Search NASASearch

SEARCH · Search NASA

Results for “X-RAY DIFFRACTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

394 records · Page 3

X-Ray Polarization of Z-Type Neutron Star Low-Mass X-Ray Binaries II. Spectropolarimetric Analysis

IXPE has provided for the first time detailed energy- and time-resolved X-ray polarimetry of Z-type neutron star low-mass X-ray binaries (NS-LMXBs) as they move along their color-color diagrams (CCDs). These sources can reach the highest polarization observed for NS-LXMBs in the 2–8 keV range when they move along the horizontal branch. In a previous paper, we characterized the spectral state of a sample of Z-sources using the CCD and estimated the polarization with model-independent analysis. Here, we present detailed spectropolarimetric analysis for each source on each branch using data from IXPE, NICER, and NuSTAR. The continuum X-ray emission of all the sources is well described with a combination of thermal accretion disk emission plus a harder Comptonized component. In addition, reflection features, in particular the relativistically broadened Fe Kα line, are observed for our sources, except GX 5–1. For most of the sources and branches, the main contribution to the X-ray emission and polarization is due to Comptonization: moving from the horizontal branch (HB) to the normal branch (NB), the polarization degree (PD) in the 2–8 keV band varies from about 6% to 3–4%, while the PD is loosely constrained in the flaring branch (FB), due to the shorter exposures. These PD values are significantly higher than theoretical expectations for typical spreading or boundary layer configurations. The polarization of the disk is generally lower (below 3%) but still higher than predictions for an electron scattering-dominated, plane-parallel atmosphere above the disk observed at the corresponding inclination. Moreover, the polarization angle (PA) of the disk seems to be significantly misaligned and not perpendicular to that of Comptonization. We find no correlation between the polarization signal and the inclination, nor with the contribution of reflected photons throughout the Z-track.

accretion

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber

Spatiotemporal Studies of Soluble Inorganic Nanostructures with X‐rays and Neutrons

This Review addresses the use of X-ray and neutron scattering as well as X-ray absorption to describe how inorganic nanostructured materials assemble, evolve, and function in solution. We first provide an overview of techniques and instrumentation (both large user facilities and benchtop). We review recent studies of soluble inorganic nanostructure assembly, covering the disciplines of materials synthesis, processes in nature, nuclear materials, and the widely applicable fundamental processes of hydrophobic interactions and ion pairing. Reviewed studies cover size regimes and length scales ranging from sub-Ångström (coordination chemistry and ion pairing) to several nanometers (molecular clusters, i.e. polyoxometalates, polyoxocations, and metal-organic polyhedra), to the mesoscale (supramolecular assembly processes). Reviewed studies predominantly exploit 1) SAXS/WAXS/SANS (small- and wide-angle X-ray or neutron scattering), 2) PDF (pair-distribution function analysis of X-ray total scattering), and 3) XANES and EXAFS (X-ray absorption near-edge structure and extended X-ray absorption fine structure, respectively). While the scattering techniques provide structural information, X-ray absorption yields the oxidation state in addition to the local coordination. Our goal for this Review is to provide information and inspiration for the inorganic/materials science communities that may benefit from elucidating the role of solution speciation in natural and synthetic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

X-ray tomography of damage dynamics in advanced materials using a laser wakefield accelerator

Additively manufactured (AM) metals offer the potential for customizable, cost-effective components, but qualification and certification are crucial. Key to this process is understanding pore dynamics under stress, typically analyzed using micro-computed tomography. This study introduces laboratory-scale “betatron” x-rays from laser wakefield acceleration as a high-throughput alternative for x-ray tomography of advanced materials, such as AM AlSi10Mg alloys. Coupled with 3D finite element modeling, this method provides detailed insights into stress-porosity interactions. The approach delivers high-resolution scans, revealing that pore shape and local triaxiality significantly influence fracture dynamics, supporting advanced material characterization. This work also demonstrates the potential and versatility of laser-betatron x-ray μCT for generating large datasets to accelerate our understanding of the stochastic, process-specific nature of pore formation in AM alloys.

Senthilkumaran, Vigneshvar

Localizing the non-thermal X-ray emission of PSR J2229+6114 from its multi-wavelength pulse profiles

Context.Pulsars are detected over the whole electromagnetic spectrum, from radio wavelengths up to very high energies, in the GeV-TeV range. While the radio emission site for young pulsars is well constrained to occur at altitudes about several percent of the light-cylinder radius andγ-ray emission is believed to be produced in the striped wind, outside the light cylinder, the non-thermal X-ray production site remains unknown. Aims.The aim of this Letter is to localize the non-thermal X-ray emission region based on a multi-wavelength pulse profile fitting for PSR J2229+6114, which stands as a particularly good candidate given its high X-ray brightness. Methods.Based on the geometry deduced from the joint radio andγ-ray pulse profiles, we fixed the magnetic axis inclination angle and the line-of-sight (LoS) inclination angle. However, we left the region of X-ray emission unlocalized, setting it somewhere between the surface and the light cylinder. We localized this region and its extension by fitting the X-ray pulse profile as observed by the NICER,NuSTAR, and RXTE telescopes in the ranges of 2–7 keV, 3–10 keV, and 9.4–22.4 keV, respectively. Results.We constrained the non-thermal X-ray emission to arise from altitudes between 0.2 r L and 0.55 r L wherer L is the light-cylinder radius. The magnetic obliquity is approximatelyα ≈ 45° −50° and the LoS inclination angle isζ ≈ 32° −48°. Conclusions.This Letter is among the first works to offer a tight constraint on the location of non-thermal X-ray emission from pulsars. We plan to apply this procedure to several other promising candidates to confirm this new result.

Astronomy & Astrophysics

Structured illumination for surface-resolved grazing-incidence X-ray scattering

Grazing-incidence (GI) scattering techniques are widely used to characterize thin films, offering high surface sensitivity and insight into morphology and structure. However, these approaches typically provide statistical averaged information due to elongated footprint or limited spatial resolution due to beam size. Here we introduce a method that combines structured illumination with GI X-ray scattering and leverages our computational imaging approach to resolve local structural details. We demonstrate that our method captures local features of an organic semiconductor thin film without the need for sample rotation as in tomography. The method expands GI techniques from statistical averaging to high-resolution imaging, thereby providing the capability for detailed analysis of local material properties, such as domain shape, orientation and polymorphism, which are critical for advancing material design towards more efficient and tailored materials.

Gursoy, Doga

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

SuperHERO X-ray Telescope Balloon Mission

The SuperHERO hard X-ray telescope will observe extended sources at unprecedented imaging resolution, revealing the origins of non-thermal emission in extreme astrophysical environments. Employing NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon platform, SuperHERO consists of seven identical, co-aligned telescopes with a combined effective area of 45 cm² at 30 keV. SuperHERO was selected in the APRA 2023 call as a five-year mission, with an inaugural two-day flight scheduled from Fort Sumner, New Mexico, in the fall of 2028. For its initial target, SuperHERO will observe the Crab pulsar wind nebula, localizing hard X-ray emission. Mission development is currently underway, with updates and status to be provided in this presentation.

Nick Thomas

X-Ray Absorption Spectroscopy in High Temperature Oxidation of Metals and Alloys

An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.

Daniele Gozzi

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE

The HEROIX Broadband X-Ray Space Telescope Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept envisions a next-generation broadband X-ray observatory designed to meet the astrophysics community’s need for high-angular-resolution studies of the Cosmic X-ray Background. Building on the science legacy of NASA’s NuSTAR mission and more than 30 years of advances in replicated NiCo shell technology at NASA Marshall, HEROIX proposes a space observatory comprising four co-aligned telescopes achieving 5 arcsecond half-power diameter (HPD) angular resolution. This capability, approached by the resolution demonstrated in the FOXSI-4 sounding rocket mission and under development through the SuperHERO balloon mission, will be extended to energies up to 80 keV through multilayer coatings. Marshall’s inhouse precision optics manufacturing enables an integrated effective area of 380 cm² at 30 keV, which, combined with high-resolution optics, opens new windows into extreme astrophysical non-thermal processes.

Nick Thomas

Effect of Preparation Conditions of Fe@SiO2 Catalyst on Its Structure Using High-Pressure Activity Studies in a 3D-Printed SS Microreactor

Fischer–Tropsch synthesis (FTS) in a 3D-printed stainless steel (SS) microchannel microreactor was investigated using Fe@SiO2 catalysts. The catalysts were prepared by two different techniques: one pot (OP) and autoclave (AC). The mesoporous structure of the two catalysts, Fe@SiO2 (OP) and Fe@SiO2 (AC), ensured a large contact area between the reactants and the catalyst. They were characterized by N2 physisorption, H2 temperature-programmed reduction (H2-TPR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), X-ray photoelectron microscopy (XPS), and thermogravimetric analysis–differential scanning calorimetry (TGA-DSC) techniques. The AC catalyst had a clear core–shell structure and showed a much greater surface area than that prepared by the OP method. The activities of the catalysts in terms of FTS were studied in the 200–350 °C temperature range at 20-bar pressure with a H2/CO molar ratio of 2:1. The Fe@SiO2 (AC) catalyst showed higher selectivity and higher CO conversion to olefins than Fe@SiO2 (OP). Stability studies of both catalysts were carried out for 30 h at 320 °C at 20 bar with a feed gas molar ratio of 2:1. The Fe@SiO2 (AC) catalyst showed higher stability and yielded consistent CO conversion compared to the Fe@SiO2 (OP) catalyst.

Biochemistry & Molecular Biology

Li 21 Ge 8 P 3 S 34 : New Lithium Superionic Conductor with Unprecedented Structural Type

Abstract Lithium superionic conductors are pivotal for enabling all‐solid‐state batteries, which aim to replace liquid electrolytes and enhance safety. Herein, we report the discovery of an unprecedented lithium superionic conductor, Li 21 Ge 8 P 3 S 34 , featuring a novel structural type and a new composition in the Li–Ge–P–S system. This material exhibits high lithium ionic conductivity of approximately 1.0 mS cm −1 at 303 K with a low activation energy of 0.20(1) eV. It's unique crystal structure was elucidated using three‐dimensional electron diffraction (3D ED) and further refined through combined powder X‐ray and neutron diffraction analyses. The structure consists of alternating two‐dimensional slabs: one of corner‐sharing GeS 4 tetrahedra and the other of isolated PS 4 tetrahedra, enabling efficient lithium‐ion transport through a tetrahedrally interconnected network of 1D, 2D, and 3D diffusion pathways. This distinctive structural motif provides a novel design strategy for next‐generation solid electrolytes, broadening the structural landscape of lithium superionic conductors. With further advancements in compositional tuning and interfacial engineering, Li 21 Ge 8 P 3 S 34 could contribute to the development of high‐performance all‐solid‐state batteries.

Chemistry

LBFD X-59 Propulsion Overview

The LBFD X-59 Propulsion Overview is prepared in support of a panel session at the 2026 AIAA Aviation Conference. The overview covers highlights of the X-59 propulsion system, a short history of propulsion testing at NASA GRC, A summary of X-59 ground testing, a summary of X-59 flight testing, and finally some lessons learned.

Aerodynamic