Search NASA⌕ Search

DOE OSTI · 2473661

Passivated Contacts for Direct Wafer Product (Final Technical Report)

Abstract

This TCF project developed a thin-oxide (SiO 2 )/polycrystalline silicon (poly-Si) passivated contact solar cell on CubicPV's (formally 1366 Technologies, Inc.) Direct Wafer® Product (DWP) kerfless wafers. The project used two NREL-developed technologies described in U.S. Patent No. 9,911,873, Hydrogenation of Passivated Contacts and U.S. Patent Application Serial No. 15/890,172, Doped Passivated Contacts . The project was motivated by a potential higher efficiency cell (compared to a PERC cell) using passivated contacts on the ultra-low cost kerfless wafers grown using the Direct Wafer process. The hope was to accelerate market adoption of the cell and wafer by delivering the lowest LCOE in the PV industry. The project tested both n-type and p-type SiO 2 /poly-Si passivated contacts grown by thermal oxidation and plasma enhanced chemical vapor deposition (PECVD) of the poly-Si layer on DWP with varying wafer resistivities. Both deposition techniques are industry standards and thus economically viable methods for commercializing the contacts. The results indicated that both n-type and p-type poly-Si passivated contacts can be formed on polycrystalline DWP wafers, but implied open-circuit voltages (i Voc ) were limited to below 0.65 mV (compared with ~ 730 mV on n-Cz wafers). Diffusion of H to the Si/SiO 2 /poly-Si interface was key to obtaining high i Voc values. In this study, H was diffused from a high-temperature SiN x layer deposited over the poly-Si layer during a high-temperature firing step, similar to one used for screen printed metals. The study concluded that poly-Si passivated contacts on DWP wafers passivated the surface of the wafers as well as PERC passivated surfaces, which use a less expensive dielectric layer stack. The project showed that Direct Wafer Product wafers grown by CubicPV could produce high i Voc values (~0.647 mV), which could produce a cell over 20% efficient with proper processing and metallization. These cells, though not economically viable in 2024 as a stand-alone cell, could be integrated with a wide-bandgap top solar cell to form a two-junction tandem cell that could be viable under certain circumstances. This is because the bottom cell of a 30%, two-terminal tandem only needs to be a 20% cell under one-sun conditions. Thus, the DWP could be an ideal low-cost wafer for tandems. The project also revealed that a TOPCon type cell could be formed on a p-type DWP wafer using a P-diffused emitter and a p-type poly-Si contact. In fact, the p-type version of the poly-Si contact out-performed the n-type version for a variety of wafer resistivities, from highly doped to lowly doped. This curiosity requires more work to understand because on Cz wafers, the n-type poly-Si contact is of much higher quality than the p-type version.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Young, David L.. 2024-10-18. Passivated Contacts for Direct Wafer Product (Final Technical Report). https://doi.org/10.2172/2473661

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Heliostat sizing methodology for concentrating solar thermal industrial process heat projects

This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY↗