Swift BAT Loop Heat Pipe #0 Temperature Droop Problem and Solution After Its Primary Heater Controller Failure

The primary heater controller for Burst Alert Telescope (BAT) loop heat pipe (LHP) #0 failed on March 31, 2010. It has been disabled. The secondary heater circuit is operational. However the set point tolerance of the secondary heater controller is significantly out of specifications. A novel variable conductance heat pipe (VCHP) is used to pre-condition the LHP propylene liquid before it returns to the compensation chamber (CC). Due to the limit on the quantity of power switches, the LHP and VCHP temperatures are controlled by different channels of the same heater controller. For this reason, the VCHP heater controller channel is also out of specification. It caused larger tolerances in the temperature of the propylene liquid returning to the CC. As a result, there were intermittent temperature droops every 10-14 days at the coldest attitude during the eclipse. After the set point of the secondary heater controller was gradually increased from 8 C to 8.7 C, there was no temperature droop for over four months.

Choi, Michael K.↗

Bounded Universal Droop Control to Enable the Operation of Power Inverters Under Some Abnormal Conditions and Maintain Voltage and Frequency Within Predetermined Ranges

The universal droop control (UDC) can be applied to power inverters having an impedance angle between -pi/2 rad and pi/2 rad to achieve voltage and frequency regulation and accurate proportional power sharing without the need of knowing the type or value of impedance. However, there is an increasing need for voltage and frequency regulation within predetermined ranges even under some abnormal conditions, such as overloading, sensor faults, and large set-point changes, etc. In this paper, a bounded nonlinear dynamics is introduced into the UDC to ensure that the voltage and frequency can always stay within predetermined ranges under normal and some abnormal conditions, up to hardware limits when current protection needs to be triggered. As a result, the proposed controller can extend the operational range of power inverters in terms of voltage and frequency regulation to cover different scenarios. More importantly, the ranges for both voltage and frequency can be chosen independently from each other. Since the original structure of the UDC is kept in the proposed controller, the properties of the UDC, such as without the need of knowing the type or value of impedance, are well maintained. Furthermore, the closed-loop stability of the system is established via the Lyapunov method. Extensive simulation and experimental results are presented to validate the effectiveness of the proposed controller.

14 SOLAR ENERGY↗

Empirical Evaluation of GPS Clock Accuracy for Isochronous Droop-based Inverters

Grid-forming inverters rely upon an internal reference to regulate the grid 's voltage and frequency. Without a reliable reference, issues such as loss of synchronism, frequency instability, and unequal power sharing can occur. One proposed internal phase reference for grid-forming inverters is generated by the controller's clock, but this is affected by nonidealities in the crystal oscillator leading to time drift in the phase reference. To improve the controller's clock accuracy, the Global Positioning System (GPS) can be used to calibrate the internal clock. Previously, GPS-based clock calibration was explored theoretically and various methods were developed for mitigating frequency/phase drift at the power system level. This paper experimentally validates the direct performance of GPS time-calibration at the controller level and justifies its use in maintaining an accurate phase reference for droop-based grid-forming inverters.

clock drift↗

Charge-Based Droop Control Addressing Control Saturation for Low-Inertia Converters

With bulky dc-link capacitors/inductors, traditional voltage-source converters (VSCs) and current-source converters (CSCs) feature a large inertia to facilitate the converter control under large transients. To achieve high power density with reduced cost, low-inertia converters (LICs) featuring significantly reduced dc-link capacitors/inductors have attracted growing attention. However, without bulky dc-link energy buffer, LICs are prone to control saturation under large transients, resulting in undesired oscillation and instability. This issue cannot be managed by traditional proportional-integral based control due to the low inertia. And it will deteriorate when several LICs are connected in series. To address this challenge in LICs, a model-predictive control (MPC) with a computation-inexpensive feed-forward compensation method has been proposed to provide fast dynamic responses. But it would suffer control saturation under larger transients that degrades the control performance. In this article, a charge-based droop control (CDC) is proposed to address this remaining challenge. This paper firstly analyzes the control saturation challenge in LICs by using a tri-port soft-switching solid-state transformer as an example. Next, the operating principle of the proposed CDC are introduced. Two different implementation approaches are discussed in detail. Lastly, the proposed scheme is validated in simulation with a high-fidelity model of hardware prototype. As a result, the proposed CDC eliminated the 2 kHz oscillation and reduced the dc-link ripple and overshoot due to control saturation by 75% and 50%, respectively.

30 DIRECT ENERGY CONVERSION↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Development of an Adaptive Droop Control Method for Interconnected Lunar DC Microgrids Using Power Hardware-in-the-Loop

NASA’s Artemis Program outlines the need for a habitat capable of sustaining human life as well as mining and producing raw materials on the lunar surface. This mission is viewed as a means towards deeper space exploration, with plans for reaching Mars and beyond. Human presence on the moon is not possible without the ability to generate and distribute energy, namely electricity, through a network of energy sources, loads, and power converters called a microgrid. Multiple microgrids can be deployed on the moon based on location and need. Separate microgrids will require interconnection to increase resiliency and reliability given the mission’s high criticality. A method for adaptive control over power converters connecting two dc microgrids is proposed. A simulation is modeled after the lunar power system with two approaches to power converter droop control, allowing for a more flexible and adaptive microgrid architecture. Further experiments are conducted using the control methods in a power hardware-in-the-loop test environment to study the performance of hardware converter control used in this application.

dc microgrid↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Empirical Evaluation of GPS Clock Accuracy for Isochronous Droop-Based Inverters: Preprint

Grid-forming inverters rely upon an internal reference to regulate the grid’s voltage and frequency. Without a reliable reference, issues such as loss of synchronism, frequency instability, and unequal power sharing can occur. One proposed internal phase reference for grid-forming inverters is generated by the controller’s clock, but this is affected by nonidealities in the crystal oscillator leading to time drift in the phase reference. To improve the controller’s clock accuracy, the Global Positioning System (GPS) can be used to calibrate the internal clock. Previously, GPS-based clock calibration was explored theoretically and various methods were developed for mitigating frequency/phase drift at the power system level. This paper experimentally validates the direct performance of GPS time-calibration at the controller level and justifies its use in maintaining an accurate phase reference for droop-based grid-forming inverters.

clock drift↗

Influence of trap-assisted and intrinsic Auger–Meitner recombination on efficiency droop in green InGaN/GaN LEDs

Here, we study the impact of deep-level defects on trap-assisted Auger–Meitner recombination in c-plane InGaN/GaN LEDs using a small-signal electroluminescence (SSEL) method and deep-level optical spectroscopy (DLOS). Carrier dynamics information, including carrier lifetime, recombination rate, and carrier density, is obtained from SSEL, while DLOS is used to obtain the deep-level defect density. Through fitting the nonradiative recombination rates of wafers with different deep-level defect densities, we obtain the Shockley–Read–Hall (SRH) and trap-assisted Auger–Meitner recombination (TAAR) coefficients. We show that defect-related nonradiative recombination, including both SRH and TAAR, accounts for a relatively small fraction of the total nonradiative recombination, which is dominated by intrinsic Auger–Meitner recombination. The interplay between carrier localization and Coulomb enhancement has a different impact on radiative and intrinsic Auger–Meitner recombination. Evidence is presented that the imbalance between the change of radiative and intrinsic Auger–Meitner recombination is the primary cause of the efficiency droop at high carrier densities in the samples studied.

36 MATERIALS SCIENCE↗

A Current Limiting Control Strategy for Single-Loop Droop-Controlled Grid-Forming Inverters Under Balanced and Unbalanced Faults

Existing studies reporting current limiting control strategies for grid-forming inverters primarily focus on grid-forming inverters that use a multi-loop control structure. This study reports a current limiting control for grid-forming inverters that uses a single-loop control structure. The proposed current limiting control was implemented at the pulse width modulation (PWM) control layer to guarantee a rapid response. Once an overcurrent caused by severe faults is detected, the proposed control strategy immediately blocks relevant insulated-gate bipolar transistors (IGBTs) using a hysteresis loop, ensuring that the overcurrent is limited within a few PWM cycles. After the fault is cleared, the inverter seamlessly transfers back to droop control mode to maintain stability. The current limiting control has been tested in a microgrid environment operating in the OPAL-RT platform. Study results show that the control strategy can effectively limit the overcurrent under both balanced and unbalanced faults and can maintain system transient stability after the fault is cleared.

Du, Wei↗

Framework for Supporting Adaptive Droop Based Power Electronic Systems

The electric grid is evolving into an electrical network composed of power electronic converters interconnected with renewable and energy storage technologies. This requires the adoption of more advanced control such as volt/var regulation, fast frequency control, and active power frequency response. This work presents a communication and control framework to support dynamically changing droop control segments that can be used for different optimization schemes. Results are presented to work in a controller hardware in the loop testbed.

Starke, Michael↗

A Co-Simulation Framework for Steady-State Analyses of Multiple Droop-based MTdc Grids in Continental-Scale Systems

The growing scale and complexity of planning continental hybrid ac and multi-terminal dc (MTdc) systems require scalable steady-state modeling and analysis approaches not currently available in commercial tools. This paper presents a comprehensive multi-fidelity model-conversion framework that enables the efficient transition of MTdc grid models from production cost modeling (PCM) and approximated ac power flow to detailed ac–MTdc power flow for large-scale planning studies. The core of this framework is a scalable co-simulation approach that, for the first time, enables power flow analysis in continental-scale ac–MTdc systems. It seamlessly couples commercial ac solvers with a detailed MTdc grid model that incorporates droop-based control and current-limiting strategies of multiple meshed MTdc grids. Leveraging this capability, an evaluation framework to systematically assess and compare different MTdc power redispatch strategies under ac and dc contingencies is introduced. The proposed framework and algorithm are evaluated using a combined Western and Eastern Interconnection system with 11 MTdc grids of various sizes, showing a coherent transition from PCM to detailed ac–MTdc power flow and improved system performance in voltage regulation and line overload mitigation following typical contingencies.

Nguyen, Quan H.↗

Optimal Droop Setting for Congestion Reduction in a 100% Grid-Forming Inverter-based Power System

he high penetration of inverter-based resources (IBRs) introduces new challenges to power systems due to the complex inverter control. However, IBRs can be configured to maximize their benefits to improve system resilience and reliability. This paper proposes a steady-state optimization model that aims to mitigate transmission congestion in a 100% grid- forming (GFM) IBR-based power system. This goal is achieved by determining the optimal droop settings for the GFM IBRs under different congestion conditions due to renewable energy and load variations. The numerical solution is rigorously verified by a high-fidelity model of the IEEE 39-bus test system with detailed GFM IBR control in the time-domain electromagnetic transient (EMT) simulation tool PSCAD. The numerical solution and simulation results show a significant congestion reduction while meeting all other operating requirements. It is also observed that the numerical solving time is substantially less compared to the EMT simulation time.

Nguyen, Quan H.↗

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad↗

Generator Frequency Response Droop Monitoring Tool

Monitoring and analyzing the frequency response performance of power generation units is essential for maintaining reliable and secure power system operation. To address this need, an automation tool has been developed to provide a pipeline for processing historical power plant generation data, including large-scale SCADA archives. The tool performs end-to-end processing, including event detection, frequency response (FR) analysis in accordance with NERC standards, and estimation of speed governor droop characteristics. The tool is designed with a modular architecture, allowing individual components of the workflow to be extended, customized, or deployed independently. In addition, the tool provides an API that enables seamless integration with other production systems and operational analytics platforms.

Etingov, PavelV [Pacific Northwest National Labora↗

Model Specification of Droop-Controlled, Grid-Forming Inverters (REGFM_A1)

This document describes a positive-sequence model of droop-controlled, grid-forming (GFM) inverter-based resources (IBRs). It can be considered as an initial model for evaluating the impacts of GFM IBRs on the transients and dynamics of transmission systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Disturbance Propagation Stability in Droop-Controlled Microgrids

The disturbance response of the angle dynamics for a droop-controlled islanded microgrid is characterized. Specifically, a notion of propagation stability is defined, which is concerned with spatial attenuation vs amplification of input- output responses in the network in a H8 or H2 sense. Criteria for propagation stability are developed, phrased in terms of the microgrid’s inverter control parameters. The input frequency range over which the network is susceptible to amplification is also characterized, in the case that the criteria are not met. Based on the formal analysis, a the design of resilient controls that trade off coherence and disturbance propagation goals is briefly conceptualized. Finally, the propagation stability analysis is illustrate using a 15-bus example microgrid network.

Roy, Sandip↗