Search NASA⌕ Search

SEARCH · Search NASA

Results for “hot”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Interaction of Hot and Cold Gas in the Disk and Halo of Galaxies

Most of the thermal energy in the Galaxy and perhaps most of the baryons in the Universe are found in hot (log T approximately 5.5 - 7) gas. Hot gas is detected in the local interstellar medium, in supernova remnants (SNR), the Galactic halo, galaxy clusters and the intergalactic medium (IGM). In our own Galaxy, hot gas exists in large superbubbles up to several hundred pc in diameter that locally dominate the interstellar medium (ISM) and determine its thermal and dynamic evolution. While X-ray observations using ROSAT, Chandra and XMM have allowed us to make dramatic progress in mapping out the morphology of the hot gas and in understanding some of its spectral characteristics, there remain fundamental questions that are unanswered. Chief among these questions is the way that hot gas interacts with cooler phase gas and the effects these interactions have on hot gas energetics. The theoretical investigations we proposed in this grant aim to explore these interactions and to develop observational diagnostics that will allow us to gain much improved information on the evolution of hot gas in the disk and halo of galaxies. The first of the series of investigations that we proposed was a thorough exploration of turbulent mixing layers and cloud evaporation. We proposed to employ a multi-dimensional hydrodynamical code that includes non-equilibrium ionization (NEI), radiative cooling and thermal conduction. These models are to be applied to high velocity clouds in our galactic halo that are seen to have O VI by FUSE (Sembach et ai. 2000) and other clouds for which sufficient constraining observations exist.

Slavin, Jonathan↗

A measurement concept for hot-spot BRDFs from space

Several concepts for canopy hot-spot measurements from space have been investigated. The most promising involves active illumination and bistatic detection that would allow hot-spot angular distribution (BRDF) measurements from space in a search-light mode. The concept includes a pointable illumination source, such as a laser operating at an atmospheric window wavelength, coupled with a number of high spatial-resolution detectors that are clustered around the illumination source in space, receiving photons nearly coaxial with the reto-reflection direction. Microwave control and command among the satellite cluster would allow orienting the direction of the laser beam as well as the focusing detectors simultaneously so that the coupled system can function like a search light with almost unlimited pointing capabilities. The concept is called the Hot-Spot Search-Light (HSSL) satellite. A nominal satellite altitude of 600 km will allow hot-spot BRDF measurements out to about 18 degrees phase angle. The distributed are taking radiometric measurements of the intensity wings of the hot-spot angular distribution without the need for complex imaging detectors. The system can be operated at night for increased signal-to-noise ratio. This way the hot-spot angular signatures can be quantified and parameterized in sufficient detail to extract the biophysical information content of plant architectures.

Reflectivity↗

Extreme Environment Hot Fire Durability of Post-Processed Additively Manufactured GRCop-Alloy Combustion Chambers in LOX/Hydrogen and LOX/Methane

Extreme environment survivability of metal additive manufactured (AM) GRCop-alloy thrust chambers has been demonstrated in different bi-propellants at near stoichiometric and even oxygen rich combustion. GRCop-alloy chambers tested at NASA Marshall Space Flight Center (MSFC) have accumulated over 26,000 seconds of hot fire duration and over 500 starts. These chambers are produced using an AM process called laser powder bed fusion (L-PBF). A major feature of this process is high wall surface roughness which can be customized in post processing to leverage various performance advantages. Post-processing can include heat treatment, final machining, polishing, and welding and is key to hardware survivability in extreme environments. Surface finish enhancement techniques were applied to the hot wall and coolant channels to reduce the overall total heat load to the chamber walls. Performance optimization of various thrust class TCA’s is a strategic technology goal of NASA MSFC. Three different chamber geometries using cryogenic methane and de-ionized water as coolants were hot fire tested to obtain their life cycle, pressure drop, and heat load performances. Several 1.2K lbf LOX/H2 chambers, 1K lbf LOX/CH4 chambers, and 7K lbf LOX/CH4 chambers were tested. All post-processed configurations performed remarkably well when subjected to extreme hot fire test conditions. Streaking and blanching due to localized oxygen rich conditions were observed on some test articles in their as-built surface finish state. However, this is actually a function of the injector mixing and only serves to further establish the durability of L-PBF GRCop-alloy thrust chambers. Several different polishing techniques were applied to the hot wall and integrated coolant channels prior to hot fire testing and their performances assessed. Overall, AM produced GRCop chambers are extremely reliable, durable, and customizable to the desired performance metrics.

grcop↗

Hot-film static-pressure probe for surveying flow fields

A static pressure probe employing hot-film sensors has been developed for the rapid measurement of the static pressure fields surrounding analytic shapes in hypersonic flows. The hot-film probe is a modification of the standard static pressure probe, consisting of a front hot-film sensor operated as a resistance thermometer, a rear sensor operated at an overheat ratio of 1.5 to 1.8 and a small sonic orifice installed inside the tubing of a conventional device. The probe has been calibrated in helium and air over a range of temperatures and pressures in a bell jar apparatus, with a repeatability of the data to within + or - 0.015 mm Hg. Comparative tests of the hot-film and conventional static pressure probes in a hypersonic helium wind tunnel at Mach 20 and various Reynolds numbers have indicated the settling time of the hot-film probe to be on the order of milliseconds, as compared with 30 sec for the conventional probe. The pressures measured by the two probes were found to be within 10% of each other. Although the hot-film probe makes flow-field static pressure surveys more practical in blowdown hypersonic wind tunnels, viscous and flow angle effects still must be assessed under the conditions of use.

Ashby, G. C., Jr.↗

Semiempirical hot atom theory. I - Initialization and application

A semiempirical approach to the modeling of the kinetics of reaction systems containing both hot and nonhot atoms is proposed. The approach is based on the probabilistic kinetic theory of hot-atom reactions formulated by Wolfgang (1963), with transmission probabilities estimated for a rectangular potential barrier for hot-atom and nonhot-atom reactions. A computational scheme for determining product concentrations following hot and nonhot reactions in a system containing photolytically produced hot atoms is then applied to the DBr + CH4 and HBr + CD4 hot hydrogen atom systems studied by Martin and Willard (1964), and good agreement is obtained between theoretical and experimental results.

Aronowitz, S.↗

Uncertainties in hot-wire measurements of compressible turbulent flows implied by comparisons with laser-induced fluorescence

A hot-wire anemometer and a new nonintrusive laser-induced fluorescence (LIF) technique are used to survey a Mach 2 turbulent boundary layer. The hot-wire anemometer's ability to accurately measure mass flux, temperature, and density fluctuations in a compressible flow is examined by comparing its results with those obtained using LIF. Several methods of hot-wire calibration are used, and the uncertainties in their measurements of various fluctuating flow parameters are determined. The results show that although a hot-wire operated at high overheat can measure mass flux fluctuations, temperature and density fluctuations are not determined accurately from such measurements. However, a hot-wire operated at multiple overheats can be used to measure static and total temperature fluctuations. The presence of pressure fluctuations and their correlation with density can prevent the use of hot-wire data to determine density fluctuations.

Mckenzie, R. L.↗

Concentrator hot-spot testing, phase 1

Results of a study to determine the hot-spot susceptibility of concentrator cells, to provide a hot-spot qualification test for concentrator modules, and to provide guidelines for reducing hot-spot susceptibility are presented. Hot-spot heating occurs in a photovoltaic module when the short-circuit current of a cell is lower than the string operating current forcing the cell into reverse bias with a concurrent power dissipation. Although the basis for the concentrator module hot-spot qualification test is the test developed for flat-plate modules, issues, such as providing cell illumination, introduce additional complexities into the testing procedure. The same general guidelines apply for protecting concentrator modules from hot-spot stressing as apply to flat-plate modules. Therefore, recommendations are made on the number of bypass diodes required per given number of series cells per module or source circuit. In addition, a new method for determining the cell temperature in the laboratory or in the field is discussed.

Gonzalez, C. C.↗

Hot-spot qualification testing of concentrator modules

Results of a study to determine the hot-spot susceptibility of concentrator cells, to provide a hot-spot qualification test for concentrator modules, and to provide guidelines for reducing hot-spot susceptibility are presented. Hot-spot heating occurs in a photovoltaic module when the short-circuit current of a cell is lower than the string operating current, forcing the cell into reverse bias with a concurrent power dissipation. Although the basis for the concentrator-module hot-spot qualification test is the test developed for flat-plate modules, issues such as providing cell illumination introduce additional complexities into the testing procedure. The results indicate that the same general guidelines apply to protecting concentrator modules from hot-spot stressing as apply to flat-plate modules, and recommendations are made on the number of bypass diodes required per given number of series cells per module or source circuit. A method for determining the cell temperature in the laboratory or in the field is discussed.

Gonzalez, C. C.↗

Hot-wire accuracy in supersonic turbulence from comparisons with laser-induced fluorescence

A hot-wire anemometer and a new, nonintrusive, laser-induced fluorescence (LIF) technique are used to survey a turbulent boundary layer in a supersonic channel flow at Mach no. 2.06. The purpose is to test the accuracy of using the hot wire to measure the fluctuation amplitudes of static temperature and density in a compressible turbulent flow by comparing the results with independent and direct LIF measurements. Several methods of hot-wire calibration and analysis are applied. With each method, the hot-wire response can be related primarily to fluctuations of mass flux and total temperature, from which fluctuations of static temperature and density are calculated. However, these calculations are shown to be valid only if the fluctuations in static pressure are negligible. The acquisition and the analysis of the hot-wire data are often simplified further by neglecting the effects of fluctuations in total temperature. Comparisons of the fluctuation amplitudes of temperature and density obtained by hot-wire and LIF measurements demonstrate that such assumptions might not always be warranted, even in apparently simple flows.

Logan, Pamela↗

Hot gas ingestion characteristics and flow visualization of a vectored thrust STOVL concept

A 9.2 percent scale short takeoff and vertical landing (STOVL) hot gas ingestion model was designed and built by McDonnell Douglas Corporation (MCAIR) and tested in the NASA Lewis Research Center 9- by 15-Foot Low Speed Wind Tunnel (LSWT). Hot gas ingestion, the entrainment of heated engine exhaust into the inlet flow field, is a key development issue for advanced short takeoff and vertical landing aircraft. The Phase 1 test program, conducted by NASA Lewis and McDonnell Douglas Corporation, evaluated the hot ingestion phenomena and control techniques and Phase 2 test program which was conducted by NASA Lewis are both reported. The Phase 2 program was conducted at exhaust nozzles temperatures up to 1460 R and utilized a sheet laser system for flow visualization of the model flow field in and out of ground effects. Hot gas ingestion levels were measured for the several forward nozzle splay configurations and with flow control/lift improvement devices which reduced the hot gas ingestion. The model support system had four degrees of freedom, heated high pressure air for nozzle flow, and a suction system exhaust for inlet flow. The headwind (freestream) velocity for Phase 1 was varied from 8 to 90 kn, with primary data taken in the 8 to 23 kn headwind velocity range. Phase 2 headwind velocity varied from 10 to 23 kn. Results of both Phase 1 and 2 are presented. A description of the model, facility, a new model support system, and a sheet laser illumination system are also provided. Results are presented over a range of main landing gear height (model height) above the ground plane at a 10 kn headwind velocity. The results contain the compressor face pressure and temperature distortions, total pressure recovery, compressor face temperature rise, and the environmental effects of the hot gas. The environmental effects include the ground plane temperature and pressure distributions, model airframe heating, and the location of the ground flow separation. Results from the sheet laser flow visualization test are also shown.

Johns, Albert L.↗

Unsteady analysis of hot streak migration in a turbine stage

Two- and three-dimensional Navier-Stokes analyses are used to predict unsteady viscous rotor-stator interacting flow in the presence of a combustor hot streak. Predicted results are presented for a two-dimensional three-stator/four-rotor, a two-dimensional one-stator/one-rotor, and a three-dimensional one-stator/one-rotor simulation of hot streak migration through a turbine stage. Comparison of these results with experimental data demonstrates the capability of the three-dimensional procedure to capture most of the flow physics associated with hot streak migration including the effects of combustor hot streaks on turbine rotor surface temperatures. It is noted that blade count ratio has little effect on predicted time-averaged surface pressure and temperature distributions, but a substantial effect on the unsteady flow characteristics. It is shown that high-temperature hot streak fluid accumulates on the pressure surface of the rotor blades, resulting in a high time-averaged surface temperature 'hot spots'.

Dorney, Daniel J.↗

Hot gas ingestion test results of a two-poster vectored thrust concept with flow visualization in the NASA Lewis 9- by 15-foot low speed wind tunnel

A 9.2 percent scale STOVL hot gas ingestion model was tested in the NASA Lewis 9 x 15-foot Low-Speed Wind Tunnel. Flow visualization from the Phase 1 test program, which evaluated the hot ingestion phenomena and control techniques, is covered. The Phase 2 test program evaluated the hot gas ingestion phenomena at higher temperatures and used a laser sheet to investigate the flow field. Hot gas ingestion levels were measured for the several forward nozzle splay configurations and with flow control/life improvement devices (LIDs) which reduced the hot gas ingestion. The test was conducted at full scale nozzle pressure ratios and inlet Mach numbers. Results are presented over a range of nozzle pressure ratios at a 10 kn headwind velocity. The Phase 2 program was conducted at exhaust nozzle temperatures up to 1460 R and utilized a sheet laser system for flow visualization of the model flow field in and out of ground effects. The results reported are for nozzle exhaust temperatures up to 1160 R and contain the compressor face pressure and temperature distortions, the total pressure recovery, the inlet temperature rise, and the environmental effects of the hot gas. The environmental effects include the ground plane contours, the model airframe heating, and the location of the ground flow separation.

Johns, Albert L.↗

Hot proton anisotropies and cool proton temperatures in the outer magnetosphere

The hot protons of the outer magnetosphere typically exhibit a temperature anistropy such that T(sub perp)/T(sub parallel) greater than 1, where perpendicular and parallel symbols denote directions relative to the background magnetic field. If this anisotrpy is sufficiently large, the electomagneitc proton cyclotron anistropy instability may be excited. This instability is studied using linear Vlasov theory and one-dimensional hybrid simulations for a homogeneous plasma model representative of conditions in the outer magnetosphere with a hot anisotropic proton component (denoted by subscript h) and a cool, initially isotropic proton component (subscript c). Linear theory yields an instability threshold condition on the hot proton temperature anistropy where as the simulations imply an upper bound on T(sub perp h)/T(sub parallel h); both the threshold and the upper bound have similar scaling with the maximum growth rate gamma (sub m), the parallel beta of the hot component, beta(sub parallel h), and the relative density of the hot component n(sub h)/n(sub e). An anlysis of plasma observations from the Los Alamos magnetospheric plasma analyzer (MPA) in geosynchronous orbits finds that the maximum value of the hot proton temperature anisotropy approximately satisfies the predicted scaling with beta(sub parallel h) and nu(sub h)/n(sub e) and yields the proportionality factor that quantifies this upper bound. The simulations are also used to examine the heating of the cool proton cyclotron instability. The simulations yield a scaling for the dimensionless late-time cool proton average temperature T(sub c)/T(sub parallel h) as (n(sub h)/n(sub e))/beta(sub parallel h exp 0.5). Analysis of MPA data shows that the observed values of T(sub c)/T(sub parallel h) have similar scaling and again yield the proportionality factor which quantifies this relationship.

Gary, S. Peter↗

Characterization of a hot-film probe for hypersonic flow

The critical issues concerning the application of constant-temperature hot-film anemometry to hypersonic flow are reviewed and extended. Mass-flux static calibrations were conducted in a Mach 10 helium flow, while mass-flux and total-temperature static calibrations were made in a Mach 6 air flow. In addition, comparative hot-film/hot-wire turbulence measurements were made in a Mach 11 helium boundary layer to provide insight into the dynamic response of the hot film. The measurements indicate that substrate conduction 'losses' dominate the static response of the hot-film probe, thus resulting in poor sensitivity to mass-flux and total temperature. Furthermore, it has been found that it is not possible to isolate mass-flux fluctuations at high overheat ratios for the current hot-film design. Thus, the sapphire-substrate hot-film anemometer is a robust, high-bandwidth instrument limited to qualitative transition and turbulence measurements. Finally, the extension of this technique to providing quantitative information is dependent upon the development of lower thermal-conductivity substrate materials.

Sheplak, M.↗

Hot spots and active longitudes: Organization of solar activity as a probe of the interior

In order to investigate how solar activity is organized in longitude, major solar flares, large sunspot groups, and large scale photospheric magnetic field strengths were analyzed. The results of these analyses are reported. The following results are discussed: hot spots, initially recognized as areas of high concentration of major flares, are the preferred locations for the emergence of big sunspot groups; double hot spots appear in pairs that rotate at the same rate separated by about 180 deg in longitude, whereas, single hot spots have no such companions; the northern and southern hemispheres behave differently in organizing solar activity in longitude; the lifetime of hot spots range from one to several solar cycles; a hot spot is not always active throughout its lifetime, but goes through dormant periods; and hot spots with different rotational periods coexist in the same hemisphere during the same solar cycle.

Bai, Taeil↗

Flash Mixing on the White-Dwarf Cooling Curve: Understanding Hot Horizontal Branch Anomalies in NGC 2808

We present an ultraviolet color-magnitude diagram (CMD) spanning the hot horizontal branch (HB), blue straggler, and white dwarf populations of the globular cluster NGC 2808. These data, obtained with the Space Telescope Imaging Spectrograph (STIS), demonstrate that NGC 2808 harbors a significant population of hot subluminous HB stars, an anomaly only previously reported for the globular cluster omega Cen. Our theoretical modeling indicates that the location of these subluminous stars in the CMD, as well as the high temperature gap along the HB of NGC 2808, can be explained if these stars underwent a late helium-core flash while descending the white dwarf cooling curve. We show that the convective zone produced by such a late helium flash will penetrate into the hydrogen envelope, thereby mixing hydrogen into the hot helium-burning interior, where it is rapidly consumed. This phenomenon is analogous to the "born again" scenario for producing hydrogen-deficient stars following a late helium-shell flash. The flash mixing of the envelope greatly enhances the envelope helium and carbon abundances that, in turn, leads to a discontinuous increase in the HB effective temperatures. We argue that the hot HB gap is associated with this theoretically predicted dichotomy in the HB properties. Moreover, the changes in the emergent spectral energy distribution caused by these abundance changes are primarily responsible for explaining the hot subluminous HB stars. Although further evidence is needed to confirm that a late helium-core flash can account for the subluminous HB stars and the hot HB gap, we demonstrate that an understanding of these stars requires the use of appropriate theoretical models for their evolution, atmospheres, and spectra.

Brown, Thomas M.↗

Measurements of Aerosol, Ocean and Sky Properties at the HOT Site in the Central Pacific

Monthly cruises have been made to the HOT site (approximately 100 km north of Oahu) since October 1988. The goal of these cruises is to make hydrography, chemistry, and biology observations. Measurements are typically made at a near coastal station (Kahe) on the first day to test the equipment and to obtain coastal shallow water (approximately 1500 m) observations. The second and third days are spent at the HOT site. On the morning of the fourth day, measurements are made at the HOT site and noontime measurements are made at the Hale-Aloha station near the mooring before returning to port by early the next morning. The locations of the three stations are Kahe, HOT, and Hale-ALOHA buoy. The routine HOT measurements are available during the summer following the year of the observations. The 1998 measurements will therefore become available during the summer of 1999. The data sets can be obtained at the National Oceanographic Data Center (NODC) or from the HOT web site http://kahana.soest.hawaii.edu/hot/hot_jgofs.html.

Porter, John N.↗

Experimental Evaluation of Hot Films on Ceramic Substrates for Skin-Friction Measurement

An investigation has been performed on the use of low-thermal conductivity, ceramic substrates for hot films intended to measure skin friction. Hot films were deposited on two types of ceramic substrates. Four hot films used composite-ceramic substrates with subsurface thermocouples (TCs), and two hot films were deposited on thin Macor(R) substrates. All six sensors were tested side by side in the wall of the NASA Glenn Research Center 8-ft by 6-ft Supersonic Wind Tunnel (SWT). Data were obtained from zero flow to Mach 1.98 in air. Control measurements were made with three Preston tubes and two boundary-layer rakes. The tests were repeated at two different hot film power levels. All hot films and subsurface TCs functioned throughout the three days of testing. At zero flow, the films on the high-thermal conductivity Macor(R) substrates required approximately twice the power as those on the composite-ceramic substrates. Skin-friction results were consistent with the control measurements. Estimates of the conduction heat losses were made using the embedded TCs but were hampered by variability in coating thicknesses and TC locations.

Noffz, Gregory K.↗