Optimized Heat Interception for Cryogen Tank Support Structure

We consider means for using the cooling available in boil-off gas to intercept heat conducted through the support structure of a cryogen tank. A one-dimensional model of the structure coupled to a gas stream gives an analytical expression for heat leak in terms of flow rate for temperature independent properties and laminar flow. A numerical model has been developed for heat transfer on a thin cylindrical tube with an attached vent line. The model is used to determine the vent path layout that will minimize heat flow into the cryogen tank. The results are useful for a number of applications, but the one of interest in this study is the minimization of the boil-off in large cryopropellant tanks in low Earth and low lunar orbit.

Canavan, E. R.↗

Optimized Heat Interception for Cryogen Tank Support

We consider means for using the cooling available in boil-off gas to intercept heat conducted through the support structure of a cryogen tank. A one-dimensional model of the structure coupled to a gas stream gives an analytical expression for heat leak in terms of flow rate for temperature independent-properties and laminar flow. A numerical model has been developed for heat transfer on a thin cylindrical tube with an attached vent line. The model is used to determine the vent path layout that will minimize heat flow into the cryogen tank. The results are useful for a number of applications, but the one of interest in this study is the minimization of the boil-off in large cryopropellant tanks in low Earth and low lunar orbit.

Canavan, Edgar R.↗

Cryogenic energy storage: Standalone design, rigorous optimization and techno-economic analysis

Energy storage allows flexible use and management of excess electricity and intermittently available renewable energy. Cryogenic energy storage (CES) is a promising storage alternative with a high technology readiness level and maturity, but the round-trip efficiency is often moderate and the Levelized Cost of Storage (LCOS) remains high. The complex flowsheets with intricate thermodynamics at cryogenic temperatures as well as the presence of multiple loops and refrigeration cycles pose considerable challenges for rigorous model-based design and optimization of CES systems. We present an optimization strategy that couples rigorous process simulation and Bayesian optimization with flowsheet decomposition and identification of hidden coupling constraints to optimally design standalone CES systems. Further refinement is done via a local search using the limited-memory Broyden–Fletcher–Goldfarb–Shanno algorithm. Here our results indicate that it is possible to achieve more than 52% round-trip efficiency and an LCOS of $153/MWh for a standalone 100 MW/400 MWh CES system limited to short-term storage with daily charging–discharging. However, a detailed techno-economic assessment reveals that the LCOS considering total capital investment may exceed $267/MWh when all direct and indirect costs of installation and operation are considered.

25 ENERGY STORAGE↗

Problem of selecting optimal regimes for storage of cryogenic agents

A thermodynamic analysis is given of different regimes of storage of hydrogen, nitrogen, oxygen, and argon using the high vacuum of space. Optimal regimes are determined from the standpoint of minimizing weight characteristics. Several unique storage regimes are proposed.

Mikhalchenko, R. S.↗

Infrared readout electronics; Proceedings of the Meeting, Orlando, FL, Apr. 21, 22, 1992

The present volume on IR readout electronics discusses cryogenic readout using silicon devices, cryogenic readout using III-V and LTS devices, multiplexers for higher temperatures, and focal-plane signal processing electronics. Attention is given to the optimization of cryogenic CMOS processes for sub-10-K applications, cryogenic measurements of aerojet GaAs n-JFETs, inP-based heterostructure device technology for ultracold readout applications, and a three-terminal semiconductor-superconductor transimpedance amplifier. Topics addressed include unfulfilled needs in IR astronomy focal-plane readout electronics, IR readout integrated circuit technology for tactical missile systems, and radiation-hardened 10-bit A/D for FPA signal processing. Also discussed are the implementation of a noise reduction circuit for spaceflight IR spectrometers, a real-time processor for staring receivers, and a fiber-optic link design for INMOS transputers.

Fossum, Eric R.↗

Cryogenic Durability of a Carbon Fiber Reinforced Cyanate Ester Composite: Degree-of-Cure Effect

The James Webb Space Telescope (JWST) will be located approximately 1.5 million kilometers from Earth, producing extremely cold temperatures on the optical portion of the observatory. Specifically, the Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) will operate at approximately -240 C. Construction of the structural components of the OTE and ISIM require bonding dissimilar materials together, e.g. Invar-36 (an iron-nickel alloy) to a carbon fiber reinforced cyanate ester composite (CFRCE) with an epoxy adhesive. While these materials enable the cryogenic stability required for optical performance, their joint strength at these extreme conditions presents a unique design challenge. Therefore, the current study presents a detailed investigation into the optimization of cryogenic composite durability. It is demonstrated that by controlling the degree-of-cure of a laminate, one can achieve an enhanced resistance to microcracking and an improved residual strength following cryogenic cycling to -253 C.

Polis, Daniel L.↗

A Cryogenic GaAs PHEMT/ Ferroelectric Ku-Band Tunable Oscillator

A Ku-band tunable oscillator operated at and below 77 K is described. The oscillator is based on two separate technologies: a 0.25 mm GaAs pseudomorphic high electron mobility transistor (PHEMT) circuit optimized for cryogenic operation, and a gold microstrip ring resonator patterned on a thin ferroelectric (SrTiO3) film which was laser ablated onto a LaAlO3 substrate. A tuning range of up to 3% of the center frequency was achieved by applying dc bias between the ring resonator and ground plane. To the best of our knowledge, this is the first tunable oscillator based on a thin film ferroelectric structure demonstrated in the microwave frequency range. The design methodology of the oscillator and the performance characteristics of the tunable resonator are described.

Romanofsky, Robert R.↗

On-wafer, cryogenic characterization of ultra-low noise HEMT devices

Significant advances in the development of high electron-mobility field-effect transistors (HEMT's) have resulted in cryogenic, low-noise amplifiers (LNA's) whose noise temperatures are within an order of magnitude of the quantum noise limit (hf/k). Further advances in HEMT technology at cryogenic temperatures may eventually lead to the replacement of maser and superconducting insulator superconducting front ends in the 1- to 100-GHz frequency band. Key to identification of the best HEMT's and optimization of cryogenic LNA's are accurate and repeatable device measurements at cryogenic temperatures. This article describes the design and operation of a cryogenic coplanar waveguide probe system for the characterization and modeling of advanced semiconductor transistors at cryogenic temperatures. Results on advanced HEMT devices are presented to illustrate the utility of the measurement system.

Bautista, J. J.↗

Multi-objective optimization of CEBAF heat load management and trip rates using AI/ML

The goal of this project is to investigate the use of RL to simultaneously optimize the cryogenic heat load and trip rate of the CEBAF linacs and make it generic to solve multi-objective problems that will enable its application at other Department of Energy (DOE) facilities with similar challenges. The existing approach optimizes the gradient distribution to minimize the trip rate and does not take into account the total heat load. A secondary objective of the project is the develop a framework to correct cavity quality curves (Q-curves) or RF-heat to Gradient relation curves for individual cavities. These curves are currently obtained using historical measurements and may have changed their behavior due to various events. Correction in these curves will allow us to accurately approximate the total RF heat generated by the linacs which is critical for the optimization.

43 PARTICLE ACCELERATORS↗

Innovative, High-Pressure, Cryogenic Control Valve: Short Face-to-Face, Reduced Cost

A control valve that can throttle high-pressure cryogenic fluid embodies several design features that distinguish it over conventional valves designed for similar applications. Field and design engineers worked together to create a valve that would simplify installation, trim changes, and maintenance, thus reducing overall cost. The seals and plug stem packing were designed to perform optimally in cryogenic temperature ranges. Unlike conventional high-pressure cryogenic valves, the trim size can be changed independent of the body. The design feature that provides flexibility for changing the trim is a split body. The body is divided into an upper and a lower section with the seat ring sandwiched in between. In order to maintain the plug stem packing at an acceptable sealing temperature during cryogenic service, heat-exchanging fins were added to the upper body section. The body is made of stainless steel. The seat ring is made of a nickel-based alloy having a coefficient of thermal expansion less than that of the body material. Consequently, when the interior of the valve is cooled cryogenically, the body surrounding the seat ring contracts more than the seat ring. This feature prevents external leakage at the body-seat joint. The seat ring has been machined to have small, raised-face sealing surfaces on both sides of the seal groove. These sealing surfaces concentrate the body bolt load over a small area, thereby preventing external leakage. The design of the body bolt circle is different from that of conventional highpressure control valves. Half of the bolts clamp the split body together from the top, and half from the bottom side. This bolt-circle design allows a short, clean flow path, which minimizes frictional flow losses. This bolt-circle design also makes it possible to shorten the face-toface length of the valve, which is 25.5 in. (65 cm). In contrast, a conventional, high-pressure control valve face-to-face dimension may be greater than 40 in. (>1 m) long.

Source record↗

Innovative, High-Pressure, Cryogenic Control Valve: Short Face-to-Face, Reduced Cost

A control valve that can throttle high pressure cryogenic fluid embodies several design features that distinguish it over conventional valves designed for similar applications. Field and design engineers worked together to create a valve that would simplify installation, trim changes, and maintenance, thus reducing overall cost. The seals and plug stem packing were designed to perform optimally in cryogenic temperature ranges. Unlike conventional high-pressure cryogenic valves, the trim size can be changed independent of the body. The design feature that provides flexibility for changing the trim is a split body. The body is divided into an upper and a lower section with the seat ring sandwiched in between. In order to maintain the plug stem packing at an acceptable sealing temperature during cryogenic service, heat-exchanging fins were added to the upper body section (see figure). The body is made of stainless steel.

Wilkes, Karlin↗

Innovative, High-Pressure, Cryogenic Control Valve: Short Face-to-Face, Reduced Cost

A control valve that can throttle high-pressure cryogenic fluid embodies several design features that distinguish it over conventional valves designed for similar applications. Field and design engineers worked together to create a valve that would simplify installation, trim changes, and maintenance, thus reducing overall cost. The seals and plug stem packing were designed to perform optimally in cryogenic temperature ranges. Unlike conventional high-pressure cryogenic valves, the trim size can be changed independent of the body.

Wilkes, Karlin↗

Piezoresistive silicon pressure sensors in cryogenic environment

This paper presents data on low-temperature measurements of silicon pressure sensors. It was found that both the piezoresistance coefficients and the charge-carrier mobility increase with decreasing temperature. For lightly doped semiconductor materials, the density of free charge carriers decreases with temperature and can freeze out eventually. However, the effect of carrier freeze-out can be minimized by increasing the impurity content to higher levels, at which the temperature dependency of piezoresistance coefficients is reduced. An impurity density of 1 x 10 to the 19th/cu cm was found to be optimal for cryogenic applications of pressure sensor dies.

Kahng, Seun K.↗

Analysis and Validation of PMT s Waveforms in ICARUS LArTPC Using Monte Carlo Simulations

ICARUS (Imaging Cosmic and Rare Underground Signals) serves as the Far Detector in the Short Baseline Neutrino (SBN) program at Fermilab, playing a central role in investigating the potential existence of sterile neutrinos in the eV squared mass range. The detector consists of two large Liquid Argon Time Projection Chambers (LArTPCs) with a total capacity of 760 tons of liquid Argon. A key component of the system is its array of 360 Photo-Multiplier Tubes (PMTs), which detect the scintillation light produced by charged particles in liquid Argon; the fast scintillation signal enables accurate event timing, triggering, and reconstruction. Together with the TPC and CRT systems, the PMTs ensure precise interaction time measurements, which are crucial for distinguishing neutrino interactions from cosmic-ray backgrounds. ICARUS uses Hamamatsu R5912-MOD PMTs, optimized for cryogenic temperatures, with high quantum efficiency, excellent timing resolution, low dark current (around 10 nA at 1500 V), and broad spectral sensitivity (300–650 nm). These characteristics are crucial for the efficient detection of scintillation light. Analyzing the waveforms of PMT signals allows for a detailed comparison between experimental data and Monte Carlo simulations. This analysis is fundamental for improving the accuracy of neutrino event reconstruction, enhancing detector calibration, and optimizing the detector's performance for current and future operations.

Brio, V. [Catania U.] (ORCID:0009000088807391)↗

Commissioning and first operation of the low-beta triplets and their electrical feed boxes at the Large Hadron Collider

The insertion regions located around the four interaction points of the Large Hadron Collider (LHC) are mainly composed of the low-{beta} triplets, the separation dipoles and their respective electrical feed-boxes (DFBX). The low-{beta} triplets are Nb-Ti superconductor quadrupole magnets, which operate at 215 T/m in superfluid helium at a temperature of 1.9 K. The commissioning and the first operation of these components have been performed. The thermo-mechanical behavior of the low-{beta} triplets and DFBX were studied. Cooling and control systems were tuned to optimize the cryogenic operation of the insertion regions. Hardware commissioning also permitted to test the system response. This paper summarizes the performance results and the lessons learned.

43 PARTICLE ACCELERATORS↗

Better Than Worst-Case Decoding for Quantum Error Correction

The overheads of classical decoding for quantum error correction in cryogenic quantum systems grow rapidly with the number of logical qubits and their correction code distance. Decoding at room temperature is bottlenecked by refrigerator I/O bandwidth while cryogenic on-chip decoding is limited by area/power/thermal budget. To overcome these overheads, we are motivated by the observation that in the common case (over 90% of the time), error correction 'syndromes' are fairly trivial with high redundancy / sparsity, since the error correction codes are over-provisioned to be able to correct for uncommon worst-case complex scenarios (to ensure substantially low logical error rates). If suitably exploited, these trivial scenarios can be handled with insignificant overhead, thereby alleviating any bottlenecks towards handling the worst-case scenarios by state-of-the-art means. Here, we propose Better Than Worst-Case Decoding for Quantum Error Correction, targeting cryogenic quantum systems and Surface Code, consisting of: On-chip Clique Decoder: An extremely lightweight decoder for correcting trivial common-case errors, designed for the cryogenic domain. The decoder is implemented and evaluated for SFQ logic. Statistical Off-chip Bandwidth Allocation: A statistical confidence-based technique for allocation of off-chip decoding bandwidth, to efficiently handle the rare complex decodes that are not covered by the Clique Decoder. Decode-Overflow Execution Stalling: A method to stall circuit execution, for the worst-case scenarios in which the provisioned off-chip bandwidth is insufficient to complete all requested off-chip decodes. In all, BTWC decoding achieves 70-99+% off-chip bandwidth elimination across a range of logical and physical error rates, without significantly sacrificing the accuracy of a state-of-the-art off-chip decoder. Further, it achieves 10-1000x bandwidth reduction over prior bandwidth reduction techniques, as well as 15-37x resource overhead reduction compared to prior on-chip decoding.

cryogenic optimization↗

Progress in the development of integrating JFET amplifiers

A new approach to infrared detector readout has appeared with the development of integrating JFET amplifiers. This brief progress report includes results on the operation of commercially available devices at a temperature of 40 K, on their sensitivity and on an effort to develop a new JFET with properties optimized for cryogenic applications. Even with presently available devices it will be shown that for applications such as the Space Infrared Telescope Facility (SIRTF), the most strigent sensitivity requirements of noise currents as low as 1 electron/sec in less than 100 seconds of integration can be met.

Low, F. J.↗

Temperature effects on the deformation and fracture of Al-Li-Cu-In alloys

The crack initiation and growth fracture resistance of Al-Cu-Li and Al-Cu-Li-In alloys were characterized and optimized for cryogenic tank applications. Presently, the effects of stress state and temperature is being determined on the fracture toughness and fracture mechanisms of commercially available Vintage 3 2090-T81 and experimental 2090+In-T6. Precracked J-integral specimens of both alloys were tested at ambient and cryogenic temperatures in the plane stress and plane strain conditions. Considering ambient temperature, results showed that 2090-T81 exhibited the highest toughness in both plane strain and plane stress conditions. For the plane strain condition, reasonable crack initiation and growth toughness of 1090-T81 are associated with a significant amount of delamination and transgranular fracture. Plane stress toughnesses were higher and fracture was characterized by shear cracking with minimal delaminations. In comparisons, the fracture behavior of 2090+In-T6 is significantly degraded by subgrain boundary precipitation. Toughness is low and characterized by intersubgranular fracture with no delamination in the plane stress or plane strain conditions. Intersubgranular cracking is a low energy event which presumably occurs prior to the onset of slip band cracking. Copious grain boundary precipitation is atypical of commercially available 2090. At cryogenic temperatures, both alloys exhibit increased yield strength, toughness, and amount of delamination and shear cracking. The change in fracture mode of 2090+In-T6 from intersubgranular cracking at ambient temperature to a combination of intersubgranular cracking, shear cracking, and delamination at cryogenic temperature is the subject of further investigation.