Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery heat generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Heat Battery for Electrical Grid Energy

In this paper, the fundamental principles from the Georgetown Systems Engineering Fundamentals course will be leveraged to provide a viable solution to the problem of providing cost effective energy storage for renewable electricity generation. As described in the need statement, this is necessary due to the non-dispatchable nature of renewable energy sources. Upon describing the need, several key stakeholders were identified, who may or may not directly interact with the system. They provided several characteristics and capabilities that the system should contain, as well as specific key acceptance criteria which serve as a pass/fail metric for the concept selection process. Out of three different concepts, a Pugh matrix was used to determine that a heat battery system would be the right fit for the scope of work needing to be done.

25 ENERGY STORAGE↗

Integration of Heat Pumps With Solar Thermal Systems for Energy Storage

This chapter considers the combination of solar thermal systems with an energy storage device known as a Carnot Battery which charges thermal storage with a heat pump or electric heater. Integrating these systems can provide a variety of advantages, such as dispatchable renewable power generation and electricity storage services. In this chapter a variety of methods for hybridizing these systems are described, and ideal cycle analysis is used to assess their relative merits.

Carnot Battery↗

CHARACTERIZATION AND DEVELOPMENT OF THE ALL–AQUEOUS COPPER THERMALLY REGENERATIVE AMMONIA BATTERY

Low temperature thermal energy is an abundant and untapped energy source for large scale electrical power and energy production around the world. Many different stationary sources such as industrial and thermal power plants produce significant amounts of low temperature heat that goes unused. The primary reason for the energy loss is because the temperature of the heat is often too low for traditional systems to economically generate power from this waste heat. Many different technologies are being researched to produce grid–scale power from low temperature heat to increase grid efficiency, advance decarbonization efforts, and progress electrical power production to a more distributed system. A thermally regenerative battery (TRB) is one promising technology in this space, as it has large power and energy densities relative to competitive technologies and therefore has the potential to disrupt the current power generation mix. TRBs combine two unit operations (a redox flow battery and a distillation column) which are easily scalable and mature, meaning that if a viable TRB chemistry can be identified, its development to pilot and commercial scale can be streamlined. The all–aqueous, copper thermally regenerative ammonia battery (Cuaq–TRAB) was the first TRB that did not use an electrodeposition/dissolution reaction by stabilizing Cu(I) and Cu(II) in the electrolyte, allowing all electroactive species to be stable in an aqueous phase. Through these electrolyte modifications, coulombic efficiency, open circuit potential, and copper solubility all increased, resulting in large gains to power density, energy density, and energy efficiency.

Cross, Nicholas↗

Quantifying Socioeconomic Impacts of Electricity Generating Technologies

The levelized cost of energy (LCOE) and other cost metrics used in energy planning do not account for out-of-market impacts of the technology choice. While a decision-maker at the utility or asset owner level may compare multiple forms of electricity generating technology using LCOE, a decision-maker over energy policy or community stakeholders may be interested in considering impacts beyond those that LCOE measures. This report quantifies economic impacts such as jobs and wage growth across electricity generation technologies then develops an approach to systematically compare socioeconomic metrics across technology choices. To address additional workforce related impacts, this report also compares the typical workforce education requirements and annual income levels for multiple types of electricity generating facilities. The grid scale electricity generating technologies analyzed in this report produce power using conventional hydroelectric dams, coal, natural gas, nuclear reactors, solar PV, land-based wind turbines, geothermal heat, and woody biomass combustion. Although it doesn’t generate electricity itself, the economic impacts associated with battery storage equipment manufacturing and installation were also analyzed.

03 NATURAL GAS↗

A Thermodynamic Reassessment of Lithium-Ion Battery Cathode Calorimetry

This work demonstrates how staged heat release from layered metal oxide cathodes in the presence of organic electrolytes can be predicted from basic thermodynamic properties. These prediction methods for heat release are an advancement compared to typical modeling approaches for thermal runaway in lithium-ion batteries, which tend to rely exclusively on calorimetry measurements of battery components. These calculations generate useful new insights when compared to calorimetry measurements for lithium cobalt oxide (LCO) as well as the most common varieties of nickel manganese cobalt oxide (NMC) and nickel cobalt aluminum oxide (NCA). Accurate trends in heat release with varying state of charge are predicted for all of these cathode materials. These results suggest that thermodynamic calculations utilizing a recently published database of properties are broadly applicable for predicting decomposition behavior of layered metal oxide cathodes. Aspects of literature calorimetry measurements relevant to thermal runaway modeling are identified and classified as thermodynamic or kinetic effects. The calorimetry measurements reviewed in this work will be useful for development of a new generation of thermal runaway models targeting applications where accurate maximum cell temperatures are required to predict cascading cell-to-cell propagation rates.

25 ENERGY STORAGE↗

Understanding the Nature of Capacity Decay and Interface Properties in Li//LiNi 0.5 Mn 1.5 O 4 Cells by Cycling Aging and Titration Techniques

The spinel structure LiNi 0.5 Mn 1.5 O 4 (LNMO) is a propitious cathode material for next-generation lithium-ion batteries for fast charge–discharge applications, but its capacity decay mechanism and rate-limiting process are not yet well understood. In this work, electrochemical impedance spectroscopy (EIS) with galvanostatic intermittent titration (GITT) and cycling aging techniques were employed to investigate the nature of capacity decay in disordered-phase LNMO. Different resistive components were separated after every 10 cycles. Cell overvoltages (ΔVs) due to ohmic conduction, charge transfer (CT), and concentration polarization (CP) were individually determined. Results revealed that the cell exhibited a higher ΔV at a higher discharged state. However, the ΔV value for CP was higher at a higher state of charge (SOC), and the overall LNMO/electrolyte interface played a major role in the rate-determining step. Battery life was estimated based on the results. Battery calendar life was found to be more vulnerable than cycle life. Furthermore, results also indicated that the working SOC range could be optimized based on the resistance analysis by avoiding those SOCs that have the most detrimental impact (e.g., heat generation and fire hazard).

25 ENERGY STORAGE↗

Flash Recycling of Graphite Anodes

The ever-increasing production of commercial lithium-ion batteries (LIBs) will result in a staggering accumulation of waste when they reach their end of life. A closed-loop solution, with effective recycling of spent LIBs, will lessen both the environmental impacts and economic cost of their use. Presently, <5% of spent LIBs are recycled and the regeneration of graphite anodes has, unfortunately, been mostly overlooked despite the considerable cost of battery-grade graphite. Here, in this work, an ultrafast flash recycling method to regenerate the graphite anode is developed and valuable battery metal resources are recovered. Selective Joule heating is applied for only seconds to efficiently decompose the resistive impurities. The generated inorganic salts, including lithium, cobalt, nickel, and manganese, can be easily recollected from the flashed anode waste using diluted acid, specifically 0.1 M HCl. The flash-recycled anode preserves the graphite structure and is coated with a solid-electrolyte-interphase-derived carbon shell, contributing to high initial specific capacity, superior rate performance, and cycling stability, when compared to anode materials recycled using a high-temperature-calcination method. Life-cycle-analysis relative to current graphite production and recycling methods indicate that flash recycling can significantly reduce the total energy consumption and greenhouse gas emission while turning anode recycling into an economically advantageous process.

36 MATERIALS SCIENCE↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Self-consistent theory of the Darrieus–Landau and Rayleigh–Taylor instabilities with self-generated magnetic fields

The Rayleigh–Taylor (RT) and Darrieus–Landau (DL) instabilities are studied in an inertial confinement fusion context within the framework of small critical-to-shell density ratio D R and weak acceleration regime, i.e., large Froude number Fr. The quasi-isobaric analysis in Sanz et al. is completed with the inclusion of non-isobaric and self-generated magnetic-field effects. The analysis is restricted to perturbation wavelengths k~1 larger than the conduction length scale at the ablation front, yet its validity ranges from wavelengths shorter and larger than the conduction layer width (distance between the ablation front and the critical surface). The use of a sharp boundary model leads to a single analytical expression of the dispersion relation encompassing both instabilities. The two new effects come into play by modifying the perturbed mass and momentum fluxes at the ablation front. The momentum flux (perturbed pressure at the spike) is the predominant stabilizing mechanism in the RT instability (overpressure) and the driving mechanism in the DL instability (underpressure). The non-isobaric effects notably modify the scaling laws in the DL limit, leading to an underpressure scaling as ~k –11/15 rather than ~k –2/5 obtained in the quasi-isobaric model. The magnetic fields are generated due to misalignment between pressure and density gradients (Biermann battery effect). They affect the hydrodynamics by bending the heat flux lines. Within the framework of this paper, they enhance ablation, resulting in a stabilizing effect that peaks for perturbation wavelengths comparable to the conduction layer width. Here, the combination of parameters D R Fr 2/3 defines the region of predominance of each instability in the dispersion relation. It is proven that the DL region falls outside of the parameter range in inertial confinement fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport Processes in a Li-ion Cell during an Internal Short-Circuit

Internal short-circuit in a lithium-ion cell causes an abrupt increase in cell temperature and triggers subsequent thermal runaway. In this work, we present a detailed electrochemical-thermal model to investigate the physical behavior during an internal short-circuit. Simulations at wide range of heat transfer coefficients and short-circuit resistances are conducted to illustrate electrochemical and thermal behavior under a wide range of conditions. The Joule heating at the shorted region promotes electrochemical reactions nearby, causing in-plane non-uniformity of electrolyte and active material transport. Furthermore, it is found that diffusion in solid active materials plays a significant role at very high shorting currents (~20 C), as electrochemical reactions rate are being controlled progressively more by availability of Li + at the interface, due to limitations in diffusion through the active material with increasing discharge rates. This diffusion limitation causes a drop in available energy, and subsequently a decrease in cell equilibrium potential and the heat generation rate at the location of the short. On the other hand, rapid depletion of lithium concentration in the electrolyte and accumulation on the electrode surface results in highly non-uniform transport properties resulting in higher heat generation rates. Hence, the heating regime shifts from "local heating" to "global heating". Based on the findings, important design parameters for battery safety are discussed.

25 ENERGY STORAGE↗

Facile etching for single crystal cathode materials

A recycling and synthesis of charge material for secondary batteries generates single-crystal charge materials for producing batteries with greater charge cycle longevity. Charge material particles undergo a heating for fusing or enhancing grain boundaries between polycrystalline particles. The resulting, more well-defined grain boundaries are easily etched by a relatively weak mineral acid solution. The acid solution removes material at the grain boundaries to separate secondary particles into primary particles along the grain boundaries. The resulting single crystal (monocrystalline) charge material particles are washed and filtered, and typically re-sintered to accommodate any needed lithium (lithium carbonate), and result in a charge material with larger surface area, higher lithium diffusivity and lower cation ordering.

Wang, Yan↗

Effects of Trigger Method on Fire Propagation during the Thermal Runaway Process in Li-ion Batteries

Lithium-ion batteries are prone to fire hazards due to the possibility of thermal runaway propagation. During battery product development and subsequent safety tests for design validation and safety certification, the thermal runaway onset is triggered by various test methods such as nail penetration, thermal ramp, or external short circuit. This failure initiation method affects the amount of heat contributions and the composition of gas generations. This study compares two such trigger methods, external heating and using a thermally-activated internal short circuit device (ISCD). The effects of the trigger method on total heat generation are experimentally investigated within 18650 cylindrical cells at single cell level as well as at multiple cell configuration level. The severity of failure was observed to be worse for cells with ISCDs at single cell level, whereas quite the opposite results were observed at multiple cell configuration level. A preliminary numerical analysis was performed to better understand the battery safety performance with respect to thermal runaway trigger methods and heat transfer conditions.

25 ENERGY STORAGE↗

Energy Storage Technologies and U.S. Department of War Requirements

This report offers an overarching primer the energy storage market and assessment of each technology’s suitability for U.S. Department of War applications. We find that battery energy storage is the most promising technology for energy storage applications in terms of energy density and cost. While commercial and advanced Li-ion can satisfy certain electric mobility (e.g., cars, midsized vehicles) and electric flight application (e.g. drones) needs of DoW, next generation technologies like Li metal solid-state batteries, and conversion chemistries (Li-air, Li-CFx) are needed for heavy duty applications like armored vehicles, tanks, airplanes, jets. Batteries should also be supplemented with technologies such as supercapacitors and next-generation flywheels to provide short bursts of high energy for high power needs. Thermal energy storage solutions (sensible and latent heat) and fuel cells (PEMFC and SOFC) are good alternatives for supporting energy storage applications in terms of energy density and cost. Gravity-based energy storage promises the least energy density with high cost and should only be used for niche DoW applications. Of the different gravity energy storage technologies reviewed, pumped-hydro, flywheel, and compressed air energy storage are promising, while solid gravity energy storage appears the least attractive. Military facilities requiring 14 days of energy storage can benefit from flow batteries, especially commercial VFRBs and next generation iron-air systems. While VFRBs are expensive, iron-air batteries have the coupled benefits of low cost and good energy density promising 100+ hours of storage.

25 ENERGY STORAGE↗

Passive heat removal in horizontally oriented micro-HTGRs

There are novel, horizontally oriented high-temperature gas-cooled micro-reactor (HTGR) designs under consideration because of their portability, simplicity, and reliable operation. These features of the micro-HTGR design can meet the fission battery attributes, such as economic, standardize, installed, unattended and reliable. Although there have been HTGR related safety studies, micro-HTGRs when horizontally oriented are expected to exhibit significantly different thermal physics. During the unavailability of helium circulation, the internal reactor core is designed to cool by block-to-block conduction and radiation, and the reactor vessel surface is cooled by the ambient air. This scenario is anticipated during the transport of the micro-HTGR in a shipping container. The conduction and radiation between the prismatic micro-HTGR blocks in the core can be influenced by variances in the thermal contacts. This work investigated the conduction within a simulated horizontal HTGR core. An experimental setup was used to validate a numerical model. The experimental setup consisted of a hexagonal assembly with scaled prismatic blocks placed within a high-temperature vacuum environment. The gaps between the blocks were well controlled and monitored. The experimental setup was designed in such a way that the temperature variation in the axial direction was minimal, such that the experiment could be observed as a 2D (r, ) heat transfer problem. The pressurized tube was equipped with Infra-Red (IR) transparent windows, and an IR camera was used to capture the spatio-temporal temperature evolution in the hexagonal block assembly during the cooldown experiments. The experimental scenario was computationally modeled with a finite element analysis (FEA) program. Once validated, the computational model was used to investigate the impact of gap conductance on overall decay heat removal. Using a conservative estimate for gap conductance value (100 W/m 2 -K) between the prismatic blocks, there is a negligible increase in temperature observed during decay heat generation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Market Brief: Customer-sited Distributed Energy Resources

This market brief summarizes key takeaways from interviews with vendors and service providers in one or more areas of the DER market: DER controls, battery storage, solar photovoltaic, thermal energy storage, combined heat and power, flexible building loads, and electric vehicle charging. Back-up generators used only in emergencies are not in the scope of this market brief.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Distribution System Operator with Transactive (DSO+T) Study

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution System Operator with Transactive (DSO+T) Study: Volume 1 (Main Report)

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗