Search NASASearch

SEARCH · Search NASA

Results for “epitaxial growth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

46 records · Page 3

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

WINDSAT Free Flyer Using the Advanced TIROS-N Satellite

The results of this study show the feasibility of carrying a wind measuring lidar on an ATN-derivative free flying spacecraft. The overall configuration fits within the Shuttle bay and uses the same techniques for STS Launch as the proposed SAATN spacecraft. The lidar can be made light enough that the total weight of the satellite is well within the capability of the onboard propulsion system for transfers to a Sun synchronous orbit at 833 km attitude. The principal techniques for weight minimization are the use of the Perkin Elmer proprietary HIP process for the telescope, new packaging concepts for the laser and for the optics-laser interface, and the application of current technology to the signal processing hardware. Power minimization is achieved for the lidar primarily by use of a low pulse repetition frequency, i.e., 2pps, and again by the use of current processor technology. The power capability of the spacecraft is enhanced by increasing the ATN array size 25 percent, through the addition of two more solar array panels of the present size, and by limiting the range of Sun angles over which the spacecraft is operated. The same basic concept for the lidar as proposed in the Shuttle Windsat study is recommended here, but there are some changes in details to improve weight and power. No major technology break-throughs are required for the lidar, but some technology experiments are recommended for the laser subsystem to verify isotopic gas lifetime and performance, modulator life and weight, and for space qualification. Spacecraft changes are all natural modifications or growth to accommodate the payload. Overall, the proposed system provides substantial margin for the uncertainties for the future and for potential payload change, and also demonstrates the reasonableness of the Windsat Free Flyer concept.

Herbert M Gurk

Optical properties of morphologically complex black carbon aerosols: Effects of coatings

Optical properties are computed for fractal-like aggregate black carbon (BC) aerosols coated with different substances. Two models are used for these aerosols: (i) the coated aggregate model (model I), where coating is added to the voids and surroundings of BC fractal-like aggregates; and (ii) the closed-cell aggregate model (model II), where coating is added concentrically to each monomer of BC fractal-like aggregates. Our results favor choosing the coated aggregate model (model I) to simulate scattering and absorption by coated BC aerosols because this model is morphologically more realistic, and because this model yields mass absorption cross section (MAC) and backscattering linear depolarization ratio (LDR) values that are consistent with field measurements. Moreover the corresponding computed degree of linear polarization (DoLP) and LDR values are very sensitive to changes in the coating volume fraction (fvol) and the coating refractive index (m). With the same absorbing BC core, the MAC value increases steadily with increasing fvol and m values. For example, using a density of 1.8 g/cm 3 and BC refractive index 1.95 + i0.79, the calculated MAC values for uncoated BC aggregates range from 6.2 to 6.8 m 2 /g at 0.55 µm. When coating material is applied to the BC aggregates, the calculated MAC values for model I particles increase to between 9.8 and 13.2 m 2 /g (depending on m) when fvol = 87.5%. The backscattering LDR values also tend to increase with the increasing m values for the shapes and sizes considered in our study. For model I particles, the backscattering LDR values span a wide range of 4.2–27.8% at a wavelength of 0.35 µm at fvol = 87.5% when m increases from 1.33 to 1.55. Our results are relevant to analyses of polarimetric and lidar observations of smoke particles, especially when these particles undergo hygroscopic growth.

Black carbon aerosols

Polymer Composite Material Testing for a Cryotank Application

Composite cryotanks will play a key role in enabling the next generation of efficient aircraft. Carbon fiber reinforced polymer (CFRP) composites have the benefits of reduced weight and potentially higher structural strength compared to traditional metallic fuel tanks. A material screening study was conducted to inform material selection for liquid hydrogen (LH2) fuel storage. Three composite materials were considered because of their aerospace grade toughness, strength, and existing data to compare against. These materials were a thermoplastic low-melt polyaryletherketone (LM-PAEK)/carbon fiber (CF), thermoset/CF, and hybrid thermoset/thermoplastic polyurethane (TPU) veil/CF composite. Mechanical screening tests included tension, compression, in-plane shear (IPS), and tensile-tensile fatigue (TTF). Each material was tested at both a baseline (no liquid nitrogen/LN2 cycling) and 100 LN2-cycled conditions to determine the knockdown factor, if any, of each material when exposed to environmental loading effects in a cryotank. Results show minimal effects of the LN2-cycling compared against baseline values. The three materials behaved similarly in tension; however, the thermoplastic/CF had the highest IPS toughness. The hybrid thermoset/TPU/CF composite had the lowest IPS strength, compressive strength, and toughness. LN2-cycling had minimal effects on tensile-tensile fatigue performance of the thermoplastic/CF material. Mechanical data was captured to guide material down selection for future commercially viable hydrogen aircraft design. In its current state, there does not exist a consolidated, publicly available database for CFRP composite material performance data at cryogenic temperatures. The next step in this work is to test the thermoplastic and thermoset CFRP composites, as well as the neat resins, at LH2 relevant temperature (20 K) to capture this crucial material property data. These results are essential to inform cryotank design and modeling efforts. The process to start this next round of testing has begun. Planned mechanical tests include toughness (single-edge notched beam), tension (unidirectional and quasi-isotropic), thermal expansion, and thermal conductivity. Some tests will also be conducted at an intermediate temperature of 111 K relevant to liquid natural gas (LNG), another attractive fuel choice. The ultimate goal is to manufacture a sub-scale cryotank part that can pass relevant burst, fatigue, permeation, and thermal cycling tests. This work is a part of NASA’s Commercially viable Hydrogen Aircraft for Robust Growth in Efficiency (CHARGE) Project under the larger NASA Subsonic Vehicle Technologies and Tools (SVTT) Project.

composites

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

RTV

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

silicone intumescence

Ultra-High-Temperature Ceramics Evaluated for Aeropropulsion Use

Ultra-high-temperature ceramics (UHTC) are a group of materials consisting of zirconium diboride (ZrB2) or hafnium diboride (HfB2) plus silicon carbide (SiC), and in some instances, carbon (C). They offer a combination of properties that make them candidates for airframe leading edges on sharp-bodied reentry vehicles. These UHTCs perform well in the environment for such applications (i.e., air at low pressures). The purpose of this study at the NASA Glenn Research Center was to examine three of these materials under conditions more representative of a propulsion environment: that is, higher oxygen partial pressure and total pressure. Relatively long, multiple-exposure cycles were emphasized. We completed an in-house study of ZrB2 plus 20 vol% SiC (abbreviated as ZS), ZrB2 plus 14 vol% SiC and 30 vol% C (ZSC), and SCS-9a SiC fiber-reinforced ZrB2 plus 20 vol% SiC (ZSS). HfB2-based compositions were not included in the study because of their high cost. The capability of UHTC for propulsion applications must be compared with that of mature, available, and commercially used ceramics such as silicon nitride (e.g., AS-800) to put things in proper perspective. In terms of mechanical properties, UHTCs fall short in terms of strength and fracture toughness. At about 1300 C, the creep resistance of ZS appears to be superior to the creep resistance reported for AS-800. However, the stress rupture life for Si3N4 under stress and temperature conditions similar to those used in this study is measured in hundreds of hours. Because of oxidation, ZS could not achieve such lives. In terms of oxidation resistance, acceptable amounts of material recession in 1 hour to thousands of hours, depending on the specific propulsion application, are on the order of 100 to 300 mm. This converts to an acceptable range of parabolic recession rate constants kp" of approximately less than or equal to 10(exp -1) to 10(exp -2) square millimeters per hour for a 1-hr application. For a 100-hr application, an acceptable range of kp" would be less than or equal to those values divided by 100. For the more oxidation resistant ZS material, measured parabolic recession rate constants were 4.7 x 10(exp -3) millimeters per hour at 1327 C, 7.8 x 10(exp -2) square millimeters per hour at 1627 C, and 1.3 millimeters per hour at 1927 C. Thus, recession rate constants for ZS are acceptable at 1327 C for a 1-hr application, but here silicon nitride is a superior material. At 1627 C, ZS oxidation is marginal for a 1-hr application, but dimensional growth would be an issue. In a 100-hr application, ZS cannot be considered at any temperature. Our cursory examination of thermal shock, both from a theoretical and experimental viewpoint, indicated that the ZS and ZSC UHTCs are inferior to AS-800 silicon nitride. On the basis of this limited study, UHTCs are not ready to be considered as aeropropulsion materials for any applications longer than a few minutes. Current materials suffer from aggressive oxidation and moisture attack (Quynhgiao Nguyen, NASA Glenn, and Raymond C. Robinson, QSS Group, Inc., Cleveland, OH, 2002, private communication), and they are susceptible to thermal shock. For long-term propulsion applications, major improvements in environmental durability are needed. Work is in progress to improve the oxidation resistance of UHTC materials.

Stanley R Levine

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health