Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volume Ray Tracing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A parametric study of the beam refraction problems across laser anemometer windows

The experimenter is often required to view flows through a window with a different index of refraction than either the medium being observed or the medium that the laser anemometer is immersed in. The refraction that occurs at the window surfaces may lead to undesirable changes in probe volume position or beam crossing angle and can lead to partial or complete beam uncrossing. This report describes the results of a parametric study of this problem using a ray tracing technique to predict these changes. The windows studied were a flat plate and a simple cylinder. For the flat-plate study: (1) surface thickness, (2) beam crossing angle, (3) bisecting line - surface normal angle, and (4) incoming beam plane surface orientation were varied. For the cylindrical window additional parameters were also varied: (1) probe volume immersion, (2) probe volume off-radial position, and (3) probe volume position out of the r-theta plane of the lens. A number of empirical correlations were deduced to aid the reader in determining the movement, uncrossing, and change in crossing angle for a particular situations.

Owen, Albert K.↗

SU-E-T-397: Evaluation of Planned Dose Distributions by Monte Carlo (0.5%) and Ray Tracing Algorithm for the Spinal Tumors with CyberKnife

Purpose: To analyze and evaluate dose distribution between Ray Tracing (RT) and Monte Carlo (MC) algorithms of 0.5% uncertainty on a critical structure of spinal cord and gross target volume and planning target volume. Methods: Twenty four spinal tumor patients were treated with stereotactic body radiotherapy (SBRT) by CyberKnife in 2013 and 2014. The MC algorithm with 0.5% of uncertainty is used to recalculate the dose distribution for the treatment plan of the patients using the same beams, beam directions, and monitor units (MUs). Results: The prescription doses are uniformly larger for MC plans than RT except one case. Up to a factor of 1.19 for 0.25cc threshold volume and 1.14 for 1.2cc threshold volume of dose differences are observed for the spinal cord. Conclusion: The MC recalculated dose distributions are larger than the original MC calculations for the spinal tumor cases. Based on the accuracy of the MC calculations, more radiation dose might be delivered to the tumor targets and spinal cords with the increase prescription dose.

60 APPLIED LIFE SCIENCES↗

Multiferroic properties in Ba{sub 0.93}Bi{sub 0.07}Ti{sub 1-x}Mn{sub x}O{sub 3} ceramics

Nominal composition of Ba{sub 0.93}Bi{sub 0.07}Ti{sub 1-x}Mn{sub x}O{sub 3} (x=0, 0.02, and 0.04) ceramics have been prepared by a modified Pechini method. X-ray diffraction analysis reveals that the samples are pure perovskite BaTiO{sub 3} (BTO) structure with no trace of impurity phase. The cell volume of the composites increases monotonously with the increase in Mn content, which indicates that Mn ions have been incorporated into the lattice of Ba{sub 0.93}Bi{sub 0.07}TiO{sub 3}. The samples are experimentally confirmed to show ferromagnetic (FM) and ferroelectric behaviors simultaneously at room temperature. The temperature dependent magnetic behaviors show complex magnetic interactions including FM, antiferromagnetic, and paramagnetic. These results suggest that the dopant Bi and Mn help BTO transit from pure ferroelectric to multiferroic materials and the magnetic behaviors can be explained by the bound magnetic polaron model with inhomogeneity of Mn dopant distribution.

36 MATERIALS SCIENCE↗

Population of 224 realistic human subject-based computational breast phantoms

Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was then applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range of breast types, volumes, densities, and parenchymal patterns.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-53: Treatment Planning with Inhomogeneity Correction for Intraoperative Radiotherapy Using KV X-Ray Beams

Purpose: The current standard in dose calculation for intraoperative radiotherapy (IORT) using the ZEISS Intrabeam 50 kV x-ray system is based on depth dose measurements in water and no heterogeneous tissue effect has been taken into account. We propose an algorithm for pre-treatment planning including inhomogeneity correction based on data of depth dose measurements in various tissue phantoms for kV x-rays. Methods: Direct depth dose measurements were made in air, water, inner bone and cortical bone phantoms for the Intrabeam 50 kV x-rays with a needle applicator. The data were modelled by a function of power law combining exponential with different parameters. Those phantom slabs used in the measurements were scanned to obtain CT numbers. The x-ray beam initiated from the source isocenter is ray-traced through tissues. The corresponding doses will be deposited/assigned at different depths. On the boundary of tissue/organ changes, the x-ray beam will be re-traced in new tissue/organ starting at an equivalent depth with the same dose. In principle, a volumetric dose distribution can be generated if enough directional beams are traced. In practice, a several typical rays traced may be adequate in providing estimates of maximum dose to the organ at risk and minimum dose in the target volume. Results: Depth dose measurements and modeling are shown in Figure 1. The dose versus CT number is shown in Figure 2. A computer program has been written for Kypho-IORT planning using those data. A direct measurement through 2 mm solid water, 2 mm inner bone, and 1 mm solid water yields a dose rate of 7.7 Gy/min. Our calculation shows 8.1±0.4 Gy/min, consistent with the measurement within 5%. Conclusion: The proposed method can be used to more accurately calculate the dose by taking into account the heterogeneous effect. The further validation includes comparison with Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

DEMNUni: ISW, Rees-Sciama, and weak-lensing in the presence of massive neutrinos

We present, for the first time in the literature, a full reconstruction of the total (linear and non-linear) ISW/Rees-Sciama effect in the presence of massive neutrinos, together with its cross-correlations with CMB-lensing and weak-lensing signals. The present analyses make use of all-sky maps extracted via ray-tracing across the gravitational potential distribution provided by the ''Dark Energy and Massive Neutrino Universe'' (DEMNUni) project, a set of large-volume, high-resolution cosmological N-body simulations, where neutrinos are treated as separate collisionless particles. We correctly recover, at 1–2% accuracy, the linear predictions from CAMB. Concerning the CMB-lensing and weak-lensing signals, we also recover, with similar accuracy, the signal predicted by Boltzmann codes, once non-linear neutrino corrections to HALOFIT are accounted for. Interestingly, in the ISW/Rees-Sciama signal, and its cross correlation with lensing, we find an excess of power with respect to the massless case, due to free streaming neutrinos, roughly at the transition scale between the linear and non-linear regimes. The excess is ∼ 5 – 10% at l ∼ 100 for the ISW/Rees-Sciama auto power spectrum, depending on the total neutrino mass M {sub ν}, and becomes a factor of ∼ 4 for M {sub ν} = 0.3 eV, at l ∼ 600, for the ISW/Rees-Sciama cross power with CMB-lensing. This effect should be taken into account for the correct estimation of the CMB temperature bispectrum in the presence of massive neutrinos.

79 ASTRONOMY AND ASTROPHYSICS↗

Stochastic Averaging of Radiative Transfer Coefficients for Relativistic Electrons

Abstract Synchrotron emissivities, absorptivities, and Faraday rotation and conversion coefficients are needed in modeling a variety of astrophysical sources, including Event Horizon Telescope (EHT) sources. We develop a method for estimating transfer coefficients that exploits their linear dependence on the electron distribution function, decomposing the distribution function into a sum of parts each of whose emissivity can be calculated easily. We refer to this procedure as stochastic averaging and apply it in two contexts. First, we use it to estimate the emissivity of an isotropicκdistribution function with a high-energy cutoff. The resulting coefficients can be evaluated efficiently enough to be used directly in ray-tracing calculations, and we provide an example calculation. Second, we use stochastic averaging to assess the effect of subgrid turbulence on the volume-averaged emissivity and along the way provide a prescription for a turbulent emissivity. We find that for parameters appropriate to EHT sources turbulence reduces the emissivity slightly. In the infrared, turbulence can dramatically increase the emissivity.

Astronomy & Astrophysics↗

CPU Isosurface Ray Tracing of Adaptive Mesh Refinement Data

Adaptive mesh refinement (AMR) is a key technology for large-scale simulations that allows for adaptively changing the simulation mesh resolution, resulting in significant computational and storage savings. However, visualizing such AMR data poses a significant challenge due to the difficulties introduced by the hierarchical representation when reconstructing continuous field values. Here, we detail a comprehensive solution for interactive isosurface rendering of block-structured AMR data. We contribute a novel reconstruction strategy—the octant method—which is continuous, adaptive and simple to implement. Furthermore, we present a generally applicable hybrid implicit isosurface ray-tracing method, which provides better rendering quality and performance than the built-in sampling-based approach in OSPRay. Finally, we integrate our octant method and hybrid isosurface geometry into OSPRay as a module, providing the ability to create high-quality interactive visualizations combining volume and isosurface representations of BS-AMR data. Lastly, we evaluate the rendering performance, memory consumption and quality of our method on two gigascale block-structured AMR datasets.

97 MATHEMATICS AND COMPUTING↗

ATDM Rover Milestone Report STDA02-1 (FY2017 Q4)

We have successfully completed the MS-4/Y1 Milestone STDA02-1 for the Rover Project. This document describes the milestone and provides an overview of the technical details and artifacts of the milestone. This milestone is focused on building a GPU accelerated ray tracing package capable of doing multi-group radiography, both back-lit and with self-emission as well as serving as a volume rendering plot in VisIt and other VTK-based visualization tools. The long term goal is a package with in-situ capability, but for this first version integration into VisIt is the primary goal. Milestone Execution Plan: Create API for GPU Raytracer that supports multi-group transport (up to hundreds of groups); Implement components into one or more of: VTK-m, VisIt, and a new library/package implementation to be hosted on LLNL Bitbucket (initially), before releasing to the wider community.

97 MATHEMATICS AND COMPUTING↗

Interpreting Broad Double-Peaked Emission Lines in Active Galactic Nuclei

The principal objectives of this project were to probe the inner regions of active galactic nuclei and to test general relativity in the strong-field limit. The approach takes advantage of broad atomic line emission observed from material deep in the potential well of an active galactic nucleus which contains key information as to the physics of the system. Line profiles in a wide range of wavebands from optical to X-ray have provided compelling evidence of the existence of a relativistic accretion disk around a supermassive black hole in a number of galaxies. The simplest model posits a geometrically thin disk in Keplerian orbit, with general relativistic effects in evidence. This model is the point of departure for the proposed work. We developed a high-performance numerical code to calculate photon trajectories in a Schwarzschild or Kerr metric and implemented it on parallel supercomputers. This code includes a general purpose ray tracer that calculates line profiles, light curves, and other observable quantities for a wide variety of emitter configurations. The versatility comes from the fact that the ray tracing algorithm does not depend on any symmetries regarding emitter locations. The speed comes from parallel implementation which enables us to sample hitherto unattainable volumes of disk model parameter space. During the period 1 March 1997 through 28 February 1998, two papers, supported in whole or in part by this grant, were published in refereed journals. They are reproduced in their entirety in the next two sections of this report.

Halpern, Jules↗

Multi-modal imaging of a single mouse brain over five orders of magnitude of resolution

Mammalian neurons operate at length scales spanning six orders of magnitude; they project millimeters to centimeters across brain regions, are composed of micrometer-scale-diameter myelinated axons, and ultimately form nanometer scale synapses. Capturing these anatomical features across that breadth of scale has required imaging samples with multiple independent imaging modalities. Translating between the different modalities, however, requires imaging the same brain with each. Here, we imaged the same postmortem mouse brain over five orders of spatial resolution using MRI, whole brain micrometer-scale synchrotron x-ray tomography ($\mu$CT), and large volume automated serial electron microscopy. Using this pipeline, we can track individual myelinated axons previously relegated to axon bundles in diffusion tensor MRI or arbitrarily trace neurons and their processes brain-wide and identify individual synapses on them. This pipeline provides both an unprecedented look across a single brain's multi-scaled organization as well as a vehicle for studying the brain's multi-scale pathologies.

59 BASIC BIOLOGICAL SCIENCES↗

Texture crossover : trace from multiple grains to a subgrain.

Neutron and synchrotron X-ray diffractions were used to study the texture development in the face-centered-cubic nickel-based superalloy over gauge volumes ranging from hundreds of cubic millimeters down to sub-cubic micrometers. The bulk averaged results find a uniform texture development from collective slip. However, X-ray microbeam studies at microscale find that the plastic deformation within a single grain is mediated by limited slip, as evidenced by the local strain distribution. Polychromatic microdiffraction shows the formation of several distinct structural zones even in the same grain. A hierarchical heterogeneous geometrically-necessary dislocations arrangement and distinct slip bands are observed within each grain. A depth-dependent change of the stereographic projection within the slip band in the grain is demonstrated. Correlated oscillations of the lattice orientation at the submicron scale evolve into an overall texture at the macroscale. Possible reasons for this observed structural evolution are discussed.

36 MATERIALS SCIENCE↗

Mars Spark Source Prototype Developed

The Mars Spark Source Prototype (MSSP) hardware was developed as part of a proof of concept system for the detection of trace metals such as lead, cadmium, and arsenic in Martian dusts and soils. A spark discharge produces plasma from a soil sample, and detectors measure the optical emission from metals in the plasma to identify and quantify them. Trace metal measurements are vital in assessing whether or not the Martian environment will be toxic to human explorers. The current method of x-ray fluorescence can yield concentrations of major species only. Other instruments are incompatible with the volume, weight, and power constraints for a Mars mission. The new instrument will be developed primarily for use in the Martian environment, but it would be adaptable for terrestrial use in environmental monitoring. The NASA Glenn Research Center at Lewis Field initiated the development of the MSSP as part of Glenn's Director's Discretionary Fund project for the Spark Analysis Detection of Trace Metal Species in Martian Dusts and Soils. The objective of this project is to develop and demonstrate a compact, sensitive optical instrument for the detection of trace hazardous metals in Martian dusts and soils.

Eichenberg, Dennis J.↗

Multichannel response analysis on 2D projection views for detection of clustered microcalcifications in digital breast tomosynthesis

Purpose: To investigate the feasibility of a new two-dimensional (2D) multichannel response (MCR) analysis approach for the detection of clustered microcalcifications (MCs) in digital breast tomosynthesis (DBT). Methods: With IRB approval and informed consent, a data set of two-view DBTs from 42 breasts containing biopsy-proven MC clusters was collected in this study. The authors developed a 2D approach for MC detection using projection view (PV) images rather than the reconstructed three-dimensional (3D) DBT volume. Signal-to-noise ratio (SNR) enhancement processing was first applied to each PV to enhance the potential MCs. The locations of MC candidates were then identified with iterative thresholding. The individual MCs were decomposed with Hermite–Gaussian (HG) and Laguerre–Gaussian (LG) basis functions and the channelized Hotelling model was trained to produce the MCRs for each MC on the 2D images. The MCRs from the PVs were fused in 3D by a coincidence counting method that backprojects the MC candidates on the PVs and traces the coincidence of their ray paths in 3D. The 3D MCR was used to differentiate the true MCs from false positives (FPs). Finally a dynamic clustering method was used to identify the potential MC clusters in the DBT volume based on the fact that true MCs of clinical significance appear in clusters. Using two-fold cross validation, the performance of the 3D MCR for classification of true and false MCs was estimated by the area under the receiver operating characteristic (ROC) curve and the overall performance of the MCR approach for detection of clustered MCs was assessed by free response receiver operating characteristic (FROC) analysis. Results: When the HG basis function was used for MCR analysis, the detection of MC cluster achieved case-based test sensitivities of 80% and 90% at the average FP rates of 0.65 and 1.55 FPs per DBT volume, respectively. With LG basis function, the average FP rates were 0.62 and 1.57 per DBT volume at the same sensitivity levels. The difference in the two sets of basis functions for detection of MCs did not show statistical significance. Conclusions: The authors' experimental results indicate that the MCR approach is promising for the detection of MCs on PV images. The HG or LG basis functions are both effective in characterizing the signal response of MCs using the channelized Hotelling model. The coincidence counting method for fusion of the 2D MCR in 3D is an important step for FP reduction. Further study is underway to improve the MCR approach for microcalcification detection in DBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A modified formula for dose calculations of stereotactic ablative body radiotherapy for non–small cell lung cancer

To provide a modified formula consistent with the Monte Carlo (MC) algorithm for dose calculations during stereotactic ablative body radiotherapy for non–small cell lung cancer. Seventy CyberKnife treatment plans were calculated and analyzed by MC and ray-tracing (RT) algorithms, separately. Parameters of treatment plans were compared, and those associated with differences of dose distributions were analyzed to establish a modified formula. Gross tumor volume and tumor tracking volume (TTV) were defined as the evident disease on the sequences of the window width and level of the lung and the mediastinum. Additionally, the formula was validated by another 20 plans. The prescription dose of the 90 patients was 60 Gy/5f. The RT algorithm overestimated the planning target volume (PTV) D{sub 95} by an average of 8.59 Gy and the gross tumor volume D{sub 99} by an average of 5.84 Gy. The homogeneity index of PTV was underestimated by 0.11 on average, whereas the conformity index and new conformity index was underestimated by 0.05. The RT algorithm overestimated the dose distribution to the spinal cord by 2.23 Gy, the esophagus by 1.96 Gy, the trachea by 1.89 Gy, the left-sided bronchus by 1.77 Gy, the right-sided bronchus by 1.64 Gy, and the heart by 2.16 Gy. The average whole-lung dose volumes of lung tissues and dose volumes of V{sub 5} were overestimated by 2.69 Gy and 7.52%, respectively. A power function distribution (R{sup 2} = 0.8626) was confirmed between PTV D{sub 95} and TTV volumes. PTV D{sub 95} calculated by the MC algorithm could be computed easily with TTV and PTV D{sub 95} calculated by the RT algorithm based on the formula. The modified equation was more consistent with MC algorithm than with other formula, which could be a reference to those not accessible to the MC algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large-scale homogeneity in the distribution of quasars in the Hercules-Corona Borealis Great Wall region

In light of recent debates on the existence of a gigaparsec-scale structure traced by gamma-ray bursts, namely the Hercules-Corona Borealis Great Wall (HCBGW), we revisit large-scale homogeneity in the spatial distribution of quasars. Our volume-limited sample of quasars in the redshift range 1:6 < z ≤ 2:1, which is constructed from the data release 7 of the Sloan Digital Sky Survey quasar catalogue, covers about half of the suspected HCBGW region. We analyze the sample in two complementary ways: fractal analysis of determining the average scale of homogeneity and friends- of-friends analysis of identifying specific large-scale structures. The quasar distribution on average reaches homogeneity at rh = 136 ± 38h-1 Mpc and the richness and comoving size frequencies of large (> ~ 150h-1 Mpc) quasar groups are consistent with the prediction of homogeneous distribution. These results put constraints on the spatial extent of the HCBGW but do not contradict its existence since our quasar sample does not cover the entire HCBGW region.

79 ASTRONOMY AND ASTROPHYSICS↗

Optics of Water Microdroplets with Soot Inclusions: Exact Versus Approximate Results

We use the recently generalized version of the multi-sphere superposition T-matrix method (STMM) to compute the scattering and absorption properties of microscopic water droplets contaminated by black carbon. The soot material is assumed to be randomly distributed throughout the droplet interior in the form of numerous small spherical inclusions. Our numerically-exact STMM results are compared with approximate ones obtained using the Maxwell-Garnett effective-medium approximation (MGA) and the Monte Carlo ray-tracing approximation (MCRTA). We show that the popular MGA can be used to calculate the droplet optical cross sections, single-scattering albedo, and asymmetry parameter provided that the soot inclusions are quasi-uniformly distributed throughout the droplet interior, but can fail in computations of the elements of the scattering matrix depending on the volume fraction of soot inclusions. The integral radiative characteristics computed with the MCRTA can deviate more significantly from their exact STMM counterparts, while accurate MCRTA computations of the phase function require droplet size parameters substantially exceeding 60.

cloud droplets↗

Spatial distribution of metals within the liver acinus and their perturbation by PCB126

Animal studies show that exposure to the environmental pollutant 3,3',4,4',5-pentachlorobiphenyl (PCB126) causes alterations in hepatic metals as measured in acid-digested volume-adjusted tissue. These studies lack the detail of the spatial distribution within the liver. Here we use X-ray fluorescence microscopy (XFM) to assess the spatial distribution of trace elements within liver tissue. Liver samples from male Sprague Dawley rats, treated either with vehicle or PCB126, were formalin fixed and paraffin embedded. Serial sections were prepared for traditional H&E staining or placed on silicon nitride windows for XFM. With XFM, metal gradients between the portal triad and the central vein were seen, especially with copper and iron. These gradients change with exposure to PCB126, even reverse. This is the first report of how micronutrients vary spatially within the liver and how they change in response to toxicant exposure. In addition, high concentrations of zinc clusters were discovered in the extracellular space. PCB126 treatment did not affect their presence, but did alter their elemental makeup suggesting a more general biological function. Further work is needed to properly evaluate the gradients and their alterations as well as classify the zinc clusters to determine their role in liver function and zinc homeostasis.