Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Integration of Silica in G4CMP for Phonon Simulations: Framework and Tools for Material Integration

Superconducting detectors with sub-eV energy resolution have demonstrated success setting limits on Beyond the Standard Model (BSM) physics due to their unique sensitivity to low-energy events. G4CMP, a Geant4-based extension for condensed matter physics, provides a comprehensive toolkit for modeling phonon and charge dynamics in cryogenic materials. This paper introduces a technical formalism to support the superconducting qubit and low-threshold detector community in implementing phonon simulations in custom materials into the G4CMP. As a case study, we present the results of a detailed analysis of silica phonon transport properties relevant for simulating substrate backgrounds in Beryllium Electron capture in Superconducting Tunnel junctions (BeEST)-style experiments using G4CMP. Additionally, Python-based tools were developed to aid users in implementing their own materials and are available on the G4CMP repository.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Kinetic Inductance Phonon-Mediated Detectors for Dark Matter: R&D at NEXUS

Superconducting thin films have long been used as phonon sensors, particularly in the field of dark matter (DM) direct detection, due to the meV-scale Cooper-pair binding energy. A novel class of these detectors based on microwave kinetic inductance detectors, dubbed Kinetic Inductance Phonon-Mediated Detectors (KIPMDs), offers an attractive architecture for microcalorimeters to probe DM down to the fermionic thermal relic mass limit of a few keV. Such a device featuring an aluminum resonator patterned onto a silicon substrate was operated at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. With this device we have demonstrated a resolution on the energy absorbed by the superconductor of 2.5 eV, a factor of two better than current state-of-the-art. In this talk, I will present our measurement of the energy resolution and phonon collection efficiency performed by exposing the bare substrate to a pulsed source of 470 nm photons. I will also discuss the path forward to obtaining in these devices the sub-eV resolution required to test the “Freeze-in” class of DM models. Finally, I will review other complementary efforts in our group to develop a superconducting qubit-based low-threshold detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalar Co-SIMP dark matter: models and sensitivities

In this work, we present UV completions of the recently proposed number-changing Co-SIMP freeze-out mechanism. In contrast to the standard cannibalistic-type dark matter picture that occurs entirely in the dark sector, the 3 → 2 process setting the relic abundance in this case requires one Standard Model particle in the initial and final states. This prevents the dark sector from overheating and leads to rich experimental signatures. We generate the Co-SIMP interaction with a dark sector consisting of two scalars, with the mediator coupling to either nucleons or electrons. In either case, the dark matter candidate is naturally light : nucleophilic interactions favor the sub-GeV mass range and leptophilic interactions favor the sub-MeV mass range. Viable thermal models in these lighter mass regimes are particularly intriguing to study at this time, as new developments in low-threshold detector technologies will begin probing this region of parameter space. While particles in the sub-MeV regime can potentially impact light element formation and CMB decoupling, we show that a late-time phase transition opens up large fractions of parameter space. These thermal light dark matter models can instead be tested with dedicated experiments. We discuss the viable parameter space in each scenario in light of the current sensitivity of various experimental probes and projected future reach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the Thermal Properties of Ir/Pt Bilayer Transition Edge Sensors

In this work, we are developing a low-T c TES-based large-area and low-threshold detector targeting a variety of potential applications. The detector consists of a 50.8-mm-diameter Si wafer as the substrate and radiation absorber, a single Ir/Pt bilayer TES sensor in the center, and normal metal Au pads added to the TES to strengthen the TES–absorber thermal coupling. Tight TES–absorber thermal coupling improves detector sensitivity and response uniformity. Here, we report on the electron–phonon (e–ph) coupling strengths for the Ir/Pt bilayer and Au that are measured with our prototype detectors and TES devices. We found that a second weak thermal link besides the one due to e–ph coupling in Ir/Pt or Au was required to explain our data. With the effects of the second weak link accounted for, the extracted e–ph coupling constant Σ for Ir/Pt bilayer in the T c range between 32 and 70 mK is 1.9×10 8 WK -5 m -3 , and Σ’s for Au at 40 mK and 55 mK are 2.2×10 9 WK -5 m -3 and 3.2×10 9 WK -5 m -3 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Doped semiconductor devices for sub-MeV dark matter detection

Dopant atoms in semiconductors can be ionized with ∼ 10 meV energy depositions, allowing for the design of low-threshold detectors. We propose using doped semiconductor targets to search for sub-MeV dark matter scattering or sub-eV dark matter absorption on electrons. Currently unconstrained cross sections could be tested with a 1 g-day exposure in a doped detector with backgrounds at the level of existing pure semiconductor detectors, but improvements would be needed to probe the freeze-in target. We discuss the corresponding technological requirements and lay out a possible detector design. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Search by the SENSEI Experiment for Millicharged Particles Produced in the NuMI Beam

Millicharged particles appear in several extensions of the standard model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultrarelativistic millicharged particles produced in collisions of protons in the NuMI beam with a fixed graphite target. The absence of any ionization events with 3 to 6 electrons in the SENSEI data allow us to place world-leading constraints on millicharged particles for masses between 30 to 380 MeV. This work also demonstrates the potential of utilizing low-threshold detectors to investigate new particles in beam-dump experiments, and motivates a future experiment designed specifically for this purpose. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Security proof of practical quantum key distribution with detection-efficiency mismatch

Quantum key distribution (QKD) protocols with threshold detectors are driving high-performance QKD demonstrations. The corresponding security proofs usually assume that all physical detectors have the same detection efficiency. However, the efficiencies of the detectors used in practice might show a mismatch depending on the manufacturing and setup of these detectors. A mismatch can also be induced as the different spatial-temporal modes of an incoming signal might couple differently to a detector. Here we develop a method that allows to provide security proofs without the usual assumption. Our method can take the detection-efficiency mismatch into account without having to restrict the attack strategy of the adversary. Especially, we do not rely on any photon-number cutoff of incoming signals such that our security proof is directly applicable to practical situations. We illustrate our method for a receiver that is designed for polarization encoding and is sensitive to a number of spatial-temporal modes. In our detector model, the absence of quantum interference between any pair of spatial-temporal modes is assumed. For a QKD protocol with this detector model, we can perform a security proof with characterized efficiency mismatch and without photon-number cutoff assumption. Our method also shows that in the absence of efficiency mismatch in our detector model, the key rate increases if the loss due to detection inefficiency is assumed to be outside of the adversary's control, as compared to the view where for a security proof this loss is attributed to the action of the adversary.

97 MATHEMATICS AND COMPUTING↗

Charge-trap analysis in a SENSEI skipper-CCD: Understanding low-energy backgrounds in rare-event searches

Skipper charge-coupled devices (CCDs) are ultralow-threshold detectors capable of detecting energy deposits in silicon at the electronvolt scale. Skipper CCDs are increasingly used in rare-event searches, including experiments such as SENSEI, DAMIC-M, Oscura, and CONNIE, where one of the major challenges is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we use the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly, but more work is needed to assess the impact of the traps that cannot be characterized.

Brusco, Agustin↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the performance of cryogenic calorimeters with nonlinear multivariate noise cancellation algorithms

Abstract State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical interference or microphonics. The sources of this environmental noise can often be monitored by adding specially designed “auxiliary devices” (e.g. microphones, accelerometers, seismometers, magnetometers, and antennae). A model can then be constructed to predict the detector noise based on the auxiliary device information, which can then be subtracted from the true detector signal. Here, we present a multivariate noise cancellation algorithm which can be used in a variety of settings to improve the performance of detectors using multiple auxiliary devices. To validate this approach, we apply it to simulated data to remove noise due to electromagnetic interference and microphonic vibrations. We then employ the algorithm to a cryogenic light detector in the laboratory and show an improvement in the detector performance. Finally, we motivate the use of nonlinear terms to better model vibrational contributions to the noise in thermal detectors. We show a further improvement in the performance of a particular channel of the CUORE detector when using the nonlinear algorithm in combination with optimal filtering techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Superconducting Qubits for Dark Matter Detection

Developments over the last decade have pushed the search for particle dark matter (DM) to new frontiers, including the keV-scale lower mass limit for thermally-produced DM. Galactic DM at this mass is kinematically matched with the energy needed to break a Cooper pair in common superconductors (~meV). Quantum sensors such as superconducting qubits are sensitive to these broken Cooper pairs, and can potentially be exploited as low-threshold detectors for particle-like DM scattering. The Quantum Science Center group at Fermilab exploring the use of qubit-based detectors for particle detection in the LOUD surface dilution fridge facility. This talk will discuss recent R&D efforts to understand qubit response to energy depositions through a combination of measurements in LOUD and low-energy G4CMP simulations of our superconducting qubit chips.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic Platforms at Fermilab: Recent Results and Outlook

The Cosmic Quantum group at Fermilab operates three cryogenic facilities dedicated to the development and calibration of superconducting low-threshold detectors and qubits. One of which (LOUD) is located at the surface, while the other two (NEXUS and QUIET) are located 100 m underground enabling low-background device characterization and rare event searches. Recently, we have demonstrated world-leading resolution in the quasiparticle channel for kinetic inductance phonon-mediated detectors as well as the lowest rate of spatially- and temporally- correlated errors ( charge jumps ) in superconducting qubit chips. We have additionally made significant progress in expanding the suite of tools for simulating signal production and readout of these devices. In this talk, I will review these recent results, discuss some nascent projects focused on enhancing sensitivity of these detectors to sub-GeV dark matter, and highlight activities in these facilities over the next year.

Temples, Dylan J.↗

Digitally controlled pulse-level discriminator operates over wide voltage range

Low power drain discriminator circuit generates an output pulse when an input pulse exceeds a discrete digitally controlled threshold voltage. The discriminator operates over a wide linear or nonlinear range of threshold levels. It uses several amplifier stages ahead of a fixed-reference threshold detector.

Cancro, C. A.↗

Progress in the measurement of high-energy galactic cosmic ray electrons

Cosmic ray electron measurements by individual threshold detector elements show that about 30 percent of observed electron-like galactic cosmic showers are really proton initiated events. The cosmic electron spectrum at about 10 GeV exhibits a consistent dropoff in intensity leading to a best fit at a power law of spectral index -3.2; a break in the spectrum should occur above 10 GeV.

Silverberg, R. F.↗

Versatile logic system for use in nuclear experiments on scientific satellites.

An improved fast low-power-drain logic system has been developed for use in nuclear experiments on scientific satellites. The basic unit of the system is an AND-NAND gate which has a response in the 10-nsec range, a power drain of 2.0 mw and operates over the temperature range of -40 to +80 C. In addition to providing the AND-NAND logic functions, one or more of the basic units may be connected to yield a monostable pulse generator, a pulse generator proceeding an output pulse at the leading edge of the input pulse, a delay, a threshold detector, and a bistable circuit. The system requires relatively simple circuitry for interfacing at its outputs and inputs.

Cancro, C. A.↗

Optical pulse timing resolution

This correspondence evaluates the performance of the maximum likelihood (ML) and several suboptimal arrival time estimators for optical pulses. The performance analysis of a 'sliding window' counter followed by a threshold detector is achieved by deriving an expression for the first-crossing density of the output of the counter.

Lee, G.↗