Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technology Performance Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Thrifting iridium for hydrogen

Using renewable electricity to produce hydrogen fuel reduces reliance on fossil fuels. Proton exchange membrane water electrolyzers (PEMWEs) are the highest-performing commercialized technology. These devices split water into oxygen gas and hydrogen ions (protons) at the anode. The protons then migrate through an ion-conducting polymer membrane (ionomer) to be reduced to hydrogen gas at the cathode. Further, the anode reaction’s harsh environment requires the use of precious-metal catalysts, such as iridium oxide (IrO x ). Given the expense and scarcity, the design of electrodes that minimize the use of precious metals without compromising the requisite stability and activity is desired for large-scale hydrogen production. On page 791 of this issue, Shi et al. report that anchoring IrO x catalysts onto porous cerium-oxide (CeO x ) supports maintains performance even with much reduced precious metal use.

08 HYDROGEN↗

Design and testing of high-performance mini-channel graphite heat exchangers in thermoelectric energy recovery systems

Recent national energy usage studies by Lawrence Livermore National Laboratory in 2015 [1] show that there is approximately 59 Quads (1015 Btu’s) of waste thermal energy throughout various industrial, residential, power generation, and transportation sectors of the U.S. economy. Thermoelectric energy recovery is one important technology for recovering this waste thermal energy in high-temperature industrial, transportation and military energy systems. Thermoelectric generator (TEG) systems in these applications require high performance hot-side and cold-side heat exchangers to provide the critical temperature differential and transfer the required thermal energy. High performance hot-side heat exchangers in these systems are often metal-based due to requirements for high-temperature operation, strength at temperature, corrosion resistance, and chemical stability. However, the generally selected metal-based hot-side heat exchangers (i.e., Inconels, Stainless Steels) suffer from low thermal conductivity, high thermal expansion, and high density, which degrades their thermal performance, leads to high thermal-expansion-driven stresses, and creates relatively high mass/high volume (i.e., low power density) TEG systems that are then difficult to fabricate and integrate into viable energy recovery systems. This paper describes the design and testing of a new, high-temperature minichannel graphite heat exchanger designed for operation up to 500C that is a critical element of a high-power-density TEG power system for aircraft energy recovery. This high-performance graphite heat exchanger represents a new state-of-the-art standard in high-temperature heat exchangers for TEG systems, which provides higher thermal transport, less thermal expansion at operation, lower system level stresses on TE components, and a lighter weight TEG system. This new heat exchanger creates a new design paradigm in TEG system design for terrestrial energy recovery and potential NASA technology infusion into terrestrial energy system applications. This paper will present and discuss the key heat transfer, pressure drop, pumping power analyses and design tradeoffs that created this unique design. Heat transfer and pressure drop modeling was performed with both empirical models based on known heat transfer and friction factor correlations and COMSOL thermal/fluid dynamic modeling of the graphite heat exchanger structure. We will also discuss resulting thermal transport and heat fluxes predicted at the TEG interface level. Heat exchanger performance testing was performed under simulated operating conditions and correlation with test data at the anticipated operating temperature conditions will be presented and discussed.

Shevade, Abhijit↗

Gen 3 Particle Pilot Plant (G3P3) -- High-Temperature Particle System for Concentrating Solar Power (Phases 1 and 2)

The U.S. Department of Energy Solar Energy Technologies Office initiated the Generation 3 Concentrating Solar Power (CSP) program to achieve higher operating temperatures (>700 °C) to enable next-generation CSP high-temperature power cycles such as the supercritical CO 2 (sCO2) Brayton Cycle. Three teams were selected to pursue high-temperature gas, liquid, and solid pathways for the heat-transfer media. Phases 1 and 2, which lasted from 2018 – 2020, consisted of design, modeling, and testing activities to further de-risk each of the technologies and develop a design for construction, commissioning, and operation of a pilot-scale facility in Phase 3 (2021 – 2024). This report summarizes the activities in Phases 1 and 2 for the solid-particle pathway led by Sandia National Laboratories. In Phases 1 and 2, Sandia successfully de-risked key elements of the proposed Gen 3 Particle Pilot Plant (G3P3) by improving the design, operation, and performance of key particle component technologies including the receiver, storage bins, particle-to-sCO2 heat exchanger, particle lift, and data acquisition and controls. Modeling and testing of critical components have led to optimized designs that meet desired performance metrics. Detailed drawings, piping and instrumentation diagrams, and process flow diagrams were generated for the integrated system, and structural analyses of the assembled tower structure were performed to demonstrate compliance with relevant codes and standards. Instrumentation and control systems of key subsystems were also demonstrated. Together with Bridgers & Paxton, Bohannan Huston, and Sandia Facilities, we have completed a 100% G3P3 tower design package with stamped engineering drawings suitable for construction bid in Phase 3.

14 SOLAR ENERGY↗

Disambiguation of Isomeric Procyanidins with Cyclic B-Type and Non-cyclic A-Type Structures from Wine and Peanut Skin with HPLC-HDX-HRMS/MS

Hydrogen/deuterium exchange coupled with high-resolution mass spectrometry was successfully applied for the identification of A-type tetrameric, pentameric, and hexameric procyanidins in peanut skin. This extended a previous study on isomeric cyclic B-type unconventional tetramer, pentamer, and hexamer procyanidins found in wine and cranberries. Not only had the method successfully identified the procyanidins with a single A-linkage (e.g., tetrameric m/z 1153.2608) by means of distinguishing them from their isomeric cyclic B-type analogues, but this method also worked for procyanidins with two or more A-linkages (such as the tetrameric m/z 1151.2452). As a further consequence, B-type cyclic pentamers and hexamers in wine have been elucidated with hydrogen/deuterium exchange (HDX) for the first time. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the Effects of Anode Porous Transport Layer on the Performance and Durability of Anion Exchange Membrane Electrolyzers

As anion exchange membrane systems have emerged as a competitive low temperature electrolysis technology, research has expanded to other components and device integration. In this study, nickel (Ni) and stainless steel (SS)-based porous transport layers (PTLs) are investigated in membrane electrode assemblies (MEAs). Compared to MEAs using Ni, the SS PTL shows higher performance due to less kinetics and residual loss and possibly due to a combination of iron mobility improving oxygen evolution reactivity and electron conduction pathways, as well as higher porosity increasing site access. Voltage decay rates of approximately 144 and 115 μV/h, respectively, for the Ni and SS PTLs are found, although the long-term durability and lifetime implications are convoluted. Voltage breakdown analysis confirms that both PTLs saw significant increases in residual loss possibly due to catalyst/PTL property changes that affected electronic, ionic, and mass transport pathways. For the Ni PTL, a higher proportion of the losses were due to cell kinetics; comparatively, more of the SS PTL losses were due to increases in the high frequency resistance. The experimental findings presented here provide insights on the impact of the PTL materials and their properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid-State Thermodynamic Vent System for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellent condition. By exploiting the vacuum-induced cryocooling potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger expels some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. The primary STVS project objective was to design and build a bespoke STVS heat exchanger that employed aerogel blanket material and perform a ground demonstration of the technology using liquid nitrogen (LN2) as the cryogenic propellant. This demonstration aimed to prove that an STVS can have a positive influence on the tank boiloff, shown through a reduction in mass flow rate out of the system during operation, and exercise control over the tank pressure. Testing proved the effectiveness of the concept by reducing the LN2 boiloff rate and tank pressure by roughly 70% and 77% respectively during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Propellant Production↗

Nuclear code case development of printed-circuit heat exchangers with thermal and mechanical performance testing

The U.S. Department of Energy has agreed to fund a three-year integrated research project to close technical gaps involved with compact heat exchangers to be used in nuclear applications. This paper introduces the goals of the project, the research institutions, and industrial partners working in collaboration to develop a draft Boiler and Pressure Vessel Code Case for this technology. Heat exchanger testing, as well as non-destructive and destructive evaluation, will be performed by researchers across the country to understand the performance of compact heat exchangers. Testing will be performed using coolants and conditions proposed for Gen IV Reactor designs. Preliminary observations of the mechanical failure mechanisms of the heat exchangers using destructive and non-destructive methods is presented. Unit-cell finite element models assembled to help predict the mechanical behavior of these high-temperature components are discussed as well. Performance testing methodology is laid out in this paper along with preliminary modeling results, an introduction to x-ray and neutron inspection techniques, and results from a recent pressurization test of a printed-circuit heat exchanger. The operational and quality assurance knowledge gained from these models and validation tests will be useful to developers of supercritical CO 2 systems, which commonly employ printed-circuit heat exchangers.

42 ENGINEERING↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Performance Qualification Test of the ISS Water Processor Assembly (WPA) Expendables

The Water Processor Assembly (WPA) for use on the International Space Station (ISS) includes various technologies for the treatment of waste water. These technologies include filtration, ion exchange, adsorption, catalytic oxidation, and iodination. The WPA hardware implementing portions of these technologies, including the Particulate Filter, Multifiltration Bed, Ion Exchange Bed, and Microbial Check Valve, was recently qualified for chemical performance at the Marshall Space Flight Center. Waste water representing the quality of that produced on the ISS was generated by test subjects and processed by the WPA. Water quality analysis and instrumentation data was acquired throughout the test to monitor hardware performance. This paper documents operation of the test and the assessment of the hardware performance.

Carter, Layne↗

Structure of iridium oxide catalysts dictates performance differences for proton exchange membrane water electrolyzers

Proton exchange membrane water electrolyzers (PEMWEs) are promising zero-emission technologies. However, their high cost remains a barrier to widespread adoption. Iridium oxide is commonly used as an oxygen evolution reaction (OER) catalyst, and its cost and scarcity make it essential to reduce its loading while increasing its activity. Evaluation of iridium oxide activity should be carried out in the membrane electrode assembly (MEA) configuration to replicate realistic operating conditions. Herein, we present a comprehensive benchmarking framework to accurately evaluate the amorphous and crystalline iridium oxides at the MEA level. By systematically varying the catalyst loading, this study confirmed that each MEA was utilized uniformly, presenting intrinsic electrochemical properties independent of the loading. Through intrinsic charge density determined by voltammetry, we established two electrochemical descriptors to evaluate catalyst redox reactions. The mass activity was evaluated by correlating current vs. loading, and the slope provides loading-independent mass activity. The effect of the porous transport layer on OER activity was discussed, identifying a ‘background’ current at zero-loading. In conclusion, this study highlights potential pitfalls in MEA-level catalyst screening and underscores the importance of the loading study for reliable results.

Kwon, Obeen [University of California, Irvine, CA ↗

Falling-film heat exchangers used in desalination systems: A review

With growing demand for fresh water, there has been an increasing interest in energy-efficient desalination technologies. Falling-film-based, multi-effect distillation (MED) systems have been extensively deployed world-wide. The performance of such systems heavily depends on the efficiency of the evaporation process. Here, research on falling-film heat exchangers used in desalination systems, especially MED systems, is critically reviewed to assess the state of the technology. The review includes falling-film evaporation mechanisms, system operation, and scaling issues. Finally, opportunities for further application and areas where more research is needed are identified.

42 ENGINEERING↗

(Invited) Continuum Mathematical Modeling of Water Electrolysis: A Tutorial

Widespread use of hydrogen energy is contingent on the development of reliable and economical sources of hydrogen. Electrolysis from renewably-derived low-carbon electricity is a potentially viable method of hydrogen generation. Prime among the electrolysis technologies are those utilizing ion-conducting polymers (ionomers) including proton-exchange-membrane water electrolyzer (PEMWE). However, these technologies need to exhibit increased efficiency, performance, and durability to become commercially viable. Like most electrochemical devices, PEMWEs involve multiple components (e.g., catalyst, ionomer, transport layers, membrane, plates) and multiple phases, with phenomena occurring across different time and length scales. Furthermore, it is difficult to experimentally probe many of the species and phenomena during operation. Thus, mathematical modeling at the continuum level has been an invaluable aid in exploring, understanding, and optimizing PEMWE cell and components. Furthermore, this is especially true in the highly coupled and complex physics and chemistries that occur with the membrane-electrode assembly (MEA). The physics in a typical volume-averaged non-isothermal model include multiphase transport in porous media, concentrated-solution theory, Ohm's Law, and Butler-Volmer kinetics, and ion, gas, and water transport in the ionomer.

Dizon, Arthur↗

Fluidization of Group A Glass Particles: Experiments and Preliminary Validation

This work is aimed at providing reliable high-quality data from fluidization experiments. Geldart Group A glass beads are used as bed material. The fluidizing medium is air at atmospheric pressure which enters the system at 40% relative humidity. The air inlet velocity is varied over a broad range from 2 U mf to 26 U mf , where the minimum fluidization velocity, U mf , is 0.608 cm/s. There is not a significant change in the mean values of differential pressure; however, there are noticeable trends in their standard deviation values. Preliminary validation studies are performed using the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). The results from Eulerian-Eulerian (MFiX-TFM, two-fluid model) and Eulerian-Lagrangian (MFiX-PIC, particle-in-cell) formulations are compared. The work presented in this report highlights the applicability of MFiX-PIC for large-scale applications, and reveals that PIC simulation offers a suitable alternative to TFM simulation when effects due to multiple components or polydispersity are significant. PIC modeling provides a readily extendible framework for such systems. However, PIC models do rely on an empirical closure for inter-particle stress. Some solution discrepancies were evident in MFiX-PIC predictions which require further analysis. As such, the study underlines the need for a systematic approach to quantify the sources of numerical uncertainty within the PIC model. However, even with known empiricism, MFiX-PIC has demonstrated considerable potential in analyzing gas-solid systems. The results obtained are encouraging and warrant further investigation to improve the predictive capability of MFiX-PIC.

36 MATERIALS SCIENCE↗

Safety Basis Development for the Tank Closure Cesium Removal (TCCR) Demonstration - 19596

The Tank Closure Cesium Removal (TCCR) system has been installed at Savannah River Site (SRS) to supplement the existing salt waste treatment facilities. The TCCR system is intended to demonstrate the capability of ion exchange (IX) technology to remove Cs-137 from high level liquid waste. Separation is performed by Crystalline Silicotitanate (CST) IX media. The media is stored in shielded columns within a small enclosure. Following processing in the TCCR system, decontaminated waste can receive further treatment and be dispositioned at other SRS facilities. The Cesium-laden columns will instead be removed from the enclosure and transported to another location on site for interim storage. Developing the safety basis for the TCCR system and integrating it into the documented safety analysis for existing facilities presented a unique challenge. Most notably, utilizing new methodologies to analyze new hazards resulted in unexpectedly high consequences. The TCCR system therefore required more rigorous controls than had initially been anticipated. However, the integrated control set developed for the TCCR system should have little impact on its operating capabilities and will allow it to begin operating in 2019. This may lay the foundations for future utilization of similar systems at SRS and across the Department of Energy complex. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the origin of permanent performance loss of anion exchange membrane fuel cells: Electrochemical oxidation of phenyl group

The durability of alkaline anion exchange membrane fuel cells (AEMFCs) is a critical requirement for implementing this technology in cost-effective energy conversion. However, the lifetime of current AEMFCs is short, ca. < 1,000 h and the cause of the performance loss over time is poorly understood. Here, we investigate the origin of AEMFC unrecoverable performance loss. We diagnosed the recoverable performance loss induced by carbonation and anode flooding during an extended-term test with transient operating conditions. Multiple extended-term tests under current densities and the electrochemical and analytical analyses suggest that the most prominent permanent performance loss of AEMFCs occurs by phenol formation as a result of electrochemical phenyl oxidation of cathode ionomeric binder. The produced phenol is acidic and neutralizes the quaternary ammonium group to lower the local pH. Finally, the impact of this degradation pathway is discussed to explain the reported lifetime performance of current AEMFCs.

08 HYDROGEN↗

Hybrid power plant design for low-carbon hydrogen in the United States

In this study, we provide a nationwide techno-economic analysis of clean hydrogen production powered by a hybrid renewable energy plant for over 50,000 locations in the United States. We leverage the open-source Hybrid Optimization Performance Platform (HOPP) tool to simulate the hourly performance of an off-grid wind-solar plant integrated with a 1-GW polymer exchange membrane electrolyzer system. The levelized cost of hydrogen is calculated for varying technology costs, and tax credits to explore cost sensitivities independent of plant design, performance, and site selection. Our findings suggest that strategies for cost reduction include selecting sites with abundant wind resources, complementary wind and solar resources, and optimizing the sizing of wind and solar assets to maximize the hybrid plant capacity factor. These strategies are linked to increased hydrogen production and reduced electrolyzer stack replacements, thereby lowering the overall cost of hydrogen.

08 HYDROGEN↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications – Acquire Nortek Residential AC/HP Units for Evaluation and Model the Units Using HPDM

For the upcoming refrigerant transition from HFCs to minorly flammable HFO refrigerants (A2L), refrigerant charge reduction is important to mitigate the fire hazard. Microchannel heat exchangers (MHXs) are a mature technology, which is effective in reducing system charge while maintaining similar heat transfer performance. MHXs will be applied more widely when the new refrigerants are used. Prior studies of the A2L HFO blends were mostly focused on fin-and-tube coils (FTC). An in-depth study for an air conditioner (AC)/heat pump (HP) system using all microchannel heat exchangers is still lacking. In FY19, a side-to-side comparison will be conducted between two residential split heat pumps, one using all FTCs and the other using all MHXs for drop-in investigation, to identify potential issues for future design. The two heat pumps have similar rated capacity, SEER, HSPF levels, similar fan, blower and compressor, but differ in heat exchangers. Both the HPs use two-stage compressors to facilitate investigating different refrigerant flow rates. We will drop-in HFO refrigerants (replacements for R-410A, e.g. R452B, R447B, R32, etc.). The experiments will reveal the potential of MHXs for charge reduction, and how the two systems using A2L refrigerants operate under standard SEER and HSPF rating conditions. The two units were donated by our partner, i.e. Nortek Global HVAC, an industry leader in making heat pumps using all MHXs as well as FTCs. The units were shipped to ORNL this week, and the product design data were also shared for modeling the two units using HPDM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stable, high-performing bifunctional electrodes for anion exchange membrane-based unitized regenerative fuel cells

Anion exchange membrane unitized regenerative fuel cells (AEM-URFCs) are a promising technology for energy storage and electricity production; however, their efficiency is limited by the kinetics of the bifunctional oxygen electrode (BOE) where the oxygen evolution reaction (OER) and oxygen reduction reaction (ORR) occur. A particular concern when designing the BOE is that the OER and ORR have differing catalytic requirements, which make it challenging to develop effective bifunctional electrocatalysts with single active sites. In this study, we focus on advancing the BOE performance using Pt-IrO x and Pt-NiCoO x electrocatalysts. Here, single-layer and dual-layer Pt-IrO x BOEs were made, with the dual-layer electrode leading to improved performance due to efficient catalyst utilization in both modes. Using the dual-layer oxygen electrode paired with a PtRu/C hydrogen electrode, a round trip efficiency (RTE) as high as 50% (62 %iR-free) was achieved at 500 mA/cm 2 and operation for more than 24 h, which included five one-hour-long H 2 generation and consumption cycles followed by one eight-hour-long cycle. To the best of our knowledge, this is the highest performance for AEM-URFCs reported to date. Lastly, the approach is extended to electrodes with a Pt loading of 0.5 mg/cm 2 and the IrO x substituted by NiCoO x .

25 ENERGY STORAGE↗