Terawatt attosecond x-ray source driven by a plasma accelerator

Plasma accelerators can generate ultra-high-brightness electron beams that open the door to light sources with a smaller physical footprint and properties un-achievable with conventional accelerator technology. In this paper, we show that electron beams from Plasma WakeField Accelerators can generate few-cycle coherent tunable soft x-ray pulses with TW peak power and a duration of tens of attoseconds, an order of magnitude more powerful, shorter, and with better stability than state-of-the-art X-ray Free Electron Lasers (XFELs). Such a light source would significantly enhance the ability to experimentally investigate electron dynamics on ultrafast timescales, having a broad-ranging impact across multiple scientific fields. Rather than starting from noise as in typical XFELs, the x-ray emission in this approach is driven by coherent radiation from a pre-bunched, high peak current electron beam of attosecond duration. This relaxes the restrictive tolerances that have hindered progress toward utilizing plasma accelerators as coherent x-ray drivers thus far, presenting a new paradigm for advanced accelerator light source applications.

43 PARTICLE ACCELERATORS↗

Magnetized stimulated scattering in pulsar winds

The effects of stimulated scattering on a collimated high brightness temperature beam of photons traversing a relativistically streaming magnetized plasma are studied. Under the assumption that the center of the photon beam is parallel to the bulk motion, we calculate the scattering rate as a function of the angular spread of the beam and the Lorentz factor gamma. Magnetization changes the photon recoil, without which stimulated scattering has no effect. It also introduces a strong dependence on frequency and polarization: if the photon frequency matches the electron cyclotron frequency, the scattering rate of photons polarized perpendicular to the magnetic field can be substantially enhanced relative to Thomson, and if the photon frequency is much less than the cyclotron frequency, the scattering is suppressed. Applying these calculations to pulsars, we find that stimulated scattering of the radio beam in the magnetized wind believed to exist outside the light cylinder can substantially alter the spectrum and polarization state of the radio signal. We suggest that the scattering rate is so high in some pulsars that the ability of the radio signal to penetrate the pulsar magnetosphere requires modification of either the conventional model of the magnetosphere or assumptions about the effects of stimulated scattering upon a beam.

Sincell, Mark W.↗

High-brightness electron injectors for high-duty cycle X-ray free electron lasers

The successful development in the last two decades of X-ray free electron lasers (FELs) with their revolutionary brightness performance has been tightly dependent on the parallel development of electron guns and injectors capable of providing the high-brightness electron beams required by FELs lasing at these short wavelengths. The ultimate brightness delivered by a linear accelerator (linac) is already set at its injector and the remaining part of the accelerator can be only designed to preserve the injector performance. The technology to be used for the accelerator part of an X-Ray FEL strongly depends on the duty-cycle at which the FEL operates. Normal-conducting, room-temperature, copper-based radio frequency (RF) technology is typically used for low duty-cycles of up to approximately 10 −3 . For higher duty-cycles and up to continuous wave (CW) operation, the linac must rely on superconductive RF technology because, with the higher duty-cycle, the increasingly higher power dissipated in normal conducting RF structures becomes excessive for the warm technology. The situation changes in the lower energy part of the accelerator, where injector schemes, based on direct current, normal-conducting, and superconducting RF electron guns, are demonstrating the beam quality performance required by high-duty-cycle X-ray FELs. In this paper we start with a description of the requirements for such injectors, followed by an overview of the pursued technologies and schemes, and by a discussion on the main differences in terms of beam dynamics between low and high duty-cycle injectors.

Sannibale, Fernando↗

Improved laser-plasma accelerator stability via high-bandwidth longitudinal focal position stabilization of a 100 TW-class laser system

Laser-plasma accelerators (LPAs) offer an attractive alternative to conventional accelerators for the development of compact electron sources and next-generation light sources. Due to orders-of-magnitude larger accelerating gradients, LPAs enable the acceleration of high-brightness electron beams to ultrarelativistic energies in millimeter- to centimeter-scale distances. However, LPA stability is limited by shot-to-shot fluctuations of the driving laser system. Specifically, fluctuations in the final-focus longitudinal position result in correlated instability in LPA electron beam qualities, including total beam charge, average beam energy, and energy spread. We demonstrate active stabilization of the longitudinal focal position for a 100 TW-class laser system. This repetition-rate scalable stabilization system leverages noninvasive wave front monitoring of a copropagating, unamplified kHz pulse train to guide corrective adjustments to the focal position of a 1 Hz amplified drive laser via an upstream telescope on millisecond timescales. In this demonstration, the approach limits standard deviation fluctuations of the amplified drive beam’s longitudinal focal position to ±0.22⁢ mm (representing at least a 53% reduction), achieved with a correction bandwidth that reaches the Nyquist frequency limit. Consequently, we observe marked improvements in both long-term and shot-to-shot LPA stability in terms of charge and spectrum.

Beam control↗

Startup regime of high-efficiency tapering-enhanced FEL oscillator

In this paper, we present a design of a high-efficiency high-gain free-electron laser oscillator based on the use of a strongly tapered undulator for extracting energy from high-brightness electron beams. We provide an analytical model of the setup followed by numerical simulations for lasing at the wavelength of 13.5 nm. We discuss the optimization of the system in steady state and the conditions necessary for the pass-per-pass buildup of the power from shot noise level. We propose the use of fast phase shifters as a way to accelerate the buildup. Finally, we present time-dependent simulations of the oscillator and discuss the role of spectral filtering. The optimized working point yields a total energy conversion efficiency from the electron beam to output radiation above 1% at the wavelength of 13.5 nm.

Beam dynamics↗

Building better electron sources with graphene

This report is a press release and discusses how "Graphene substrates can be reused repeatedly for photocathodes that emit high brightness electron beams in electron microscopes and accelerators."

36 MATERIALS SCIENCE↗

Improving Cathode Testing with a High-Gradient Cryogenic Normal Conducting RF Photogun

Future electron accelerator applications such as X-ray free electron lasers and colliders are dependent on significantly increasing beam brightness. With the observation that linac beam manipulation’s best preservation of max brightness is at the cathode, we are incentivized to create an environment where we can study how to achieve the highest possible photogun brightness. In order to do so, we intend to extract beams from high-brightness photocathodes with the highest achievable accelerating gradients we can manage in a klystron-powered radiofrequency (RF) photogun. We utilize here cryogenic normal conducting cavities to achieve ultra-high gradients via limitation of breakdown rates (BDR). The low temperatures should also reduce cathode emittance by reducing the mean transverse energy (MTE) of electrons near the photoemission threshold. To this end, we have designed and produced a new CrYogenic Brightness-Optimized Radiofrequency Gun (CYBORG) for use in a new beamline at UCLA. We will introduce the enabling RF and photoemission physics as a primer for the new regime of high field low temperature cathodes we intend to enter. We further report the current status of the beamline commissioning, including the cooling of the photogun to 100 K, and producing 0.5 MW of RF feed power, which corresponds to cathode accelerating fields in the range of 80–90 MV/m. We further plan iterative improvements to both to 77 K and 1 MW corresponding to our ultimate goal >120 MV/m. Our discussion will include future beamline tests and the consideration of the initial realization of an ultra-high-gradient photoinjector concept.

Lawler, Gerard Emile (ORCID:0000000160113435)↗

Demonstration of Autonomous Emittance Characterization at the Argonne Wakefield Accelerator

Transverse beam emittance plays a key role in the performance of high-brightness accelerators. Characterizing beam emittance is often carried out using a quadrupole scan, which fits beam matrix elements to experimental measurements using first-order beam dynamics. Despite its simplicity at face value, this procedure is difficult to automate due to practical limitations. Key issues that must be addressed include maintaining beam size measurement validity by keeping beams within the radius of diagnostic screens, ensuring that measurement fitting produces physically valid results, and accurately characterizing emittance uncertainty. We describe a demonstration of the Bayesian exploration technique towards solving this problem at the Argonne Wakefield Accelerator, enabling a turn-key, autonomous quadrupole scan tool that can be used to quickly measure beam emittances at various locations in accelerators with limited operator input.

Roussel, Ryan↗

Rethinking Coherent Diffraction Instruments for High Brightness Sources

Over the past two decades, exceptional progress has been made providing coherent x-ray beams at both high-brightness synchrotron sources and x-ray free electron lasers (XFEL). The availability of these coherent x-rays has led to a surge in instruments that exploit x-ray coherence for either x-ray photon correlation spectroscopy (XPCS) or coherent diffraction imaging (CDI). A key to these techniques has been to resolve, or at least nearly resolve, the speckles associated with the scattering from structural disorder. Given practical limits on detector pixel size, this requires long sample-to-detector distances. This paper presents numerical simulations of an instrument that can efMiciently provide a long sample-detector distance while maintaining the ability to rapidly set momentum transfer by inserting crystals with different order in the incident beam, thus changing in incident direction instead of moving the detector.

Fuoss, Paul H↗

Physical processes in eclipsing pulsars: Eclipse mechanisms and diagnostics

We investigate how the radio emission of a pulsar interacts with plasma derived from a stellar companion. Various physical mechanisms that can cause radio pulse eclipse are discussed, and predictions are made for the polarization properties of the emergent radio wave. We consider eclipses by a wind from the stellar companion, by a stellar magnetosphere, or by material entrained in the pulsar wind. Eclipses due to refraction require either a relatively high plasma density or a sharp edge to the plasma distribution. The conditions that must prevail for free-free absorption to be effective in eclipsing a radio beam are also outlined. Pulse smearing may be important at higher frequencies; related eclipse mechanisms include pulse spreading due to a rapidly changing electron column, and scattering by Langmuir turbulence. The high brightness temperature radio beam can generate its own plasma turbulence via a number of nonlinear parametric instabilities, such as the instability associated with stimulated Raman scattering. When the plasma turbulence is heavily damped, the radio bean can still undergo induced Compton scattering. Stimulated scattering effects such as these are very sensitive to the presence of narrow-band substructure in the pulsar radio emission. Finally, we consider the possibility that plasma derived from a stellar companion may mix with the relativistic pulsar wind and cause cyclotron absorption at low radio frequencies. Even if the cyclotron optical depth is small, fluctuations in the emergent polarization of the radio beam on the timescale of a few seconds are a very sensitive probe of the spatial structure of the magnetic field in the pulsar wind. The current observational properties of two known eclipsing pulsar systems, PSR 1957+20 and PSR 1744-24A, are used to construct tentative eclipse models. The favored model for PSR 1957+20 is cyclotron or synchrotron absorption by plasma embedded in the pulsar wind combined with pulse smearing at high frequency, and the favored model for PSR 1744-24A is backscattering off plasma turbulence generated by the stimulated Raman scattering parametric instability. Pulsar eclipses promise to provide a good diagnostic of pulsar winds and possible of the pulse emission mechanism.

Thompson, C.↗

Superconducting radio frequency photoinjectors for CW-XFEL

A dependable and consistent electron source is a crucial requirement for the achievement of high-power free electron lasers (FELs). Over the past two decades, it has been demonstrated that photoinjectors based on SRF technology (SRF guns) are suitable for continuous wave (CW) beam generation. SRF guns possess both the high accelerating field gradients of normal conducting RF photoinjectors and the low power dissipation thanks to mature SRF cavity technology, and therefore have the potential to provide the high-brightness, high-current beams required for CW-XFELs. After the demonstration of the first SRF gun in Dresden-Rossendorf, several SRF gun programs based on different approaches have achieved promising progress and even succeeded in routine operation. SRF guns are expected to play an important role in XFEL facilities in the near future. In this paper, we give an overview of design concepts, important parameters and development status of the worldwide SRF gun projects.

47 OTHER INSTRUMENTATION↗

Plasma Photocathodes

Abstract Plasma wakefield accelerators offer accelerating and focusing electric fields three to four orders of magnitude larger than state‐of‐the‐art radiofrequency cavity‐based accelerators. Plasma photocathodes can release ultracold electron populations within such plasma waves and thus open a path toward tunable production of well‐defined, compact electron beams with normalized emittance and brightness many orders of magnitude better than state‐of‐the‐art. Such beams will have far‐reaching impact for applications such as light sources, but also open up new vistas on high energy and high field physics. This paper reviews the innovation of plasma photocathodes, and reports on the experimental progress, challenges, and future prospects of the approach. Details of the proof‐of‐concept demonstration of a plasma photocathode in 90° geometry at SLAC FACET within the E‐210: Trojan Horse program are described. Using this experience, alongside theoretical and simulation‐supported advances, an outlook is given on future realizations of plasma photocathodes such as the upcoming E‐310: Trojan Horse‐II program at FACET‐II with prospects toward excellent witness beam parameter quality, tunability, and stability. Future installations of plasma photocathodes also at compact, hybrid plasma wakefield accelerators, will then boost capacities and open up novel capabilities for experiments at the forefront of interaction of high brightness electron and photon beams.

Habib, Ahmad Fahim↗

High efficiency, high-current laser-driven electron injector (CRADA Final Report)

Owing to ultra-high fields sustainable in a plasma, laser-plasma accelerator technology enables compact, high-brightness, sources of electron beams. This work investigates novel electron injection methods. Key to this research is to understand laser energy and pointing stability and to develop methods and techniques to control fluctuations. This project benefits other areas of scientific inquiry by developing a high-repetition rate, high-brightness electron source for probing materials and ultra-fast processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High efficiency, high-current laser-driven electron injector (CRADA Final Report)

Owing to ultra-high fields sustainable in a plasma, laser-plasma accelerator technology enables compact, high-brightness, sources of electron beams. This work investigates novel electron injection methods. Key to this research is to understand laser energy and pointing stability and to develop methods and techniques to control fluctuations. This project benefits other areas of scientific inquiry by developing a high-repetition rate, high-brightness electron source for probing materials and ultra-fast processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel Ultrabright and Air-Stable Photocathodes Discovered from Machine Learning and Density Functional Theory Driven Screening

The high brightness, low emittance electron beams achieved in modern X-ray free-electron lasers (XFELs) have enabled powerful X-ray imaging tools, allowing molecular systems to be imaged at picosecond time scales and sub-nanometer length scales. One of the most promising directions for increasing the brightness of XFELs is through the development of novel photocathode materials. Whereas past efforts aimed at discovering photocathode materials have typically employed trial-and-error-based iterative approaches, this work represents the first data-driven screening for high brightness photocathode materials. Through screening over 74 000 semiconducting materials, a vast photocathode dataset is generated, resulting in statistically meaningful insights into the nature of high brightness photocathode materials. This screening results in a diverse list of photocathode materials that exhibit intrinsic emittances that are up to 4x lower than currently used photocathodes. In a second effort, multiobjective screening is employed to identify the family of M 2 O (M = Na, K, Rb) that exhibits photoemission properties that are comparable to the current state-of-the-art photocathode materials, but with superior air stability. This family represents perhaps the first intrinsically bright, visible light photocathode materials that are resistant to reactions with oxygen, allowing for their transport and storage in dry air environments.

36 MATERIALS SCIENCE↗

Relations between Shot Noise, Gain Bandwidth, and Saturation of Instabilities

There are numerous instabilities present in charged particle beams that undergo exponential growth and reach saturation. In various applications, such as free-electron lasers or micro-bunching light sources, achieving saturation is desirable. Conversely, there are applications where these instabilities are utilized as linear broad-band amplifiers for signals embedded in the charged beam. In the latter scenario, the saturation of an instability induces non-linear distortions in the imprinted signal, thereby limiting the useful range of such amplifiers. Accurate evaluation of these instabilities necessitates a complete and comprehensive modeling approach that includes shot noise within the beam. Unfortunately, such modeling is not always feasible or practical. In this paper, we introduce a methodology utilizing the frequency and bandwidth of the instability as key parameters. Through this, we derive an estimation for the range of linear instability growth. Our derivation is conducted in a model-independent manner, making it applicable to a broad spectrum of instabilities. To validate our approach, we employ established and thoroughly benchmarked simulations with a free electron laser (FEL) code as well as self-consistent 3-dimensional simulation of plasma-cascade instability using code SPACE.

43 PARTICLE ACCELERATORS↗

APS Science 2020 (Vol. 2)

The U.S. Department of Energy's Advanced Photn Source (APS) is one of the world’s most productive x-ray light source facilities. Each year, the APS provides high-brightness x-ray beams to a diverse community of more than 5,000 researchers in materials science, chemistry, condensed matter physics, the life and environmental sciences, and applied research. Researchers using the APS produce over 2,000 publications each year detailing impactful discoveries, and solve more vital biological protein structures than users of any other x-ray light source research facility. APS x-rays are ideally suited for explorations of materials and biological structures; elemental distribution; chemical, magnetic, electronic states; and a wide range of technologically important engineering systems from batteries to fuel injector sprays, all of which are the foundations of our nation’s economic, technological, and physical well-being. The APS occupies an 80-acre site on the Argonne campus, about 25 miles from downtown Chicago, Illinois. It shares a site with the Center for Nanoscale Materials and the Advanced Protein Characterization Facility.

01 COAL, LIGNITE, AND PEAT↗

APS Science 2020 (Vol. 1)

The U.S. Department of Energy's Advanced Photon Source (APS) is one of the world’s most productive x-ray light source facilities. Each year, the APS provides high-brightness x-ray beams to a diverse community of more than 5,000 researchers in materials science, chemistry, condensed matter physics, the life and environmental sciences, and applied research. Researchers using the APS produce over 2,000 publications each year detailing impactful discoveries, and solve more vital biological protein structures than users of any other x-ray light source research facility. APS x-rays are ideally suited for explorations of materials and biological structures; elemental distribution; chemical, magnetic, electronic states; and a wide range of technologically important engineering systems from batteries to fuel injector sprays, all of which are the foundations of our nation’s economic, technological, and physical well-being. The APS occupies an 80-acre site on the Argonne campus, about 25 miles from downtown Chicago, Illinois. It shares a site with the Center for Nanoscale Materials and the Advanced Protein Characterization Facility.

25 ENERGY STORAGE↗