Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermocouple”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

TRUST Sensors in Environments: Thermocouples (SE-TC) Report Release FY24

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. This work uses and provides feedback on analysis tools and experimental results databases for efficient and responsive engineering which are currently under development.

42 ENGINEERING↗

Removing Rotational Variations from Shoulder Thermocouples in Friction Stir Welding

Thick plate and lower temperature friction stir welding results in good post-weld properties by welding at very low tool rotational speeds. Low speeds cause large variations in the measured shoulder temperature, making temperature control difficult. This paper describes a computationally light method to correct for oscillating measured temperatures. Data is collected over the previous two revolutions and used to build a compensation table and calculate a derivative. In simulation, measured temperature variations are reduced by a factor of five to ten. Temperature data is preserved and not cornered, nor is any time delay induced by this method, unlike with filtering methods.

Friction Stir Welding, Temperature↗

Embedding Sensors in 3D Printed Metal Structures

The Transformational Challenge Reactor (TCR) program is leveraging recent advances in modeling and simulation, materials, and additive manufacturing (AM) technologies to design a modern nuclear reactor. Some of the main TCR technologies include in situ monitoring and the integration of sensors during the manufacturing of quality-significant nuclear reactor components. This report describes the general procedure and process optimization for embedding sensors within generic stainless steel 316 (SS316) components using laser powder bed fusion (LPBF). A more detailed, quality-significant test plan and supporting procedures are available upon request (ORNL/TM-2021/2127). LPBF involves the use of a scanning laser to selectively melt regions of a powder bed, additively building a part layer by layer. This report describes the LPBF processing technique and discusses the effects of LPBF processing parameters on the success of the sensor embedding process. Experiments used machined cavities in the form of channels in an SS316 base for the sensors to lay in while material is additively built over the top, thereby embedding them in an SS316 matrix. A preliminary investigation involved using empty SS316 sheaths as surrogates to explore the effects of various LPBF processing parameters and the dimensional requirements of the machined channels. Microstructural investigations showed that a smaller channel width/depth combination closer to the sensor’s diameter was best for the embedding process. After the desired parameters were selected, Type-K thermocouples were embedded and evaluated post-embedding using nondestructive thermal testing, as well as destructive sectioning and microscopy. Post-build characterization showed that the thermocouples were well-bonded to the SS316 matrix and were fully functional after embedding. During thermal testing to temperatures up to 500 °C, the embedded thermocouples read consistently with one another and deviated only slightly from the readings of a nonembedded thermocouple located within the furnace. This slight discrepancy was most likely due to differences in the thermal time constants for a nonembedded thermocouple vs. a thermocouple embedded in a solid SS316 block. The results presented in this report will serve as the foundation for future work that will focus on embedding sensors in relevant TCR reactor components and eventually testing those components under neutron irradiation.

36 MATERIALS SCIENCE↗

Retractable Sensor for Reactor Experiments

This presentation is to orient a mechanical or nuclear engineering senior design team so that they can help solve an instrumentation problem found in high power test reactors. Test reactors such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory are used to irradiate nuclear fuels and materials to evaluate performance after high levels of exposure to a reactor in-pile environment. The purpose of the experiments is to determine property changes as the materials or fuels are bombarded with fast neutrons (and thermal (slow) neutrons as well). Typically, the irradiation must take place at a very specific temperature. Sometimes other parameters are monitored as well as properties such as creep, or gas composition, etc. However, the fast neutrons cause changes in not only the materials, but also in the transducers that are placed in the neutron flux, e.g., thermocouples or optical fibers. This task will be limited to considering temperature measurements. Thermocouples experience decalibration from not only the neutron flux, but also from the very high temperatures that are sometimes measured. Optical fibers darken in a neutron or gamma flux. However, it takes quite a few hours, or days for these changes to manifest. High power test reactors typically run at a constant power and so the temperature in an experiment is fairly stable over time. Because the changes are typically very slow, even a single temperature measurement per day, would provide 95% of a perfect data set. The basic concept of this effort is to push a very small diameter thermocouple or optical fiber into the location to be measured, leave it for 30 seconds or so for it to come to equilibrium, and transmit the signal, and then pull it up and away from the high neutron flux and high temperature region. The distance the thermocouple or fiber would need to move is on the order of 50 – 100 cm. By doing this, the thermocouple junction or optical fiber would spend only a few hours in the high flux/high temperature environment over the life of the irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cylindricity Sensitivity Thermal Model of the AGR-5/6/7 Experiment in the Advanced Test Reactor

The AGR-5/6/7 experiment is currently being irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory and is approximately 70% complete. Several fuel and material irradiation experiments have been planned for the U.S. Department of Energy Advanced Gas Reactor Fuel Development and Qualification Program, which supports the development and qualification of tristructural isotropic (TRISO) coated particle fuel for use in high-temperature gas-cooled reactors. The goals of these experiments are to provide irradiation performance data to support fuel process development, qualify fuel for normal operating conditions, support development of fuel performance models and codes, and provide irradiated fuel and materials for post-irradiation examination and safety testing. Originally planned and named as separate fuel experiments, but subsequently combined into a single test train, AGR-5/6/7 is testing low-enriched uranium oxycarbide TRISO fuel. The AGR-5/6/7 test train has 5 capsules with thermocouples and independent gas control mixtures. Unique to this paper is a sensitivity study concerning the cylindricity of the graphite holders containing the fuel compacts and their eccentricity in relation to the stainless-steel capsule walls. Each capsule has small nubs on the outside used for centering the graphite holder inside the stainless-steel capsule with a small gas gap used to control temperature. Due to machining tolerances of these nubs and vibration wearing the nubs down when the experiment is running in the reactor, the possibility exists that the holder may move around radially. Each capsule is equipped with several thermocouples placed at various radii and depths within each graphite holder. This paper will show the sensitivity of offsetting the graphite holder for various radii in 45-degree increments around the circle with the objective of minimizing the difference between the measured thermocouples and the modeled thermocouple temperatures. Separate gas mixtures of helium/neon are introduced into this gas gap between the holder and capsule wall and changed as necessary to maintain the desired thermocouple temperatures to keep the fuel compacts at constant temperature as the nuclear reactor conditions change. The goal of the sensitivity study is to find a radius and an angle to offset the holder from perfectly centered for each of the five capsules separately. The complex thermal model includes fission heating, gamma heating, radiation heat transfer, and heat transfer via conduction and radiation across the control gaps. Subroutines linked to the thermal model offer an easy method to offset the graphite holder from the capsule walls without remeshing the entire model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High temperature thick film sensor development based on doped lanthanum chromites refractory semiconductors materials

High temperature advanced sensing materials have generated high demand due the high accuracy temperature measurements requirements for process optimization, controlling and sensing. Some technological applications of harsh conditions sensing include monitoring tiles of space shuttles, rotating bearings in aircraft engines, turbines, jet engines dynamics and chemical reactors. High temperature conditions limit the sensing strategies, where typically traditional metal thermocouples are unstable, and the sensing options are limited to optical spectroscopy methods. Recently, refractory semiconductors thick- and thin-film thermocouples have been developed and, in many cases, preferred over conventional metallic thermocouples due their spatial resolution, and capability of direct deposition on any surface. Rare earth chromites ceramics materials, exhibit some properties of interest for high temperature sensing technologies development, such as: high microstructure and sintering stability, excellent conductive behavior at high temperatures, and matching thermal expansion coefficients relative to other conductors and refractory ceramics. In this work, high performance ultra-high temperature thermocouples using p-type and n-type doped lanthanum chromites materials were fabricated and tested at temperatures up to 1500 o C. Thermoelectric voltage, Seebeck Coefficients were established for all devices, evidencing high stability and performance in prolongated operational time and harsh conditions.

20 FOSSIL-FUELED POWER PLANTS↗

Smart Refractory Sensors Development for Corrosion and Erosion Monitoring in High Temperature Systems

To optimize the operation and functioning of high temperature systems such as slagging gasifiers, coal boilers and glass/steel melters, it is important to monitor corrosion and erosion of refractory used in such systems. Corrosion test strategies are generally based on continuous gravimetric and chemical reactivity monitoring at operational temperatures (750°-1500°C). Both thermocouples and failure sensors and arrays would be useful to monitor the health of any refractory or coatings in these systems. Many of such type of sensors are installed into the systems through open access ports within the refractory; however, there are some disadvantages of this approach where corrosive/erosive gas and molten materials can penetrate and compromise the system. The current work presents the development and performance demonstration of smart refractory with embedded high temperature sensors such as thermocouples, thermistors, and various spallation/crack monitoring sensors, which may be used within a variety of refractory brick in different high temperature processes and applications. The main feature of this technology is that electroceramic based sensors are embedded into smart refractory without significantly impact to the intrinsic properties of the refractory. This technology circumvents the need to insert an isolated monolithic, stand-alone sensor into the refractory via an access port. This technological approach guarantees the integrity and the chemical stability of the materials used in the sensor fabrication within the harsh environment and does not introduce molten material (such as slag) penetration pathways within the refractory. One interesting and important aspect of this innovation is that these embedded sensors can be used to in situ monitoring processes such as chemical reactions and at the same time give information and a deeper understanding of the corrosion and erosion process of the refractory within the system. As stated above, the objective of our work is to develop high-temperature sensors composed of electroceramic materials that are chemically stable at high temperatures (750°-1500°C) and high pressures (up to 1000 psi) that can be used in monitoring corrosion and erosion process in refractory used in high energy systems. The high-temperature sensors investigated in this work were composed of various oxide composites directly embedded into the refractory oxides. The composites used for this work were synthesized by a mixed-oxide route. Metal oxides were inserted within a matrix material composed of refractory oxides (Al2O3, ZrO2, etc.). The physical and electrical properties were specifically manipulated by altering the level of percolation of the conductive species (metal oxides) within the refractory constituent (refractory oxide). Prior to the development of the high-temperature sensors, the oxides composites developed in this study were sintered up to 1600°C under oxidizing atmosphere in order to investigate densification, microstructural evolution, phase development, and their thermoelectrical performance as a function of the composition. The 4-point DC conductivity measurements were performed between 100°-1500°C. The sensors were fabricated from the composite materials by 3D-printing or screen-printing methods into the refractory brick during the consolidation process. An example of one of these embedded sensors consisted of an electroceramic-based thermocouple fabricated with two separate oxide composite compositions which were patterned to produce a couple within the interior of a refractory matrix. The thermocouple successfully displayed thermoelectric voltage trend (as a function of temperature), and the voltage was 220.0 mV around 1400 °C. Corrosion tests on the refractory embedded sensors were performed. To evaluate corrosion in the refractory brick an in-house glass composition was prepared and pressed into pellets and delivered into a pre-cut cavity in the brick. Corrosion experiments results showed the glass penetrated the brick over a 90 h period, and the penetration of the glass through the brick could be monitored by both an amperometric and voltametric based sensor. With this experiment, it was demonstrated that the embedded sensor could dynamically monitor the corrosion process.

20 FOSSIL-FUELED POWER PLANTS↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxide Semiconductor Sensors for Monitoring Advanced Energy Conversion and Manufacturing Processes at High Temperature

To optimize the operation and functionality of high temperature systems such as slagging gasifiers, coal boilers and glass/steel smelters, it is important to monitor temperature, corrosion and erosion of the refractory used in such systems. Both thermocouple and failure sensors (and arrays of these) would be useful to monitor the health of any refractory or coatings in these systems. Many of such type of sensors are installed into the systems through open access ports within the refractory; however, there are some disadvantages of this approach where corrosive/erosive gas and molten materials can penetrate and compromise the system. The current work presents the development and performance of refractory with embedded high temperature sensors such as thermocouples, thermistors, and various spallation/crack monitoring sensors, which may be used within a variety of refractory brick in different high temperature processes and applications. The objective of our work is to develop high-temperature sensors composed of electroceramic materials that are chemically stable at high temperatures (750°-1500°C) and high pressures (up to 1000 psi) that can be used in monitoring temperature, corrosion and erosion process in refractory used in high energy systems. The high-temperature sensors investigated in this work were composed of various oxide composites directly embedded into the refractory oxides. The composites used for this work were synthesized by a mixed-oxide route. Metal oxides were inserted within a matrix material composed of refractory oxides (Al2O3, ZrO2, etc.). The physical and electrical properties were specifically manipulated by altering the level of percolation of the conductive species (metal oxides) within the refractory constituent (refractory oxide). An example of one of these embedded sensors consisted of an electroceramic-based thermocouple fabricated with two separate oxide composite compositions which were patterned to produce a couple within the interior of a refractory matrix. The thermocouple successfully displayed thermoelectric voltage trend (as a function of temperature), and the voltage was 220.0 mV near 1400 °C. In addition, corrosion tests on the refractory embedded sensors were performed. To evaluate corrosion in the refractory was exposed to high-temperature glass compositions over a 90 h period. The penetration of the glass through the refractory could be monitored by both an amperometric and voltametric based sensor. With this experiment, it was demonstrated that the embedded sensor could dynamically monitor the corrosion process, and thus, provide real-time feedback on both temperature and the refractory health.

20 FOSSIL-FUELED POWER PLANTS↗

HBU R and D Cask Transportation Options - 20436

The TN-32B HBU Demonstration Cask was successfully loaded in November 2017 with 32 high burnup (HBU) fuel assemblies at Dominion's North Anna Nuclear Plant and is collecting thermal data as intended. The first two phases of this very successful project sponsored by DOE and EPRI was designed to collect thermal data of HBU fuel to support extended storage. The next phase of the project requires the cask be licensed for transportation so the cask can be relocated to a site (to be determined by DOE) to facilitate long term monitoring and additional research on the fuel. This is a unique challenge given the constraints that exist for this particular bolted metal cask. The TN-32B cask is a 234,288 lb. (storage configuration) dry storage system that was selected for this project and it was modified to provide thermal data and the ability to collect gas samples after loading. Several major issues must be addressed to obtain the transport license including protecting the seven lid penetrations that were made to allow for the insertion of the thermocouples into the selected fuel assemblies after the cask was loaded. In order to protect the integrity of the research, the payload must remain as is. Therefore, the cask system must be placed into the transportation configuration without rewetting the fuel, replacing the lid and without removing the thermocouple instrumentation that is currently installed. A critical portion of the design and engineering that was performed in the first two phases of the project was to ensure that future transportation of the cask was integrated into the approach. Efforts were made to accommodate requirements such as containment boundary leakage testing, installation of impact limiter brackets and lid bolts suitable for transportation. Due to the science requirements of the project, the fuel selected was intended to yield the highest payload temperatures permitted to provide the greatest value for the researchers. This resulted in higher than usual external dose rates and surface temperatures that warranted performing as much preparatory work prior to cask loading to ensure ALARA and personnel safety to the greatest extent practical rather than working on a loaded cask. In addition to the work performed prior to cask load, there are remaining challenges such as protecting the modified lid, design and fabrication of impact limiters that accommodate the modified cask lid and preserving the thermocouple connections for continued monitoring. The project team is currently performing the necessary calculations, engineering, and design to support the licensing as required by the US NRC. Pre-application meetings have been held to inform the regulator of the planned technical approach to ensure compliance with the applicable regulations. The current plan is to obtain the transportation C of C by the end of 2021. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Considerations for the temperature stratification in a pre-burn constant-volume combustion chamber

In recent years, the Engine Combustion Network (ECN) has developed as a worldwide reference for understanding and describing engine combustion processes, successfully bringing together experimental and numerical efforts. Since experiments and numerical simulations both target the same boundary conditions, an accurate characterization of the stratified environment that is inevitably present in experimental facilities is required. The difference between the core-, and pressure-derived bulk-temperature of pre-burn combustion vessels has been addressed in various previous publications. Additionally, thermocouple measurements have provided initial data on the boundary layer close to the injector nozzle, showing a transition to reduced ambient temperatures. The conditions at the start of fuel injection influence physicochemical properties of a fuel spray, including near nozzle mixing, heat release computations, and combustion parameters. To address the temperature stratification in more detail, thermocouple measurements at larger distances from the spray axis have been conducted. Both the temperature field prior to the pre-combustion event that preconditions the high-temperature, high-pressure ambient, as well as the stratification at the moment of fuel injection were studied. To reveal the cold boundary layer near the injector with a better spatial resolution, Rayleigh scattering experiments and thermocouple measurements at various distances close to the nozzle have been carried out. The impact of the boundary layers and temperature stratification are illustrated and quantified using numerical simulations at Spray A conditions. Next to a reference simulation with a uniform temperature field, six different stratified temperature distributions have been generated. These distributions were based on the mean experimental temperature superimposed by a randomized variance, again derived from the experiments. The results showed that an asymmetric flame structure arises in the computed results when the temperature stratification input is used. In these predictions, first-stage ignition is advanced by 24 $\mu$s , while second-stage ignition is delayed by 11 $\mu$s. At the same time a lift-off length difference between the top and the bottom of up to 1.1 mm is observed. Furthermore, the lift-off length is less stable over time. Given the shown dependency, the temperature data is made available along with the vessel geometry data as a recommended basis for future numerical simulations.

42 ENGINEERING↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

Validation of 266 nm UV Raman thermometry using the alpha-to-beta quartz transition

Ultraviolet Raman scattering is a promising diagnostic for temperature measurements relevant to dynamic compression experiments, where improved signal strength and reduced background are critical. In this work, we experimentally validate Raman thermometry at 266 nm using crystalline quartz heated through the α to β phase transition in a tube furnace. Quartz provides a useful benchmark because of its well-characterized transition temperature near 846 K at ambient pressure. Temperatures inferred from the Stokes to anti-Stokes intensity ratio are compared with thermocouple measurements and with the observed phase transition. Single-shot Raman temperatures track the thermocouple closely, with an empirical single-shot scatter of approximately ±15 K under the present conditions. Temporal averaging reduces shot-to-shot scatter and improves agreement between the Raman temperatures and thermocouple readings to within approximately 8 K, while the transition is identified within 5 K of the accepted value. Measurements are performed using the fourth harmonic of a nanosecond pulsed Nd:YAG laser at 266 nm. The shorter excitation wavelength provides enhanced Raman scattering efficiency and reduced visible background relative to conventional visible excitation. Comparison with 532 nm Raman measurements acquired in the same experimental geometry demonstrates substantially improved signal-to-noise ratio for the UV configuration. These results establish 266 nm Raman thermometry as a reliable and accurate temperature diagnostic under controlled heating conditions and provide a quantitative benchmark for future application in dynamic compression and shock physics experiments.

Chemistry - Chemical explosives↗