Search NASA⌕ Search

SEARCH · Search NASA

Results for “Strain Gauge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Strain gauge for testing microreactor hexagonal core blocks in the Single Primary Heat Extraction and Removal Emulator

To support the development and deployment of microreactor technologies, experiments that help verify and validate reactor systems and components are performed at non-nuclear test facilities. The Single Primary Heat Extraction Removal Emulator at Idaho National Laboratory is one of these test facilities and was used to monitor a test article that has a prototypic geometry of a heat-pipe cooled microreactor core block. To collect crucial temperature and strain data during testing, temperature and strain sensing fiber optics were embedded to the surface of the test article using an ultrasonic additive manufacturing technique. To support and provide benchmark strain data for the embedded sensors, a commercial resistive strain gauge was attached. This report will discuss the results from the deployment of the commercial strain gauge which includes the setup/attachment strategies, data acquisition, and analysis of the strain data.

36 MATERIALS SCIENCE↗

Two-Dimensional Laser-Speckle Surface-Strain Gauge

Extension of Yamaguchi's laser-speckle surface-strain-gauge method yields data on two-dimensional surface strains in times as short as fractions of second. Laser beams probe rough spot on surface of specimen before and after processing. Changes in speckle pattern of laser light reflected from spot indicative of changes in surface strains during processing. Used to monitor strains and changes in strains induced by hot-forming and subsequent cooling of steel.

Barranger, John P.↗

The Application of High-temperature Strain Gauges to the Measurements of Vibratory Stresses in Gas-turbine Buckets

The feasibility of measuring the vibration in the buckets of a gas turbine under service conditions of speed and temperature was determined by use of a high temperature wire strain gauge cemented to a modified supercharger turbine bucket. A high-temperature wire strain gauge and the auxiliary mechanical and electrical equipment developed for the investigation are described.

Kemp, R H↗

Strain Gauges Mounted To Retain Calibration

Silicon-based semiconductor strain gauges mounted in such way they retain original calibration for several years instead of few months. Improvement effected by bonding gauges to ceramic substrates with glasses instead of epoxies as adhesives.

Butler, Barry L.↗

Strain Gauge Diagnostic Development for use in Vessel Health Monitoring for Hydro-shots

Six-foot vessels are a crucial component to protecting high fidelity equipment at DARHT. Analysis shows these vessels have a limited life span (~10 shots) due to fatigue, ratcheting, and damage accumulation. Vessel health monitoring and diagnostics can help inform decision on a vessel’s fitness for service. Strain gauges are an easy and effective sensor for use in vessel health monitoring. In early March, J-2 executed a qualification shot, uniform blast loading with minimal fragments, with bi-axial strain gauges fielded at four locations around vessel. Several damage features were extracted from the data, and frequency content helps to validate computer modelling of the vessel response. Permanent plastic strain at each location was significant with location one having the most strain at the end state, with 230 micro-strain. However, residual pressure in the vessel could be a major factor in this strain. PEEQ is a measure of total plastic equivalent strain accumulation. The equivalent strain at location one exceeded the plastic strain limit four times and accumulated the most PEEQ with 2036 micro-strain. As expected, this qualification shot did contribute to damage in the vessel, and should be considered in its fitness for service, but not critical enough to pull it from service. Frequency content also gave valuable information on the modal response of the vessel and contributes to the understanding of how the vessel responds to the initial blast load with an expected lower frequency membrane/breathing mode and transitioning to higher frequency bending modes in the vessel wall.

42 ENGINEERING↗

An experimental evaluation of apparent strain from foil strain gauges attached to carbon composite substrates

An experimental evaluation of apparent thermal strains is conducted using various combinations of substrate/gauge/attachment structure and redundant high temperature extensometry. It is found that the extensometry could either confirm independent measurements of the substrate's thermal expansion, or quantify nonzero mechanical strains resulting from uncertain material behavior and boundary conditions. Apparent strain and thermal expansion behavior data can then be used to modify the raw strain measurements in order to determine either stress producing or total strains. Limitation of the correction procedure for the three selected strain gauges is noted which is due to relatively large gauge/attachment variability.

Scott, B. R.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method are of two types: foil and fiber-optic. Four foil gauges and one or more fiber-optic gauges are mounted on each of the tank-supporting legs. An additional fiber-optic gauge is mounted on an object, made of the same material as that of the tank-supporting legs, that is not subjected to any mechanical load. The reading obtained by the additional fiber-optic gauge is used to compensate for apparent strains caused by changes in temperature. The signals from the foil and fiber-optic gauges are conditioned, then digitized for input to a computer. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. At the time of reporting the information for this article, a set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 microstrain) that occurred during filling and emptying the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. It has been estimated that once the fiber-optic gauges are put into operation, it should be possible to determine fluid masses with 3 percent or less. It may be possible to increase accuracy further by increasing the signal-to-noise ratio through the use of more deformable tank supporting legs.

Figueroa, Jorge↗

The Lewis Strain Gauge Laboratory: Status and plans

An in-house lab was established for developing, testing, and evaluating high-temperature strain gauges and to aid in in-house applications of high-temperature strain instrumentation. The lab is automated to provide computer control of oven temperatures, imposed strain, and data sampling.

Hobart, Howard F.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗

Lithium-ion Battery Strain Gauge Monitoring and Depth of Discharge Estimation

Lithium-ion battery diagnostics and prognostics rely on measurements of electrical impedance, capacity, and voltage to infer the internal state of the battery. Mechanical changes to the cell structure represent an additional measure of the battery’s state because these changes are related to the overall battery health. As lithium-ion batteries are charged and discharged, lithium ions are inserted or removed from the anode and cathode, a process called intercalation and de-intercalation. As lithium ions intercalate and de-intercalate, they can cause changes to the lattice of the electrode particles, resulting in volumetric changes. These volumetric changes cause mechanical stresses and strains on the lithium-ion battery electrodes, and subsequently, the whole cell’s thickness varies as it is charged and discharged. This paper presents a study on the use of surface-mounted strain gauges for in-situ measurement of structural changes to lithium-ion batteries, along with a characterization of the unit-to-unit differences in strain response. A neural network modeling structure is then used to predict the battery’s depth of discharge under dynamic discharge conditions.

Lithium-ion batteries, depth of discharge, strain ↗

Protective Coats For High-Temperature Strain Gauges

Addition of some rare-earth oxides to prior alumina (only) coating material increases maximum service temperature of palladium/chromium-wire strain gauges. Pd/Cr wires used at temperatures up to 800 degrees C without excessive drift in electrical resistance. Oxides used: zirconia (ZrO2), yttria (Y2O3), ceria (CeO2), and hafnia (HfO2). Addition of one of these oxides to decrease oxidation of wire at high temperature. Protection against oxidation increases with concentration of rare-earth oxide. Addition of ZrO2 at 4 to 6 weight percent or Y2O3 at 1 weight percent results in smallest drift in electrical resistance.

Lei, Jih-Fen↗

Strain gauge ambiguity sensor for segmented mirror active optical system

A system is described to measure alignment between interfacing edges of mirror segments positioned to form a segmented mirror surface. It serves as a gauge having a bending beam with four piezoresistive elements coupled across the interfaces of the edges of adjacent mirror segments. The bending beam has a first position corresponding to alignment of the edges of adjacent mirror segments, and it is bendable from the first position in a direction and to a degree dependent upon the relative misalignment between the edges of adjacent mirror segments to correspondingly vary the resistance of the strain guage. A source of power and an amplifier are connected in circuit with the strain gauge whereby the output of the amplifier varies according to the misalignment of the edges of adjacent mirror segments.

Wyman, C. L.↗

Large Wire Strain Gauges

Wires yield data on average strains over distances ranging from inches to many feet. Long constantan wires used to measure average strains over distances characteristic of vehicles or buildings. Connected in bridge circuit, wires measure strain accurately within 1 percent, and linearly, within 0.1 percent. Wires stretch as much as 0.15 percent and still return to zero residual strain after release.

Bryner, B. D.↗

Increasing Durability of Flame-Sprayed Strain Gauges

Thermally sprayed dielectric ceramic coatings are the primary means of attaching strain and temperature gauges to hot-section rotating parts of turbine engines. As hot-section temperatures increase, lifetimes of installed gauges decrease, and seldom exceed one hour above 2,000 F (approx.1,100 C). Advanced engine components are expected to operate at temperatures approaching 2,200 F (approx.1,200 C), and the required high-temperature lifetime is 10 hours minimum. Typically, to enable a ceramic coating to adhere to the smooth surface of an engine component, a thermally sprayed NiCrAlY or NiCoCrAlY bond coat is applied to the smooth surface, thereby providing a textured surface to which the ceramic coat can adhere. The main failure mechanism of this system is decohesion and/or delamination at the interface between the ceramic top coat and the bond coat, caused by oxidation of the bond coat and stresses from the mismatch between the coefficients of thermal expansion of the ceramic top coat and the metallic bond coat. The approach taken to increase the high-temperature lifetime of a gauge attached to an engine component by the method described above involves (1) selective oxidation of the bond coat by means of a heat treatment in reduced oxygen partial pressure followed by (2) the application of a noble-metal diffusion barrier. In experiments to test this approach, heat treatments of NiCoCrAlY bond coats were carried out in a tube furnace in which, in each case, the temperature was alternately (1) increased at a rate of 3 C per minute and (2) held steady for one hour until the desired temperature was reached. The tube furnace was continuously purged with dry nitrogen gas. A final heat-treatment temperature range of 1,600 to 1,800 F (871 to 982 C) proved most beneficial.

Gregory, Otto J.↗

Tunneling Barrier-Integrated Gold Nanofilms for Negative Strain Gauging with Near-Zero Energy Consumption

Wireless strain sensors with minimal power needs are essential for long-term monitoring in energy-limited environments. We present a soft tunneling barrier-integrated gold thin film for negative strain sensing with near-zero energy consumption. The device features a strain-induced transition from an insulating to a metallic state, increasing conductivity by 9 orders of magnitude under a controlled strain. It consists of Au-PDMS-Au nanofilm layers, where the Au structures are near the percolation threshold and the PDMS layer acts as a tunneling barrier. Under strain, thinning due to the Poisson effect lowers the barrier’s potential height, enabling electron tunneling and forming an electrical path. Further, with a standby power consumption of ~10 –5 mW over 10 6 times lower than conventional sensors (~12.5 mW), this device is ideal for real-time, long-term stationary structural monitoring in multiple locations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗