Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hand-Held Ultrasonic Instrument for Reading Matrix Symbols

A hand-held instrument that would include an ultrasonic camera has been proposed as an efficient means of reading matrix symbols. The proposed instrument could be operated without mechanical raster scanning. All electronic functions from excitation of ultrasonic pulses through final digital processing for decoding matrix symbols would be performed by dedicated circuitry within the single, compact instrument housing.

Schramm, Harry F.↗

Investigation of the neutron response anisotropy in crystalline organic scintillators.

An anisotropy in the response of crystalline organic scintillators such as anthracene to neutron elastic scattering interactions has been known for some time. Both the amplitude and the time structure of the scintillation light pulse vary with the direction of the proton recoil with respect to the crystalline axes. In principle, this effect could be exploited to develop compact, high-efficiency fast neutron detectors that have directional sensitivity via a precise measurement of the pulse shape. We are investigating the feasibility and sensitivity of such a detector, particularly for neutrons in the fission energy spectrum. Here we will report new measurements of the pulse shape dependence on proton recoil angle in anthracene and stilbene single crystals, for proton energies in the few MeV range. Digital pulse acquisition and processing are used to allow an exploration of different pulse shape analysis techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Digital filtering and acceleration pulse interpretation

It was concluded that the post processing digital filter is quite effective for removing unwanted high frequency and noise without distorting the signal. In addition, digital filtering is effective for smoothing low-level low resolution digital data where the digital stairstep phenomena are pronounced. Integrating the acceleration data to obtain velocity traces is quite useful. The velocity change provides a check on the validity of the acceleration trace. (Zero offsets in acceleration must be removed before integrating.) Average accelerations can be obtained from the velocity trace by dividing the change in velocity for an acceleration pulse by the pulse duration. One can obtain the peak of an equivalent triangular pulse by doubling the average acceleration.

Pasanella, E. L.↗

Droplet field visualization and characterization via digital image analysis

This paper describes techniques that have been developed at JPL for visualization and measurements of droplet fields in a moving airstream. The techniques have been applied to a variety of problems which include simulation of heavy rain conditions in a wind tunnel, engine ingestion of wheel spray, analysis of fuel nozzle sprays and aerodynamic breakup of non-Newtonian liquids. The approach pursued here is direct imaging using a pulsed laser illumination source, followed by digital processing of photographic images. A laser double pulse technique has been used for determination of droplet velocities. Laser induced fluorescence has been used to enhance droplet definition in photographic images. The image processing software developed is capable of distinguishing between out-of-focus and in-focus drops, retaining only the latter for size determination.

Hernan, M. A.↗

Gamma ray spectroscopy employing divalent europium-doped alkaline earth halides and digital readout for accurate histogramming

A scintillator radiation detector system according to one embodiment includes a scintillator; and a processing device for processing pulse traces corresponding to light pulses from the scintillator, wherein pulse digitization is used to improve energy resolution of the system. A scintillator radiation detector system according to another embodiment includes a processing device for fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times and performing a direct integration of fit parameters. A method according to yet another embodiment includes processing pulse traces corresponding to light pulses from a scintillator, wherein pulse digitization is used to improve energy resolution of the system. A method in a further embodiment includes fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times; and performing a direct integration of fit parameters. Additional systems and methods are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Applying the new gamma ray imager diagnostic to measurements of runaway electron Bremsstrahlung radiation in the DIII-D Tokamak (invited)

A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5–100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead “pinhole camera” mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New developments in structure-property and amorphous materials research at the upgraded 16-BM-B Paris-Edinburgh press station at HPCAT

Beamline 16-BM-B of the High-Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source (APS) provides a Paris-Edinburgh press program to probe the structure and properties of crystalline and amorphous materials up to 12 GPa at room temperature or 7 GPa at 2000°C. During the recent APS upgrade, 16-BM-B undertook major improvements to its instrumentation and measurement techniques. The upgrade includes the addition of a 1.2 m horizontal “condenser” mirror and a new variable-sized collimation system, the combination of which decreases the acquisition time for energy dispersive X-ray diffraction measurements by a factor of 10 when compared to pre-upgrade measurements. The addition of a new Ge energy-sensitive detector and DANTE (XGLab) digital pulse processor allows for processing the increased diffraction counts with minimal deadtime. In addition to upgraded beamline components, new techniques are being developed for eventual release to the user community, including electrical resistivity and tomography measurements.

APS upgrade↗

A precision star tracker utilizing advanced techniques and materials

An image dissector star tracker has been developed which operates in the photon counting mode making it possible to utilize all digital electronics. A unique pulse processing circuit allows bright stars to be tracked as well as dim stars. Thermal mechanical stability has been greatly enhanced by fabricating a housing with graphite/epoxy composite material with a linear coefficient of thermal expansion near zero. Test results indicate the +10 Mv stars can be acquired and tracked, while position variation with star intensity is less than 2 arc seconds from 2.5 Mv to +10 Mv. The noise equivalent angle for a +8 Mv star is 3 arc seconds. Polynominal correction for remaining cross-coupling and nonlinearity reduced error over total 1 x 1 deg field to 1.5 arc seconds.

Gates, R. F.↗

Portable-Beacon Landing System for Helicopters

Prototype beacon landing system (BLS) allows helicopters to make precise landings in all weather. BLS easily added to existing helicopter avionic equipment and readily deployed at remote sites. Small and light, system employs X-band radar and digital processing. Variety of beams pulsed sequentially by ground station after initial interrogation by weather radar of approaching helicopter. Airborne microprocessor processes pulses to determine glide slope, course deviation, and range.

Davis, Thomas J.↗

High rate pulse processing algorithms for microcalorimeters

It has been demonstrated that microcalorimeter spectrometers based on superconducting transition-edge-sensor can readily achieve sub-100 eV energy resolution near 100 keV. However, the active volume of a single microcalorimeter has to be small to maintain good energy resolution, and pulse decay times are normally in the order of milliseconds due to slow thermal relaxation. Consequently, spectrometers are typically built with an array of microcalorimeters to increase detection efficiency and count rate. Large arrays, however, require as much pulse processing as possible to be performed at the front end of the readout electronics to avoid transferring large amounts of waveform data to a host computer for processing. In this paper, they present digital filtering algorithms for processing microcalorimeter pulses in real time at high count rates. The goal for these algorithms, which are being implemented in the readout electronics that they are also currently developing, is to achieve sufficiently good energy resolution for most applications while being (a) simple enough to be implemented in the readout electronics and (b) capable of processing overlapping pulses and thus achieving much higher output count rates than the rates that existing algorithms are currently achieving. Details of these algorithms are presented, and their performance was compared to that of the 'optimal filter' that is the dominant pulse processing algorithm in the cryogenic-detector community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scaling trends in SET pulse widths in Sub-100 nm bulk CMOS processes.

Digital single-event transient (SET) measurements in a bulk 65-nm process are compared to transients measured in 130-nm and 90-nm processes. The measured SET widths are shorter in a 65-nm test circuit than SETs measured in similar 90-nm and 130-nm circuits, but, when the factors affecting the SET width measurements (in particular pulse broadening and the parasitic bipolar effect) are considered, the actual SET width trends are found to be more complex. The differences in the SET widths between test circuits can be attributed in part to differences in n-well contact area. These results help explain some of the inconsistencies in SET measurements presented by various researchers over the past few years.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tailpulse signal generator

A tailpulse signal generating/simulating apparatus, system, and method designed to produce electronic pulses which simulate tailpulses produced by a gamma radiation detector, including the pileup effect caused by the characteristic exponential decay of the detector pulses, and the random Poisson distribution pulse timing for radioactive materials. A digital signal process (DSP) is programmed and configured to produce digital values corresponding to pseudo-randomly selected pulse amplitudes and pseudo-randomly selected Poisson timing intervals of the tailpulses. Pulse amplitude values are exponentially decayed while outputting the digital value to a digital to analog converter (DAC). And pulse amplitudes of new pulses are added to decaying pulses to simulate the pileup effect for enhanced realism in the simulation.

47 OTHER INSTRUMENTATION↗

Overview of patient dosimetry in diagnostic radiology in the USA for the past 50 years

This review covers the role of medical physics in addressing issues directly related to patient dosimetry in radiography, fluoroscopy, mammography, and CT. The sections on radiography and fluoroscopy radiation doses review the changes that have occurred during the last 50 to 60 years. A number of technological improvements have contributed to both a significant reduction in patient and staff radiation doses and improvements to the image quality during this period of time. There has been a transition from film-screen radiography with hand dip film processing to electronic digital imaging utilizing CR and DR. Similarly, fluoroscopy has progressed by directly viewing image intensifiers in darkened rooms to modern flat panel image receptor systems utilizing pulsed radiation, automated variable filtration, and digitally processed images. Mammography is one of the most highly optimized imaging procedures performed, because it is a repetitive screening procedure that results in annual radiation exposure. Mammography is also the only imaging procedure in the United States in which the radiation dose is regulated by the federal government. Consequently, many medical physicists have studied the dosimetry associated with screen-film and digital mammography. In this review, a brief history of mammography dose assessment by medical physicists is discussed. CT was introduced into clinical practice in the early 1970s, and has grown into one of the most important modalities available for diagnostic imaging. CT dose quantities and measurement techniques are described, and values of radiation dose for different types of scanner are presented. Organ and effective doses to adult patients are surveyed from the earliest single slice scanners, to the latest versions that include up to two x-ray tubes and can incorporate as many as 256 detector channels. An overview is provided of doses received by pediatric patients undergoing CT examinations, as well as methods, and results, of studies performed to assess the radiation absorbed by the conceptus of pregnant patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma ray spectroscopy employing divalent europium-doped alkaline earth halides and digital readout for accurate histogramming

According to one embodiment, a scintillator radiation detector system includes a scintillator, and a processing device for processing pulse traces corresponding to light pulses from the scintillator, where the processing device is configured to: process each pulse trace over at least two temporal windows and to use pulse digitization to improve energy resolution of the system. According to another embodiment, a scintillator radiation detector system includes a processing device configured to: fit digitized scintillation waveforms to an algorithm, perform a direct integration of fit parameters, process multiple integration windows for each digitized scintillation waveform to determine a correction factor, and apply the correction factor to each digitized scintillation waveform.

36 MATERIALS SCIENCE↗

Modular, Parallel Pulse-Shaping Filter Architectures

Novel architectures based on parallel subconvolution frequency-domain filtering methods have been developed for modular processing rate reduction of discrete-time pulse-shaping filters. Such pulse-shaping is desirable and often necessary to obtain bandwidth efficiency in very-high-rate wireless communications systems. In principle, this processing could be implemented in very-large-scale integrated (VLSI) circuits. Whereas other approaches to digital pulse-shaping are based primarily on time-domain processing concepts, the theory and design rules of the architectures presented here are founded on frequency-domain processing that has advantages in certain systems.

Gray, Andrew A.↗

Bandwidth Efficient Wireless Digital Modem Developed

NASA Lewis Research Center has developed a digital approach for broadcasting highfidelity audio (nearly compact disk (CD) quality sound) in the commercial frequencymodulated (FM) broadcast band. This digital approach provides a means of achieving high data transmission rates with low hardware complexity--including low mass, size, and power consumption. Lewis has completed the design and prototype development of a bandwidth-efficient digital modem (modulator and demodulator) that uses a spectrally efficient modulation scheme: 16-ary rectangular quadrature amplitude modulation, or 16- ary QAM. The digital implementation is based strictly on inexpensive, commercial off-theshelf digital signal processing (DSP) hardware to perform up and down conversions and pulse shaping. The digital modem transmits data at rates up to 76 kilobits per second (kbps), which is almost 3 times faster than standard 28.8-kbps telephone modems. In addition, the modem offers improved power and spectral performance, flexible operation, and low-cost implementation.

Kifle, Muli↗