Search NASA⌕ Search

SEARCH · Search NASA

Results for “differential capacitance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ferro-ionic states and domains morphology in Hf x Zr 1–x O 2 nanoparticles

Unique polar properties of nanoscale hafnia-zirconia oxides (Hf x Zr 1–x O 2 ) are of great interest for condensed matter physics, nanophysics, and advanced applications. These properties are connected (at least partially) to the ionic–electronic and electrochemical phenomena at the surface, interfaces, and/or internal grain boundaries. Here, we calculated the phase diagrams, dielectric permittivity, spontaneous polar, and antipolar ordering, as well as the domain structure morphology in Hf x Zr 1–x O 2 nanoparticles covered by ionic–electronic charge originating from surface electrochemical adsorption. We revealed that the ferro-ionic coupling supports the polar long-range order in nanoscale Hf x Zr 1–x O 2 , induces, and/or enlarges the stability region of the labyrinthine domains toward smaller sizes and smaller environmental dielectric constant at low concentrations of the surface ions. The ferro-ionic coupling causes the transition to the single-domain ferro-ionic state at high concentrations of the surface ions. We predict that the labyrinthine domain states, being multiple-degenerated, may significantly affect the emergence of the negative differential capacitance state in the nanograined/nanocrystalline Hf x Zr 1–x O 2 films.

36 MATERIALS SCIENCE↗

Structure, dynamics, and electrochemistry of choline chloride/ethylene glycol eutectic solvents at an electrode surface explored by molecular dynamics simulations

Choline chloride and ethylene glycol mixtures with 1:2, 1:4, and 1:6 molar ratios on the surfaces of graphite and gold electrodes were studied using classical molecular dynamics simulations. Both neutral and charged electrodes were considered. The liquid composition, solvation structure, molecular orientation, and dynamics at the electrode surface are significantly different from those of the bulk liquid. These properties strongly depend on the electrode material and charge density, whereas they are less sensitive to the overall solvent composition. The effect of the electrode on the composition, structure, and orientation of the liquid fades beyond ∼10 Å from the surface of the electrode. This distance corresponds to about two layers of the structured solvent, despite the fact that the layered structure extends to at least five layers or about 25 Å. However, the electrode influences solvent dynamics over a longer distance. The electrochemical properties of the eutectic solvent at both electrode surfaces were also studied. The simulations captured the experimental differential capacitance shapes for both electrode systems, although the magnitudes and exact shapes differ. The simulations further revealed that the solvent in the first solvation layer can both overscreen and underscreen the electrode charges depending on the electrode material and electrode potential.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deriving effective electrode–ion interactions from free-energy profiles at electrochemical interfaces

Understanding ion adsorption at electrified metal–electrolyte interfaces is essential for accurate modeling of electrochemical systems. Here, in this study, we systematically investigate the free energy profiles of Na + , Cl − , and F − ions at the Au(111)–water interface using enhanced sampling molecular dynamics with both classical force fields and machine-learned interatomic potentials (MLIPs). Our classical metadynamics results reveal a strong dependence of predicted ion adsorption on the Lennard-Jones parameters, highlighting that—without due care—standard mixing rules can lead to qualitatively incorrect descriptions of ion–metal interactions. We present a systematic methodology for tuning the cross term LJ parameters to control adsorption energetics in agreement with more accurate models. As a surrogate for an ab initio model, we employed the recently released Universal Models for Atoms MLIP, which validates classical trends and displays strong specific adsorption for chloride, weak adsorption for fluoride, and no specific adsorption for sodium, in agreement with experimental and theoretical expectations. By integrating molecular-level adsorption free energies into continuum models of the electric double layer, we show that specific ion adsorption substantially alters the interfacial ion population, the potential of zero charge, and the differential capacitance of the system. Our results underscore the critical importance of force field parameterization and advanced interatomic potentials for the predictive modeling of ion-specific effects at electrified interfaces and provide a robust framework for bridging molecular simulations and continuum electrochemical models.

Roncoroni, Fabrice [Lawrence Berkeley National Lab↗

A MEMS dynamic mechanical analyzer for in situ viscoelastic characterization of 3D printed nanostructures

Cellular metamaterial structures with sub-micron features have shown the ability to become excellent energy absorbing materials for impact mitigation due to the enhanced mechanical properties of materials at the nanoscale. However, in order to optimize the design of these energy absorbing metamaterial structures we need to be able to measure the dynamic properties of the sub-micron features such as storage and loss moduli and the loss factor. Therefore, at scale testing is required to capture the scale, temperature, and strain rate dependent material properties of these nanoscale materials. This study presents the design, fabrication, and calibration of a MEMS-based dynamic mechanical analyzer (DMA) that can be directly integrated with the two photon lithography (TPL) process commonly used to fabricate metamaterial structures with nanoscale features. The MEMS-based DMA consists of a chevron style thermal actuator used to generate a tensile load on the structure and two differential capacitive sensors on each side of the structure used to measure load and displacement. This design demonstrated 1.5 ± 0.75 nm displacement resolution and 104 ± 52 nN load resolution, respectively. Dynamic mechanical analysis was successfully conducted on a single nanowire feature printed between the load and displacement stages of the MEMS device with testing frequencies ranging between 0.01–10 Hz and testing temperatures ranging between 22 °C–47 °C. These initial tests on an exemplar TPL part demonstrate that the printed nanowire behaves as a viscoelastic material wherein the transition from glassy to viscous behavior has already set in at the room temperature.

42 ENGINEERING↗

Simulation of the effective concentration profiles in InGaAs/GaAs heterostructures containing δ-doped layers

InGaAs/GaAs heterostructures containing quantum wells and δ-doped layers are studied theoretically and experimentally. On the basis of the procedure of self-consistently solving the Schrödinger equation and Poisson equation, the differential capacitance and the apparent electron concentration profiles are numerically calculated for structures with different mutual arrangements of the quantum well and the δ layer. The results of the calculations are compared with the result of analyzing the experimental capacitance-voltage characteristics of the structures. The systematic features of the behavior of the apparent concentration profiles and capacitance-voltage characteristics in relation to the geometric properties of the structure, the temperature, and the doping level are established.

36 MATERIALS SCIENCE↗

Increase in the Shockley–Read–Hall recombination rate in InGaN/GaN QWs as the main mechanism of the efficiency droop in LEDs at high injection levels

It is shown that the efficiency droop observed as the current through a GaN-based light-emitting diode increases is due to a decrease in the Shockley–Read–Hall nonradiative lifetime. The lifetime decreases with increasing current because a steadily growing number of traps in the density-of-states tails of InGaN/GaN quantum wells become nonradiative recombination centers upon the approach of quasi-Fermi levels to the band edges. This follows from the correlation between the efficiency droop and the appearance of negative differential capacitance, observed in the study. The correlation appears due to slow trap recharging via the trap-assisted tunneling of electrons through the n-type barrier of the quantum well and to the inductive nature of the diode-current variation with forward bias.

36 MATERIALS SCIENCE↗

Electroresponse of weak polyelectrolyte brushes

Abstract End-tethered polyelectrolytes are widely used to modify substrate properties, particularly for lubrication or wetting. External stimuli, such as pH, salt concentration, or an electric field, can induce profound structural responses in weak polyelectrolyte brushes, which can be utilized to further tune substrate properties. We study the structure and electroresponsiveness of weak polyacid brushes using an inhomogeneous theory that incorporates both electrostatic and chain connectivity correlations at the Debye–Hückel level. Our calculation shows that a weak polyacid brush swells under the application of a negative applied potential, in agreement with recent experimental observation. We rationalize this behavior using a scaling argument that accounts for the effect of the surface charge. We also show that the swelling behavior has a direct influence on the differential capacitance, which can be modulated by the solvent quality, pH, and salt concentration. Graphical Abstract

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlation of photocurrent-voltage curves with flat-band potential for stable photoelectrodes for the photoelectrolysis of water

Using the differential capacitance technique, the flat-band potential of n-type TiO2, SnO2, SrTiO3, KTaO3, and KTa(0.77)Nb(0.23)O3 electrodes has been determined as a function of pH in aqueous electrolytes. Plots of flat-band potential vs. pH are linear in all cases and have a slope of approximately 0.059 V/pH unit. The flat-band potential correlates nicely with the onset for photoanodic currents corresponding to O2 evolution at the n-type semiconductor and H2 at the dark Pt cathode. The ordering of flat-band potentials at a given pH is SrTiO3 of the order of KTaO3 of the order of KTa(0.77)Nb(0.23)O3 greater than TiO2 greater than SnO2 (SnO2 most positive vs a saturated calomel electrode).

Bolts, J. M.↗

Two-degree-of-freedom image motion compensator for Shuttle-based pointing experiments

The mechanical design of the subarcsec-accurate, high-bandwidth two-DOF image motion compensator developed to enhance Space Shuttle-based optical telescope experiments' pointing accuracy encompasses a gimbal-type flex-pivot suspension, a novel ironless two-axis forcer, and a differential capacitive tilt-sensor system. The image motion compensator was developed to allow the UV Imaging Telescope Sensor to maintain stringent pointing accuracies over extended integration intervals while experiencing typical manned spacecraft perturbations.

Schuster, Ludwig E.↗

Surface Micro-Machining: Progress Towards Micro-Electro Mechanical Systems

Surface micromachining is a technique for building electromechanical systems in silicon. A number of electromechanical systems have been implemented in miniature using the fundamental structural building blocks of tensile and non-tensile springs, differential capacitance sensing cells, and electrostatic drive. The integration of complicated mechanical structures and electrical circuits onto a single chip is expected to improve reliability and testability of systems. Reduction in interconnect wiring, the increased use of automation, and the inherent reliability of integrated circuits will all contribute to increased reliability of systems.

Doscher, James↗

Differential voltage amplification from ferroelectric negative capacitance

Here, we demonstrate that a ferroelectric can cause a differential voltage amplification without needing an external energy source. As the ferroelectric switches from one polarization state to the other, a transfer of energy takes place from the ferroelectric to the dielectric, determined by the ratio of their capacitances, which, in turn, leads to the differential amplification. This amplification is very different in nature from conventional inductor-capacitor based circuits where an oscillatory amplification can be observed. The demonstration of differential voltage amplification from completely passive capacitor elements only has fundamental ramifications for next generation electronics.

42 ENGINEERING↗

Analysis of differential and active charging phenomena on ATS-5 and ATS-6

Spacecraft charging on the differential charging and artificial particle emission experiments on ATS 5 and ATS 6 were studied. Differential charging of spacecraft surfaces generated large electrostatic barriers to spacecraft generated electrons, from photoemission, secondary emission, and thermal emitters. The electron emitter could partially or totally discharge the satellite, but the mainframe recharged negatively in a few 10's of seconds. The time dependence of the charging behavior was explained by the relatively large capacitance for differential charging in comparison to the small spacecraft to space capacitance. A daylight charging event on ATS 6 was shown to have a charging behavior suggesting the dominance of differential charging on the absolute potential of the mainframe. Ion engine operations and plasma emission experiments on ATS 6 were shown to be an effective means of controlling the spacecraft potential in eclipse and sunlight. Elimination of barrier effects around the detectors and improving the quality of the particle data are discussed.

Olsen, R. C.↗

Strain Gage Measurement System to Determine Cryogenic Propellant Tank Level

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult proposition. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. This paper describes a simple, but effective method to determine propellant volume by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a very good quality signal even during pressurization.

Figueroa, Fernando↗

Fiber-Optic Strain-Gage Tank Level Measurement System for Cryogenic Propellants

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult problem. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. These methods are designed to measure tank-level, but when the fluids are in supercritical state, the liquid-gas interface disappears. Furthermore, there is a need for a non-intrusive measurement system; that is, the sensors should not require tank modifications and/or disturb the fluids. This paper describes a simple, but effective method to determine propellant mass by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a much better quality signal across all regimes during an engine test. Experimental results also show that the use of fiber optic strain gages (FOSG) over classic foil strain gages extends the operation time (before the system becomes uncalibrated), and increases accuracy. Finally, a procedure is defined whereby measurements from the FOSG mounted on the tank supporting structure are compensated using measurements of a FOSG mounted on a reference plate and temperature measurements of the structure. Results describing the performance of a deployed system that measures tank level during propulsion tests are included.

Figueroa, Fernando↗

Mechanistic Insights of Pore Contributions in Carbon Supercapacitors by Modified Step Potential Electrochemical Spectroscopy

Porous carbons are widely used as electrode materials for electrical double layer (EDL)-type supercapacitors. Differentiation of capacitance contributions from micropores and mesopores is important to understand porous carbon capacitive behavior. However, this remains challenging to accomplish. Here, we present an improved step potential electrochemical spectroscopy method to investigate the contributions to capacitance from hierarchical pores and redox processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Publisher's Note: “Differential voltage amplification from ferroelectric negative capacitance” [Appl. Phys. Lett. 111, 253501 (2017)]

This article was originally published online on 18 December 2017. Due to a production error, the initially-published version contained several typographical errors not corrected during proof revisions, none of which affected the substance of the article. AIP Publishing apologizes for this error. All online versions of the article were corrected on 21 December 2017, and it now appears correctly in print.

99 GENERAL AND MISCELLANEOUS↗

Capacitance multiplier and filter synthesizing network

A circuit using a differential amplifier multiplies the capacitance of a discrete interating capacitor by (r sub 1 + R sub 2)/R sub 2, where R sub 1 and R sub 2 are values of discrete resistor coupling an input signal e sub 1 of the amplifier inputs. The output e sub 0 of the amplifier is fed back and added to the signal coupled by the resistor R sub 2 to the amplifier through a resistor of value R sub 1. A discrete resistor R sub x may be connected in series for a lag filter, and a discrete resistor may be connected in series with the capacitor for a lead-lag filter. Voltage dividing resistors R sub a and R sub b may be included in the feedback circuit of the amplifier output e sub o to independently adjust the circuit gain e sub i/e sub o.

Kline, A. J.↗

Distributed Capacitive Sensor for Sample Mass Measurement

Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

Toda, Risaku↗