Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Custom Unit Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, seal-less, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion, and restart capability under both ambient and vacuum conditions. The pump operated at 40 to 240 lbm/hr flow rate, 35 to 100 oF pump temperature, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test.

Schuller, Michael↗

Spectrally Efficient GaN High-Power Amplifier for Lunar Communications

The paper demonstrates a spectrally efficient Ka-band GaN MMIC based high-power amplifier (HPA) that uses a waveguide 4-port magic-tee as a 2-way power combiner to combine the output from two lower power amplifier circuits. The paper presents for the prototype HPA the measured output power, gain, power added efficiency, error vector magnitude for Offset-QPSK, 8PSK, 16APSK, 32APSK, and 16QAM waveforms, waveform spectrum, and out-of-band spectral regrowth. The HPA is intended for establishing a direct communication link between assets on the lunar surface/orbit and Earth.

Gallium nitride↗

Beam splitter used in dual filming technique

Tubular tee is intersected at its junction by a reflecting/transmitting mirror angled to provide two images of an object for simultaneous photographing from two positions. This method is used when space and focal conditions are limited.

Zeldin, S.↗

Shock-absorbing caster wheel is simple and compact

Compact shock-absorbing caster wheel mitigates or absorbs shock by a compressible tire which deforms into a cavity between its inner edge and the wheel hub. A tee-shaped annular ring embedded in the tire distributes loads more uniformly throughout both wheel and tire.

Kindley, R. J.↗

Liquid oxygen-compatible insulation system

To provide insulation for tees, elbows, sumps, and valves that are used to pass or store fluids at cryogenic temperatures, individual parts are insulated in an environmentally controlled facility. It is desirable that such insulation be liquid oxygen compatible and be easily removable and reinstallable.

Jones, J. S.↗

Effects of eccentricities and lateral pressure on the design of stiffened compression panels

An analysis for determining the effects of eccentricities and lateral pressure on the design of stiffened compression panels is presented. The four types of panel stiffeners considered are integral, zee, integral zee, and integral tee. Mass-strength curves, which give the mass of the panel necessary to carry a specified load, are given along with related design equations needed to calculate the cross-sectional dimensions of the minimum-mass-stiffened panel. The results of the study indicate that the proportions of the panels are geometrically similar to the proportions of panels designed for no eccentricity or lateral pressure, but no cross-sectional dimensions are greater, resulting in significantly increased mass. The analytical minimum-mass designs of zee-stiffened panels are compared with designs from experimentally derived charts. An assumed eccentricity of 0.001 times the length of the panel is used to correlate the analytical and experimental data. Good correlation between the experimentally derived and the analytical curves is obtained for the range of loading where materials yield governs the design. At lower loads the mass given by the analytical curve using this assumed eccentricity is greater than that given by the experimental results.

Giles, G. L.↗

Ultrasonic scanning system for inspection of brazed tube joints

An ultrasonic scanning system used to inspect and evaluate in-place brazed tube joints is considered. The system was designed, developed, and built especially for nondestructive testing and was selected because of its known response to brazing defects not associated with material density changes. The scan system is capable of scanning brazed joints in union, tee, elbow and cross configuration of 3/16-inch through 5/8-inch diameters. It is capable of detecting brazed defects as small as 0.008 by 0.010-inch, which exceeds the 0.015-inch diameter defect resolution required by specification.

Haynes, J. L.↗

Ultrasonic scanning system for in-place inspection of brazed tube joints

A miniaturized ultrasonic scanning system for nondestructive in-place, non-immersion testing of brazed joints in stainless-steel tubing is described. The system is capable of scanning brazed tube joints, with limited clearance access, in 1/4 through 5/8 inch union, tee, elbow and cross configurations. The system has the capability to detect defective conditions now associated with material density changes in addition to those which are depended upon density variations. The system includes a miniaturized scanning head assembly that fits around a tube joint and rotates the transducer around and down the joint in a continuous spiral motion. The C-scan recorder is similar in principle to conventional models except that it was specially designed to track the continuous spiral scan of the tube joint. The scanner and recorder can be operated with most commercially available ultrasonic flaw detectors.

Haynes, J. L.↗

Evaluation of coated columbium alloy heat shields for space shuttle thermal protection system application. Volume 3, phase 3: Full size TPS evaluation

The thermal protection system (TPS), designed for incorporation with space shuttle orbiter systems, consists of one primary heat shield thermally and structurally isolated from the test fixture by eight peripheral guard panels, all encompassing an area of approximately 12 sq ft. TPS components include tee-stiffened Cb 752/R-512E heat shields, bi-metallic support posts, panel retainers, and high temperature insulation blankets. The vehicle primary structure was simulated by a titanium skin, frames, and stiffeners. Test procedures, manufacturing processes, and methods of analysis are fully documented. For Vol. 1, see N72-30948; for Vol. 2, see N74-15660.

Baer, J. W.↗

High power ferrite microwave switch

A high power ferrite microwave switch was developed along with associated electronic driver circuits for operation in a spaceborne high power microwave transmitter in geostationary orbit. Three units were built and tested in a space environment to demonstrate conformance to the required performance characteristics. Each unit consisted of an input magic-tee hybrid, two non-reciprocal latching ferrite phase shifters, an out short-slot 3 db quadrature coupler, a dual driver electronic circuit, and input logic interface circuitry. The basic mode of operation of the high power ferrite microwave switch is identical to that of a four-port, differential phase shift, switchable circulator. By appropriately designing the phase shifters and electronic driver circuits to operate in the flux-transfer magnetization mode, power and temperature insensitive operation was achieved. A list of the realized characteristics of the developed units is given.

Bardash, I.↗

Shuttle LOX loading transient study. Task 2 milestone report. National space and technology laboratories (NSTL) LOX loading facility analysis

Transient thermodynamic analyses were made of the LOX loading system proposed for the space shuttle main propulsion test article (MPTA). This system is made up of a LOX replenish system and a main LOX line which include the barge tank, the lines, pumps, and valves between the barge and the orbiter (ORB) ground service equipment (GSE) interface, the MPTA fill system, the space shuttle main engine (SSME) chilldown bleed system, and the GSE vent system. System analyses include predictions of system performance sensitivity to operating sequence and LOX flowrate, temperature, and quality at the ORB/GSE interface. The transient thermodynamic conditions at the SSME feed line entrance, ET entrance (tank bottom), and the SSME bleed/GSE vent TEE are also included. The analyses are based on continuous SSME bleed flow during GSE facility chilldown.

Glasgow, V. L.↗

Observations of the quiet sun at meter and decameter wavelengths

The new TeePee Tee array of the Clark Lake Radio Observatory has been used to observe the quiet sun at 121.5, 73.8 and 26.3 MHz. The equatorial brightness distributions at all three frequencies, and the polar brightness distributions at the two higher ones have been measured. From the observed total fluxes and half-power diameters we have derived the peak brightness temperatures of the solar disk as well as of some sources of the slowly varying component.

Kundu, M. R.↗

Determination of the decameter wavelength spectrum of the quiet sun

The Teepee Tee array of the Clark Lake Radio Observatory has been used to compare the flux of the Sun with that of the sidereal sources Tau A and Vir A at several frequencies in the range 109.0-19.0 MHz. Only the two central banks of the E-W arm of the array were used as elements of a phase switched interferometer so that the Sun could be observed as a point source and compared directly to the sidereal sources. The Sun was still partially resolved however, and appropriate corrections for this effect were made. The observations were taken at times when the Sun and either Tau A or Vir A were at the same declination. We have therefore been able to derive the values for the solar flux, without having to resort to a gain vs zenith distance correction. The observations, combined with those available in the literature, allow us to derive an accurate meter and decameter wavelength spectrum of the quiet Sun.

Erickson, W. C.↗

Radio and white-light observations of the 1973 August 21 coronal transient

A coronal transient, which occurred on August 21, 1973, has been observed simultaneously in white light and at decameter radio wavelengths. The radio observations were obtained with a two-dimensional swept-frequency array (called the Teepee Tee). The white-light observations consist of a series of photographs taken by the High Altitude Observatory's coronagraph aboard Skylab. The radio emission associated with the transient was continuum in nature and lasted for almost 5 hours. The source of emission was observed to be cospatial with the lower part of one of the secondary white-light loops. A lower limit of 0.6 solar radius for the depth (extension along the line of sight) of this part of the transient was derived from considerations of radio-wave propagation in the corona. The radio source showed no dispersion of height with frequency, and, therefore, the emission is attributed to gyrosynchrotron radiation. Based on this assumption, the magnetic-field strength in the lower part of the loop is estimated to be in the 2.0-4.5-gauss range at a height of 2.1 solar radii from the center of the sun.

Gergely, T. E.↗

Optical digital techniques

Optical interface losses between transmitter-to-fiber interface, connector-to-connector interface, and fiber-to-receiver interface were studied. System effects such as pulse dispersion, risetimes of the sources and detectors, type of fibers used, output power of the sources, and detector sensitivity were considered. Data bus systems such as TEE, Star, and Hybrid were analyzed. The matter of single fiber versus bundle technologies for future avionics systems was considered. The existing data bus system on Space Shuttle was examined and an optical analog was derived for a fiber bundle system, along with the associated power margin. System tests were performed on a feasibility model of a 9-port Star data bus system including BER, star losses, connector losses, etc. The same system was subjected to EMI between the range of 200 Hz to 10 GHz at 20V/m levels. A lightning test was also performed which simulated the conditions similar to those on Space Shuttle. The data bus system was found to be EMI and lightning hard. It is concluded that an optical data bus system is feasible for shuttle orbiter type vehicles.

Source record↗

Multifrequency broadband polarized horn antenna

A corrugated conical horn antenna is simultaneously fed a multiplicity of signals, two for each of five frequencies, with each of a pair of signals fed in each of two orthogonal planes for excitation of a desired spherical hybrid mode. The lowest frequency is fed into the horn through orthogonal pairs of colinear slots, each pair being fed by coaxial tee power dividers. Other signals are fed through a circular waveguide connected to the vertex. The highest frequency signals are fed through orthogonal ports near the far end of the circular waveguide. The intermediate frequency signals are fed through orthogonal ports spaced along the waveguide. Filtering is incorporated for each to maintain isolation and low insertion loss.

Green, K. A.↗

Design considerations for high-power VHF radar transceivers: T/R switch design

The transceiver (TR) switch developed at NOAA's Aeronomy Laboratory for use in their 50 kW peak power, 50 MHz transmitter is described. The switch mounts inside the transmitter chassis and was designed to be compact while retaining the ability to handle well over 50 kW peak power at average power levels up to 2 kW. The TR switch is a conventional TR/ATR design with equivalent /4 transmission line sections constructed of lumped constant coils and transmitting capacitors in ''Tee' sections. Two TR sections are placed in series to achieve adequate receiver protection. The switch is set into the ''transmit' mode by forward biasing the 3 pin diodes to about 1.2 amperes each. The receive mode is achieved by back biasing the diodes to -15 volts. A directional coupler is also incorporated into the TR switch box to provide a convenient monitor point for forward and reflected transmitter power.

Ecklund, W. L.↗

Advanced Vapor-Supply Manifold

Advanced vapor-supply manifold solves problem of manifold purging. Design virtually eliminates dead gas volumes in manifold system. System incorporates special valve into manifold in way that leaks and contamination problems of previous systems, which use tees and three-port valves, are minimized or eliminated in both main manifold line and in supply line. Of considerable use in gas manifold systems where even small amounts of gaseous impurities constitute problem or where more than one gaseous material used in single system.

Clark, I. O.↗