National Laboratory (LBNL) Berkeley Accelerator Space Effects (BASE) Facility 88” Cyclotron. Its purpose was to evaluate these devices as candidates for use on Goddard Modular SmallSat Architecture (GMSA) adapter board for the GTOSat project.

Michael J Campola↗

Single-Event Effects Test Report Linux Operating System Configurations on TUL PYNQ-Z2

This study was undertaken to determine the single-event functional interrupt (SEFI) susceptibility on different Linux operating system configurations. The device-under-test (DUT) was the Xilinx Zynq-7020 SoC on the TUL PYNQ-Z2 board. The device was monitored for kernel panics or hangs, classified as SEFIs, to observe any differences in the SEFI cross sections between operating system configurations. The primary purpose of this experiment was to observe if the number of drivers installed in a Linux system affects its overall execution reliability.

Seth S Roffe↗

NASA Electronic Parts and Packaging Field Programmable Gate Array Single Event Effects Test Guideline Update

The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.

Field Programmable Gate Array (FPGA)↗

Single Event Effects Test Results for Advanced Field Programmable Gate Arrays

Reconfigurable Field Programmable Gate Arrays (FPGAs) from Altera and Actel and an FPGA-based quick-turnApplication Specific Integrated Circuit (ASIC) from Altera were subjected to single-event testing using heavy ions. Both Altera devices (Stratix II and HardCopy II) exhibited a low latchup threshold (below an LET of 3 MeV-cm2/mg) and thus are not recommended for applications in the space radiation environment. The flash-based Actel ProASIC Plus device did not exhibit latchup to an effective LET of 75 MeV-cm2/mg at room temperature. In addition, these tests did not show flash cell charge loss (upset) or retention damage. Upset characterization of the design-level flip-flops yielded an LET threshold below 10 MeV-cm2/mg and a high LET cross section of about lxlO-6 cm2/bit for storing ones and about lxl0-7 cm2/bit for storing zeros . Thus, the ProASIC device may be suitable for critical flight applications with appropriate triple modular redundancy mitigation techniques.

Field Programmable Gate Arrays↗

Linear Systems LSK389 and LSK489 Dual N-Channel JFET Amplifier Total Ionizing Dose and Single-Event Effects Test Report

The purpose of these tests was to characterize the susceptibility of the LSK389 and LSK489 Dual N-Channel JFET from Linear Systems to Single-Event Latchup due to heavy ions and to Total Ionizing Dose (TID) degradation at -65 °C and intermediate dose rate. The test was carried out to assess suitability of the amplifiers for the Ocean Color instrument (OCI) on the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft.

Ray Ladbury↗

Single Event Effects Test Results for the Actel ProASIC Plus and Altera Stratix-II Field Programmable Gate Arrays

This work describes radiation testing of Actel's ProASIC Plus and Altera's Stratix-II FPGAs. The Actel Device Under Test (DUT) was a ProASIC Plus APA300-PQ208 nonvolatile, field reprogrammable device which is based on a 0.22micron flash-based LVCMOS technology. Limited investigation has taken place into flash based FPGA technologies, therefore this test served as a preliminary reference point for various SEE behaviors. The Altera DUT was a Stratix-II EP2S60F1020C4. Single Event Upset (SEU) and Single Event Latchup (SEL) were the focus of these studies. For the Actel, a latchup test was done at an effective LET of 75.0 MeV-sq cm/mg at room temperature, and no latchup was detected when irradiated to a total fluence of 1 x 10(exp 7) particles/sq cm. The Altera part was shown to latchup at room temperature.

heavy ions↗

Initial Single Event Effects Testing of the Xilinx Virtex-4 Field Programmable Gate Array

We present initial results for the thin epitaxial Xilinx Virtex-4 Fie ld Programmable Gate Array (FPGA), and compare to previous results ob tained for the Virtex-II and Virtex-II Pro. The data presented was a cquired through a consortium based effort with the common goal of pr oviding the space community with data and mitigation methods for the use of Xilinx FPGAs in space.

single event effects↗

Variable Depth Bragg Peak Method for Single Event Effects Testing

Traditionally, accelerator SEE testing is accomplished by removing the tops of packages so that the IC chips are accessible to heavy ions. However, ICs in some advanced packages cannot be de-lidded so a different approach is used that involves grinding and/or chemically etching away part of the package and the chip from the back side. The parts are then tested from the back side with ions having sufficient range to reach the sensitive volume. More recently, the entire silicon substrate in an SOI/SRAM was removed, making it possible to use low-energy ions with shorter ranges. Where removal of part of the package is not possible, facilities at Michigan State, NASA Space Radiation Laboratory, GANIL (France) and GSI (Germany) offer high-energy heavy ions with long ranges so that the ions can reach the devices' sensitive volumes without much change in the LET. Unfortunately, a run will typically involve only one ion species having a single energy and LET due to the long time it takes to tune a new energy. The Variable Depth Bragg Peak (VDBP) method is similar to the above method in that it involves the use of high-energy heavy ions that are able to pass through the packaging material and reach the device, obviating the need to remove the package. However, the method provides a broad range of LETs from a single ion by inserting degraders in the beam that modify the ion energy and, therefore, the LET. The crux of the method involves establishing a fiduciary point for degrader thickness, i.e., where the Bragg peak is located precisely at the sensitive volume in the device, for which the measured SEU cross-section and the ion LET are both also maxima and can be calculated using a Monte-Carlo program, TRIM. Once the fiduciary point has been established, calibrated high density polyethylene (HDPE) degraders are inserted into or removed from the beam to vary the ion LET at the device in a known manner. After each change of degrader thickness, the SEU cross-section is measured and the corresponding LET calculated from the change in degrader thickness. That information is used to generate a plot of cross-section as a function of ion LET. The advantages of this approach are that the part does not have to be de-lidded and a broad range of LETs is available from a single heavy ion without having to go to non-normal angles of incidence to change the "effective" LET. As we will show, it is possible to obtain an entire curve of cross-section versus LET using just two or three ions. Fig. 1 shows curves of cross-section vs LET for a Freescale 4 Mbit SOI/SRAM measured at the 88" Cyclotron at Berkeley and at NSRL. The open symbols are the data obtained from Berkeley for top-side and back-side irradiation. The solid data points are for the data obtained at NSRL using a device for which the package was intact. The data are for Iron and Gold and cover a range of LETs from 4 MeV.cm2/mg to 84 MeV.cm2/mg. The agreement between the data obtained from Berkeley and from NSRL is excellent, demonstrating that the VDBP method is capable of providing accurate values of cross-section versus LET, at least for the 4 Mbit SRAM. Details of the technique will be included in the final presentation.