Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transmission electron microscopy (TEM)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Chemical and bonding analysis of liquids using liquid cell electron microscopy

Liquid cell transmission electron microscopy (TEM) has become an essential tool for studying the structure and properties of both hard and soft condensed-matter samples, as well as liquids themselves. Liquid cell sample holders, often consisting of two thin window layers separating the liquid sample from the high vacuum of the microscope column, have been designed to control in situ conditions, including temperature, voltage/current, or flow through the window region. While high-resolution and time-resolved TEM imaging probes the structure, shape, and dynamics of liquid cell samples, information about the chemical composition and spatially resolved bonding is often difficult to obtain due to the liquid thickness, the window layers, the holder configuration, or beam-induced radiolysis. Here, we review different approaches to quantitative liquid cell electron microscopy, including recent developments to perform energy-dispersive x-ray and electron energy-loss spectroscopy experiments on samples in a liquid environment or the liquid itself. We also cover graphene liquid cells and other ultrathin window layer holders.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

INR-TEM: Robust cavity detection in multifocus TEM images via implicit neural representations

When characterizing materials using transmission electron microscopy (TEM) images, detecting and quantifying small features in microstructures, such as cavities, pose significant challenges. Off-the-shelf object detection models, including YOLOv8, show considerable performance degradation, particularly when images vary in resolution and the objects of interest possess a low percentage of the total image region of interest. In this study, we introduce a novel detection pipeline that incorporates an implicit neural representation (INR)-based detection method, INR-TEM, and two-modality imaging (e.g., under-focused and over-focused images typically acquired during materials characterization) to improve object detection performance. The INR-TEM method incorporates a pixel-wise prediction principle inspired by pixel-wise centerness weighting. INR-TEM demonstrates superior robustness to resolution variability, maintaining high detection accuracy even at low image resolutions compared to YOLOv8. To leverage INR-TEM effectively in real-world two-modality characterization applications, we further integrate a two-stage motion correction pipeline designed explicitly for aligning multifocus TEM images. The alignment process, comprising keypoint (based on scale-invariant feature transform, SIFT) and intensity matching, significantly mitigates the adverse effects of perceived motion-induced image degradation during through-focal TEM imaging, directly enhancing INR-TEM’s detection capability over conventional single-focus images. Our integrated INR-TEM cavity detection framework notably improves performance across various cavity sizes, outperforming off-the-shelf YOLOv8 detections that rely on a single image modality.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation induced amorphization of carbides in additively manufactured and conventional ferritic-martensitic steels: In-situ experiments on extraction replicas

In-situ irradiations using 1 MeV Kr 2+ ions in a transmission electron microscope were performed on extraction replica samples containing M 23 C 6 carbides and MX carbonitrides from two ferritic-martensitic (FM) steels: (i) 9%Cr-1%W-TaV based Eurofer97 and (ii) 9%Cr-1%Mo-VNb (all in wt.%) based additively manufactured (AM) Grade91 steel. The irradiations were performed between 100 and 773 K up to a maximum dose of ~2.4 displacements per atom (dpa). The M 23 C 6 carbides are highly susceptible to radiation induced amorphization (RIA), while the MX type nanoprecipitates are highly amorphization resistant across the entire irradiation temperature range. Between 100 and 423 K, RIA of M 23 C 6 carbides occurs very rapidly with critical amorphization doses ranging between ~0.35 and 0.9 dpa, increasing to higher doses at 573 K. Complete amorphization of the M 23 C 6 carbides up to doses of ~2.4 dpa is not possible at 773 K under the present irradiation conditions. The critical amorphization dose of M 23 C 6 carbides increases nearly exponentially with irradiation temperature. The critical temperature for the crystalline-to-amorphous phase transformation (T c→a ) of M 23 C 6 carbides irradiated as replica samples, i.e. without the surrounding metal matrix, was estimated to be ~812 K. Comparing the present results with neutron irradiation data on bulk samples reveals a decrease in the critical amorphization dose for M 23 C 6 and an increase of T c→a , highlighting the effect of dose rate on the amorphization behavior that is qualitatively consistent with literature on other non-metals. Changes in the minor chemistry of M 23 C 6 , such as presence or absence of W, V, Nb, Mo, seems to have little effect on the amorphization behavior. Here, in-situ irradiations on extraction replica samples provide a novel pathway to explore radiation tolerance of nanoprecipitates in nuclear structural materials

36 MATERIALS SCIENCE↗

In Situ Study of Resistive Switching in a Nitride‐Based Memristive Device

Abstract Resistive switching (RS) devices with ultra‐low‐voltage threshold and reliable switching repeatability exhibits great potential applications in energy‐efficient data storage and neuromorphic computing. Understanding switching mechanisms at nanoscale is critical to design RS devices with improved performance. In this work, a lamella memristive device using focused ion beam (FIB) method based on the metal/TiO x /TiN/Si structure device is fabricated. In situ transmission electron microscopy (TEM) and current–voltage ( I–V ) characteristic demonstrate that the lamella device shows a volatile RS behavior with a threshold switching at ≈ ± 0.4 V. In situ scanning transmission electron microscopy (STEM) experiments with electron energy loss spectroscopy (EELS) reveal that the charge carriers such as oxygen vacancies migrate under positive/negative DC bias and modulate Schottky barriers at the top and bottom metal/semiconductor interfaces. The RS mechanism of the lamella device is based on the Schottky barriers modulation and Joule heating assisted electric field triggered thermal runaway (FTTR) occurred at the metal/semiconductor interfaces. The fundamental insights gained from this study presents a perspective on interface‐type RS devices processing and opens up new technological opportunities of fabricating ultra‐low‐energy memristive devices.

36 MATERIALS SCIENCE↗

DefectTrack: a deep learning-based multi-object tracking algorithm for quantitative defect analysis of in-situ TEM videos in real-time

Abstract In-situ irradiation transmission electron microscopy (TEM) offers unique insights into the millisecond-timescale post-cascade process, such as the lifetime and thermal stability of defect clusters, vital to the mechanistic understanding of irradiation damage in nuclear materials. Converting in-situ irradiation TEM video data into meaningful information on defect cluster dynamic properties (e.g., lifetime) has become the major technical bottleneck. Here, we present a solution called the DefectTrack , the first dedicated deep learning-based one-shot multi-object tracking (MOT) model capable of tracking cascade-induced defect clusters in in-situ TEM videos in real-time. DefectTrack has achieved a Multi-Object Tracking Accuracy (MOTA) of 66.43% and a Mostly Tracked (MT) of 67.81% on the test set, which are comparable to state-of-the-art MOT algorithms. We discuss the MOT framework, model selection, training, and evaluation strategies for in-situ TEM applications. Further, we compare the DefectTrack with four human experts in quantifying defect cluster lifetime distributions using statistical tests and discuss the relationship between the material science domain metrics and MOT metrics. Our statistical evaluations on the defect lifetime distribution suggest that the DefectTrack outperforms human experts in accuracy and speed.

42 ENGINEERING↗

Hybrid nanocapsules for in situ TEM imaging of gas evolution reactions in confined liquids

Liquid cell transmission electron microscopy (TEM) enables the direct observation of dynamic physical and chemical processes in liquids at the nanoscale. Quantitative investigations into reactions with fast kinetics and/or multiple reagents will benefit from further advances in liquid cell design that facilitate rapid in situ mixing and precise control over reagent volumes and concentrations. This work reports the development of inorganic–organic nanocapsules for high-resolution TEM imaging of nanoscale reactions in liquids with well-defined zeptoliter volumes. These hybrid nanocapsules, with 48 nm average diameter, consist of a thin layer of gold coating a lipid vesicle. As a model reaction, the nucleation, growth, and diffusion of nanobubbles generated by the radiolysis of water is investigated inside the nanocapsules. When the nanobubbles are sufficiently small (10–25 nm diameter), they are mobile in the nanocapsules, but their movement deviates from Brownian motion, which may result from geometric confinement by the nanocapsules. Gases and fluids can be transported between two nanocapsules when they fuse, demonstrating in situ mixing without using complex microfluidic schemes. The ability to synthesize nanocapsules with controlled sizes and to monitor dynamics simultaneously inside multiple nanocapsules provides opportunities to investigate nanoscale processes such as single nanoparticle synthesis in confined volumes and biological processes such as biomineralization and membrane dynamics.

36 MATERIALS SCIENCE↗

Strategies to overcome electron-beam issues in liquid phase TEM: Study of chemical processes

Abstract Liquid phase (or liquid cell) transmission electron microscopy (TEM) has become a powerful platform for in situ investigation of various chemical processes at the nanometer or atomic level. The electron beam for imaging can also induce perturbation to the chemical processes. Thus, it has been a concern that the observed phenomena in a liquid cell could deviate from the real-world processes. Strategies have been developed to overcome the electron-beam-induced issues. This article provides an overview of the electron-beam effects, and discusses various strategies in liquid cell TEM study of nucleation, growth, and self-assembly of nanoscale materials, where an electron beam is often used to initiate the reactions, and highly electron-beam-sensitive electrochemical reactions. Graphical abstract

Zheng, Wenjing↗

Argon Milling of Bulk and Post-FIB Specimens for Multi-Length Scale Analyses by EBSD, TEM, and APT under Controlled Environments

Correlative investigations involve structural characterization by transmission electron microscopy (TEM) combined with compositional analysis by atom probe tomography (APT) using the same specimen. A critical component of successful correlative analyses is specimen preparation; probing individual atoms requires a surface and subsurface with minimal defects, beginning with the bulk material through to the prepared specimen for TEM or APT analysis. Our previous work showed that low-energy concentrated ion beam Ar ion milling improves TEM [1] and APT [2,3] specimen quality by removing surface oxides and Ga damage caused by focused ion beam (FIB) preparation. Further enhancement in specimen quality of APT specimens is achieved in the established workflow under controlled environments, as shown in [4]. In this work, we present specimen preparation using Ar ion milling techniques not only for the APT specimen, but also the bulk sample for subsequent multi-length scale analyses by electron backscatter diffraction (EBSD), TEM, and APT under controlled environments. The removal of surface damage and oxidation, which is crucial for probing atomic layer specimens by broad and concentrated Ar ion beam milling techniques under controlled environments, is highlighted.

36 MATERIALS SCIENCE↗

Ultra-Microtome for the Preparation of TEM Samples from Battery Cathodes

An ultra-microtome method is developed for the preparation of transmission electron microscopy (TEM) specimens from the cathodes of Li-ion battery. Results indicate that the samples prepared with the ultra-microtome method yield atomic resolution imaging from the core area of particles of hundreds to thousands of nanometers. Analysis of the TEM samples prepared with ultra-microtome indicates that no observable structural damage, such as microcracking, is introduced during the cutting process, and the cathodes cut by ultra-microtome exhibit unchanged micro-morphologies compared with the uncut ones. These results demonstrate that ultra-microtome is a promising method for the preparation of TEM specimens and revealing in-depth microstructures of fragile materials such as battery cathodes.

transmission electron microscopy, Sample Preparati↗

Atomic Resolution Imaging of Light Elements in a Crystalline Environment using Dynamic Hollow-Cone Illumination Transmission Electron Microscopy

Multiple electron scattering and the nonintuitive nature of image formation with coherent radiation complicate the interpretation of conventional transmission electron microscopy images. Precession of the illuminating beam in transmission electron microscopy (TEM) can lead to more robust and interpretable images with some penalty to image contrast, a technique known as dynamic hollow-cone illumination TEM. Here, we demonstrate direct and robust imaging of light and heavy atoms in a crystalline environment with this technique. This method is similar to the annular bright-field technique in scanning transmission electron microscopy, via the principle of reciprocity. Dynamic hollow-cone illumination TEM is challenging in practice due to sensitivity to the misalignment of the precession axis, microscope objective aperture, and crystal zone axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural and Mechanical Analysis of Individual Mineralized Collagen Fibrils Using In Situ Transmission Electron Microscopy

Bone serves as an example of nature’s architectured material with its characteristic blend of strength and toughness, all at a lightweight design. Given the hierarchical nature of these materials, it is essential to understand the governing mechanisms and organization of their constituents across length scales for bioinspired structural design. Despite recent advances in transmission electron microscopy (TEM) that have allowed us to witness the hierarchical arrangement of bone at micro-down to the nanoscale, we are still missing the details about the structural organization and mechanical properties of the main building blocks of bone─mineralized collagen fibrils (MCFs). Here, we present a method to extract individual MCFs from nature’s model material, mineralized turkey leg tendon, using a dropcasting procedure. By isolating the MCFs onto TEM supporting grids, we visualized the arrangement of organic and mineral phases within individual MCFs at the nanoscale. Using a four-dimensional scanning transmission electron microscopy (4D-STEM) approach, the orientation of individual mineral crystals within the MCFs was examined. Furthermore, we conducted in situ tensile experiments, revealing exceptional tensile strains of at least 8%, demonstrating the intricate relationship between structural organization and the mechanical behavior of MCFs. These insights into the ultrastructure of mineralized tissue building blocks, as well as the proposed sample-extraction method compatible with in situ mechanical testing, provide a strong basis for research into nature-inspired material design.

4D-STEM↗

The effects of vanadium substitution on one-dimensional tunnel structures of cryptomelane: Combined TEM and DFT study

Rational design of energy storage materials requires mechanistic understanding which relies on atomic scale characterization of structure and defects. In this paper we utilize vanadium (V)-substituted one-dimensional cryptomelane as a model material to study structural features critical to electrochemical reversibility of the cathode in lithium-ion batteries. We found the substitution of manganese (Mn) atoms in the tunnel wall with V enhances structural uniformity in the parent KMn 8 O 16 material by inhibiting formation of irregular (2 × 3 and 2 × 1) manganese oxide tunnel structures. Upon lithiation, both transmission electron microscopy (TEM) and density functional theory (DFT) reveal significant structural evolution, eventually resulting in phase separation and formation of highly reduced manganese oxide. During this process, Mn 4+ accepts electrons donated by intercalated Li, while the V 4+ substituent is not electrochemically reduced but acts to stabilize the tunnel framework structure. As a result, the V substituted material shows higher operating voltage and improved electrochemical reversibility. Our results highlight the benefits of V-substitution in cryptomelane, and the significance of integrating characterization with simulation for understanding and developing design principles for lithium ion battery materials.

25 ENERGY STORAGE↗

In situ electron microscopy: atomic-scale dynamics of metal oxidation and corrosion

Corrosion degrades metals through complex microscopic processes that traditional methods often fail to capture. In-situ transmission electron microscopy (TEM) bridges this gap by providing real-time atomic-scale imaging of oxidation and corrosion dynamics. Gas-phase TEM uncovers critical oxidation mechanisms like oxide nucleation and alloying effects, while liquid-phase TEM tracks corrosion initiation. Coupled with emerging techniques like ultrafast direct electron detection cameras, these advancements promise unprecedented resolution in understanding material degradation.

36 MATERIALS SCIENCE↗

Direct Observations of Field-Intensity-Dependent Dielectric Breakdown Mechanisms in TiO 2 Single Nanocrystals

One of the main challenges for next-generation electric power systems and electronics is to avoid premature dielectric breakdown in insulators and capacitors and to ensure reliable operations at higher electric fields and higher efficiencies. However, dielectric breakdown is a complex phenomenon and often involves many different processes simultaneously. Here we show distinctly different defect-related and intrinsic breakdown processes by studying individual, single crystalline TiO 2 nanoparticles using in-situ transmission electron microscopy (TEM). As the applied electric field intensity rises, rutile-to-anatase phase transition, local amorphization/melting, or ablation are identified as the corresponding breakdown processes, the field intensity thresholds of which are found to be related to the position of the intensified field and the duration of the applied bias relative to the time of charged defects accumulation. Our observations reveal an intensity-dependent dielectric response of crystalline oxides at breakdown and suggest possible routes to suppress the iniation of premature dielectric breakdown. Hence, they will aid the design and development of next generation robust and efficient solid dielectrics.

36 MATERIALS SCIENCE↗

Facile Tensile Testing Platform for In Situ Transmission Electron Microscopy of Nanomaterials

In situ tensile testing using transmission electron microscopy (TEM) is a powerful technique to probe structure-property relationships of materials at the atomic scale. In this work, a facile tensile testing platform for in situ characterization of materials inside a transmission electron microscope is demonstrated. The platform consists of: 1) a commercially available, flexible, electron-transparent substrate (e.g., TEM grid) integrated with a conventional tensile testing holder, and 2) a finite element simulation providing quantification of specimen-applied strain. The flexible substrate (carbon support film of the TEM grid) mitigates strain concentrations usually found in free-standing films and enables in situ straining experiments to be performed on materials that cannot undergo localized thinning or focused ion beam lift-out. The finite element simulation enables direct correlation of holder displacement with sample strain, providing upper and lower bounds of expected strain across the substrate. The tensile testing platform is validated for three disparate material systems: sputtered gold-palladium, few-layer transferred tungsten disulfide, and electrodeposited lithium, by measuring lattice strain from experimentally recorded electron diffraction data. The results show good agreement between experiment and simulation, providing confidence in the ability to transfer strain from holder to sample and relate TEM crystal structural observations with material mechanical properties.

2D materials↗

In Situ High-Temperature TEM Observation of Inconel Corrosion by Molten Chloride Salts with N 2 , O 2 , or H 2 O

Here, in situ transmission electron microscopy (TEM) diffraction and imaging techniques are used to monitor and quantify corrosion of Inconel-625 by pure molten chloride salts (MgCl 2 – NaCl – KCl) at 500 °C–800 °C in 1.0 atm inert N 2 or pure O2, or by salts which are controllably hydrated in a high vacuum chamber. The isothermal corrosion rate R in inert N 2 increases from 203 ± 30 μ m year –1 at 700 °C to 463 ± 30 μ m year –1 at 800 °C. An oxygen ambient causes a six-fold increase to R = 1261 ± 170 μ m year –1 at 700 °C. Salt hydration dramatically accelerates corrosion to R > 3 × 10 5 μ m year –1 at 700 °C while it leads to a more moderate R = 95 ± 20 and 486 ± 30 μ m year –1 at 500 °C and 600 °C, respectively. These isothermal corrosion rates indicate that the molten chloride corrosion is significantly accelerated by salt hydration at temperatures above 600 °C, where corrosion is aggravated by increased generation and solubility of corrosive HCl gases. Hence, to reduce rate of corrosion it is important to both avoid incorporation of H 2 O into the system at each stage and ensure proper flushing of the system before increasing the temperature beyond 600 °C. Compositional analysis of the corroded cells indicate that corrosion in O 2 ambient is dominated by oxidation of metals by O 2 gas dissolved in the chloride melt, but corrosion in H 2 O ambients is caused by chlorination of metals by dissolved HCl gas and MgOH + ions. So, to reduce rate of corrosion, steps should be taken to tailor chloride melt compositions that has low solubility for HCl and O 2 . All of our corroded samples exhibit passive-protective oxide layers of Cr, Mg, and Ni. In addition, distinct volatile compounds of Ni, Mo and Cr involving NiCl 2 , (Na,K) 2 MoO 4 and CrO 2 (OH) 2 are detected in N 2 , H 2 O, and O 2 ambients, respectively. We believe that corrosion acceleration can be minimized by minimizing formation of volatile by-products or promoting reactions that could convert these volatile compounds to solid phases, as these volatile compounds led to destruction of protective oxide layers.

14 SOLAR ENERGY↗

Deep Learning Segmentation of Complex Features in Atomic-Resolution Phase-Contrast Transmission Electron Microscopy Images

Phase-contrast transmission electron microscopy (TEM) is a powerful tool for imaging the local atomic structure of materials. TEM has been used heavily in studies of defect structures of two-dimensional materials such as monolayer graphene due to its high dose efficiency. However, phase-contrast imaging can produce complex nonlinear contrast, even for weakly scattering samples. It is, therefore, difficult to develop fully automated analysis routines for phase-contrast TEM studies using conventional image processing tools. For automated analysis of large sample regions of graphene, one of the key problems is segmentation between the structure of interest and unwanted structures such as surface contaminant layers. In this study, we compare the performance of a conventional Bragg filtering method with a deep learning routine based on the U-Net architecture. We show that the deep learning method is more general, simpler to apply in practice, and produces more accurate and robust results than the conventional algorithm. We provide easily adaptable source code for all results in this paper and discuss potential applications for deep learning in fully automated TEM image analysis.

47 OTHER INSTRUMENTATION↗

Ex-situ Heat Treatment of TEM Foils in a Custom Titanium Fixture: A Case Study on Ni-based Superalloy

The advancement of microstructural characterization at the nanoscale is critical to understanding the microstructural evolution and performance of engineering materials. Transmission electron microscopy (TEM) plays a vital role in such investigations, particularly when coupled with controlled ex- and in-situ experiments. In this study, we introduce a novel method for ex-situ heat treatment (HT) of TEM foils using a custom-designed fixture, made from pure titanium, and vacuum furnace to inhibit oxidation. This approach ensures precise temperature control and minimal sample contamination during HT, critical for substructural characterization and analysis of metallic materials. The fixture consists of a titanium base with three slits, for three sample foils, and a titanium cap for closure. The entire assembly is placed in a vacuum heat treatment furnace with high vacuum capability to prevent oxidation. To validate the effectiveness of the setup, precipitation behavior and microstructural changes were studied in an IN725 variant heat-treated at 500°C for 1 hour and 282 variant heat-treated at 700°C for 1 hour, as case studies.

electron microscopy↗