Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Remote sensing using solid-state array technology

The paper describes the design features and capabilities of a remote sensor that uses solid-state linear arrays and operates in a 'pushbroom' scan mode to provide the required performance. Pushbroom scanning is a term describing the technique of using the forward motion of a satellite platform to sweep a linear array of detectors oriented perpendicular to the ground track across a scene being imaged. One array is typically used for each spectral channel. Satellite motion provides one direction of scan and electronic sampling of the detectors in the crosstrack dimension provides the orthogonal scan component to form an image. The detector array is sampled at the appropriate rate so that contiguous lines are produced. The performance of a pushbroom system is discussed relative to radiometric sensitivity, detector array geometric fidelity, and radiometric correction. System advantages are precision geometric positioning of the detectors, very high sensitivity and favorable SNR, low power consumption, and no moving optics.

Thompson, L. L.↗

Design of Low Power CMOS Read-Out with TDI Function for Infrared Linear Photodiode Array Detectors

A new low voltage CMOS infrared readout circuit using the buffer-direct injection method is presented. It uses a single supply voltage of 1.8 volts and a bias current of 1uA. The time-delay integration technique is used to increase the signal to noise ratio. A current memory circuit with faulty diode detection is used to remove dark current for background compensation and to disable a photodiode in a cell if detected as faulty. Simulations are shown that verify the circuit that is currently in fabrication in 0.5ym CMOS technology.

Vizcaino, Paul↗

Adaptive nonlinear optimization of the signal-to-noise ratio of an array subject to a constraint.

Investigation of a stochastic projected gradient algorithm which can be used to find a constrained optimum point for a concave or convex objective function subject to nonlinear constraints. When the constraint consists of only one linear equation, convergence to the constrained optimum value is proven, and bounds are obtained for the rate of convergence of the algorithm to the constrained optimum value. This algorithm is then applied to the nonlinear problem of automatically making an array of detectors form a beam in a desired direction in space when unknown interfering noise is present so as to maximize the signal-to-noise ratio subject to a constraint on the supergain ratio.

Winkler, L. P.↗

Low-background direct readout array performance

The development and evaluation of an integrated array of antimony-doped silicon detectors is described. The spectral range of extrinsic silicon-integrated arrays useful for low-background IR astronomical applications is extended to about 31 microns with this development. The 58 x 62-element array is accessed by a direct readout multiplexer. The device is evaluated with a flexible microcomputer-based drive and readout electronics system in a low-background test dewar. Acceptance testing indicates single-pixel NEPs in the mid-10 to the -18th W/sq rt Hz range, and good global uniformity statistics.

Goebel, J. H.↗

Coherent Detection of High-Rate Optical PPM Signals

A method of coherent detection of high-rate pulse-position modulation (PPM) on a received laser beam has been conceived as a means of reducing the deleterious effects of noise and atmospheric turbulence in free-space optical communication using focal-plane detector array technologies. In comparison with a receiver based on direct detection of the intensity modulation of a PPM signal, a receiver based on the present method of coherent detection performs well at much higher background levels. In principle, the coherent-detection receiver can exhibit quantum-limited performance despite atmospheric turbulence. The key components of such a receiver include standard receiver optics, a laser that serves as a local oscillator, a focal-plane array of photodetectors, and a signal-processing and data-acquisition assembly needed to sample the focal-plane fields and reconstruct the pulsed signal prior to detection. The received PPM-modulated laser beam and the local-oscillator beam are focused onto the photodetector array, where they are mixed in the detection process. The two lasers are of the same or nearly the same frequency. If the two lasers are of different frequencies, then the coherent detection process is characterized as heterodyne and, using traditional heterodyne-detection terminology, the difference between the two laser frequencies is denoted the intermediate frequency (IF). If the two laser beams are of the same frequency and remain aligned in phase, then the coherent detection process is characterized as homodyne (essentially, heterodyne detection at zero IF). As a result of the inherent squaring operation of each photodetector, the output current includes an IF component that contains the signal modulation. The amplitude of the IF component is proportional to the product of the local-oscillator signal amplitude and the PPM signal amplitude. Hence, by using a sufficiently strong local-oscillator signal, one can make the PPM-modulated IF signal strong enough to overcome thermal noise in the receiver circuits: this is what makes it possible to achieve near-quantum-limited detection in the presence of strong background. Following quantum-limited coherent detection, the outputs of the individual photodetectors are automatically aligned in phase by use of one or more adaptive array compensation algorithms [e.g., the least-mean-square (LMS) algorithm]. Then the outputs are combined and the resulting signal is processed to extract the high-rate information, as though the PPM signal were received by a single photodetector. In a continuing series of experiments to test this method (see Fig. 1), the local oscillator has a wavelength of 1,064 nm, and another laser is used as a signal transmitter at a slightly different wavelength to establish an IF of about 6 MHz. There are 16 photodetectors in a 4 4 focal-plane array; the detector outputs are digitized at a sampling rate of 25 MHz, and the signals in digital form are combined by use of the LMS algorithm. Convergence of the adaptive combining algorithm in the presence of simulated atmospheric turbulence for optical PPM signals has already been demonstrated in the laboratory; the combined output is shown in Fig. 2(a), and Fig. 2(b) shows the behavior of the phase of the combining weights as a function of time (or samples). We observe that the phase of the weights has a sawtooth shape due to the continuously changing phase in the down-converted output, which is not exactly at zero frequency. Detailed performance analysis of this coherent free-space optical communication system in the presence of simulated atmospheric turbulence is currently under way.

Vilnrotter, Victor↗

A stochastic constrained optimization technique and its application to detector array processing.

A stochastic projected gradient algorithm is proposed which can be used for finding a constrained optimum point for a concave or convex objective function subject to nonlinear constraints which form a connected region even when only a noisy estimate of the objective function is available. For a constraint described by a single linear equation, convergence to the constrained optimum value is proved, and the rate of convergence of the algorithm to the constrained optimum value is determined. The algorithm is applied to the nonlinear problem of obtaining automatically an array of detectors which forms a beam in a desired direction in space in the presence of interfering noise so as to maximize the SNR subject to a constraint on the super-gain ratio.

Winkler, L. P.↗

Intensified charge coupled devices for use as a spaceborne spectrographic image-plane detector system

An instrument that has been developed for studies of atmospheric emissions from the Space Shuttle comprises an array of imaging spectrometers to observe features over the 300-12,000-A wavelength range. Each spectrometer has a 2-D image-plane detector system on which spectral information is dispersed in one direction and spatial information is resolved in the other. The detectors consist of CCD arrays which are coupled to proximity focused image intensifiers. The intensifier in each case is selected for the wavelength range covered by the particular spectrometer. The result is a compact low-power spectrographic detector system. In the course of building the five flight detector systems, there was occasion to evaluate a larger number of the charge coupled devices and the proximity focused image intensifiers. Various characteristics, advantages, and shortcomings of these devices and the overall intensified CCD system are reported.

Torr, M. R.↗

Gain calibrating nonuniform image-array data using only the image data

An algorithm is developed for calibrating the spatial nonuniformity of image-array (CCD-type) detectors. Like other techniques this approach uses multiple, spatially displaced images. In circumstances where high-precision flat fields are not available by other means (i.e., sky flats) this technique is advantageous as it uses the data frames for gain calibration even when the array images extended, nonuniform, sources. Numerical experiments and direct observations with intrinsically uniform and quite nonuniform detectors show that this algorithm is useful when data frames are crowded with sources - circumstance where 'median filtering' flatfielding techniques often fail. The algorithm described is robust and efficiently uses information from multiple data frames to determine pixel gain variations, using visible and IR array observations of extended sources.

Kuhn, J. R.↗

CHARGING OF DEVICES BY MICROWAVE POWER BEAMING

A system for providing wireless, charging power and/or primary power to electronic/electrical devices is described whereby microwave energy is employed. Microwave energy is focused by a power transmitter comprising one or more adaptively-phased microwave array emitters onto a device to be charged. Rectennas within the device to be charged receive and rectify the microwave energy and use it for battery charging and/or for primary power. A locator signal generated by the device to be charged is analyzed by the system to determine the location of the device to be charged relative to the microwave array emitters, permitting thc microwave energy to be directly specifically towards the device to be charged. Backscatter detectors respond to backscatter energy reflected off of any obstacle between the device to be charged and the microwave array emitters. Power to any obstructed microwave array emitter is reduced until the obstruction is removed. Optionally, data can be modulated onto microwave energy beams produced by the array emitter and demodulated by the device, thereby providing means of data communication from the power transmitter to the device. Similarly, data can be modulated onto the locator signal and demodulated in the power transmitter, thereby providing means of data communication from the device to the power transmitter.

Landis, Geoffrey A.↗

Two complimentary methods for aligning linear arrays

Two approaches are presented for implementing a simple method for aligning the object and image planes of linear arrays of elemental detectors. Both variants begin by firing a laser beam into cubic beamsplitters which change the direction of the resulting parallel beams to one perpendicular to the array. A neutral density filter is located along the beam path and an optical microscope is located beyond the exit plane of the beamsplitters. In the first variant, the beam is tuned to the spectral sensitivity of the elements. In the second version, a lens and a microscope are situated outside the exit plane of the beamsplitters, and spectral tuning is unnecessary. Subsequent rotations of the array are shown to reveal the coincidence or lack of coincidence of the image plane and the linear array.

Finkel, Mitchell W.↗

Detector Arrays for an Airborne Infrared Echelle Spectrometer

The design of a long-slit echelle spectrograph covering the 16 - 210 micron range for use on the Stratospheric Observatory for Infrared Astronomy (SOFIA) is under study at NASA-Ames. This wavelength range is selected for its content of important astrophysical spectral lines accessible from an airborne platform, and availability of suitable detectors. Two dimensional arrays will be used to simultaneously provide spectral coverage in the dispersion direction and imaging in the cross-dispersion direction. Major goals are: (1) to reach sensitivities limited primarily by the background from the residual atmosphere and the telescope; (2) to provide imaging not far from the diffraction limit of the 2.5 meter (effective) aperture of the telescope; and (3) to obtain diffraction-limited spectral resolution from the large echelle grating, which means that the resolving power increases with decreasing wavelength. To meet these requirements, three detector types are forseen: a commercially available monolithic Si:Sb IBC array to cover the wavelength range from 16 to 40 microns, a Ge:Sb photoconductor array to cover the range from 40 to 125 microns, and a stressed Ge:Ga photoconductor array covering the range from 125 to 210 microns. The paper discusses details of the studies and plans for the field optics, detectors, and readouts.

Erickson, E. F.↗

Spectrum-Imaging Detector Array With Integrated Filter

Proposed rectangular array of photodetectors in imaging spectrometer includes integral filter deposited directly on imaging array which would not become misaligned or misregistered as result of mechanical shock, vibration, or differential thermal expansion. Need for precise alignment and registration of filter cannot be over-emphasized.

Labaw, Clayton C.↗

Dielectric Covered Planar Antennas at Submillimeter Wavelengths for Terahertz Imaging

Most optical systems require antennas with directive patterns. This means that the physical area of the antenna will be large in terms of the wavelength. When non-cooled systems are used, the losses of microstrip or coplanar waveguide lines impede the use of standard patch or slot antennas for a large number of elements in a phased array format. Traditionally, this problem has been solved by using silicon lenses. However, if an array of such highly directive antennas is to be used for imaging applications, the fabrication of many closely spaced lenses becomes a problem. Moreover, planar antennas are usually fed by microstrip or coplanar waveguides while the mixer or the detector elements (usually Schottky diodes) are coupled in a waveguide environment. The coupling between the antenna and the detector/ mixer can be a fabrication challenge in an imaging array at submillimeter wavelengths. Antennas excited by a waveguide (TE10) mode makes use of dielectric superlayers to increase the directivity. These antennas create a kind of Fabry- Perot cavity between the ground plane and the first layer of dielectric. In reality, the antenna operates as a leaky wave mode where a leaky wave pole propagates along the cavity while it radiates. Thanks to this pole, the directivity of a small antenna is considerably enhanced. The antenna consists of a waveguide feed, which can be coupled to a mixer or detector such as a Schottky diode via a standard probe design. The waveguide is loaded with a double-slot iris to perform an impedance match and to suppress undesired modes that can propagate on the cavity. On top of the slot there is an air cavity and on top, a small portion of a hemispherical lens. The fractional bandwidth of such antennas is around 10 percent, which is good enough for heterodyne imaging applications.The new geometry makes use of a silicon lens instead of dielectric quarter wavelength substrates. This design presents several advantages when used in the submillimeter-wave and terahertz bands: a) Antenna fabrication compatible with lithographic techniques. b) Much simpler fabrication of the lens. c) A simple quarter-wavelength matching layer of the lens will be more efficient if a smaller portion of the lens is used. d) The directivity is given by the lens diameter instead of the leaky pole (the bandwidth will not depend anymore on the directivity but just on the initial cavity). The feed is a standard waveguide, which is compatible with proven Schottky diode mixer/detector technologies. The development of such technology will benefit applications where submillimeter- wave heterodyne array designs are required. The main fields are national security, planetary exploration, and biomedicine. For national security, wideband submillimeter radars could be an effective tool for the standoff detection of hidden weapons or bombs concealed by clothing or packaging. In the field of planetary exploration, wideband submillimeter radars can be used as a spectrometer to detect trace concentrations of chemicals in atmospheres that are too cold to rely on thermal imaging techniques. In biomedicine, an imaging heterodyne system could be helpful in detecting skin diseases.

Chattopadhyay, Goutam↗

Angular Resolution of an EAS Array for Gamma Ray Astronomy at Energies Greater Than 5 x 10 (13) Ev

A 24 detector extensive air shower array is being operated at Ootacamund (2300 m altitude, 11.4 deg N latitude) in southern India for a study of arrival directions of showers of energies greater than 5 x 10 to the 13th power eV. Various configurations of the array of detectors have been used to estimate the accuracy in determination of arrival angle of showers with such an array. These studies show that it is possible to achieve an angular resolution of better than 2 deg with the Ooty array for search for point sources of Cosmic gamma rays at energies above 5 x 10 to the 13th power eV.

Apte, A. R.↗

Earth Radiation Array (ERA)

The NASA's Earth Radiation Array (ERA), which is currently being developed to provide calibrated radiation measurements from various areas of the earth for at least 11 years, i.e., one solar cycle, contains a mosaic array of detectors which measures the outgoing radiation of the earth in all directions without the need for mechanical scanning. The angular measurements obtained by the ERA over set intervals of time will be integrated to produce total reflected and emitted flux values from each of the target areas. The ERA is designed as a relatively small instrument (less than 1-cu-m volume and 100-kg mass), which can be included in the payload complement of many different satellites. The key requirement of the ERA is the ability to operate for up to 11 years continuously and without failure.

Hoffman, James W.↗

Nonscanning climate sensor study

The Nonscanning Climate Sensor represents a new instrument for climate research and global monitoring of the earth radiation budget. It contains a mosaic of array of detectors which measures the outgoing radiation of the earth in all directions without the need for mechanical scanning. The goal is to eliminate all moving parts and obtain highly calibrated measurements for up to one solar cycle (11 years) without being susceptible to mechanical failure. Over set intervals of time, the angular measurements are integrated up to produce total reflected and emitted flux values from each target area on the Earth. To achieve the require sensitivity while maintaining a flat spectral response, an improved dual cavity detector with digital control loop was developed. The detector is self calibrating to maintain high precision over the life of the instrument. Prototype detectors and a complete set of electronics with a microprocessor controller were fabricated and tested. Measurements show that the new detectors are more than an order of magnitude more sensitive than previous versions.

Hoffman, James W.↗

Initial On-Orbit Spatial Resolution Characterization of OrbView-3 Panchromatic Images

Characterization was conducted under the Memorandum of Understanding among Orbital Sciences Corp., ORBIMAGE, Inc., and NASA Applied Sciences Directorate. Acquired five OrbView-3 panchromatic images of the permanent Stennis Space Center edge targets painted on a concrete surface. Each image is available at two processing levels: Georaw and Basic. Georaw is an intermediate image in which individual pixels are aligned by a nominal shift in the along-scan direction to adjust for the staggered layout of the panchromatic detectors along the focal plane array. Georaw images are engineering data and are not delivered to customers. The Basic product includes a cubic interpolation to align the pixels better along the focal plane and to correct for sensor artifacts, such as smile and attitude smoothing. This product retains satellite geometry - no rectification is performed. Processing of the characterized images did not include image sharpening, which is applied by default to OrbView-3 image products delivered by ORBIMAGE to customers. Edge responses were extracted from images of tilted edges in two directions: along-scan and cross-scan. Each edge response was approximated with a superposition of three sigmoidal functions through a nonlinear least-squares curve-fitting. Line Spread Functions (LSF) were derived by differentiation of the analytical approximation. Modulation Transfer Functions (MTF) were obtained after applying the discrete Fourier transform to the LSF.

Blonski, Slawomir↗