Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stand-alone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Inkjet Printing to Scale Perovskite and Silicon Tandem Solar Cell: Cooperative Research and Development Final Report, CRADA Number CRD-17-00690

The proposed project seeks to develop a method for inkjet printing of the active layer in perovskite solar cells for application in stand-alone products or added to conventional silicon solar cells in a mechanically-stacked tandem configuration. This technology presents significant advanced manufacturing challenges and opportunities in getting to scale, including development of novel uses for printing technologies and development of predictive quality control techniques.

14 SOLAR ENERGY↗

Salt International Collaborations FY24 Update

This report summarizes the international collaborations conducted by Sandia funded by the US Department of Energy Office (DOE) of Nuclear Energy (DOE-NE) Spent Fuel and Waste Science & Technology (SFWST) as part of the Sandia National Laboratories Salt R&D and Salt International work packages. This report satisfies the level-three milestone M3SF-24SN010303063. Several stand-alone sections make up this summary report, each completed by the participants. The sections discuss granular salt reconsolidation (KOMPASS/MEASURES), engineered barriers (RANGERS), numerical model comparison (DECOVALEX), an NEA Salt Club working group on the development of scenarios as part of the performance assessment development process, and progress on seal percolation experiments with German colleagues at Gesellschaft für Anlagen- und Reaktorsicherheit (GRS). Finally, we summarize events related to the US/German Workshop on Repository Research, Design and Operations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proceedings for the Workshop on Applied Nuclear Data Activities 2024

The Workshop for Applied Nuclear Data Activities (WANDA) is designed to increase communication among nuclear data (ND) users in multidisciplinary federal programs, ND producers, ND funders, and other ND experts. It also presents an opportunity to cross-pollinate ideas as well as introduce ND gaps identified by federal programs to ND experts and ND capabilities to the various federal ND users. WANDA 2024 included five technical sessions, three of which focused on Fusion Energy Sciences (FES)—FES Fusion Neutronics, FES Tritium Production, and FES Material Damage—and two stand-alone sessions—Isotopes and Targetry for Nuclear Data and Uncertainty Quantification. The FES sessions successfully brought new voices to the WANDA discussions, expanding the application space in which nuclear data are critical. FES programs need accurate nuclear data with realistic uncertainty quantification to properly estimate, for example, shielding, activation, tritium production, helium production, structural material integrity, and superconducting magnet operation. This includes a variety of projectile (neutrons, photons, charged particles) and target atoms. One of the action items common to all the FES sessions was a need to perform sensitivity studies to identify the prioritization of nuclear data needs. The Isotopes and Targetry session highlighted the many capabilities available to produce high-quality targets for nuclear data measurements, including 3D printing with spherical powders, combustion synthesis coupled with spin coating & electrospraying, inkjet printing, and isotopic doping. These new methods open doors for more accurate measurement, but it was also stressed that sample characterization following any method of fabrication is of the highest importance to accurately interpret nuclear data measurement results that used that sample. The Uncertainty Quantification (UQ) session was broken into two categories: nuclear data uncertainty quantification and the use of that uncertainty quantification. Thematic to the UQ session was the loss of information when going from nuclear data measurement, to evaluation, to evaluated file, and finally to neutron transport calculations. Current evaluated ND libraries typically only contain covariances, which assume that the probability distributions are Gaussian. Beyond being a simplified assumption for many evaluations, this can lead to negative values on many observables when attempting to sample the covariance. The covariance format, however, is very efficient in that a simple set of linear equations can transform uncertainty from parameters or cross sections to the application of interest. Focused collaboration is needed between nuclear data evaluators and nuclear data users to ensure that needs are being met.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Passivated Contacts for Direct Wafer Product (Final Technical Report)

This TCF project developed a thin-oxide (SiO 2 )/polycrystalline silicon (poly-Si) passivated contact solar cell on CubicPV's (formally 1366 Technologies, Inc.) Direct Wafer® Product (DWP) kerfless wafers. The project used two NREL-developed technologies described in U.S. Patent No. 9,911,873, Hydrogenation of Passivated Contacts and U.S. Patent Application Serial No. 15/890,172, Doped Passivated Contacts . The project was motivated by a potential higher efficiency cell (compared to a PERC cell) using passivated contacts on the ultra-low cost kerfless wafers grown using the Direct Wafer process. The hope was to accelerate market adoption of the cell and wafer by delivering the lowest LCOE in the PV industry. The project tested both n-type and p-type SiO 2 /poly-Si passivated contacts grown by thermal oxidation and plasma enhanced chemical vapor deposition (PECVD) of the poly-Si layer on DWP with varying wafer resistivities. Both deposition techniques are industry standards and thus economically viable methods for commercializing the contacts. The results indicated that both n-type and p-type poly-Si passivated contacts can be formed on polycrystalline DWP wafers, but implied open-circuit voltages (i Voc ) were limited to below 0.65 mV (compared with ~ 730 mV on n-Cz wafers). Diffusion of H to the Si/SiO 2 /poly-Si interface was key to obtaining high i Voc values. In this study, H was diffused from a high-temperature SiN x layer deposited over the poly-Si layer during a high-temperature firing step, similar to one used for screen printed metals. The study concluded that poly-Si passivated contacts on DWP wafers passivated the surface of the wafers as well as PERC passivated surfaces, which use a less expensive dielectric layer stack. The project showed that Direct Wafer Product wafers grown by CubicPV could produce high i Voc values (~0.647 mV), which could produce a cell over 20% efficient with proper processing and metallization. These cells, though not economically viable in 2024 as a stand-alone cell, could be integrated with a wide-bandgap top solar cell to form a two-junction tandem cell that could be viable under certain circumstances. This is because the bottom cell of a 30%, two-terminal tandem only needs to be a 20% cell under one-sun conditions. Thus, the DWP could be an ideal low-cost wafer for tandems. The project also revealed that a TOPCon type cell could be formed on a p-type DWP wafer using a P-diffused emitter and a p-type poly-Si contact. In fact, the p-type version of the poly-Si contact out-performed the n-type version for a variety of wafer resistivities, from highly doped to lowly doped. This curiosity requires more work to understand because on Cz wafers, the n-type poly-Si contact is of much higher quality than the p-type version.

14 SOLAR ENERGY↗

Current Practices in Distribution Utility Resilience Planning for Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using Institute of Electrical and Electronics Engineers (IEEE) 1366-2022, which defines major events as an event that exceeds reasonable design and/or operational limits of the electric power system. Resilience planning is focused on major event days and reliability planning is focused on nonmajor event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on winter storms in which the primary hazards are heavy snowfall, freezing rain, ice, extreme cold, severe wind, and flooding. These hazards can also contribute to generation shortages, resulting in bulk power system impacts that have consequences for the distribution system, such as load shedding. Stand-alone reports focusing on wildfires and nonwinter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Advanced Pretreatment/Anaerobic Digestion (APAD) Technology for Increased Conversion of Sewage Sludge to Bio-natural Gas in Small-scale Wastewater Plants of less than Five tons Sewage Sludge a Day

The problem today of energy production from sewage sludge at small-scale is that conventional Anaerobic Digestion (AD) as used today at Wastewater Treatment Facilities (WWTF) produces too little energy for warrant use of the biogas. It further leaves 50% or more of the waste behind after the treatment. To overcome this problem, we proposed a novel concept based on Advanced Wet Oxidation & Steam Explosion (AWOEx) of the recalcitrant parts of sewage sludge left behind after AD. We further suggest upgrading biogas to renewable natural gas (RNG) using gaseous fermentation of biogas with hydrogen added by a new methanogen. Overall, the DOE funded Advanced Pretreatment & Anaerobic digestion (APAD) project showed significant improvements over current practice. The project demonstrated that AWOEx followed by AD significantly enhanced the carbon conversion efficiency from 37% to 62%, an increase of 68%. This is far higher than the metric for the specific FOA of an increase of 50%. Besides, the project showed high efficiency of our biological conversion of biogas into RNG when using a new isolate of Methanothermobacter wolfeii resulting in a 100% increased production of a refined biogas with maximum 5% CO2. With both AWOEx pretreatment and biogas upgrading, the project showed a CCE of ca. 83%, far higher than any previous work on sewage sludge. Besides over 200% higher amount of energy in the form of RNG, the APAD concept will reduce disposal cost due to significant reduction in the concentration of final sludge product after APAD. The APAD technology can operate as a bolt-on to a conventional AD plant for improving conversion of the residual organics after AD as done in this DOE project. It can further be implemented as a stand-alone process with AWOEx followed by AD for WWTF’s currently operating without AD.

09 BIOMASS FUELS↗

The ORNL Moderator Test Station Science Case

Oak Ridge National Laboratory (ORNL) hosts two world-leading slow neutron sources, the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), and is currently developing the technical design for a Second Target Station (STS) for the SNS. Upon completion of the STS project, ORNL will be uniquely positioned to optimize each of its three neutron sources, the SNS First Target Station (FTS), the STS, and HFIR, in a complementary way. Among the essential aspects of a re-imagined FTS and the current STS design are high-brightness parahydrogen moderators—moderators which are optimized for high per-unit-area neutron brightness rather than integrated-across-large-area neutron intensity. The high-brightness moderators proposed for the STS will, for the brightness metric, significantly outperform the coupled moderators currently on the FTS for appropriately optimized neutron beamlines, provided the moderating hydrogen is converted to near-equilibrium levels of parahydrogen (approximately 99.8% at 20 K). The original FTS moderators, by contrast, were conservatively designed to be relatively insensitive to the exact ortho:para ratio, with a consequent loss in performance. As a result, a redesign of the FTS moderators assuming fully converted parahydrogen could result in significant performance improvements on the FTS coupled moderators, and more consistent performance over time for all hydrogen moderators. This “parahydrogen problem” is a long-standing challenge for the effective implementation of hydrogen cold moderators at high-power neutron sources. In addition, the development of new moderator concepts, whether based on previously unused materials, structured heterogeneous arrays, or even simply on changes in overall shape and size is significantly restricted at a large-scale production facility intended to use the resulting neutron beams. Accordingly, moderators for production neutron sources are often designed in a very conservative, low-risk fashion, even though this compromises the absolute neutronic performance. Advanced moderator concepts worthy of study include features that could not be tested without redesigning and redeploying the entire existing reflector, shielding, and neutron beamline installation, making such development efforts far more expensive than building a stand-alone test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capability Building Progression of an Insider Threat Mitigation Program at International Nuclear Power Plant

With threats to nuclear facilities continuously evolving, the development and implementation of insider threat mitigation programs is increasingly important. The Office of International Nuclear Security within the U.S. Department of Energy’s National Nuclear Security Administration (DOE/NNSA’s) developed the “Insider Threat Mitigation Program: Facility Implementation Handbook” to assist organizations to be better positioned to minimize the risks posed by malicious insiders. The handbook identified eight elements that contribute to the development and implementation of insider threat mitigation programs. This report outlines the development of a capability building progression of an insider threat mitigation program at international nuclear power plants. This information can be stand-alone or be accompanied by a technical exchange with subject matter experts to support development and implementation of programs with interested international partners.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Consistent $\overline{ν}$ evaluation for minor U isotopes with $\tt{CGMF}$

Following several successful prompt $\overline{ν}$ evaluations using $\tt{CGMF}$, including consistent evaluations for minor Pu isotopes, we detail in this report our efforts to perform a consistent $\overline{ν}$ evaluation for minor U isotopes during FY25. Although we have not yet produced a finalized evaluation, we present the progress that we have made towards such an evaluation for 232,233,234,236,237,239 U prompt $\overline{ν}$. Our milestone explicitly calls out evaluations for 233 U, 234 U, and 236 U, however, to better constrain the model with reliable experimental $\overline{ν}$ data, we also include 235 U and 238 U in the evaluation procedure. Then, we additionally produce evaluations for 232 U, 237 U and 239 U $\overline{ν}$ as a byproduct. Elsewhere, we will report our efforts on a stand-alone 233 U $\overline{ν}$ evaluation. This report is organized in the following manner. In Sec. 2, we briefly outline the updates to CGMF that were needed to be able to calculate all of these minor U fission reactions. The experimental data overview is given in Sec. 3. The evaluation methodology and results are presented in Secs. 4 and 5, respectively. Finally, we conclude and outline work for FY26 in Sec. 6.

07 ISOTOPE AND RADIATION SOURCES↗

Synergistic Pathways for Water Security in Emerging Sectors: Data Centers and Modern Nuclear Facilities

Stand-alone data centers, nuclear-powered data centers, and novel nuclear facilities such as fusion plant and small modular reactors (SMRs) are rapidly expanding, water-intensive sectors that present a significant challenge to the water-for-energy nexus. Their large-scale consumption of water for cooling systems not only reduces downstream water quantity but also degrades quality, demanding an integrated approach by stakeholders to understand and address these impacts through infrastructure planning and development.

42 ENGINEERING↗

ILAMBv2.7 benchmarking results comparing E3SMv2.1 land-atmosphere coupled (BGCv2LNDATM) and stand alone land (ELM) simulations with CMIP6 emission driven historical simulations

This dataset contains land model benchmarking results for the Energy Exascale Earth System Model version 2.1 (E3SMv2.1), including outputs from both coupled biogeochemistry simulations and stand-alone land model simulations. These results are compared against several emission-driven historical simulations from the Coupled Model Intercomparison Project Phase 6 (CMIP6). Benchmarking was conducted using the International Land Model Benchmarking (ILAMB) package, version 2.7 (ILAMBv2.7). CMIP6 model outputs were sourced from the Earth System Grid Federation (ESGF), while the E3SMv2.1 results were derived from raw model outputs. These outputs underwent processing steps such as time serialization, conservative regridding, and data standardization to ensure comparability. For spatial interpolation, the Earth System Modeling Framework (ESMF) tool, ESMF_RegridWeightGen, was employed to generate regridding weights, enabling the transformation of E3SM’s native cubed-sphere grid to a regular latitude-longitude grid.

Feng, Sha [PNNL]↗

Hybrid Fuel Cell Systems for Heavy-Duty Trucks: Configuration, Heat Rejection, and Performance

Low-temperature polymer electrolyte membrane fuel cell systems can achieve higher efficiency than diesel engines, but heat rejection remains a major challenge in class-8 heavy-duty fuel cell trucks. For the same rated power, the radiator heat load is greater than that in a diesel engine, while the allowable operating temperatures are lower. This work proposes and evaluates 400 kWe fuel cell–battery hybrid (FCH) platforms and operating strategies that manage heat rejection without enlarging the radiator frontal area. Three FCH platforms are identified, each varying in fuel cell system (FCS) rated power, battery energy storage system (ESS) capacity, and maximum stack coolant exit temperature (T h1 ). All three satisfy key system and vehicle requirements, including 175 kWe FCS power at top sustained speed, 400 kWe FCH power on a 6% grade climb, a target stack power density (PD) of 750 mW e /cm 2 , and heat rejection constraints. The first FCH has the smallest FCS, the largest ESS, and a T h1 of 90 °C. The second achieves the highest PD of 840 mW e /cm 2 at a T h1 of 95 °C. The third has the largest FCS, the smallest ESS, and a T h1 of 102 °C. At a Th1 of 115 °C, the platform can be configured as a stand-alone 400 kWe(net) FCS without hybridization, but the achievable PD drops to 460 mW e /cm 2 .

25 ENERGY STORAGE↗

On the predictability of turbulent fluxes from land: PLUMBER2 MIP experimental description and preliminary results

Accurate representation of the turbulent exchange of carbon, water, and heat between the land surface and the atmosphere is critical for modelling global energy, water, and carbon cycles in both future climate projections and weather forecasts. Evaluation of models' ability to do this is performed in a wide range of simulation environments, often without explicit consideration of the degree of observational constraint or uncertainty and typically without quantification of benchmark performance expectations. We describe a Model Intercomparison Project (MIP) that attempts to resolve these shortcomings, comparing the surface turbulent heat flux predictions of around 20 different land models provided with in situ meteorological forcing evaluated with measured surface fluxes using quality-controlled data from 170 eddy-covariance-based flux tower sites. Predictions from seven out-of-sample empirical models are used to quantify the information available to land models in their forcing data and so the potential for land model performance improvement. Sites with unusual behaviour, complicated processes, poor data quality, or uncommon flux magnitude are more difficult to predict for both mechanistic and empirical models, providing a means of fairer assessment of land model performance. When examining observational uncertainty, model performance does not appear to improve in low-turbulence periods or with energy-balance-corrected flux tower data, and indeed some results raise questions about whether the energy balance correction process itself is appropriate. In all cases the results are broadly consistent, with simple out-of-sample empirical models, including linear regression, comfortably outperforming mechanistic land models. In all but two cases, latent heat flux and net ecosystem exchange of CO 2 are better predicted by land models than sensible heat flux, despite it seeming to have fewer physical controlling processes. Land models that are implemented in Earth system models also appear to perform notably better than stand-alone ecosystem (including demographic) models, at least in terms of the fluxes examined here. The approach we outline enables isolation of the locations and conditions under which model developers can know that a land model can improve, allowing information pathways and discrete parameterisations in models to be identified and targeted for future model development.

54 ENVIRONMENTAL SCIENCES↗

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SARS-CoV-2 variant nanobodies and constructs comprising such nanobodies

A large and highly diverse nanobody library was constructed and screened against multiple variants of SARS-COV-2 to find nanobodies with high sensitivity and specificity for the variants. Four rounds of positive selection against a panel of six diverse SARS-COV-2 variant RBDs was performed with our high-diversity. At least 59 of these nanobodies were found to work well against Alpha, Beta, Gamma, Delta, Kappa, Lambda and Mu with some overlap efficacy against other variants. These nanobodies have efficacy as stand-alone nanobodies and as a construct comprising nanobodies linked to the human IgG1 constant fragment (Fc) (nanobody-hFc constructions or nb-hFcs) to make enhanced humanized sdAbs with all the attributes of nanobodies with improved half-life and optimized effector functions. Several promising nanobodies that neutralize the original SARS-COV-2 and several of its variants have been identified, including Delta, with high efficacy. In particular, a subset of these nanobodies bind to the Omicron RBD.

Harmon, Brooke Nicole↗

Techno-Economic Analysis of Sorbent-Based Direct Air Capture Informed by EPC Input and Recent Technological Advancements

Direct air capture (DAC) technology has been developing at an accelerated rate. Independent, comprehensive, and transparent techno-economic analyses (TEAs) of DAC technologies are required to inform future development. NETL is publishing an update to the 2022 sorbent-based DAC case study report. This manuscript highlights select TEA results that will be presented in the upcoming NETL report. The analysis considers three sorbent-based DAC system configurations (direct steam temperature swing, indirect steam temperature swing, and direct steam temperature/vacuum swing) and two scenarios for providing the required electricity and steam (stand-alone system with a combined heat and power plant generating the required steam and electricity, and a purchased power case utilizing an electric boiler). Detailed sensitivity analyses are included and highlight the impact of external market factors, sorbent performance, and economies of scale. The potential for cost reductions by opting for temperature vacuum swing adsorption is highlighted. More detailed background and TEA results will be presented in the upcoming NETL report titled “Direct Air Capture Case Studies: Sorbent System (Revision 1)”.

carbon dioxide removal↗

Obsidian

Obsidian A35 is a compact FPGA carrier board designed to interface with ADCs, DACs or other devices, either stand-alone or as an I/O expansion board. The connectivity includes 1 GigE, 4 SFP, 6 PMOD, FTDI USB and Arduino shield compatible header. The board features also a FPGA boot SPI Flash, on-chip DDR3 memory, VCXO and White Rabbit compatibility.

Moore, Victoria [Lawrence Berkeley National Labora↗