Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Batch and column studies of radium, actinium, thorium and protactinium on CL resin in nitric acid, hydrochloric acid and hydrofluoric acid

CL resin (TrisKem International) was characterized for separations of radium, actinium, thorium and protactinium. Batch studies are presented for radium, actinium and thorium in HCl and HNO3 as well as for radium, thorium and protactinium in HF. The uptake of thorium from dilute HNO3 (≤ 10 -4 M) and dilute HCl (≤ 10 -4 M) was found to be very high (D w > 100 in HNO 3 and > 1000 in HCl). Kinetics studies on thorium were performed in HCl and HNO 3 to determine suitably for column separations. Six column separation studies are presented including the separation of trace thorium from radium and actinium in dilute HCl and HNO 3 , the separation of radium from 1 mg 232 Th in dilute HCl, the separation of thorium and radium in the presence of HCl and excess Cl-, the separation of radium, protactinium and thorium by retention of protactinium and the separation of protactinium and thorium by retention of thorium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adapting LEU-Modified Cintichem Process for Processing Up to 750 Grams of Uranium Targets

Argonne National Laboratory (Argonne) developed a low-enriched uranium (LEU)-modified Cintichem (LMC) process to enable production and purification of fission-produced molybdenum-99 (Mo-99) from LEU foil targets. This separation scheme starts with nitric acid (HNO 3 ) dissolution of irradiated LEU foil targets that yields an approximate final volume of 2 L. The dissolved uranium solution containing fission products, including Mo-99, is then treated by loading the solution on a titania-based recovery column to separate Mo-99 from bulk uranium. After several washing steps, Mo and other fission products are stripped from the titania column using sodium hydroxide (NaOH). The eluate is then acidified using nitric acid and subsequently processed for final purification using the LMC process. Uranium and most fission products are not adsorbed on the titania column but are eluted (i.e., removed using a solvent) during the wash steps; they can be purified and recycled into new uranium targets.

07 ISOTOPE AND RADIATION SOURCES↗

Health monitoring device

Example aspects of a volatile organic compound detection device, a wearable health monitoring device, and a method of monitoring a user's health are disclosed. The volatile organic compound detection device can comprise a collector comprising a collector material configured to collect volatile organic compounds given off from a user's skin; a separator comprising a gas chromatography column configured to separate mixtures of the volatile organic compounds into their constituent chemicals; and an identifier comprising a detector and a processor, the detector configured to transduce the constituent chemicals into a signal, the processor configured to process the signal to identify specific volatile organic compounds indicative of a health condition.

42 ENGINEERING↗

Partitioning of Radionuclides in Various Streams of the Mo-99 Purification Process

The Universal Neutron Irradiator (UNI) was designed to irradiate a small volume of uranium solution and to achieve high fission power without creating a large radionuclide (RN) inventory. The UNI system is equipped with a fully enclosed off-gas system with online hydrogen gas monitoring to prevent the production of an explosive atmosphere, as well as storage cylinders for capturing fission gases. It also includes a catalytic recombiner in the target capsule (to immediately recombine radiolytic hydrogen and oxygen gas in the system) and access ports for sampling the target solution and capsule headspace. In UNI Phase I experiments, 50 mL of uranyl sulfate solution was irradiated at 0.3–0.5 W/mL fission power using a tantalum target assembly to produce photoneutrons via irradiation with an electron beam. The purposes of the Phase I experiments were to test the efficacy of adding 200 ppm Fe 2+ to the target solution to prevent uranyl peroxide precipitation under representative irradiation conditions, and to monitor iodine speciation in the irradiated uranyl sulfate solution. The focus of the UNI Phase II experiments was to use an irradiated uranyl sulfate solution containing a mixture of fission products and monitor their distribution in various streams during the primary recovery column (titania-based column) that separates Mo-99 from uranium. Irradiations were designed to create sufficient activity for tracking their distribution in various processing streams using a combination of gamma counting and inductively coupled plasma mass spectrometry (ICP-MS) analyses. Obtained data will be used to better understand the composition of waste streams, accumulation of RN on the titania column, and identify what RNs accumulate in the uranyl sulfate solution. Furthermore, this knowledge will allow us to determine waste classifications for various streams produced during the Mo-99 purification process and develop an appropriate waste clean-up strategy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced rare-earth separation with a metal-sensitive lanmodulin dimer

Technologically critical rare-earth elements are notoriously difficult to separate, owing to their subtle differences in ionic radius and coordination number. The natural lanthanide-binding protein lanmodulin (LanM) is a sustainable alternative to conventional solvent-extraction-based separation. Here we characterize a new LanM, from Hansschlegelia quercus (Hans-LanM), with an oligomeric state sensitive to rare-earth ionic radius, the lanthanum(III)-induced dimer being >100-fold tighter than the dysprosium(III)-induced dimer. X-ray crystal structures illustrate how picometre-scale differences in radius between lanthanum(III) and dysprosium(III) are propagated to Hans-LanM’s quaternary structure through a carboxylate shift that rearranges a second-sphere hydrogen-bonding network. Comparison to the prototypal LanM from Methylorubrum extorquens reveals distinct metal coordination strategies, rationalizing Hans-LanM’s greater selectivity within the rare-earth elements. Finally, structure-guided mutagenesis of a key residue at the Hans-LanM dimer interface modulates dimerization in solution and enables single-stage, column-based separation of a neodymium(III)/dysprosium(III) mixture to >98% individual element purities. This work showcases the natural diversity of selective lanthanide recognition motifs, and it reveals rare-earth-sensitive dimerization as a biological principle by which to tune the performance of biomolecule-based separation processes.

36 MATERIALS SCIENCE↗

Uptake behavior of 73 As, 75 Se, 197m Hg, 212 Pb and 210 Po on Eichrom pre-filter resin from HCl and HNO 3

We report the extraction of 73 As, 75 Se, 197 mHg, 212 Pb and 210 Po on Eichrom pre-filter resin was studied in HCl and HNO 3 with batch uptake, kinetic and column experiments. There was significant extraction of mercury in HNO 3 and HCl, and polonium and selenium in HCl. The kinetics are sufficient to allow for retention on pre-filter columns, and separations of 73 As from 75 Se and 197 mHg, and 212 Pb from 210 Po are demonstrated. This retention is important for the development of chemical separations as pre-filter resin is commonly used alongside extraction chromatography resins but its potential for uptake of metal ions is not well characterized.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radiation Controllable Synthesis of Robust Covalent Organic Framework Conjugates for Efficient Dynamic Column Extraction of 99 TcO4 -

Wang et al. report here an ultra-robust imidazolium-decorated covalent organic framework (COF) conjugate fabricated by an ionizing radiation strategy for efficient capture of 99 TcO 4 -, where tunable ReO 4 - uptake up to 952 mg g -1 can be achieved by simply adjusting the γ-ray dose. The COFs feature high porosity, ultra-robust nanofiber structure, and fast adsorption kinetics, thus emphasizing their advantages in terms of column experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UV–Vis–NIR Reflectance Spectroscopy and Chemometrics for Monitoring Pu Directly on an Ion Exchange Column

Here, we present a fiber-optic UV–vis–NIR reflectance spectroscopy method for direct, noninvasive monitoring of Pu(IV) in a glass ion exchange column during dynamic loading and elution in a glovebox. A movable probe enables spatially resolved spectral acquisition along the column axis, capturing distinct features associated with Pu(IV) nitrate complexes during loading and free ions during elution. Principal component analysis was applied to extract the dominant spectral variance and resolve relative concentration profiles without requiring precise knowledge of optical penetration depth or species identity. This in situ approach reveals spatial gradients and speciation dynamics in real time, which provides actionable insight into Pu(IV) ion migration, resin saturation, and breakthrough behavior under evolving flow conditions. The method offers a practical, fiber-compatible strategy to monitor glass column–based separations for Pu and other lanthanides or actinides and to characterize metal–resin interactions in flow-through systems.

actinide↗

Recycling Isotopically Enriched Mo from the RadioGenix Waste Stream

NorthStar’s RadioGenix generator utilizes an aqueous biphasic extraction chromatography column to separate Tc from low-specific-activity 99 Mo. During this separation process, a fraction of the source Mo material can be found in the waste. This is not of concern when natural Mo targets are used. However, the introduction of isotopically enriched 98 Mo for neutron capture or 100 Mo for accelerator-based production requires recovery of this valuable enriched Mo material. The generator waste is absorbed and solidified in a superabsorbent hydrogel polymer. In this contribution, we report results from our small-scale experimental study on development of a separation process for recovery of molybdenum from the polymeric gel waste using common chemicals and simple chemical techniques. Our investigation confirms that the acidic deswelling of the alkaline hydrogel with concentrated hydrochloric acid converts the occluded molybdate to a neutral molybdenyl dichloride species that is freely released from the gel. Mo can then be concentrated on a commercial tri-n-butyl phosphate resin, eluted with ammonium hydroxide, and crystallized as ammonium heptamolybdate for conversion back to Mo metal. Typical Mo recoveries are 90-95%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microbe-Encapsulated Silica Gel Biosorbents for Selective Extraction of Scandium from Coal Byproducts

Establishing an inexpensive and environmentally friendly scandium (Sc) supply is critical for the development of clean energy technologies. However, refining Sc from Sc-bearing sources using current technologies poses economic and environmental challenges due to its low concentration relative to base metals and chemically similar lanthanides. In this work, we developed a biosorption-based flow-through process for extraction of Sc from low-grade feedstocks. A novel biosorbent material was synthesized by encapsulating Arthrobacter nicotianae, a bacterium that selectively adsorbs Sc, within a porous silica matrix. Through the use of several complementary microscopy techniques, we demonstrated a highly porous biosorbent structure with a high cell-loading density and a homogenous cell distribution. Batch adsorption assays revealed selective Sc adsorption over lanthanides and common based metals, with the exception of Fe(III), as evidenced by separation factors greater than 50. The MESG particles were packed into fixed-bed columns to enable adsorption under flow-through conditions, which demonstrated effective Sc extraction at flow rates up to 0.08 cm/s and high stability for reuse; greater than 95% of the adsorption capacity was maintained after 10 consecutive adsorption/desorption cycles. When applied to a lignite coal leachate, whose Fe content was depleted through pH-mediated precipitation, the MESG particles yielded Sc breakthrough at 30 bed volumes, whereas all other metals broke through after only a few bed volumes. Following desorption, an eluate with a 124-fold increase in Sc purity was achieved relative to the lignite leachate with Sc constituting 96.4% of the total REEs. This study established a rapid, facile, and scalable cell immobilization approach that enables the use of microbial biomass for Sc recovery from low-grade sources.

Dong, Ziye↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RAPID UNSEPARATED RARE EARTH ELEMENT ANALYSES BY ISOTOPE DILUTION MULTICOLLECTOR INDUCTIVELY COUPLED MASS SPECTROMETRY (ID-MC-ICP-MS)

We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.

Shen, Steve D.↗

Improved Single-Cell Proteome Coverage Using Narrow-Bore Packed NanoLC Columns and Ultrasensitive Mass Spectrometry

Single-cell proteomics can provide unique insights into biological processes by resolving heterogeneity that is obscured by bulk measurements. Gains in the overall sensitivity and proteome coverage through improvements in sample processing and analysis increase the information content obtained from each cell, particularly for less abundant proteins. Here we report on improved single-cell proteome coverage through the combination of the previously developed Nanodroplet Processing in One Pot for Trace Samples (nanoPOTS) platform with further miniaturization of liquid chromatography (LC) separations and implementation of an ultrasensitive latest-generation mass spectrometry (MS) instrument. Following nanoPOTS sample preparation, protein digest from single cells were separated using a 20-µm-i.d. in-house-packed nanoLC column. Separated peptides were ionized using an etched fused silica emitter capable of stable ionization at the ~20 nL/min flow rate provided by the LC separation. Ultrasensitive LC-MS analysis was achieved using the Orbitrap Eclipse Tribrid mass spectrometer. An average of 362 protein groups were identified by MS/MS from single HeLa cells, and 874 protein groups were identified using the Match Between Runs (MBR) feature of MaxQuant. This represents a >70% increase in label-free proteome coverage for single cells relative to previous efforts using larger-bore (30-µm-i.d.) LC columns coupled to a previous-generation MS (Orbitrap Fusion Lumos).

Cong, Yongzheng↗

Linear stability analysis of two fluid columns of different densities and viscosities in a gravity field

The linear stability of a vertical interface separating two miscible fluid columns of different densities and viscosities under the influence of gravity is investigated. This flow possesses a time-dependent reference state (each column accelerates at different rates owing to their different densities) and the interface thickness grows as the square root of time (by diffusion). Numerical integration of the linear initial-value problem is carried out and discussed in detail as a function of vertical and spanwise wavenumbers and the flow parameters. Adjoint-based optimization is performed in order to determine initial conditions that lead to maximum growth of disturbances in finite time. Results indicate that the rate of growth of the perturbation energy at small wavenumbers (less affected by viscosity initially) is dominated by two-dimensional modes (no spanwise variation). Substantial transient growth is observed at higher wave modes initially, followed by asymptotic decay of the perturbations at large time. Sensitivity of perturbation growth with respect to initial time, density and viscosity ratios is investigated. This work is complementary to previous inviscid analysis of this configuration, which showed that the interface was unconditionally unstable at all wave modes, even in the presence of surface tension, and that instability grew as the exponential of time squared.

Mechanics↗