Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Storage system architectures and their characteristics

Not all users storage requirements call for 20 MBS data transfer rates, multi-tier file or data migration schemes, or even automated retrieval of data. The number of available storage solutions reflects the broad range of user requirements. It is foolish to think that any one solution can address the complete range of requirements. For users with simple off-line storage requirements, the cost and complexity of high end solutions would provide no advantage over a more simple solution. The correct answer is to match the requirements of a particular storage need to the various attributes of the available solutions. The goal of this paper is to introduce basic concepts of archiving and storage management in combination with the most common architectures and to provide some insight into how these concepts and architectures address various storage problems. The intent is to provide potential consumers of storage technology with a framework within which to begin the hunt for a solution which meets their particular needs. This paper is not intended to be an exhaustive study or to address all possible solutions or new technologies, but is intended to be a more practical treatment of todays storage system alternatives. Since most commercial storage systems today are built on Open Systems concepts, the majority of these solutions are hosted on the UNIX operating system. For this reason, some of the architectural issues discussed focus around specific UNIX architectural concepts. However, most of the architectures are operating system independent and the conclusions are applicable to such architectures on any operating system.

Sarandrea, Bryan M.↗

An emerging network storage management standard: Media error monitoring and reporting information (MEMRI) - to determine optical tape data integrity

Sophisticated network storage management applications are rapidly evolving to satisfy a market demand for highly reliable data storage systems with large data storage capacities and performance requirements. To preserve a high degree of data integrity, these applications must rely on intelligent data storage devices that can provide reliable indicators of data degradation. Error correction activity generally occurs within storage devices without notification to the host. Early indicators of degradation and media error monitoring 333 and reporting (MEMR) techniques implemented in data storage devices allow network storage management applications to notify system administrators of these events and to take appropriate corrective actions before catastrophic errors occur. Although MEMR techniques have been implemented in data storage devices for many years, until 1996 no MEMR standards existed. In 1996 the American National Standards Institute (ANSI) approved the only known (world-wide) industry standard specifying MEMR techniques to verify stored data on optical disks. This industry standard was developed under the auspices of the Association for Information and Image Management (AIIM). A recently formed AIIM Optical Tape Subcommittee initiated the development of another data integrity standard specifying a set of media error monitoring tools and media error monitoring information (MEMRI) to verify stored data on optical tape media. This paper discusses the need for intelligent storage devices that can provide data integrity metadata, the content of the existing data integrity standard for optical disks, and the content of the MEMRI standard being developed by the AIIM Optical Tape Subcommittee.

Podio, Fernando↗

Stand-alone digital data storage control system including user control interface

A storage control system includes an apparatus and method for user control of a storage interface to operate a storage medium to store data obtained by a real-time data acquisition system. Digital data received in serial format from the data acquisition system is first converted to a parallel format and then provided to the storage interface. The operation of the storage interface is controlled in accordance with instructions based on user control input from a user. Also, a user status output is displayed in accordance with storage data obtained from the storage interface. By allowing the user to control and monitor the operation of the storage interface, a stand-alone, user-controllable data storage system is provided for storing the digital data obtained by a real-time data acquisition system.

Wright, Kenneth D.↗

Analysis of Terrestrial Water Storage Changes from GRACE and GLDAS

Since March 2002, the Gravity Recovery and Climate Experiment (GRACE) has provided first estimates of land water storage variations by monitoring the time-variable component of Earth's gravity field. Here we characterize spatial-temporal variations in terrestrial water storage changes (TWSC) from GRACE and compare them to those simulated with the Global Land Data Assimilation System (GLDAS). Additionally, we use GLDAS simulations to infer how TWSC is partitioned into snow, canopy water and soil water components, and to understand how variations in the hydrologic fluxes act to enhance or dissipate the stores. Results quantify the range of GRACE-derived storage changes during the studied period and place them in the context of seasonal variations in global climate and hydrologic extremes including drought and flood, by impacting land memory processes. The role of the largest continental river basins as major locations for freshwater redistribution is highlighted. GRACE-based storage changes are in good agreement with those obtained from GLDAS simulations. Analysis of GLDAS-simulated TWSC illustrates several key characteristics of spatial and temporal land water storage variations. Global averages of TWSC were partitioned nearly equally between soil moisture and snow water equivalent, while zonal averages of TWSC revealed the importance of soil moisture storage at low latitudes and snow storage at high latitudes. Evapotranspiration plays a key role in dissipating globally averaged terrestrial water storage. Latitudinal averages showed how precipitation dominates TWSC variations in the tropics, evapotranspiration is most effective in the midlatitudes, and snowmelt runoff is a key dissipating flux at high latitudes. Results have implications for monitoring water storage response to climate variability and change, and for constraining land model hydrology simulations.

Syed, Tajdarul H.↗

Microgravity Storage Vessels and Conveying-Line Feeders for Cohesive Regolith

Under microgravity, the usual methods of placing granular solids into, or extracting them from, containers or storage vessels will not function. Alternative methods are required to provide a motive force to move the material. New configurations for microgravity regolith storage vessels that do not resemble terrestrial silos, hoppers, or tanks are proposed. The microgravity-compatible bulk-material storage vessels and exit feed configurations are designed to reliably empty and feed cohesive material to transfer vessels or conveying ducts or lines without gravity. A controllable motive force drives the cohesive material to the exit opening(s), and provides a reliable means to empty storage vessels and/or to feed microgravity conveying lines. The proposed designs will function equally well in vacuum, or inside of pressurized enclosures. Typical terrestrial granular solids handling and storage equipment will not function under microgravity, since almost all such equipment relies on gravity to at least move material to an exit location or to place it in the bottom of a container. Under microgravity, there effectively are no directions of up or down, and in order to effect movement of material, some other motive force must be applied to the material. The proposed storage vessels utilize dynamic centrifugal force to effect movement of regolith whenever material needs to be removed from the storage vessel. During simple storage, no dynamic motion or forces are required. The rotation rate during emptying can be controlled to ensure that material will move to the desired exit opening, even if the material is highly cohesive, or has acquired an electrostatic charge. The general concept of this Swirl Action Utilized for Centrifugal Ejection of Regolith (SAUCER) microgravity storage unit/dynamic feeder is to have an effective slot-hopper (based on the converging angles of the top and bottom conical section of the vessel) with an exit slot around the entire periphery of the SAUCER. The basic shape of such a unit is like two Chinese straw hats (douli) - one upside down, on the bottom, and another on top; or two wokpans, one upright on the bottom and another inverted on top, with a small gap between the upright and inverted pans or hats (around the periphery). A stationary outer ring, much like an unmounted bicycle tire, surrounds the gap between the two coaxial, nearly conical pieces, forming the top and bottom of the unit.

Walton, Otis R.↗

Long-Term, Non-Anthropogenic Groundwater Storage Changes Simulated by Three Global-Scale Hydrological Models

This study examined long-term, natural (i.e., excluding anthropogenic impacts) variability of groundwater storage worldwide. Groundwater storage changes were estimated by forcing three global-scale hydrological models with three 50+ year meteorological datasets. evaluation using in situ groundwater observations from the U.S. and terrestrial water storage derived from the Gravity Recovery and Climate experiment (GRACe) satellites showed that these models reasonably represented inter-annual variability of water storage, as indicated by correlations greater than 0.5 in most regions. Empirical orthogonal function analysis revealed influences of the El Niño Southern Oscillation (ENSO) on global groundwater storage. simulated groundwater storage, including its global average, exhibited trends generally consistent with that of precipitation. Global total (natural) groundwater storage decreased over the past 5–7 decades with modeled rates ranging from 0.01 to 2.18 mm year−1. this large range can be attributed in part to groundwater’s low frequency (inter-decadal) variability, which complicates identification of real long-term trends even within a 50+ year time series. Results indicate that non-anthropogenic variability in groundwater storage is substantial, making knowledge of it fundamental to quantifying direct human impacts on groundwater storage.

Bailing Li↗

Application of GRACE to the Estimation of Groundwater Storage Change in a Data-poor Region: A Case Study of Ngadda Catchment in the Lake Chad Basin

The present study is to explore the feasibility of GRACE-based estimation of a groundwater storage change in a data-poor region using a case study of the Ngadda catchment in the Lake Chad Basin. Although the Ngadda catchment has only one set of in situ time series data of groundwater from 2006 to 2009 and a limited number of groundwater measurements in 2005 and 2009, GRACE-based groundwater storage change can be evaluated against thein situ groundwater measurements combined with specific yield data. The cross-correlation analysis in the Ngadda catchment shows that maximum rainfall reached in July and August, whereas both the maximum total water storage anomaly and the maximum groundwater storage anomaly occurred 2months later. Whereas the mean annual amplitude of total water storage anomaly is about 17cm from both the average total water storage anomaly from three mascon products and the one from three spherical harmonic products, the mean annual amplitude of soil moisture storage anomaly is substantially varied from5.58cm for CLM to about 14cm for NOAH and Mosaic. The goodness-of-fit tests show that CLM soil moisture produces the closest estimation of groundwater storage anomaly to thein situ groundwater measurements. The present study shows that GRACE-based estimation for groundwater storage anomaly can be a cost-effective and alternative tool to observe how groundwater changes in a basin scale under the limitation of modelling and in situ data availability.

GRACE↗

Energy Efficient Large-Scale Storage of Liquid Hydrogen

The world’s largest liquid hydrogen storage tanks were constructed in the mid-1960sat the NASA Kennedy Space Center. These two vacuum-jacketed, perlite powder insulated tanks, still in service today, have 3,200 m3 of useable capacity. In 2018, construction began on an additional storage tank at Launch Complex 39B. This new tank will give an additional storage capacity of 4,700 m3 for a total on-site storage capacity of roughly 8,000 m3. NASA’s new Space Launch System (SLS) heavy lift rocket for the Artemis program includes an LH2tank that makes up the bulk of the vehicle, holding 2,033 m3 of LH2 in its 8.4-m diameter by40-m height. The new storage tank includes two new energy-efficient technologies: a glass bubbles insulation system in lieu of perlite, and an Integrated Refrigeration and Storage (IRAS)heat exchanger for controlled storage capability. The evacuated glass bubbles insulation system is based on the prior two decades of research to prove the thermal performance benefits as well as the mechanical and vacuum integrity; and has been shown to reduce LH2 boiloff by 46%versus perlite in field demonstrations. The IRAS capability is centered on a heat exchanger system that is built within the inner vessel to reject heat from the bulk liquid through the future implementation of an external helium refrigerator. Controlled storage via IRAS, when fully implemented, will provide full control of the ullage pressure, zero boiloff, and even production of densified LH2 pending its adoption on future launch vehicles. The design basics are described along with main construction and testing processes involved. The key features of the new technology items and implications on simplified operations and long-term energy savings are addressed

cryogenics↗

Economics of internal and external energy storage in solar power plant operation

A simple approach is formulated to investigate the effect of energy storage on the bus-bar electrical energy cost of solar thermal power plants. Economic analysis based on this approach does not require detailed definition of a specific storage system. A wide spectrum of storage system candidates ranging from hot water to superconducting magnets can be studied based on total investment and a rough knowledge of energy in and out efficiencies. Preliminary analysis indicates that internal energy storage (thermal) schemes offer better opportunities for energy cost reduction than external energy storage (nonthermal) schemes for solar applications. Based on data and assumptions used in JPL evaluation studies, differential energy costs due to storage are presented for a 100 MWe solar power plant by varying the energy capacity. The simple approach presented in this paper provides useful insight regarding the operation of energy storage in solar power plant applications, while also indicating a range of design parameters where storage can be cost effective.

Manvi, R.↗

Open systems storage platforms

The building blocks for an open storage system includes a system platform, a selection of storage devices and interfaces, system software, and storage applications CONVEX storage systems are based on the DS Series Data Server systems. These systems are a variant of the C3200 supercomputer with expanded I/O capabilities. These systems support a variety of medium and high speed interfaces to networks and peripherals. System software is provided in the form of ConvexOS, a POSIX compliant derivative of 4.3BSD UNIX. Storage applications include products such as UNITREE and EMASS. With the DS Series of storage systems, Convex has developed a set of products which provide open system solutions for storage management applications. The systems are highly modular, assembled from off the shelf components with industry standard interfaces. The C Series system architecture provides a stable base, with the performance and reliability of a general purpose platform. This combination of a proven system architecture with a variety of choices in peripherals and application software allows wide flexibility in configurations, and delivers the benefits of open systems to the mass storage world.

Collins, Kirby↗

Evolution of a high-performance storage system based on magnetic tape instrumentation recorders

In order to provide transparent access to data in network computing environments, high performance storage systems are getting smarter as well as faster. Magnetic tape instrumentation recorders contain an increasing amount of intelligence in the form of software and firmware that manages the processes of capturing input signals and data, putting them on media and then reproducing or playing them back. Such intelligence makes them better recorders, ideally suited for applications requiring the high-speed capture and playback of large streams of signals or data. In order to make recorders better storage systems, intelligence is also being added to provide appropriate computer and network interfaces along with services that enable them to interoperate with host computers or network client and server entities. Thus, recorders are evolving into high-performance storage systems that become an integral part of a shared information system. Data tape has embarked on a program with the Caltech sponsored Concurrent Supercomputer Consortium to develop a smart mass storage system. Working within the framework of the emerging IEEE Mass Storage System Reference Model, a high-performance storage system that works with the STX File Server to provide storage services for the Intel Touchstone Delta Supercomputer is being built. Our objective is to provide the required high storage capacity and transfer rate to support grand challenge applications, such as global climate modeling.

Peters, Bruce↗

Mass optical storage-tape (MOST)

In today's large mainframe and supercomputer environment there exists a continuous demand for increased performance in digital storage systems. The user need for near-line storage capacity is currently doubling every four years. In addition to higher capacity, a desire exists for higher data transfer rates, and longer term database archivability, at lower, and lower cost. Each component of this quartet of demands appears to be insatiable. Magnetic tape technology presently dominates the digital mass storage markets, but the continuous growth of requirements is drawing attention to the limitations of the technology as an archival mass storage medium. The lowest cost option currently available for long term data storage is to use magnetic tape, although it is not well suited to meeting the need for many tens of years of reliable storage. Today, the majority of magnetic tape mass storage systems are based on the IBM 3480/3490 (or compatible) tape drives. These drives offer only moderate transfer rates and relatively small increments of storage, both of which create a logistics problem due to the large numbers of cartridges necessary in a typical system and the time taken to transfer data. Both higher cartridge capacity and data transfer rates are available in some helical scan magnetic tape systems; however, these command a substantially higher price, exacerbating the cost problem, and are not compatible with most installed systems or tape databases.

Oakley, William S.↗

Ni-MH storage test and cycle life test

Gates Aerospace Batteries is conducting two long term test programs to fully characterize the NiMH cell technology for aerospace applications. The first program analyzes the effects of long term storage upon cell performance. The second program analyzes cycle life testing and preliminary production lot testing. This paper summarizes these approaches to testing the NiMH couple and culminates with initial storage and testing recommendations. Long term storage presents challenges to deter the adverse condition of capacity fade in NiMH cells. Elevated but stabilized pressures and elevated but stabilized end-of-charge voltages also appear to be a characteristic phenomenon of long term storage modes. However, the performance degradation is dependent upon specific characteristics of the metal-hydride alloy. To date, there is no objective evidence with which to recommend the proper method for storage and handling of NiMH cells upon shipment. This is particularly critical due to limited data points that indicate open circuit storage at room temperature for 60 to 90 days will result in irrecoverable capacity loss. Accordingly a test plan was developed to determine what method of mid-term to long-term storage will prevent irrecoverable capacity loss. The explicit assumption is that trickle charging at some rate above the self-discharge rate will prevent the irreversible chemical changes to the negative electrode that result in the irrecoverable capacity loss. Another premise is that lower storage temperatures, typically 0 C for aerospace customers, will impede any negative chemical reactions. Three different trickle charge rates are expected to yield a fairly flat response with respect to recoverable capacity versus baseline cells in two different modes of open circuit. Specific attributes monitored include: end-of-charge voltage, end-of-charge pressure, mid-point discharge voltage, capacity, and end-of-discharge pressure. Cycle life testing and preliminary production lot testing continue to dominate the overall technology development effort at GAB. The cell life test program reflects continuing improvements in baseline cell designs. Performance improvements include lower and more stable charge voltages and pressures. The continuing review of production lot testing assures conformance to the design criteria and expectations. This is especially critical during this period of transferring technology from research and development status to production.

Dell, R. Dan↗

Influence of technology on magnetic tape storage device characteristics

There are available today many data storage devices that serve the diverse application requirements of the consumer, professional entertainment, and computer data processing industries. Storage technologies include semiconductors, several varieties of optical disk, optical tape, magnetic disk, and many varieties of magnetic tape. In some cases, devices are developed with specific characteristics to meet specification requirements. In other cases, an existing storage device is modified and adapted to a different application. For magnetic tape storage devices, examples of the former case are 3480/3490 and QIC device types developed for the high end and low end segments of the data processing industry respectively, VHS, Beta, and 8 mm formats developed for consumer video applications, and D-1, D-2, D-3 formats developed for professional video applications. Examples of modified and adapted devices include 4 mm, 8 mm, 12.7 mm and 19 mm computer data storage devices derived from consumer and professional audio and video applications. With the conversion of the consumer and professional entertainment industries from analog to digital storage and signal processing, there have been increasing references to the 'convergence' of the computer data processing and entertainment industry technologies. There has yet to be seen, however, any evidence of convergence of data storage device types. There are several reasons for this. The diversity of application requirements results in varying degrees of importance for each of the tape storage characteristics.

Gniewek, John J.↗

Low-Pressure Long-Term Xenon Storage for Electric Propulsion

This Phase 2 effort demonstrated an alternative Xe storage and regulation system using activated carbon (AC) as a secondary storage media (ACSFR). This regulator system is nonmechanical, simple, inexpensive, and lighter. The ACSFR system isolates the thruster from the compressed gas tank, and allows independent multiple setpoint thruster operation. The flow using an ACSFR can also be throttled by applying increments in electrical power. Primary storage of Xe by AC is not superior to compressed gas storage with regard to weight, but AC storage can provide volume reduction, lower pressures in space, and potentially in situ Xe purification. With partial fill designs, a primary AC storage vessel for Xe could also eliminate problems with two-phase storage and regulate pressure. AC could also be utilized in long-term large quantity storage of Xe serving as a compact capture site for boil-off. Several Xe delivery ACSFR protocols between 2 and 45 sccm, and 15 min to 7 hr, were tested with an average flow variance of 1.2 percent, average power requirements of 5 W, and repeatability s of about 0.4 percent. Power requirements are affected by ACSFR bed sizing and flow rate/ duration design points, and these flow variances can be reduced by optimizing PID controller parameters.

Back, Dwight D.↗

Gas chromatographic column for the storage of sample profiles

The concept of a sample retention column that preserves the true time profile of an analyte of interest is studied. This storage system allows for the detection to be done at convenient times, as opposed to the nearly continuous monitoring that is required by other systems to preserve a sample time profile. The sample storage column is essentially a gas chromatography column, although its use is not the separation of sample components. The functions of the storage column are the selective isolation of the component of interest from the rest of the components present in the sample and the storage of this component as a function of time. Using octane as a test substance, the sample storage system was optimized with respect to such parameters as storage and readout temperature, flow rate through the storage column, column efficiency and storage time. A 3-h sample profile was collected and stored at 30 degrees C for 20 h. The profile was then retrieved, essentially intact, in 5 min at 130 degrees C.

NASA Program Exobiology↗

Linkages Between GRACE Water Storage, Hydrologic Extremes, and Climate Teleconnections in Major African Aquifers

Water resources management is a critical issue in Africa where many regions are subjected to sequential droughts and floods. The objective of our work was to assess spatiotemporal variability in water storage and related controls (climate, human intervention) in major African aquifers and consider approaches toward more sustainable development. Different approaches were used to track water storage, including GRACE/GRACE Follow On satellites for Total Water Storage (TWS); satellite altimetry for reservoir storage, MODIS satellites for vegetation indices, and limited ground-based monitoring. Results show that declining trends in TWS (60–73 km3 over the 18 yr GRACE record) were restricted to aquifers in northern Africa, controlled primarily by irrigation water use in the Nubian and NW Saharan aquifers. Rising TWS trends were found in aquifers in western Africa (23–49 km3), attributed to increased recharge from land use change and cropland expansion. Interannual variability dominated TWS variability in eastern and southern Africa, controlled primarily by climate extremes. Climate teleconnections, particularly El Nino Southern Oscillation and Indian Ocean Dipole, strongly controlled droughts and floods in eastern and southern Africa. Huge aquifer storage in northern Africa suggests that the recent decadal storage declines should not impact the regional aquifers but may affect local conditions. Increasing groundwater levels in western Africa will need to be managed because of locally rising groundwater flooding. More climate resilient water management can be accomplished in eastern and southern Africa by storing water from wet to dry climate cycles. Accessing the natural water storage provided by aquifers in Africa is the obvious way to manage the variability between droughts and floods.

Africa water storage↗

Spacecraft cryogenic gas storage systems

Cryogenic gas storage systems were developed for the liquid storage of oxygen, hydrogen, nitrogen, and helium. Cryogenic storage is attractive because of the high liquid density and low storage pressure of cryogens. This situation results in smaller container sizes, reduced container-strength levels, and lower tankage weights. The Gemini and Apollo spacecraft used cryogenic gas storage systems as standard spacecraft equipment. In addition to the Gemini and Apollo cryogenic gas storage systems, other systems were developed and tested in the course of advancing the state of the art. All of the cryogenic storage systems used, developed, and tested to date for manned-spacecraft applications are described.

Rysavy, G.↗