Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Internal additive noise effects in stochastic resonance using organic field effect transistor

Stochastic resonance phenomenon was observed in organic field effect transistor using poly(3-hexylthiophene), which enhances performance of signal transmission with application of noise. The enhancement of correlation coefficient between the input and output signals was low, and the variation of correlation coefficient was not remarkable with respect to the intensity of external noise, which was due to the existence of internal additive noise following the nonlinear threshold response. In other words, internal additive noise plays a positive role on the capability of approximately constant signal transmission regardless of noise intensity, which can be said “homeostatic” behavior or “noise robustness” against external noise. Furthermore, internal additive noise causes emergence of the stochastic resonance effect even on the threshold unit without internal additive noise on which the correlation coefficient usually decreases monotonically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-120: Comparing 4D CT Computed Ventilation to Lung Function Measured with Hyperpolarized Xenon-129 MRI

Purpose: To correlate ventilation parameters computed from 4D CT to ventilation, profusion, and gas exchange measured with hyperpolarized Xenon-129 MRI for a set of lung cancer patients. Methods: Hyperpolarized Xe-129 MRI lung scans were acquired for lung cancer patients, before and after radiation therapy, measuring ventilation, perfusion, and gas exchange. In the standard clinical workflow, these patients also received 4D CT scans before treatment. Ventilation was computed from 4D CT using deformable image registration (DIR). All phases of the 4D CT scan were registered using a B-spline deformable registration. Ventilation at the voxel level was then computed for each phase based on a Jacobian volume expansion metric, yielding phase sorted ventilation images. Ventilation based upon 4D CT and Xe-129 MRI were co-registered, allowing qualitative visual comparison and qualitative comparison via the Pearson correlation coefficient. Results: Analysis shows a weak correlation between hyperpolarized Xe-129 MRI and 4D CT DIR ventilation, with a Pearson correlation coefficient of 0.17 to 0.22. Further work will refine the DIR parameters to optimize the correlation. The weak correlation could be due to the limitations of 4D CT, registration algorithms, or the Xe-129 MRI imaging. Continued development will refine parameters to optimize correlation. Conclusion: Current analysis yields a minimal correlation between 4D CT DIR and Xe-129 MRI ventilation. Funding provided by the 2014 George Amorino Pilot Grant in Radiation Oncology at the University of Virginia.

60 APPLIED LIFE SCIENCES↗

Automated fibroglandular tissue segmentation and volumetric density estimation in breast MRI using an atlas-aided fuzzy C-means method

Purpose: Breast magnetic resonance imaging (MRI) plays an important role in the clinical management of breast cancer. Studies suggest that the relative amount of fibroglandular (i.e., dense) tissue in the breast as quantified in MR images can be predictive of the risk for developing breast cancer, especially for high-risk women. Automated segmentation of the fibroglandular tissue and volumetric density estimation in breast MRI could therefore be useful for breast cancer risk assessment. Methods: In this work the authors develop and validate a fully automated segmentation algorithm, namely, an atlas-aided fuzzy C-means (FCM-Atlas) method, to estimate the volumetric amount of fibroglandular tissue in breast MRI. The FCM-Atlas is a 2D segmentation method working on a slice-by-slice basis. FCM clustering is first applied to the intensity space of each 2D MR slice to produce an initial voxelwise likelihood map of fibroglandular tissue. Then a prior learned fibroglandular tissue likelihood atlas is incorporated to refine the initial FCM likelihood map to achieve enhanced segmentation, from which the absolute volume of the fibroglandular tissue (|FGT|) and the relative amount (i.e., percentage) of the |FGT| relative to the whole breast volume (FGT%) are computed. The authors' method is evaluated by a representative dataset of 60 3D bilateral breast MRI scans (120 breasts) that span the full breast density range of the American College of Radiology Breast Imaging Reporting and Data System. The automated segmentation is compared to manual segmentation obtained by two experienced breast imaging radiologists. Segmentation performance is assessed by linear regression, Pearson's correlation coefficients, Student's pairedt-test, and Dice's similarity coefficients (DSC). Results: The inter-reader correlation is 0.97 for FGT% and 0.95 for |FGT|. When compared to the average of the two readers’ manual segmentation, the proposed FCM-Atlas method achieves a correlation ofr = 0.92 for FGT% and r = 0.93 for |FGT|, and the automated segmentation is not statistically significantly different (p = 0.46 for FGT% and p = 0.55 for |FGT|). The bilateral correlation between left breasts and right breasts for the FGT% is 0.94, 0.92, and 0.95 for reader 1, reader 2, and the FCM-Atlas, respectively; likewise, for the |FGT|, it is 0.92, 0.92, and 0.93, respectively. For the spatial segmentation agreement, the automated algorithm achieves a DSC of 0.69 ± 0.1 when compared to reader 1 and 0.61 ± 0.1 for reader 2, respectively, while the DSC between the two readers’ manual segmentation is 0.67 ± 0.15. Additional robustness analysis shows that the segmentation performance of the authors' method is stable both with respect to selecting different cases and to varying the number of cases needed to construct the prior probability atlas. The authors' results also show that the proposed FCM-Atlas method outperforms the commonly used two-cluster FCM-alone method. The authors' method runs at ∼5 min for each 3D bilateral MR scan (56 slices) for computing the FGT% and |FGT|, compared to ∼55 min needed for manual segmentation for the same purpose. Conclusions: The authors' method achieves robust segmentation and can serve as an efficient tool for processing large clinical datasets for quantifying the fibroglandular tissue content in breast MRI. It holds a great potential to support clinical applications in the future including breast cancer risk assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Relations among Solid Precipitation, Atmospheric Moisture and Cloud Parameters in the Arctic

Observations collected during cold-season precipitation periods at Utquagvik, Alaska and at the multidisciplinary drifting observatory for the study of Arctic climate (MOSAiC) are used to statistically analyze the relations among the atmospheric water cycle parameters including the columnar supercooled liquid and ice amounts (expressed as liquid-water and ice-water paths, i.e., LWP and IWP), the integrated water vapor (IWV) and the near-surface snowfall rate. Data come from radar and radiometer-based retrievals and from optical precipitation sensors. While the correlation between snowfall rate and LWP is rather weak, correlation coefficients between radar-derived snowfall rate and IWP are high (~0.8), which is explained, in part, by the generally low LWP/IWP ratios during significant precipitation. Correlation coefficients between snowfall rate and IWV are moderate (~0.45). Correlations are generally weaker if snowfall is estimated by optical sensors, which is, in part, due to blowing snow. Correlation coefficients between near-surface temperature and snowfall rates are low (r < 0.3). The results from the Alaska and MOSAiC sites are generally similar. These results are not very sensitive to the amount of time averaging (e.g., 15 min averaging versus daily averages). Observationally based relations among the water cycle parameters are informative about atmospheric moisture conversion processes and can be used for model evaluations.

54 ENVIRONMENTAL SCIENCES↗

SU-D-207B-01: Radiomics Feature Reproducibility From Repeat CT Scans of Patients with Rectal Cancer

Purpose: To evaluate the reproducibility of radiomics features by repeating computed tomographic (CT) scans in rectal cancer. To choose stable radiomics features for rectal cancer. Methods: 40 rectal cancer patients were enrolled in this study, each of whom underwent two CT scans within average 8.7 days (5 days to 17 days), before any treatment was delivered. The rectal gross tumor volume (GTV) was distinguished and segmented by an experienced oncologist in both CTs. Totally, more than 2000 radiomics features were defined in this study, which were divided into four groups (I: GLCM, II: GLRLM III: Wavelet GLCM and IV: Wavelet GLRLM). For each group, five types of features were extracted (Max slice: features from the largest slice of target images, Max value: features from all slices of target images and choose the maximum value, Min value: minimum value of features for all slices, Average value: average value of features for all slices, Matrix sum: all slices of target images translate into GLCM and GLRLM matrices and superpose all matrices, then extract features from the superposed matrix). Meanwhile a LOG (Laplace of Gauss) filter with different parameters was applied to these images. Concordance correlation coefficients (CCC) and inter-class correlation coefficients (ICC) were calculated to assess the reproducibility. Results: 403 radiomics features were extracted from each type of patients’ medical images. Features of average type are the most reproducible. Different filters have little effect for radiomics features. For the average type features, 253 out of 403 features (62.8%) showed high reproducibility (ICC≥0.8), 133 out of 403 features (33.0%) showed medium reproducibility (0.8≥ICC≥0.5) and 17 out of 403 features (4.2%) showed low reproducibility (ICC≥0.5). Conclusion: The average type radiomics features are the most stable features in rectal cancer. Further analysis of these features of rectal cancer can be warranted for treatment monitoring and prognosis prediction.

60 APPLIED LIFE SCIENCES↗

SU-F-R-33: Can CT and CBCT Be Used Simultaneously for Radiomics Analysis

Purpose: To investigate whether CBCT and CT can be used in radiomics analysis simultaneously. To establish a batch correction method for radiomics in two similar image modalities. Methods: Four sites including rectum, bladder, femoral head and lung were considered as region of interest (ROI) in this study. For each site, 10 treatment planning CT images were collected. And 10 CBCT images which came from same site of same patient were acquired at first radiotherapy fraction. 253 radiomics features, which were selected by our test-retest study at rectum cancer CT (ICC>0.8), were calculated for both CBCT and CT images in MATLAB. Simple scaling (z-score) and nonlinear correction methods were applied to the CBCT radiomics features. The Pearson Correlation Coefficient was calculated to analyze the correlation between radiomics features of CT and CBCT images before and after correction. Cluster analysis of mixed data (for each site, 5 CT and 5 CBCT data are randomly selected) was implemented to validate the feasibility to merge radiomics data from CBCT and CT. The consistency of clustering result and site grouping was verified by a chi-square test for different datasets respectively. Results: For simple scaling, 234 of the 253 features have correlation coefficient ρ>0.8 among which 154 features haveρ>0.9 . For radiomics data after nonlinear correction, 240 of the 253 features have ρ>0.8 among which 220 features have ρ>0.9. Cluster analysis of mixed data shows that data of four sites was almost precisely separated for simple scaling(p=1.29 * 10{sup −7}, χ{sup 2} test) and nonlinear correction (p=5.98 * 10{sup −7}, χ{sup 2} test), which is similar to the cluster result of CT data (p=4.52 * 10{sup −8}, χ{sup 2} test). Conclusion: Radiomics data from CBCT can be merged with those from CT by simple scaling or nonlinear correction for radiomics analysis.

60 APPLIED LIFE SCIENCES↗

Phase identification using statistical analysis

A device includes at least one processor configured to determine, based on (i) a first plurality of time-varying electrical measurements corresponding to a feeder head of a power distribution network having a plurality of phases and (ii) a second plurality of time-varying electrical measurements corresponding to a node in the power distribution network, and using statistical analysis, a predicted phase, from the plurality of phases, that corresponds to the node. The processor may be configured to use ranked correlation coefficients (such as the Kendall rank correlation coefficient) to determine the predicted phase and may use principle component analysis. The processor is also configured to cause at least one device of the power distribution network to modify operation based at least on part on the predicted phase.

Veda, Santosh Sambamoorthy↗

The Dosimetric Effect of Intrafraction Prostate Motion on Step-and-Shoot Intensity-Modulated Radiation Therapy Plans: Magnitude, Correlation With Motion Parameters, and Comparison With Helical Tomotherapy Plans

Purpose: To determine the daily and cumulative dosimetric effects of intrafraction prostate motion on step-and-shoot (SNS) intensity-modulated radiation therapy (IMRT) plans, to evaluate the correlation of dosimetric effect with motion-based metrics, and to compare on a fraction-by-fraction basis the dosimetric effect induced in SNS and helical tomotherapy plans. Methods and Materials: Intrafraction prostate motion data from 486 fractions and 15 patients were available. A motion-encoded dose calculation technique was used to determine the variation of the clinical target volume (CTV) D{sub 95%} values with respect to the static plan for SNS plans. The motion data were analyzed separately, and the correlation coefficients between various motion-based metrics and the dosimetric effect were determined. The dosimetric impact was compared with that incurred during another IMRT technique to assess correlation across different delivery techniques. Results: The mean ({+-}1 standard deviation [SD]) change in D{sub 95%} in the CTV over all 486 fractions was 0.2 {+-} 0.5%. After the delivery of five and 12 fractions, the mean ({+-}1 SD) changes over the 15 patients in CTV D{sub 95%} were 0.0 {+-} 0.2% and 0.1 {+-} 0.2%, respectively. The correlation coefficients between the CTV D{sub 95%} changes and the evaluated motion metrics were, in general, poor and ranged from r = -0.2 to r = -0.39. Dosimetric effects introduced by identical motion in SNS and helical tomotherapy IMRT techniques were poorly correlated with a correlation coefficient of r = 0.32 for the CTV. Conclusions: The dosimetric impact of intrafraction prostate motion on the CTV is, in general, small. In only 4% of all fractions did the dosimetric consequence exceed 1% in the CTV. As expected, the cumulative effect was further reduced with fractionation. The poor correlations between the calculated motion parameters and the subsequent dosimetric effect implies that motion-based thresholds are of limited value in predicting the dosimetric impact of intrafraction motion. The dosimetric effects between the two evaluated delivery techniques were poorly correlated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-242: Volume-Dependence of Quantitative Imaging Features From CT and CE-CT Images of NSCLC

Purpose: To determine whether tumor volume plays a significant role in the values obtained for texture features when they are extracted from computed tomography (CT) images of non-small cell lung cancer (NSCLC). We also sought to identify whether features can be reliably measured at all volumes or if a minimum volume threshold should be recommended. Methods: Eleven features were measured on 40 CT and 32 contrast-enhanced CT (CECT) patient images for this study. Features were selected for their prognostic/diagnostic value in previous publications. Direct correlations between these textures and volume were evaluated using the Spearman correlation coefficient. Any texture that the Wilcoxon rank-sum test was used to compare the variation above and below a volume cutoff. Four different volume thresholds (5, 10, 15, and 20 cm{sup 3}) were tested. Results: Four textures were found to be significantly correlated with volume in both the CT and CE-CT images. These were busyness, coarseness, gray-level nonuniformity, and run-length nonuniformity with correlation coefficients of 0.92, −0.96, 0.94, and 0.98 for the CT images and 0.95, −0.97, 0.98, and 0.98 for the CE-CT images. After volume normalization, the correlation coefficients decreased substantially. For the data obtained from the CT images, the results of the Wilcoxon rank-sum test were significant when volume thresholds of 5–15 cm3 were used. No volume threshold was shown to be significant for the CE-CT data. Conclusion: Equations for four features that have been used in several published studies were found to be volume-dependent. Future studies should consider implementing normalization factors or removing these features entirely to prevent this potential source of redundancy or bias. This work was supported in part by National Cancer Institute grant R03CA178495-01. Xenia Fave is a recipient of the American Association of Physicists in Medicine Graduate Fellowship.

60 APPLIED LIFE SCIENCES↗

Uncertain of uncertainties? A comparison of uncertainty quantification metrics for chemical data sets

Abstract With the increasingly more important role of machine learning (ML) models in chemical research, the need for putting a level of confidence to the model predictions naturally arises. Several methods for obtaining uncertainty estimates have been proposed in recent years but consensus on the evaluation of these have yet to be established and different studies on uncertainties generally uses different metrics to evaluate them. We compare three of the most popular validation metrics (Spearman’s rank correlation coefficient, the negative log likelihood (NLL) and the miscalibration area) to the error-based calibration introduced by Levi et al. ( Sensors 2022 , 22 , 5540). Importantly, metrics such as the negative log likelihood (NLL) and Spearman’s rank correlation coefficient bear little information in themselves. We therefore introduce reference values obtained through errors simulated directly from the uncertainty distribution. The different metrics target different properties and we show how to interpret them, but we generally find the best overall validation to be done based on the error-based calibration plot introduced by Levi et al. Finally, we illustrate the sensitivity of ranking-based methods (e.g. Spearman’s rank correlation coefficient) towards test set design by using the same toy model ferent test sets and obtaining vastly different metrics (0.05 vs. 0.65).

Rasmussen, Maria H.↗

Validation of Normal Tissue Complication Probability Predictions in Individual Patient: Late Rectal Toxicity

Purpose: To perform validation of risk predictions for late rectal toxicity (LRT) in prostate cancer obtained using a new approach to synthesize published normal tissue complication data. Methods and Materials: A published study survey was performed to identify the dose-response relationships for LRT derived from nonoverlapping patient populations. To avoid mixing models based on different symptoms, the emphasis was placed on rectal bleeding. The selected models were used to compute the risk estimates of grade 2+ and grade 3+ LRT for an independent validation cohort composed of 269 prostate cancer patients with known toxicity outcomes. Risk estimates from single studies were combined to produce consolidated risk estimates. An agreement between the actuarial toxicity incidence 3 years after radiation therapy completion and single-study or consolidated risk estimates was evaluated using the concordance correlation coefficient. Goodness of fit for the consolidated risk estimates was assessed using the Hosmer-Lemeshow test. Results: A total of 16 studies of grade 2+ and 5 studies of grade 3+ LRT met the inclusion criteria. The consolidated risk estimates of grade 2+ and 3+ LRT were constructed using 3 studies each. For grade 2+ LRT, the concordance correlation coefficient for the consolidated risk estimates was 0.537 compared with 0.431 for the best-fit single study. For grade 3+ LRT, the concordance correlation coefficient for the consolidated risk estimates was 0.477 compared with 0.448 for the best-fit single study. No evidence was found for a lack of fit for the consolidated risk estimates using the Hosmer-Lemeshow test (P=.531 and P=.397 for grade 2+ and 3+ LRT, respectively). Conclusions: In a large cohort of prostate cancer patients, selected sets of consolidated risk estimates were found to be more accurate predictors of LRT than risk estimates derived from any single study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient Loads Surrogates for Waked Turbines in an Array

Accurately and efficiently predicting wind turbine structural loading is a crucial step in wind farm design. Without considering structural loading, wind farm optimization could negatively impact turbine fatigue and ultimate loads, especially for waked and partially waked turbines, which could result in higher maintenance costs and reduced turbine lifetime. However, predicting turbine loads throughout an array is a costly step, as these quantities require time-accurate results across long time histories, which is often intractable for large array optimization. Therefore, surrogate models that link array spacing to load outputs are often used, but the surrogates are then unique to the inflow conditions and array configurations in the training library. This work develops surrogate models for many wind turbine load outputs based solely on rotor plane velocity measurements, with no required input about array configuration or freestream inflow parameters. Surrogate models were constructed for many turbine quantities of interest (QoI), considering mean, standard deviation, ultimate, and fatigue loads. In general, most QoI statistics were accurately captured, as measured by predicted vs. actual correlation coefficient, confirming the suitability of the approach. Temporal mean values of the QoI required only temporal mean measurements of the rotor plane inflow velocity. However, accurate prediction of temporal standard deviation, ultimate, and fatigue values of QoI also required temporal standard deviations of the rotor plane velocity field. Poor surrogate performance was observed when too many correlated inputs were used, such as multiple velocity components. If the fewest inflow parameters are used to construct the surrogates, the average correlation coefficient value for all output QoI statistics is 0.89. Surrogates for standard deviations and damage equivalent loads (DELs) of turbine QoIs generally had lower accuracy and tower-base and shaft load channels posed the most difficult to capture accurately. The results suggest that these surrogates could be easily paired with analytic wake models, which are frequently used for pre-construction wind farm array optimization, to account for turbine loading in addition to power production. By including the optimal inflow conditions, the surrogate accuracy can improve to an average correlation coefficient value for all output QoI statistics of 0.92. This work has established the ability to build accurate surrogates for mean, standard deviation, ultimate load, and DEL turbine QoI values based on the rotor plane inflow velocity, and identified which inflow conditions lead to greater surrogate accuracy.

17 WIND ENERGY↗

Morphometric Atlas Selection for Automatic Brachial Plexus Segmentation

Purpose: The purpose of this study was to determine the effects of atlas selection based on different morphometric parameters, on the accuracy of automatic brachial plexus (BP) segmentation for radiation therapy planning. The segmentation accuracy was measured by comparing all of the generated automatic segmentations with anatomically validated gold standard atlases developed using cadavers. Methods and Materials: Twelve cadaver computed tomography (CT) atlases (3 males, 9 females; mean age: 73 years) were included in the study. One atlas was selected to serve as a patient, and the other 11 atlases were registered separately onto this “patient” using deformable image registration. This procedure was repeated for every atlas as a patient. Next, the Dice and Jaccard similarity indices and inclusion index were calculated for every registered BP with the original gold standard BP. In parallel, differences in several morphometric parameters that may influence the BP segmentation accuracy were measured for the different atlases. Specific brachial plexus-related CT-visible bony points were used to define the morphometric parameters. Subsequently, correlations between the similarity indices and morphometric parameters were calculated. Results: A clear negative correlation between difference in protraction-retraction distance and the similarity indices was observed (mean Pearson correlation coefficient = −0.546). All of the other investigated Pearson correlation coefficients were weak. Conclusions: Differences in the shoulder protraction-retraction position between the atlas and the patient during planning CT influence the BP autosegmentation accuracy. A greater difference in the protraction-retraction distance between the atlas and the patient reduces the accuracy of the BP automatic segmentation result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detecting outliers in streaming time series data from ARM distributed sensors

The Atmospheric Radiation Measurement (ARM) Data Center at ORNL collects data from a number of permanent and mobile facilities around the globe. The data is then ingested to create high level scientific products. High frequency streaming measurements from sensors and radar instruments at ARM sites require high degree of accuracy to enable rigorous study of atmospheric processes. Outliers in collected data are common due to instrument failure or extreme weather events. Thus, it is critical to identify and flag them. We employed multiple univariate, multivariate and time series techniques for outlier detection methods and studied their effectiveness. First, we examined Pearson correlation coefficient which is used to measure the pairwise correlations between variables. Singular Spectrum Analysis (SSA) was applied to detect outliers by removing the anticipated annual and seasonal cycles from the signal to accentuate anomalies. K-means was applied for multivariate examination of data from collection of sensors to identify any deviation from expected and known patterns and identify abnormal observation. The Pearson correlation coefficient, SSA and K-means methods were later combined together in a framework to detect outliers through a range of checks. We applied the developed method to data from meteorological sensors at ARM Southern Great Plains site and validated against existing database of known data quality issues.

Lu, Yuping↗

Markerless tracking of small lung tumors for stereotactic radiotherapy

Purpose: (1) To validate retrospective markerless tracking software for small lung tumors by comparing tracked motion in 4-dimensional planning computed tomography (4DCT) derived kV projection images and known tumor motion in the same 4DCT. (2) To evaluate variability of tumor motion using kV projection images from cone-beam computed tomography (CBCT) scans acquired on different days. Methods: Nonclinical tumor tracking software (TTS) used a normalized cross correlation algorithm to track the tumor on enhanced kV projection images (e.g., from a CBCT scan). The reference dataset consisted of digitally reconstructed radiographs (DRRs) from one phase of a planning 4DCT. TTS matches two in-plane coordinates and obtains the out-of-plane coordinate by triangulating with match results from other projections. (1) To validate TTS, tracking results were compared with known 4DCT tumor motion for two patients (A and B). Projection images (1 image/1°) were digitally reconstructed for each 4DCT phase. From these, kV projection series were composed simulating full breathing cycles every 20° of gantry rotation [breathing period = 20°/(6°/s) = 3.33 s]. Reference templates were 360 “tumor enhanced” DRRs from the 4DCT expiration phase. TTS-derived tumor motion was compared to known tumor motion on 4DCT. (2) For five patients, TTS-assessed motion during clinical CBCT acquisition was compared with motion on the planning 4DCT, and the motion component in the Y (cranio–caudal)-direction was compared with the motion of an external marker box (RPM, real-time position management). Results: (1) Validation results: TTS for case A (tumor 6.2 cm{sup 3}, 32 mm axial diameter) over 360° showed mean motion X (medial–lateral) = 3.4, Y = 11.5, and Z (ventral–dorsal) = 4.9 mm (1 SD < 1.0 mm). Corresponding 4DCT motion was X = 3.1, Y = 11.3, and Z = 5.1 mm. Correlation coefficients between TTS tumor motion and displacement of the tumor’s center of mass (CoM) on 4DCT were 0.64, 0.96, and 0.82 (X, Y, and Z, respectively). For case B (4.1 cm{sup 3}, 20 mm diameter), due to temporarily decreased tumor visibility preventing TTS from resolving the tumor, robust tracking data were only available between angles 300°–40° and 120°–220°. Mean motion according to TTS was X = 2.0, Y = 7.7, and Z = 8.2 mm (1 SD < 0.9 mm). Tumor motion on 4DCT was X = 1.8, Y = 7.6, and Z = 9.5 mm and correlation coefficients between TTS motion and CoM displacement were 0.59, 0.95, and 0.93 (X, Y, and Z, respectively). (2) Clinical results: TTS revealed a mean intrafraction variation in tumor motion in Y-direction of >2.0 mm (1 SD) in four of five patients. In addition, clinical tumor motion amplitude differed from that seen on planning 4DCT. Internal and external structures that create abrupt density change (e.g., table-top edge, interface between lung/mediastinum and lung/heart) were observed to prevent 360° tracking of the tumor. Correlation coefficients between TTS motion in the Y-direction and the RPM signal (22 observations) ranged from 0.78 to 0.96. In 2D, 241 TTS matches at end-inspiration and end-expiration were visually validated: mean difference was 0.8 mm (SD = 0.7) for both. Conclusions: TTS can track small lung tumors if these are visible in kV projections. A 4DCT dataset can be used to validate kV tracking of moving targets. TTS and 4DCT displacement agreed to within 2 mm. TTS and RPM motion were closely associated but tumor motion during CBCT can vary from the planning 4DCT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-654: Quantifying Plan Quality Can Effectively Distinguish Between Competing Equivocal IMRT Prostate Plans

Purpose: The purpose of this study was to create a prostate IMRT plan quality index (PQI) that may be used to quantitatively compare competing plans using a methodology that mimics physician preference. This methodology allows planners to choose between plans with equivocal characteristics, prior to physician scrutiny. Methods: An observer study was conducted to gather data from 3 radiation oncology physicians who ranked a set of 20 patients (each with 5 plans). The rankings were used to optimize a PQI that combined weighted portions of the rectum, bladder, and planning target volume DVHs, such that the relative PQI mimicked physician rankings as best as possible. Once optimized, a test study assessed the PQI by comparison to physician rankings in a new set of 25 patients (each with 4 plans). The physician group in the test study included 6 physicians, 5 of whom were not included in the modeling study. PQI scores were evaluated against the physicians’ rank list using Spearman rank correlation. Results: The optimized plan quality index combined the following DVH features: high dose regions above 40Gy/60Gy (rectum/bladder), organ weightings, and PTV shoulder coverage. Mean correlation of the PQI vs. physicians’ rankings in the modeling study was 0.507 (range: 0.345–0.706). By comparison, the mean correlation between physicians was 0.301 (range: 0.242–0.334). The mean correlation of the PQI vs. physician rankings in test study was 0.726 (range: 0.416–0.936), indicating robustness of the PQI by virtue of producing similar results to the modeling study. Intra-physician correlation was 0.564 (range: 0.398–0.689). Conclusion: The correlation coefficients of the PQI vs. physicians were similar to the correlation coefficients of the physicians with each other, implying that the PQI developed in this work shows promise in reflecting physician clinical preference when selecting between competing, dosimetrically equivocal plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconciliation of asynchronous satellite-based $\mathrm{NO_2}$ and $\mathrm{XCO_2}$ enhancements with mesoscale modeling over two urban landscapes

Fossil fuel carbon dioxide (CO 2ff ), the main driver of global warming and climate change, is often co-emitted with nitrogen oxides (NO x ) and precursors to ground-level ozone from anthropogenic sources like power plants or vehicles. In urban and suburban areas, satellite-based NO 2 can be used as a proxy to track the emissions of CO 2ff . Because of NO 2 ’s shorter lifetime, urban NO 2 plumes are more distinguishable from backgrounds and more sensitive to variations in emissions. However, the combination of these two gases is limited by the asynchrony among NO 2 and CO 2 monitoring satellites. We used CO 2ff simulated by the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem) model to reconcile the tropospheric NO 2 vertical column density (VCD) from the Tropospheric Monitoring Instrument (TROPOMI) and column-averaged dry-air mole fractions of carbon dioxide enhancements (ΔXCO 2 ) from Orbiting Carbon Observatory 3 (OCO-3) Snapshot Area Maps (SAMs) over a multicity area, Washington D.C.-Baltimore (DC-Balt), and a basin city, Mexico City. NO 2 /CO 2ff ratios over DC-Balt are smaller than Mexico City, indicative of stricter emission restrictions, a more combustion-efficient vehicle fleet, and higher combustion efficiency due to lower altitude in DC-Balt. For single-track cases, the spatial correlations between NO 2 and ΔXCO 2 over Mexico City are stronger than DC-Balt because the NO 2 and CO 2 are mostly trapped in the valley of Mexico City, while DC-Balt is severely affected by distant sources (i.e., US East Coast cities). Using multi-track averaging, spatial correlation coefficients increase with the number of days used for averaging. The correlations reached a maximum when averaging >12 continuous images for DC-Balt and > 10 continuous images for Mexico City. This finding indicates that multi-track averaging using modeled CO 2ff as a proxy is helpful to filter the noise in single-track images, to cancel the interference from distant sources, and to magnify correlations between NO 2 and CO 2ff . Mexico City showed stronger spatial correlations but weaker temporal correlations than DC-Balt due to biomass burning hot spots and large transport errors caused by the trapping effects of the surrounding mountains. Tracking the 20-day moving average of CO 2ff emissions using TROPOMI NO 2 seems technically feasible, considering the relationship between correlation coefficients and the number of available satellite images.

54 ENVIRONMENTAL SCIENCES↗

Combined 3D-QSAR, molecular docking and molecular dynamics study on thyroid hormone activity of hydroxylated polybrominated diphenyl ethers to thyroid receptors β

Several recent reports suggested that hydroxylated polybrominated diphenyl ethers (HO-PBDEs) may disturb thyroid hormone homeostasis. To illuminate the structural features for thyroid hormone activity of HO-PBDEs and the binding mode between HO-PBDEs and thyroid hormone receptor (TR), the hormone activity of a series of HO-PBDEs to thyroid receptors β was studied based on the combination of 3D-QSAR, molecular docking, and molecular dynamics (MD) methods. The ligand- and receptor-based 3D-QSAR models were obtained using Comparative Molecular Similarity Index Analysis (CoMSIA) method. The optimum CoMSIA model with region focusing yielded satisfactory statistical results: leave-one-out cross-validation correlation coefficient (q{sup 2}) was 0.571 and non-cross-validation correlation coefficient (r{sup 2}) was 0.951. Furthermore, the results of internal validation such as bootstrapping, leave-many-out cross-validation, and progressive scrambling as well as external validation indicated the rationality and good predictive ability of the best model. In addition, molecular docking elucidated the conformations of compounds and key amino acid residues at the docking pocket, MD simulation further determined the binding process and validated the rationality of docking results. -- Highlights: ► The thyroid hormone activities of HO-PBDEs were studied by 3D-QSAR. ► The binding modes between HO-PBDEs and TRβ were explored. ► 3D-QSAR, molecular docking, and molecular dynamics (MD) methods were performed.

60 APPLIED LIFE SCIENCES↗