Search NASA⌕ Search

SEARCH · Search NASA

Results for “geothermal system costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

3D Play Fairway Analysis for Examining of Superhot Reservoir Production Scenarios

The DEEPEN (DE-risking Exploration for geothermal Plays in magmatic ENvironments) project was a multi-laboratory, international effort to reduce uncertainty and improve resource characterization in superhot geothermal systems. Building on this foundation, this work advances open-source tools designed to lower the exploration risk and cost of superhot geothermal projects while promoting transparency, reproducibility, and efficiency in exploration workflows. These tools are being tested at two key sites: (1) the Nesjavellir Geothermal Area in Iceland, where the Icelandic Deep Drilling Project (IDDP) will drill its third well, and (2) Newberry Volcano in Oregon, USA, where Mazama Energy will pilot the first superhot enhanced geothermal system (EGS). A major outcome is the creation of a modular, open-source Python framework for play fairway analysis (PFA) in 2D and 3D, called geoPFA. The PFA workflow has been expanded to produce pseudo conceptual models, and will soon be refined to assess reservoir components through integration with the thermo-hydraulic-mechanical-chemical (THMC) simulator TReactMech, to enable iterative coupling between PFA and THMC models, improving characterization of superhot systems. All three of the Icelandic Deep Drilling Project's production scenarios were analyzed via this framework: (1) a superhot deep injection well paired with conventional production wells at Nesjavellir, (2) a superhot deep production well at Nesjavellir, and (3) superhot enhanced geothermal system at Newberry Volcano. This analysis provides useful insights around conceptual modeling of these production scenarios, helping to inform decisions around which scenario is best suited for which types of environments.

15 GEOTHERMAL ENERGY↗

3D Play Fairway Analysis for Examining of Superhot Drilling Production Scenarios: Preprint

The DEEPEN (DE-risking Exploration for geothermal Plays in magmatic ENvironments) project was a multi-laboratory, international effort to reduce uncertainty and improve resource characterization in superhot geothermal systems. Building on this foundation, this work advances open-source tools designed to lower the exploration risk and cost of superhot geothermal projects while promoting transparency, reproducibility, and efficiency in exploration workflows. These tools are being tested at two key sites: (1) the Nesjavellir Geothermal Area in Iceland, where the Icelandic Deep Drilling Project (IDDP) will drill its third well, and (2) Newberry Volcano in Oregon, USA, where Mazama Energy will pilot the first superhot enhanced geothermal system (EGS). A major outcome is the creation of a modular, open-source Python framework for play fairway analysis (PFA) in 2D and 3D, called geoPFA. The PFA workflow has been expanded to produce pseudo conceptual models, and will soon be refined to assess reservoir components through integration with the thermo-hydraulic-mechanical-chemical (THMC) simulator TReactMech, to enable iterative coupling between PFA and THMC models, improving characterization of superhot systems. All three of the Icelandic Deep Drilling Project's production scenarios were analyzed via this framework: (1) a superhot deep injection well paired with conventional production wells at Nesjavellir, (2) a superhot deep production well at Nesjavellir, and (3) superhot enhanced geothermal system at Newberry Volcano. This analysis provides useful insights around conceptual modeling of these production scenarios, helping to inform decisions around which scenario is best suited for which types of environments.

15 GEOTHERMAL ENERGY↗

Mixed-Mechanism Stimulation Enabled Enhanced Geothermal Systems (CRADA FP00007509 Final Report)

In this project, we aimed to develop a robust, novel EGS design that would enable broad deployment of geothermal energy at costs competitive with other sources of renewable energy. The technical objectives included developing reservoir models for synthetic geothermal systems that meet target reservoir performance characteristics, performing a quantitative assessment of selection criteria for candidate geothermal sites, perform proppant studies under relevant geothermal conditions, and complete an induced seismicity risk analysis for potential geothermal development sites. The project team made significant progress towards these objectives. Specifically, we developed a prioritization to rank candidate sites for suitability of our technology based on 10 separate technical, operational, logistic, regulatory, and commercial criteria. The team performed laboratory testing at Lawrence Berkeley National Laboratory to characterize the functionality of several different types of proppant materials at temperatures of up to 200 C for durations of up to 9 weeks. We also created an Induced Seismicity Mitigation Plan for the top two sites selected for our future field demonstrations.

58 GEOSCIENCES↗

Basin & Range Investigation for Developing Geothermal Energy

Hidden geothermal systems represent a potentially prolific energy resource that could support critical U.S. public and government energy priorities. Basin and Range Investigations for Developing Geothermal Energy (BRIDGE) addressed some the challenges associated with hidden system exploration by prioritizing cost-effective exploration early on through strategic workflow and informed decision-making that mitigates early risk and shifts resources to later exploration stages (e.g., drilling). Sandia National Laboratories partnered with U.S. Navy Geothermal Office, Geologic Geothermal Group, and independent consultants, with additional collaboration with U.S. Geological Survey and private industry. The primary tool of the BRIDGE project was to deploy a regional-scale airborne electromagnetic method to investigate the shallow resistivity structure in areas with high prospectivity. This was followed up at several prospects by a multidisciplinary exploration approach, including additional geologic, geophysical and geochemical studies. A central tenet to the BRIDGE methodology is that zones of low resistivity frequently occur over geothermal systems in the Basin and Range, and when paired with other data constraints, imaging these zones can enable discovery of these systems. In addition to exploring greenfield areas (i.e., Grover Point), the BRIDGE project also flew HTEM resistivity surveys over known geothermal systems including those with established power plants (Don A. Campbell and Salt Wells) and prospects that are known to the literature but remain undeveloped, at least in part, due to a lack of understanding on the location of their producible reservoirs. BRIDGE produced a comprehensive set of data from prospects identified in the Nevada Play Fairway Analysis along with conceptual models for top ranking prospects, wherein all of the observations are used to inform an interpreted model of the system. These models present a range of possible system parameters such as temperature and size, and they are further informed by system analogues in the Basin and Range province and elsewhere. The results of this work leave space for further exploration that may now occur at prospects ‘down the list’ rather than distribution exploration resources evenly across all prospects.

15 GEOTHERMAL ENERGY↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗

RePED 250: A Revolutionary, High Drilling Rate, High-T Geothermal Drilling System and Companion Power Electronics

Geothermal drilling in the United States is drastically slower and more costly than Oil and Gas (O&G) drilling, primarily due to the additional challenges in geothermal wells: hard rock types and high temperatures. The Repetitive Pulsed Electric Drill (250°C) (RePED-250), developed by Tetra Corporation has the potential to change this with a novel electro-crushing technology. RePED-250 releases pulses of electricity through the rock, which causes it to break in tension, instead of compression like conventional rotary drilling. The tensile strength of hard rocks like granite is only ~5% of their compressive strength, requiring less energy, time, and wear on the bit compared to conventional drilling. The RePED drill bit has no moving parts, uses drilling mud to remove rock fragments, and uses standard drill pipe, enabling a direct transition from conventional drilling systems. The objective of this project is to move RePED technology towards commercial readiness for high-temperature geothermal applications. This involves: 1) Creating high-temperature, high power electronic components for the RePED drill capable of operating at the high temperatures of a geothermal well. The target is a 250°C ambient environment. Specifically, capacitors, high voltage switches, and a downhole generator capable of generating the necessary power. 2) Demonstrating RePED’s effectiveness drilling through hard rock (granite) and examining its pathway to commercialization and effect on the US geothermal market. Work on this project has led to significant improvement over the state-of-the-art for all the examined electronics, through design, modeling, and testing of these novel components, though some additional development is still needed to deploy these high-temperature parts in a geothermal well. Besides their use in RePED-250, each component has applications in other industries where the stability of electronics at high-temperature is needed. To address the second barrier to commercialization, a 9” hole was drilled through a sample block of granite, demonstrating the tool’s effectiveness in hard rock. The team investigated RePED-250’s effect on well cost and the geothermal industry, through various techno-economic models described in the report.

15 GEOTHERMAL ENERGY↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

RePED 250: A Revolutionary, High Drilling Rate, High-T Geothermal Drilling System and Companion Power Electronics (Final Report)

Geothermal drilling in the United States is drastically slower and more costly than Oil and Gas drilling, primarily due to the additional challenges in geothermal wells: hard rock types and high temperatures. The Repetitive Pulsed Electric Drill (250 degrees C) (RePED-250), developed by Tetra Corporation has the potential to change this with a novel electro-crushing technology. RePED-250 releases pulses of electricity through the rock, which causes it to break in tension, instead of compression like conventional rotary drilling. The tensile strength of hard rocks like granite is only ~5% of their compressive strength, requiring less energy, time, and wear on the bit than conventional drilling. The RePED drill bit has no moving parts, uses drilling mud to remove rock fragments, and standard drill pipe, enabling a direct transition from conventional drilling systems. The objective of this project is to move RePED technology towards commercial readiness for high-temperature geothermal applications. This involves: 1) Creating high-temperature, high power electronic components for the RePED drill capable of operating at the high temperatures of a geothermal well. The target is a 250 degrees C ambient environment. Specifically, capacitors, high voltage switches, and a downhole generator capable of generating the necessary power. 2) Demonstrating RePED's effectiveness drilling through hard rock (granite) and examining its pathway to commercialization and effect on the US geothermal market. Work on this project has led to significant improvement over the state-of-the-art for all the examined electronics, through design, modeling, and testing of these novel components, though some additional development is still needed to deploy these high-temperature parts in a geothermal well. Besides their use in RePED-250, each component has applications in other industries where the stability of electronics at high-temperature is needed. To address the second barrier to commercialization, a 9" hole was drilled through a sample block of granite, demonstrating the tool's effectiveness in hard rock. The team investigated RePED-250's effect on well cost, and the geothermal industry, through various models described in the report.

15 GEOTHERMAL ENERGY↗

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

Assessing geothermal/solar hybridization – Integrating a solar thermal topping cycle into a geothermal bottoming cycle with energy storage

Geothermal and concentrating solar power (CSP) technologies typically use heat at different temperatures in their commercial deployments. This enables a technically viable hybridization of a solar topping cycle and a geothermal bottoming cycle at locations where both resources are available. In this article, an underperforming geothermal power system based at Burley, Idaho is used as a baseline to investigate the technical and economic potential of such a hybrid cycle. A direct thermal energy storage (TES) system is also integrated to overcome the intermittency of the solar resource. Design and off-design behavior of key components are modelled to simulate the annual performance of the hybrid system on an hourly basis. The sizing of the solar field and thermal storage is investigated and is seen to significantly impact the annual electricity generation and efficiency. Various cost scenarios for the solar field and thermal energy storage are investigated. An economic metric - levelized cost of electricity (LCOE) - is used to optimize the solar field sizing and TES capacity. The hybrid plant converts the additional solar heat input into additional work with an efficiency of 32.9%. Retrofitting a geothermal plant with solar and eight hours of energy storage can achieve an LCOE of 0.136 $/kWhe in current cost scenarios and 0.081 $/kWhe in a future cost reduction scenario. Although the hybrid system cannot directly compete with current PV systems without batteries, it has an LCOE 32% lower than that of a PV-battery system. This paper provides insights into the research and development of the future grid with a high renewable energy penetration and encourages further study of energy hybridization for improved efficiencies and economics.

15 GEOTHERMAL ENERGY↗

Enhanced Geothermal Shot Analysis for the Geothermal Technologies Office

In 2021, the U.S. Department of Energy (DOE) began the Energy Earthshots initiatives to accelerate breakthroughs of reliable clean energy solutions within the next 10 years. In 2022, the National Renewable Energy Laboratory (NREL) was asked by the DOE Geothermal Technologies Office (GTO) to provide analysis for developing Energy Earthshot targets for Enhanced Geothermal Systems (EGS), human-made underground reservoirs that extract thermal energy from the earth for electricity generation and/or heating applications. The Enhanced Geothermal Shot analysis is based on the technology assumptions in the 2019 GTO report GeoVision: Harnessing the Heat Beneath Our Feet. For Earthshot, we updated some of the technology cost and performance assumptions based on recent technology advances and updated the EGS resource potential to include more detailed analysis. We used the updated EGS supply cost curves to forecast the amount of geothermal electricity generation that could be deployed in the US by 2050 using a capacity expansion model. The results were used to develop a cost target for EGS. On September 8th, 2022, the Enhanced Geothermal Shot was announced. Its target - reduce the cost of EGS by 90%, to $45 per megawatt hour by 2035. This paper summarizes the cost and resource assumptions used in the Enhanced Geothermal Shot. It describes the assumptions used in the Regional Energy Deployment System (ReEDS) capacity expansion model to forecast geothermal deployment and discusses the results.

15 GEOTHERMAL ENERGY↗

Enhanced Geothermal Shot Analysis for the Geothermal Technologies Office: Preprint

In 2021, the U.S. Department of Energy (DOE) began the Energy Earthshots initiatives to accelerate breakthroughs of reliable clean energy solutions within the next 10 years. In 2022, the National Renewable Energy Laboratory (NREL) was asked by the DOE Geothermal Technologies Office (GTO) to provide analysis for developing Energy Earthshot targets for Enhanced Geothermal Systems (EGS), human-made underground reservoirs that extract thermal energy from the earth for electricity generation and/or heating applications. The Enhanced Geothermal Shot analysis is based on the technology assumptions in the 2019 GTO report GeoVision: Harnessing the Heat Beneath Our Feet. For Earthshot, we updated some of the technology cost and performance assumptions based on recent technology advances and updated the EGS resource potential to include more detailed analysis. We used the updated EGS supply cost curves to forecast the amount of geothermal electricity generation that could be deployed in the US by 2050 using a capacity expansion model. The results were used to develop a cost target for EGS. On September 8th, 2022, the Enhanced Geothermal Shot was announced. Its target - reduce the cost of EGS by 90%, to $45 per megawatt hour by 2035. This paper summarizes the cost and resource assumptions used in the Enhanced Geothermal Shot. It describes the assumptions used in the Regional Energy Deployment System (ReEDS) capacity expansion model to forecast geothermal deployment and discusses the results.

analysis↗

Integrated Resource and System Plannning Based on Energy Costs and Emission Analysis for a Sustainable Future

Efficient integration of renewable energy sources (RES) - such as wind, solar, geothermal, tidal, and wave - into the electric power grids can help improve energy security and contribute toward a sustainable energy future. To date, however, electric power grids are critically dependent on conventional sources, such as fossil fuels. Given the increasing penetration of RES and dynamic loads, there is a need to thoroughly reanalyze the performance of power grids in terms of cost, efficiency, and energy security. This paper presents a comprehensive analysis in terms of energy costs and emissions estimates of dynamic power grids incorporating various power-generating sources.

distributed energy resources↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Renewable electricity capacity planning with uncertainty at multiple scales

Abstract We formulate and compare optimization models of investment in renewable generation using a suite of social planning models that compute optimal generation capacity investments for a hydro-dominated electricity system where inflow uncertainty results in a risk of energy shortage. The models optimize the expected cost of capacity expansion and operation allowing for investments in hydro, geothermal, solar, wind, and thermal plant, as well as battery storage for smoothing load profiles. A novel feature is the integration of uncertain seasonal hydroelectric energy supply and short-term variability in renewable supply in a two-stage stochastic programming framework. The models are applied to data from the New Zealand electricity system and used to estimate the costs of moving to a 100% renewable electricity system by 2035. We also explore the outcomes obtained when applying different forms of CO 2 constraint that limit respectively non-renewable capacity, non-renewable generation, and CO 2 emissions on average, almost surely, or in a chance-constrained setting, and show how our models can be used to investigate the merits of a proposed pumped-hydro scheme in New Zealand’s South Island.

Ferris, Michael C.↗

Study of Foam Fracturing for Enhanced Geothermal Systems Using Model Material

Foam fracturing is considered a potential approach to address water concerns with hydraulic fracturing in the development of enhanced geothermal systems (EGS). In many EGS sites, water required for hydraulic fracturing is either unavailable, extremely costly or environmentally unsustainable. This paper presents work performed in the first year of a project sponsored by the U.S. DOE GTO Waterless Stimulation Initiative that investigates foam fracturing as an alternative approach to hydraulic fracturing. One element of this work explores foam formulations that are suitable for EGS conditions. A separate paper submitted to this workshop covers the relevant work on foam characterization (Thakore et al., 2020).This paper describes the development of an experimental setup for studying the applicability of foam fluids for hydraulic fracturing along with enhanced fracture efficiency through cyclic pressurization. The system is equipped with pulse rate automation, dual pulse valves for enhanced pulsation amplitudes, and other functions. It can perform static injection at a given pressurization rate, and pulsed injection at specified pulse size and rate. Both single-phase and foamed fluids can be used. Initial experimental results of foam fracturing using cement as a model material are reported. The observations from the experimental work will be presented and discussed.

Wang, Hong↗