Search NASA⌕ Search

SEARCH · Search NASA

Results for “elution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Synthesis of polyformals

Formals of CH2OH(CHOH) sub n CH2OH polyols (n = 2 to 4) are prepared in less than 15 minutes by heating to about 125 C, a mixture of e.g. sorbitol and paraformaldehyde in slight excess (5 to 10%), in the presence of e.g. sulfuric acid in catalytic quantities. Elution with methanol and filtration yield the pure solid cyclic triformal. The process can be carried in stages, using almost stoichiometric quantities of paraformaldehyde, but without any change in overall heating time.

Poshkus, A. C.↗

Quantitative separation of tetralin hydroperoxide from its decomposition products by high performance liquid chromatography

A method for the separation and analysis of tetralin hydroperoxide and its decomposition products by high pressure liquid chromatography has been developed. Elution with a single, mixed solvent from a micron-Porasil column was employed. Constant response factors (internal standard method) over large concentration ranges and reproducible retention parameters are reported.

Worstell, J. H.↗

Neurotrophic factor - Characterization and partial purification

Recent evidence suggests that neurotrophic activity is required for the normal proliferation and development of muscle cells. The present paper reports a study of the purification and characterization of a neurotrophic factor (NTF) from adult chicken ischiatic-peroneal nerves using two independent quantitative in vitro assay systems. The assays were performed by the measurement of the incorporation of tritiated thymidine or the sizes of single-cell clones by chick muscle cells grown in culture. The greatest amount of neutrotrophic activity is found to be extracted at a pH of 8; aqueous suspensions of the activity are stable to long-term storage at room temperature. The specific activity of the substance is doubled upon precipitation with ammonium sulfate or after gel filtration, and increase 4 to 5 fold after salt gradient elution from DEAE cellulose columns. The active fraction obtained after gel filtration and rechromatography on DEAE cellulose exhibits a 7 to 10-fold increase in specific activity. Electrophoresis of the most highly purified material yields a greatly concentrated band at around 80,000 daltons. Although NTF is purified almost 10-fold as indicated by the increase in specific activity, the maximum activity of the partially purified material is greatly reduced, possibly due to a requirement for a cofactor for the expression of maximum activity.

Popiela, H.↗

Chlorophyll and carotenoid pigments of prochloron (prochlorophyta)

High-performance liquid chromatography (HPLC) with a gradient-elution technique was utilized to separate and quantify chlorophylls a and b as well as major carotenoid pigments present in freeze-dried preprations of prochloron-didemnid associations and in Prochloron cells separated from host colonies. Results confirm earlier spectrophotometric evidence for both chlorophylls a and b in this prokaryote. Chlorophyll a:b ratios range from 4.14 to 19.71; generally good agreement was found between ratios determined in isolated cell preprations and in symbiotic colonies (in hospite). These values are 1.5 to 5-fold higher than ratios determined in a variety of eukaryotic green plants. The carotenoids in Prochloron are quantitatively and qualitatively similar to those found in various freshwater and marine blue-green algae (cyanopbytes) from high-light environments. However, Prochloron differs from cyanophytes by the absence of myxoxanthophyll and related glycosidic carotenoids. It pigment characteristics are considered sufficiently different from those of cyanophytes to justify its assignment to a separate algal division.

Paerl, H. W.↗

Direct coupling of microbore HPLC columns to MS systems

A detailed investigation using electron microscopy was conducted which examined the conditions of materials used in the construction of stable, high performance microbore liquid chromatography (LC) columns. Small details proved to be important. The effects of temperature on the elution of several homologous series used as probe compounds was examined in reverse phase systems. They showed that accessible temperature changes provide roughly half the increase in solvent strength that would be obtained going from a 100% aqueous to a 100% organic mobile phase, which is sufficient to warrant their use in many analyses requiring the use of gradients. Air circulation temperature control systems provide the easiest means of obtaining rapid, wide range changes in column temperature. However, slow heat transfer from the gas leads to thermal nonuniformity in the column and a decrease in resolution as the temperature program progresses.

Mcnair, H. M.↗

multiplex gas chromatography: A novel analytical technique for future planetary studies

Determination of molecular species comprised of the biogenic elements in the atmospheres of planets and moons of the solar system is one the foremost requirements of the exobiologist studying chemical evolution and the origin of life. Multiplex chromatography is a technique where many samples are pseudo-randomly introduced to the chromatograph without regard to elution of preceding components. The resulting data are then reduced using mathematical techniques such as cross correlation or Fourier Transforms. To demonstrate the utility of this technique for future solar system exploration, chemical modulators were developed. Several advantages were realized from this technique in combination with these modulators: improvement in detection limits of several orders of magnitude, improvement in the analysis of complex mixtures by selectively modulating some of the components present in the sample, increase in the number of analyses that can be conducted in a given period of time, and reduction in the amount of expendables needed to run an analysis. In order to apply this technique in a real application, methane in ambient air was monitored continuously over a period of one week. By using ambient air as its own carrier all expendables beyond power were eliminated.

Valentin, J. R.↗

Inverse gas chromatography. V - Computer simulation of diffusion processes on the column

The elution behavior of low molecular weight probes on inverse gas chromatography (IGC) columns is simulated using a computer. The IGC model is based on a polymer stationary phase of uniform thickness with a nonnegligible resitance to probe penetration. Three characteristic numbers are found to determine the whole process: Z(p) characterizing the distribution of the probe between phases, Z(f) describing the diffusion in the polymer phase, and Z(g) related to diffusion in the gaseous phase. For situations when Z(p)/Z(f) is less than 2, the standard evaluation procedures are virtually useless. The actual behavior of such systems is described.

Hattam, Paul↗

Ionic binding properties of carrier ampholytes

Radioactive ampholytes were synthesized with specific activity of 638 microCi/g. These were used in studies of ampholyte binding to target proteins under nonionic conditions. These radioactive ampholytes bound to target proteins but were dissociable in sodium chloride solutions with dissociation occurring in a concentration dependent way. The ampholytes could be dissociated from target molecules using excess unlabelled ampholytes synthesized in the laboratory as well as commercial ampholytes. Radioactive ampholytes were bound to target proteins with different isoelectric points, and the bound ampholytes were eluted and analyzed by recycling isoelectric focusing. The results showed that acidic proteins bound basic ampholytes and basic proteins bound acidic ampholytes.

Rodkey, L. Scott↗

The Chemical Basis for the Origin of the Genetic Code and the Process of Protein Synthesis

A model for the origin of protein synthesis. The essential features of the model are that 5'-AMP and perhaps other monoribonucleotides can serve as catalysts for the selective synthesis of L-based peptides. A unique set of characteristics of 5'-AMP is responsible for the selective catalysts and these characteristics are described in detail. The model involves the formation of diesters as intermediates and selectivity for use of the L-isomer occurs principally at the step of forming the diester. However, in the formation of acetyl phenylalanine-AMP monoester there is a selectivity for esterification by the D-isomer. Data showing this selectivity is presented. This selectivity for D-isomer disappears after the first step. The identity was confirmed of all four of possible diesters of acetyl-D- and -L phenylaline with 5'-AMP by nuclear magnetic resonance (NMR). The data using flourescence and NMR show the Trp ring can associate with the adenine ring more strongly when the D-isomer is in the 2' position than it can when in the 3' position. These same data also suggest a molecular mechanisim for the faster esterificaton of 5'-AMP by acetyl-D-phenylaline. Some new data is also presented on the possible structure of the 2' isomer of acetyl-D-tryptophan-AMP monoester. The HPLC elution times of all four possible acetyl diphenylalanine esters of 5'-AMP were studied, these peptidyl esters will be products in the studies of peptide formation on the ribose of 5'-AMP. Other studies were on the rate of synthesis and the identity of the product when producing 3'Ac-Phe-2'tBOC-Phe-AMP diester. HPLC purification and identification of this product were accomplished.

Lacey, James C., Jr.↗

Identification of the methylhopanes in sediments and petroleum

Three C31 mehylhopanes were synthesized from diplopterol and its 2-alpha-methyl (Me), 2-beta-Me, and 3-beta-Me analogs. These synthetic methylhopanes were then compared with hopanoids from a variety of bitumens by means of gas chromatography and mass spectrometry, demonstrating that all three C31 hydrocarbons may occur in the ancient sediments. The most common type of hopanes, which eluted very close to the corresponding hopane in the mature sediments and oils was the 2-alpha-Me series.

Summons, Roger E.↗

Gas chromatographic concepts for the analysis of planetary atmospheres

Over the last few years, new gas chromatographic (GC) concepts were developed for use on board spacecraft or any other restricted environments for determining the chemical composition of the atmosphere and surface material of various planetary bodies. Future NASA Missions include an entry probe that will be sent to Titan and various spacecraft that will land on Mars. In order to be able to properly respond to the mission science requirements and physical restrictions imposed on the instruments by these missions, GC analytical techniques are being developed. Some of these techniques include hardware and mathematical techniques that will improve GC sensitivity and increase the sampling rate of a GC descending through a planetary atmosphere. The technique of Multiplex Gas Chromatography (MGC) is an example of a technique that was studied in a simulated Titan atmosphere. In such an environment, the atmospheric pressure at instrument deployment is estimated to be a few torr. Thus, at such pressures, the small amount of sample that is acquired might not be enough to satisfy the detection requirements of the gas chromatograph. In MGC, many samples are pseudo-randomly introduced to the chromatograph without regard to elution of preceding components. The resulting data is then reduced using mathematical techniques such as cross-correlation of Fourier Transforms. Advantages realized from this technique include: improvement in detection limits of several orders of magnitude and increase in the number of analyses that can be conducted in a given period of time. Results proving the application of MGC at very low pressures emulating the same atmospheric pressures that a Titan Probe will encounter when the instruments are deployed are presented. The sample used contained hydrocarbons that are expected to be found in Titan's atmosphere. In addition, a new selective modulator was developed to monitor water under Martian atmospheric conditions. Since this modulator is selective only to water, the need for a GC column is eliminated. This results in further simplification of the instrument.

Valentin, J. R.↗

Assessment of effects on vegetation of degradation products from alternative fluorocarbons

Concern with the effects of fluorides on plants has been devoted to that resulting from dry deposition (mainly with reference to gaseous HF and secondarily with particulate forms). The occurrence of precipitation as rain or mist and the presence of dew or free water on the foliage has mainly been considered with respect to their effects on the accumulation of air-borne fluoride and not with fluoride in wet deposition. That is, precipitation has been viewed primarily with respect to its facilitation of the solution and subsequent absorption of deposits by the foliar tissues or its elution of deposited fluoride from foliage. Accordingly, our evaluation of inorganic fluoride from fluorocarbon degradation rests upon a comparison with what is known about the effects of industrial emissions and what could be considered the natural condition.

Mccune, D. C.↗

Development of a miniaturized gas chromatograph-mass spectrometer with a microbore capillary column and an array detector

A review is presented of the demonstration of a miniaturized focal plane mass spectrograph using a microbore capillary column with an array detector to measure multiple mass spectra from narrow and closely eluted gas chromatograph peaks. It is shown that the system possesses high sensitivity and a high speed of spectral mass measurements. The combination of the capillary column with the miniaturized mass spectrograph is uniquely suited for the development of a field-portable, high-performance system.

Sinha, Mahadeva P.↗

A volatile organic analyzer for Space Station: Description and evaluation of a gas chromatography/ ion mobility

A Volatile Organic Analyzer (VOA) is being developed as an essential component of the Space Station's Environmental Health System (EHS) air quality monitoring strategy to provide warning to the crew and ground personnel if volatile organic compounds exceed established exposure limits. The short duration of most Shuttle flights and the relative simplicity of the contaminant removal mechanism have lessened the concern about crew exposure to air contaminants on the Shuttle. However, the longer missions associated with the Space Station, the complex air revitalization system and the proposed number of experiments have led to a desire for real-time monitoring of the contaminants in the Space Station atmosphere. Achieving the performance requirements established for the VOA within the Space Station resource (e.g., power, weight) allocations led to a novel approach that joined a gas chromatograph (GC) to an ion mobility spectrometer (IMS). The authors of this paper will discuss the rational for selecting the GC/IMS technology as opposed to the more established gas chromatography/mass spectrometry (GC/MS) for the foundation of the VOA. The data presented from preliminary evaluations will demonstrate the versatile capability of the GC/IMS to analyze the major contaminants expected in the Space Station atmosphere. The favorable GC/IMS characteristics illustrated in this paper included excellent sensitivity, dual-mode operation for selective detection, and mobility drift times to distinguish co-eluting GC peaks. Preliminary studies have shown that the GC/IMS technology can meet surpass the performance requirements of the Space Station VOA.

Limero, Thomas F.↗

DNA-DSB in CHO-K1 cells induced by heavy-ions: Break rejoining and residual damage (GSI)

DNA double strand breaks (DSB's) are the critical lesions involved in cellular effects of ionizing radiation. Therefore, the evaluation of DSB induction in mammalian cells after heavy ion irradiation is an essential task for the assessment of high-LET radiation risk in space. Of particular interest has been the question of how the biological efficiency for the cellular inactivation endpoint relates to the initial lesions (DSBs) at varying LETs. For cell killing, an increased Relative Biological Efficiency (RBE) has been determined for highLET radiation around 100-200 keV/mu m. At higher LET, the RBE's decrease again to values below one for the very heavy particles. At GSI, DSB-induction was measured in CHO-K1 cells following irradiation with accelerated particles covering a wide LET range. The electrophoretic elution of fragmented DNA out of agarose plugs in a constant electrical field was applied for the detection of DSB's. The fraction of DNA retained was determined considering the relative intensities of ethidium bromide fluorescence in the well and in the gel lane. Dose-effect curves were established, from which the RBE for DSB induction was calculated at a fraction of 0.7 of DNA retained In summary, these rejoining studies are in line with an enhanced severity of the DNA DSB's at higher LET's, resulting in a decreased repairability of the induced lesions. However, no information concerning the fidelity of strand breaks rejoining is provided in these studies. To assess correct rejoining of DNA fragments an experimental system involving individual DNA hybridization bands has been set up. In preliminary experiments Sal I generated DNA fragments of 0.9 Mbp were irradiated with xrays and incubated for repair However, restitution of the original signals was not observed, probably due to the high radiation dose necessary for breakage of a fragment of this size. A banding pattern with NotI hybridization signals in a higher MW range (3Mbp) has been obtained by varying the electrophoretic conditions and correct rejoining studies will be further developed in this system.

Taucher-Scholz, G.↗

A redox beginning: Which came first phosphoryl, acyl, or electron transfer ?

Thermodynamic and kinetic information available on the synthesis of prebiotic monomers and polymers will be examined in order to illuminate the prebiotic plausibility of polymer syntheses based on (a) phosphoryl transfer that yields phosphodiester polymers, (b) acyl transfer that gives polyamides, and (c) electron transfer that produces polydisulfide or poly(thio)ester polymers. New experimental results on the oxidative polymerization of 2,3-dimercaptopropanol by ferric ions on the surface of ferric hydroxide oxide will be discussed as a chemical model of polymerization by electron transfer. This redox polymerization that yields polymers with a polydisulfide backbone was found to give oligomers up to the 15-mer from 1 mM of 2,3-dimercaptopropanol after one day at 25 C. High pressure liquid chromatography (HPLC) analysis of the oligomers was carried out on an Alltech OH-100 column eluted with acetonitrile-water.

Weber, Arthur L.↗

Observations and Modeling of the Transient General Circulation of the North Pacific Basin

The objective of this study was to clarify the role that interstellar-cloud chemistry played in forming the population of organic molecules presently found in carbonaceous meteorites. This goal was to be achieved by means of defining the isotopic components present in organic and related phases in the meteorites and thereby identify the processes and source reservoirs involved in organic synthesis in the early solar system. Isotopic analysis of separated amino acids from the Murchison meteorite yielded results that are complex and not fully interpretable at this time. Substantial inter-acid variability in D/H ratio was observed, some but not all of which could be attributed to exchange with terrestrial hydrogen. Pronounced, though smaller, variability was also found for N-15/N-14 ratios. For both D/H and N-15/N-14 data, observed meteoritic values were substantially greater than found in terrestrial materials, providing a robust constraint on degrees of possible terrestrial contamination. Also, C-13/C-12 ratios, though falling within the range of data found on earth, significantly exceeded those characteristic of naturally occurring terrestrial amino acids. Inter-acid variability in C-13/C-12 ratios was muted relative to that observed for D/H and N-15/N-14 but still lay well outside of experimental uncertainty. No systematic relationship could be observed between variations in H, C and N isotopes. Two anomalous components were also found during the course of this study. A highly (greater than 6% relative to terrestrial) N-15-depleted, N-rich compound, which has not yet been identified, co-eluted with some amino acids. Clearly the Murchison meteorite sampled nitrogen from a number of highly diverse isotopic reservoirs. In fact, from this and related studies, it is now apparent that the distribution of nitrogen isotopes in the primitive solar system was extremely inhomogeneous. The second anomalous result obtained in the present study was for an extract of 'ammonia' from Murchison. It should be noted that this sample consisted of ammonia that was probably derived from a number of different compounds present in the meteorite itself, possibly including amines and amides, as well as ammonia sensu strictu and ammonium slats. However, the significance of this analysis is that the N-15/N-14 ratio measured was much lower than those found for the meteoritic amino acids (+2% vs around + 9% relative to terrestrial). This raises an important question concerning the source of the ammonia that was involved in synthesis of the amino acids. This issue needs to be explored further.

Kerridge, John F.↗

The Determination of Atmospheric Fluoride with a Specific Ion Electrode

Atmospheric fluoride is collected on lime-coated filter paper exposed to the ambient atmosphere for 30-day periods. The fluoride is eluted from the paper and analyzed with the use of a fluoride specific ion electrode. The technique permits evaluation of potential fluoride sources in terms of downwind concentrations and provides a simple, rapid procedure for the analysis of large numbers of samples.

Feldstein, M.↗