Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Reducing Sample Loss in Measurement of Heat of Vaporization of Ethanol/Gasoline Blends by Differential Scanning Calorimetry/Thermogravimetric Analysis

Higher gasoline Heat of Vaporization (HOV) can enable higher compression-ratio direct injection spark ignition engines by providing evaporative cooling that effectively increases fuel knock resistance. Methods to directly measure this fuel property in complex gasoline samples are not well developed. The objective of the present study was to further improve a Differential Scanning Calorimetry/Thermogravimetric Analyzer (DSC/TGA) method to measure the total and partial HOV of gasoline. Ten market gasoline samples were chosen to have a wide range of properties to assess the method's capability across the entire volatility range with an emphasis on understanding how well the method captures the initial 10 percent (%) of sample evaporation and how much sample is left unevaporated at the end of the experiment. Modifications to the sample preparation/introduction method as well as to the instrument itself were made to reduce initial sample losses which included measurements of the HOV at 10 degrees C and 5 degrees C (in a cold chamber) as well as under (uncontrolled) ambient conditions. Experimental results from the DSC/TGA were compared to calculated total HOV results based on Detailed Hydrocarbon Analysis (DHA). Results from the two methods agreed very well with the difference being 5% or less in almost every case. In addition, the repeatability of the method was investigated by analyzing samples in triplicate at the three temperatures investigated. One valuable conclusion from the study was that the lower temperatures of 10 degrees C and 5 degrees C enabled more reproducible measurements for both total and partial HOV. This improved precision may be caused by the fact that temperature control in the cold chamber was more reliable than the ambient laboratory temperature control. Additionally, cold chamber experiments, due to ergonomic limitations, did not allow for the use of a lid on the sample pan. The reproducibility of the evaporation rate was found to be highly dependent on the pan/lid fit which can vary significantly such that elimination of the lid improved measurement precision while operation at sub-ambient temperature slowed the evaporation rate. Results detailing sample preparation and instrument modifications as well as a detailed comparison of total and partial HOV results are presented.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

, Experimental Investigation of Electrically Charged Water Droplets Two-Phase Cross-Flow Interactions with Humid

Electrically charged water droplets can capture water vapor molecules in surrounding moist air and promote vapor condensation. This concept unfolds an alternative to mechanical cooling-based air dehumidification systems that separate sensible and latent cooling loads in HVAC applications. The effect of dielectrophoresis, electro-hydrodynamic, and micro-diffusive flows due to highly electrically charged water droplets traveling through moist air were investigated as new methods to reduce the air’s water vapor content. This paper presents new experimental data on humidification and power consumption for a system consisting of highly energized electrosprays in combination with mist eliminators. Electrosprays produced highly charged water spray cones crossing the air perpendicularly and upwardly. The moist air stream was circulated in a horizontal duct at 22C, 80% relative humidity, and 0.24 ms-1 airspeed. Mist eliminators made of stainless wire clothes of 36 and 25 μm pore diameter were used to screen the droplets growing during their flight trajectory. The mist eliminators blocked some of the largest diameter droplets. Still, they could not prevent re-evaporation of the droplets into the bulk air from the droplets deposited on their wire clothes. The equilibrium between the dielectrophoresis condensation from the electrosprays and the droplets’ re-evaporation phenomena resulted in reduced humidification when compared to conventional-type spray evaporative cooling systems. However, to dehumidify the air, the droplets injected by the electrosprays must be separated entirely and promptly removed from the bulk airflow at the end of their flight trajectory.

Electrostatic droplets, Electrospray, humidificati↗

Trends in best-in-class energy-efficient technologies for room air conditioners

Improving the efficiency of room air conditioners (RACs) could provide significant energy and associated emissions savings, particularly in emerging economies with hot climates where the cooling demand is expected to increase dramatically. To help accelerate efficiency improvements, this study identifies “best-in-class” high-efficiency RAC components and products. The findings show that manufacturers tend to minimize manufacturing costs by using RAC designs that are readily available or standardized to their production, and they share components across various models. High-efficiency RAC models use advanced compressor technologies optimized at a low frequency, large heat exchangers with thermodynamically effective materials and designs, highly efficient direct current fan motors, advanced metering devices, and smart sensors for temperature and humidity control. Recently RAC manufacturers have been improving seasonal efficiency – better reflecting part-load operation – especially via variable-speed (inverter) drives for compressor motors. Recent highest-efficiency RAC models use low global warming potential (GWP) refrigerants, having transitioned from conventional high-GWP refrigerants, in regions where RACs that use these low-GWP refrigerants are commercially available. Recently demonstrated innovative technologies show trends toward smart hybrid designs, evaporative cooling, and solid-state materials beyond the conventional vapor-compression technology. This information could help policymakers improve their RAC market-transformation programs to align with the most-efficient global technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A first and second law analysis of a thermoresponsive polymer desiccant dehumidification and cooling cycle

Herein, we present a theoretical description for a new desiccant air conditioning cycle that uses thermoresponsive polymers instead of traditional desiccants. We use a combined first and second law analysis to demonstrate that this new cycle has three major advantages relative to the traditional case: (i) it can regenerate at lower temperatures, (ii) it can harvest liquid water and (iii) it has significantly higher coefficients of performance (COPs). For example, this new cycle can achieve a COP of 5.1 when regenerated at 95 degrees C, whereas the traditional desiccant cycle is limited to a COP of ~ 1. The fundamental origins of these advantages can be traced to the method of regeneration. The traditional desiccant cycle regenerates by flowing hot air over the desiccant, which provides a medium for gaseous water desorption. However, this also generates entropy and places a minimum temperature constraint on the hot air. In contrast, the thermoresponsive polymer cycle regenerates through a polymer phase transition. The polymer absorbs water vapor in humid air, and then it expels liquid water when raised above its transition temperature. This regeneration method generates liquid water that can be harvested and relaxes constraints on entropy generation and minimum temperature. The minimum regeneration temperature of the thermoresponsive cycle is only limited by the transition temperature of the polymer, which can be tuned through materials science. Due to its liquid water harvesting capability, the new cycle potentially eliminates water consumption when used with evaporative cooling, or it can be directly used for atmospheric water harvesting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

Effects of blending C3-C4 alcohols on motor gasoline properties and performance of spark ignition engines: A review

Supplementing petroleum fuels with sustainable and renewable alternatives is a good option for increasing the sustainability of transportation fuels. Alcohols are particularly attractive blendstocks for spark ignition engines, mainly due to their desirable fuel properties including high octane, evaporative cooling, and reduced sooting propensity. Although the use of SI engines is widespread around the world, predominately for light duty vehicles, concerns about CO2 emissions and other sustainability issues necessitate increased engine efficiencies, reduced tailpipe pollutants, and lower lifecycle carbon emissions. The intelligent blending of C2-C4 alcohols into motor gasoline is a viable method for achieving these goals. There are a multitude of ways to produce renewable alcohols such as through fermentation from first-generation feedstocks (sugar and corn) and second-generation feedstocks (lignocellulosic biomass), or by gasification and mixed alcohol fuel synthesis routes from lignocellulosic biomass. Currently ethanol is extensively used in motor gasoline fuels worldwide and although many have proposed the use of C3 and C4 alcohols in motor gasoline as an improvement over ethanol, the higher cost of production and lack of clear definition as to their benefit over ethanol when blended into motor gasoline have led to slow acceptance into the market. In this review, special emphasis is placed on the effects of blending C3 and C4 alcohols into motor gasoline in terms of physicochemical properties, volatility behavior, and engine performance when compared to ethanol blends. Furthermore, the impact of blending C3 and C4 alcohols with gasoline on emission (particulate matter, nitrogen oxides, carbon monoxide, hydrocarbons, and unregulated oxygenates) and combustion (volumetric efficiency, thermal efficiency, fuel consumption, and cold performance) characteristics is discussed. Although there are some disagreements in the literature over the effect of alcohols predominately around the type of SI engine, i.e., port fuel injected versus direct fuel injected and engine operating mode, generally it is stated that alcohols can potentially reduce soot, unburned hydrocarbons and CO emissions while increasing thermal efficiency when proper engine configuration/calibration is used. Lastly, research that must be conducted to find the optimum combination of alcohol blends and engine configurations is highlighted and discussed.

09 BIOMASS FUELS↗

A unified non-equilibrium phase change model for injection flow modeling

The homogenous relaxation model (HRM) is one of the most widely used models to describe the liquid- gas phase transition. However, in its original formulation, it is unable to handle multispecies vapor-liquid equilibrium (VLE), which limits its applicability to single-component fluids. In this work, a unified non-equilibrium phase change model that considers the VLE of multicomponent mixtures is proposed building upon the HRM's structure. A time factor is introduced to mimic the effect of different phase change timescales due to different mechanisms, e.g., cavitation, flash-boiling, and evaporation. Here to assess the model's performance, computational fluid dynamics simulations of the internal and near-nozzle injection flow of the Engine Combustion Network's Spray G injector were performed using the nine-component PACE-20 fuel with both the unified model and the original HRM. The predicted fuel density in the near-nozzle region matched well with X-ray tomography measurements. The simulation results indicated that, whereas the HRM failed to capture the vaporization due to convective mixing between the fuel and ambient gas, the unified model performed well in predicting the mixing-driven vaporization and the corresponding evaporative cooling. Further comparisons using the nine-component fuel formula and a single-component fuel surrogate demonstrated the unified model's ability to predict preferential vaporization, which affects the predictions of local mixture composition and rate of vaporization. Finally, it is shown that the unified model is capable of representing multiple phase change mechanisms, and the relaxation time factor plays an important role in determining the degree of phase change due to the different mechanisms.

33 ADVANCED PROPULSION SYSTEMS↗

Aridity-Dependent Land Surface Skin Temperature Biases in CMIP5/6

Land surface skin temperature, a critical indicator of climate change, connects the water and energy cycles between the land and the atmosphere. Here, in this study, we evaluate the simulations of land surface skin temperature from the Coupled Model Intercomparison Project Phase 5 (CMIP5) and CMIP6 models with satellite-based datasets and reanalysis. We find systematic cold skin temperature biases over arid regions in CMIP5/CMIP6 simulations. Over arid and semi-arid regions, latent heat biases drive skin temperature biases by evaporative cooling. Over humid regions, surface downward shortwave and albedo biases are relatively more critical. Spatial patterns of biases remain similar in the latest CMIP6 simulations, suggesting systematic biases in land-atmosphere interactions. These biases need to be corrected or considered while using models for future projections.

54 ENVIRONMENTAL SCIENCES↗

The Role of Bjerknes and Shortwave Feedbacks in the Tropical Pacific SST Response to Global Warming

Abstract The evolution of tropical sea surface temperatures (SSTs) in response to greenhouse warming is of great societal and scientific interest. Most state‐of‐the‐art climate models predict a mean “El Niño‐like” warming pattern by century‐end, characterized by greater warming over the Pacific cold tongue compared to the western warm pool. However, it is unclear which proposed mechanism dominates in this response. Here, we present partially coupled abrupt CO 2 doubling experiments in which surface wind stress and shortwave heating are overridden to values from a control simulation. Contrary to previous studies, we find that experiments with overriding of surface wind stress exhibit only 58% of the full reduction in east‐west SST contrast. When both surface wind stress and shortwave flux are overridden, only 34% of the full reduction remains, controlled by spatially‐varying evaporative cooling. These results underscore the importance of Bjerknes and shortwave feedbacks in the tropical Pacific SST response to global warming.

Geology↗

Cellular fluidics

The natural world provides many examples of multiphase transport and reaction processes that have been optimized by evolution. These phenomena take place at multiple length and time scales and typically include gas–liquid–solid interfaces and capillary phenomena in porous media. Many biological and living systems have evolved to optimize fluidic transport. However, living things are exceptionally complex and very difficult to replicate, and human-made microfluidic devices (which are typically planar and enclosed) are highly limited for multiphase process engineering. In this paper, we introduce the concept of cellular fluidics: a platform of unit-cell-based, three-dimensional structures—enabled by emerging 3D printing methods—for the deterministic control of multiphase flow, transport and reaction processes. We show that flow in these structures can be ‘programmed’ through architected design of cell type, size and relative density. We demonstrate gas–liquid transport processes such as transpiration and absorption, using evaporative cooling and CO 2 capture as examples. We design and demonstrate preferential liquid and gas transport pathways in three-dimensional cellular fluidic devices with capillary-driven and actively pumped liquid flow, and present examples of selective metallization of pre-programmed patterns. Our results show that the design and fabrication of architected cellular materials, coupled with analytical and numerical predictions of steady-state and dynamic behaviour of multiphase interfaces, provide deterministic control of fluidic transport in three dimensions. Cellular fluidics may transform the design space for spatial and temporal control of multiphase transport and reaction processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray photoelectron spectroscopy of surfactants on sub-micron aqueous aerosols

Organic molecules at the aqueous interfaces of droplets and aerosols can influence multiphase chemistry and cloud condensation nuclei activity. While surface tension measurements on flat surfaces are commonly used to quantify organic partitioning and structure, extending these measurements to more realistic aerosols that might exist in metastable, supercooled and supersaturated states remains a challenge. Here, we use aerosol velocity map imaging X-ray photoelectron spectroscopy (A-VMI-XPS), a surface-sensitive and in situ technique, to study the partitioning and structure of a model surfactant (n-octyl β-D-thioglucopyranoside, OTG) in submicron aqueous aerosols with a mean radius of 116 nm. After accounting for finite size effects and evaporative cooling, we find the bulk concentrations of OTG in the aerosol are depleted 600-fold relative to macroscopic solutions. At the low temperatures of the experiment (ca. ∼188 K), we obtain a Langmuir equilibrium constant of 700 m3 mol-1, which corresponds to 4.9 m3 mol-1 at room temperature; a value that is consistent with prior literature reports. Analysis of photoelectron angular distributions, peak areas, and secondary electron escape barriers indicates a transition from a disordered surfactant layer at low [OTG] to a more structured layer at high [OTG]. These results link macroscopic surface tension measurements to nanoparticle surfactant behavior and demonstrate the utility of A-VMI-XPS in probing surfactant coating structure on free aerosols, with implications for understanding the impact of organic coatings on cloud formation and atmospheric chemistry.

Deal, Alexandra M↗

Enhancement and maximum in the isobaric specific-heat capacity measurements of deeply supercooled water using ultrafast calorimetry

Knowledge of the temperature dependence of the isobaric specific heat (C p ) upon deep supercooling can give insights regarding the anomalous properties of water. If a maximum in C p exists at a specific temperature, as in the isothermal compressibility, it would further validate the liquid–liquid critical point model that can explain the anomalous increase in thermodynamic response functions. The challenge is that the relevant temperature range falls in the region where ice crystallization becomes rapid, which has previously excluded experiments. Here, we have utilized a methodology of ultrafast calorimetry by determining the temperature jump from femtosecond X-ray pulses after heating with an infrared laser pulse and with a sufficiently long time delay between the pulses to allow measurements at constant pressure. Evaporative cooling of ~15-µm diameter droplets in vacuum enabled us to reach a temperature down to ~228 K with a small fraction of the droplets remaining unfrozen. We observed a sharp increase in C p , from 88 J/mol/K at 244 K to about 218 J/mol/K at 229 K where a maximum is seen. The C p maximum is at a similar temperature as the maxima of the isothermal compressibility and correlation length. From the C p measurement, we estimated the excess entropy and self-diffusion coefficient of water and these properties decrease rapidly below 235 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal stress in degraded forests in the Brazilian Amazon Arc of Deforestation

Understanding thermal stress in tropical forests has taken on new urgency in light of accelerating climate change and expansion of deforestation and forest degradation. Degraded tropical forests in particular may be approaching critical temperature thresholds even more rapidly than intact forests, with implications for tree survival and ecosystem recovery. We investigate thermal stress in degraded tropical forests within the Brazilian Amazon Arc of Deforestation. Using land surface temperature data from the ECOsystem Spaceborne Thermal Radiometer Experiment on the international Space Station (ECOSTRESS), we compared canopy temperatures of intact, selectively logged, and burned forests in Feliz Natal, Mato Grosso, Brazil. Upper canopy temperatures in previously burned forests were 4.1% higher (mean = 36.5 °C) and 50.9% more variable compared to intact and logged forests, which showed remarkably similar temperature distributions (means of 34.9 °C and 35.1 °C, respectively). Modeled leaf temperature distributions based on canopy temperature measurements from one of the warmest days in a 2 year dry season record indicated that 87% of leaves in the warmest burned forest patches exceeded the temperature threshold where respiration surpasses photosynthesis, compared to approximately 72%–74% in intact and logged forests, respectively, in the same time period. After controlling for environmental factors, burned forests were predicted to be 2.6 °C warmer on average [1.39 °C–3.96 °C, 95% credible interval] than intact forests across a 5–40 m canopy height range. Burned forests showed modest thermal recovery over time, with temperatures decreasing by approximately 1.2 °C over a 30 year recovery period. In contrast, logged forests showed minimal thermal differences from intact forests (−0.353 on average, [−1.125–0.274, 95% credible interval]) and negligible change (0.15 °C) over the same timeframe. While the absolute probabilities of exceeding damaging thermal thresholds remain low across all forest types under current climate conditions, the probability of leaves exceeding temperatures that cause permanent leaf damage was ten times higher in burned forests, with implications for the future of burned forest regeneration in water-limited regions of the Amazon basin. In particular, the combination of higher mean temperatures, greater temperature variability, and more frequent exposure to damaging thermal thresholds implies that burned tropical forests will experience substantially higher mortality rates and slower biomass recovery compared to intact and selectively logged forests, especially in water-limited regions where trees cannot rely on evaporative cooling to moderate canopy temperatures.

Brazilian Amazon Arc of Deforestation↗

Quantum-State-Controlled Collisions of Ultracold Polyatomic Molecules

Collisions between ultracold calcium monohydroxide (CaOH) molecules are realized and studied. Inelastic collision rate constants are measured for CaOH prepared in ground and excited vibrational states, and the electric field dependence of these rates is measured for molecules in single quantum states of the parity-doubled bending mode. Theoretical calculations of collision rate coefficients are performed and found to agree with measured values. The lowest collisional loss rates are for states with repulsive long-range potentials that shield ultracold molecules from loss channels at short distance. These results unveil the collisional behavior of parity-doublet molecules in the ultracold regime and lay the foundation for future experiments to evaporatively cool polyatomic molecules to quantum degeneracy.

Vilas, Nathaniel B. [Harvard University, Cambridge↗

Virus-induced gene editing of stomatal regulators in Nicotiana benthamiana enables rapid functional genomics

Virus-induced gene editing (VIGE) holds promise as a rapid and scalable approach for functional genomics in plants. Here, we apply a tobacco rattle virus (TRV)-based single-guide RNA (sgRNA) delivery system to target key regulators of stomatal development in Nicotiana benthamiana using transgenic Cas9-expressing lines. sgRNAs fused to a mobile RNA element and co-delivered with TRV enabled both somatic and heritable genome editing across orthologs of STOMAGEN, EPF2, YODA, and SPEECHLESS. Somatic editing frequencies reached up to 95%, and heritable tetra-allelic mutations were recovered in multiple target genes. Mutants exhibited significant, gene-specific changes in stomatal density, with corresponding effects on leaf temperature indicative of altered evaporative cooling. Additionally, sgRNAs fused to an AmCyan reporter enabled visualization of virus-infected tissues, allowing stomatal phenotyping in edited M0 sectors. This TRV-based platform facilitates functional assessment of genes influencing stomatal patterning and offers a powerful tool for dissecting gene function in a developmentally and physiologically relevant context.

60 APPLIED LIFE SCIENCES↗

Observation of microwave shielding of ultracold molecules

Harnessing the potential wide-ranging quantum science applications of molecules will require control of their interactions. Here, we used microwave radiation to directly engineer and tune the interaction potentials between ultracold calcium monofluoride (CaF) molecules. By merging two optical tweezers, each containing a single molecule, we probed collisions in three dimensions. The correct combination of microwave frequency and power created an effective repulsive shield, which suppressed the inelastic loss rate by a factor of six, in agreement with theoretical calculations. The demonstrated microwave shielding shows a general route to the creation of long-lived, dense samples of ultracold polar molecules and evaporative cooling.

Anderegg, Loïc↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗