Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct electron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Search for New Physics with the Compact Muon Solenoid Experiment and QIS-enabled Technology

Understanding the fundamental nature of dark matter (DM)---its cosmological origin, constituents, and interactions---is one of the most important questions in fundamental science today. In this thesis, I present two novel and highly complementary approaches to cover the gaps in sensitivity of current DM searches. The searches are enabled by a first-of-its-kind reconstruction technique to search for hidden-sector particles using the Compact Muon Solenoid (CMS) and by new advances in quantum sensing technology to search for axions and hidden-sector DM. In the first part of this thesis, I present a search for long-lived hidden sector particles, predicted by many extensions of the SM, using a novel technique to reconstruct decays of long-lived particles (LLPs) in the CMS muon detector. The innovative LLP reconstruction technique is sensitive to a broad range of LLP decays and to LLP masses below GeV. The search yields competitive sensitivity for proper lifetime 0.1--1000 m with the full Run 2 dataset recorded at the LHC between 2016--2018 at $\sqrt{s} = 13~$TeV. To extend the physics reach of this novel muon detector shower (MDS) signature, I present the model-independence of MDS and the reinterpretation of the search to a large number of LLP models, demonstrating its complementarity with proposed and existing dedicated LLP experiments. Finally, I present a new dedicated MDS trigger that improves the trigger efficiency by at least an order of magnitude and was deployed in 2022, at the start of Run 3 of the LHC operations. In the second part of the thesis, I present for the first time, the use of a novel quantum sensor, the low-noise and single-photon sensitive superconducting nanowire single photon detectors (SNSPDs), to directly detect dark matter. The low detection threshold and ultra-low dark count rate of SNSPDs can close the gap in DM discovery reach due to the current limitations in detector sensitivity. I will present my work on the development and characterization of SNSPDs for two entirely new experiments to directly detect axions via absorption and hidden-sector DM via electron scattering. The search for axions employs a novel broadband reflector technique with the Broadband Reflector Experiment for Axion Detection (BREAD). A unique parabolic mirror is then used to focus axion-converted photons to the SNSPDs, extending the reach to axion masses of 0.04--1 eV. On the other hand, by coupling the SNSPDs with gallium arsenide, a bright cryogenic scintillator well matched to SNSPD detection, a prototype sensing system can be built as a basis of new direct DM detection experiments capable of extending the discovery to DM masses as low as 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffractive Imaging of Conical Intersections Amplified by Resonant Infrared Fields

The fate of virtually all photochemical reactions is determined by conical intersections. These are energetically degenerate regions of molecular potential energy surfaces that strongly couple electronic states, thereby enabling fast relaxation channels. Their direct spectroscopic detection relies on weak features that are often buried beneath stronger, less interesting contributions. For azobenzene photoisomerization, a textbook photochemical reaction, we demonstrate how a resonant infrared field can be employed during the conical intersection passage to significantly enhance its coherence signatures in time-resolved Xray diffraction while leaving the product yield intact. Furthermore, this transition-state amplification holds promise to bring signals of conical intersections above the detection threshold.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-electron interference in two-photon attosecond double ionization of neon

The pump-probe experiments enabled by x-ray free-electron lasers (XFEL) will allow us to directly observe correlated electronic motion with attosecond time resolution by detecting photoelectron pairs in coincidence. In helium, the transition between the nonsequential and sequential regime in two-photon double ionization (TPDI) is well explained by a virtual-sequential model. Much less is known, however, about the TPDI process in more complex atoms. Recently, we extended the virtual-sequential model to arbitrary light pulses [Chattopadhyay Phys. Rev. A 108, 013114 (2023)]. This extension employs multichannel scattering states for the single ionization of both the neutral and the ionized target, which we initially applied to helium. In the present study, we show that our extended virtual-sequential model reproduces the qualitative features of the angularly integrated observables with available experimental results for neon, a considerably more complex target. We observe an intriguing feature of inverted two-particle interference in the joint-energy distribution of Ne compared to He. Finally, this phenomenon, attributable to the presence of a final doubly ionized state with triplet symmetry coupled to the two photoelectrons, should be observable with current experimental technologies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Emerging anomaly detection techniques for electronic health records: A survey

Background Anomaly detection in electronic health records (EHRs) is a cornerstone of biomedical informatics, with direct implications for patient safety, clinical decision-making, and the prevention of healthcare fraud. Once guided primarily by simple rule-based methods, the field has advanced rapidly, driven by increased computing power, richer and more detailed health data, and the rise of machine learning and deep learning techniques. The objective of this paper is to provide a comprehensive overview of modern approaches to detecting anomalies in EHRs, outlining their strengths, limitations, and relevance to key healthcare challenges. We review traditional statistical methods alongside newer ML- and DL-based strategies and hybrid models, with particular attention to how these techniques support transparency and build clinical trust. Methods This paper presents a thorough and critical survey through systematic review (PRISMA-based) of the latest anomaly detection strategies in time-sequence data domains within electronic health record systems. Results We explore a broad spectrum of methodologies, including statistical models, supervised and unsupervised learning approaches, hybrid frameworks, and state-of-the-art ML-based techniques that collectively advance the precision and scalability of detecting anomalies in complex clinical datasets. In addition to mapping current capabilities, we address the enduring challenges that hinder widespread implementation and provide a forward-looking perspective on the future of anomaly detection in the data-rich landscape of modern healthcare. Summary The advancement in AI-based approaches is reported along with the basic principles of the individual approaches and their applicability. The increased availability of high-quality data, advancements in DL approaches, and enhanced computation power are leading to more frequent adaptation of DL-based approaches. Emerging DL-based approaches that have been adapted in other domains or recently applied in the EHR domain are also discussed in detail. Although DL-based approaches can improve model predictions by incorporating comorbidities, their application is limited in low-frequency data domains (e.g., when the total available data remains in the single digits). Therefore, the user must carefully consider the application based on data availability.

Anomaly detection↗

Light new physics in XENON1T

We examine the recently-reported low-energy electron recoil spectrum observed at the XENON1T underground dark matter direct detection experiment, in the context of new interactions with solar neutrinos. In particular we show that scalar and vector mediators with masses $\lesssim 50$ keV coupled to leptons could already leave a visible signature in the XENON1T experiment, similar to the observed peak below 7 keV. This signals that dark matter detectors are already competing with neutrino scattering experiments such as GEMMA, CHARM-II and Borexino. If these results from XENON1T are interpreted as a new signal of such physics, the parameters which fit the excess face challenges from astrophysics which seem very difficult to overcome. If they are rather viewed as a constraint on new couplings, they herald the start of an era of novel precise probes of physics beyond the standard model with dark matter detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-channel direct detection of light dark matter: theoretical framework

We present a unified theoretical framework for computing spin-independent direct detection rates via various channels relevant for sub-GeV dark matter — nuclear re- coils, electron transitions and single phonon excitations. Despite the very different physics involved, in each case the rate factorizes into the particle-level matrix element squared, and an integral over a target material- and channel-specific dynamic structure factor. We show how the dynamic structure factor can be derived in all three cases following the same procedure, and extend previous results in the literature in several aspects. For electron transitions, we incorporate directional dependence and point out anisotropic target materials with strong daily modulation in the scattering rate. For single phonon excitations, we present a new derivation of the rate formula from first principles for generic spin-independent couplings, and include the first calculation of phonon excitation through electron couplings. We also discuss the interplay between single phonon excitations and nuclear recoils, and clarify the role of Umklapp processes, which can dominate the single phonon production rate for dark matter heavier than an MeV. Our results highlight the complementarity between various search channels in probing different kinematic regimes of dark matter scattering, and provide a common reference to connect dark matter theories with ongoing and future direct detection experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large-scale efficient mid-wave infrared optoelectronics based on black phosphorus ink

The mid-wave infrared (MWIR), ranging from 2 to 5 micrometers, is of substantial interest for chemical sensing, imaging, and spectroscopy. Black phosphorus (bP)–based MWIR light emitters and detectors have been shown to outperform the state-of-the-art for commercial devices due to the low Auger recombination coefficient of bP. However, the scalability of these devices remains a challenge. Here, we report a bP ink formula that preserves the exceptional MWIR optoelectronic properties of bP to deposit centimeter-scale, uniform, and pinhole free films with a photoluminescence quantum yield higher than competing III-V and II-VI semiconductors with similar bandgaps at high excitation regime. As a proof of concept, we use bP ink as a “phosphor” on a red commercial light-emitting diode to demonstrate bright MWIR light emission. We also show that these films can be integrated into heterostructure device architectures with electron and hole selective contacts for direct-injected light emission and detection in MWIR.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Alignment of the straw tracking detectors for the Fermilab Muon $g − 2$ experiment and systematic studies for a muon electric dipole moment measurement

The Fermilab Muon $g-2$ experiment is currently preparing for its fourth data-taking period (Run-4). The experiment-wide effort on the analysis of Run-1 data is nearing completion, with the announcement of the first result expected in the coming months. The final goal of the experiment is to determine the muon magnetic anomaly to a precision of 140 ppb. This level of precision will provide indirect evidence of new physics, if the central value agrees with the previously-measured value of the magnetic anomaly. Essential in reducing the systematic uncertainty, through measurements of the muon beam profile, are the in-vacuum straw tracking detectors. A crucial prerequisite in obtaining accurate distributions of the beam profile is the internal alignment of the tracking detectors, which is described in this thesis. As a result of this position calibration, the tracking efficiency has increased by 3%, while the track quality increased by 4%. This thesis also discusses an additional measurement that will be made using the tracking detectors: a search for an electric dipole moment (EDM) of the muon, through the direct detection of an oscillation in the average vertical angle of the electron from the muon decay. An observation of a muon EDM would be evidencemore » of new physics and would provide a new source of CP violation in the charged lepton sector. Essential in measuring the EDM are accurate and precise estimations of potential non-zero radial and longitudinal magnetic fields, which were estimated using the Run-1 data. In addition, a preliminary analysis using the Run-1 data was undertaken to estimate the available precision for the magnetic anomaly measurement using the tracking detectors.« less

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation yield from electronic and nuclear recoils in superfluid He 4

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185~keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090~keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. As a result, we also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Matter Candidates of a Very Low Mass

We review dark matter (DM) candidates of a very low mass appearing in the window below the traditional weakly interacting massive particle (m χ ≲ 10 GeV) and extending down to m χ ≳ 1 meV, somewhat below the mass limit at which DM becomes wavelike. Such candidates are motivated by hidden sectors such as hidden valleys, which feature hidden forces and rich dynamics, but have evaded traditional accelerator searches for New Physics because of their relatively weak coupling to the Standard Model (SM). Such sectors can still be detected through dedicated low-energy colliders, which, through their intense beams, can have sensitivity to smaller couplings, or through astrophysical observations of the evolution of DM halos and stellar structures, which, through the Universe's epochs, can be sensitive to small DM interactions. We also consider mechanisms whereby the DM abundance is fixed through the interaction with the SM, which directly motivates the search for light DM in terrestrial experiments. The bulk of this review is dedicated to the new ideas that have been proposed for direct detection of such DM candidates of a low mass through nuclear recoils, electronic excitations, or collective modes such as phonons and magnons. The rich tapestry of materials and modes in the condensed matter landscape is reviewed along with specific prospects for detection.

Physics↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

Cosmology and signals of light pseudo-Dirac dark matter

In this paper, we analyze the cosmological evolution, allowed parameter space, and observational prospects for a dark sector consisting of thermally produced pseudo-Dirac fermions with a small mass splitting, coupled to the Standard Model through a dark photon. This scenario is particularly notable in the context of sub-GeV dark matter, where the mass-off-diagonal leading interaction limits applicability of both CMB energy injection constraints and standard direct detection searches. We present the first general study of the thermal history of pseudo-Dirac DM with splittings from 100 eV to MeV, focusing on the depletion of the heavier “excited” state abundance via scatterings and decays, and on the distinctive signals arising from its small surviving abundance. We analyze CMB energy injection bounds on both DM annihilation and decay, accelerator-based probes, and new line-like direct-detection signals from the excited DM down-scattering on either nuclei or electrons, as well as future search prospects in each channel. We also comment on the relevance of this signal to the few-keV Xenon1T electron excess and on possible diurnal modulation of this signal, and introduce a signal-strength parametrization to facilitate the comparison of future experimental results to theoretical expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Skipper-CCD sensors for the Oscura experiment: requirements and preliminary tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2–10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru.[1 dru (differential rate unit) corresponds to 1 event/kg/day/keV.] In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixed domain coherent link with electrically reconfigurable IMDD and coherent modes for O-band data center applications

We report the first O-band link with electrically reconfigurable intensity-modulation direct-detection (IMDD) and coherent operation using custom silicon photonic chips packaged with commercial electronic chips. Transmission below the KP4-FEC threshold is shown using commercial 53 Gbaud PAM4 digital signal processing (DSP) for 16QAM (200 Gbps/ λ ) and PAM4 (100 Gbps/ λ ). Efficient operation of the packaged full link at 12 and 11.2 pJ/bit is achieved for the PAM4 and 16QAM modes, respectively.

Misak, Stephen (ORCID:0000000154973084)↗

Enhanced cutoff energies for direct and rescattered strong-field photoelectron emission of plasmonic nanoparticles

Abstract The efficient generation, accurate detection, and detailed physical tracking of energetic electrons are of applied interest for high harmonics generation, electron-impact spectroscopy, and femtosecond time-resolved scanning tunneling microscopy. We here investigate the generation of photoelectrons (PEs) by exposing plasmonic nanostructures to intense laser pulses in the infrared (IR) spectral regime and analyze the sensitivity of PE spectra to competing elementary interactions for direct and rescattered photoemission pathways. Specifically, we measured and numerically simulated emitted PE momentum distributions from prototypical spherical gold nanoparticles (NPs) with diameters between 5 and 70 nm generated by short laser pulses with peak intensities of 8.0 × 10 12 and 1.2 × 10 13 W/cm 2 , demonstrating the shaping of PE spectra by the Coulomb repulsion between PEs, accumulating residual charges on the NP, and induced plasmonic electric fields. Compared to well-understood rescattering PE cutoff energies for strong-field photoemission from gaseous atomic targets (10× the ponderomotive energy), our measured and simulated PE spectra reveal a dramatic cutoff-energy increase of two orders of magnitude with a significantly higher contribution from direct photoemission. Our findings indicate that direct PEs reach up to 93 % of the rescattered electron cutoff energy, in contrast to 20 % for gaseous atoms, suggesting a novel scheme for the development of compact tunable tabletop electron sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Redox-Based Electrochemical Affinity Sensor for Detection of Aqueous Pertechnetate Anion

Rapid, selective, in-situ detection of TcO4- in multicomponent matrices consisting of interfering anions such as the ubiquitous NO3- and Cl- or the isostructural and isoelectronic CrO42- is challenging. Present sensors mostly lack the selectivity to exclude these interferences, or the sensitivity to meet the detection limits that are lower than the drinking water standards across the globe. This work presents an affinity based electrochemical sensor for TcO4- detection that relies on selective reductive precipitation of aqueous TcO4- induced by a capture probe immobilized on an electrode platform. This results in a direct decrease of the electron transfer current, the magnitude of the decrease being proportional to the amount of TcO4- added. Using this approach, we were able to achieve a detection limit of 1x10-10 M, which is lower than the drinking water standard of 5.2x10-10 M set by United States Environmental Protection Agency. Our proposed approach also allowed us to detect TcO4- from a multicomponent groundwater sample obtained from a well at the Hanford site in Washington (well 299-W19-36) that also contained NO3- , Cl- and CrO42-, without discernably affecting the detection limits.

Chatterjee, Sayandev↗

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗