Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrazine detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ion mobility spectrometry of hydrazine, monomethylhydrazine, and ammonia in air with 5-nonanone reagent gas

Hydrazine (HZ) and monomethylhydrazine (MMH) in air were monitored continuously using a hand-held ion mobility spectrometer equipped with membrane inlet, 63Ni ion source, acetone reagent gas, and ambient temperature drift tube. Response characteristics included detection limit, 6 ppb; linear range, 10-600 ppb; saturated response, >2 ppm; and stable response after 15-30 min. Ammonia interfered in hydrazines detection through a product ion with the same drift time as that for MMH and HZ. Acetone reagent gas was replaced with 5-nonanone to alter drift times of product ions and separate ammonia from MMH and HZ. Patterns in mobility spectra, ion identifications from mass spectra, and fragmentation cross-sections from collisional-induced dissociations suggest that drift times are governed by ion-cluster equilibria in the drift region of the mobility spectrometer. Practical aspects including calibration, stability, and reproducibility are reported from the use of a hand-held mobility spectrometer on the space shuttle Atlantis during mission STS-37.

Flight Experiment↗

Nanosensors for Evaluating Hazardous Environments

Personnel working in a confined environment can be exposed to hazardous gases, and certain gases can be extremely dangerous even in concentrations as low as a few parts per billion. Nanosensors can be placed in multiple locations over a large area, thus allowing for more precise and timely detection of gas leaks. ASRC Aerospace and its research partners are developing nanosensors to detect various gases, including hydrogen, ammonia, nitrogen tetroxide, and hydrazine. Initial laboratory testing demonstrated the capability to detect these gases in concentrations lower than parts per million, and current testing is evaluating sensitivity at concentration levels three orders of magnitude lower. Testing and development continue to improve the response and recovery times and to increase the sensitivity of the devices. The development team is evaluating different coatings and electrodes to determine the optimum configuration for detecting and identifying a variety of gases. The small footprint of the nanosensors allows several devices to be placed into a single substrate. Each sensor is responsive in a different way to different gases. Embedding multiple devices into a single substrate results in better reliability and less frequent calibrations. The use of different coatings for individual elements of a multichannel sensor allows different gases to be identified. The sensor system is implemented by the use of a custom multichannel signal conditioner amplifier built on a small multichip module. This device processes the output of the sensors and transmits a signal that can be monitored and analyzed remotely.

Source record↗

Surface-catalyzed air oxidation of hydrazines: Environmental chamber studies

The surface-catalyzed air oxidation reactions of fuel hydrazines were studied in a 6500-liter fluorocarbon-film chamber at 80 to 100 ppm concentrations. First-order rate constants for the reactions catalyzed by aluminum, water-damaged aluminum (Al/Al2O3), stainless steel 304L, galvanized steel and titanium plates with surface areas of 2 to 24 sq m were determined. With 23.8 sq m of Al/Al2O3 the surface-catalyzed air oxidation of hydrazine had a half-life of 2 hours, diimide (N2H2) was observed as an intermediate and traces of ammonia were present in the final product mixture. The Al/Al2O3 catalyzed oxidation of monomethylhydrazine yielded methyldiazine (HN = NCH3) as an intermediate and traces of methanol. Unsymmetrical dimethylhydrazine gave no detectable products. The relative reactivities of hydrazine, MMH and UDMH were 130 : 7.3 : 1.0, respectively. The rate constants for Al/Al2O3-catalyzed oxidation of hydrazine and MMH were proportional to the square of the surface area of the plates. Mechanisms for the surface-catalyzed oxidation of hydrazine and diimide and the formation of ammonia are proposed.

Kilduff, Jan E.↗

A Review of Hydrazine Sensors: The State of the Art

Several types of sensors have been developed over the past few years that quantify the vapor concentrations of the hydrazines. These sensors are able to detect concentrations as low as 10 parts per billion (ppb) up to several parts per million (ppm). The scope of this review will be focused on those sensors that are most current in the marketplace as either leak detectors or personnel monitors. Some technical information on the theory of operations of each hydrazine detector will also be included. The review will highlight current operations that utilize hydrazine sensors including the Kennedy Space Center (KSC), the United States Air Force (USAF) at Cape Canaveral Air Station (CCAS), USAF F-16 facilities. The orientation of the review will be towards giving users usable practical information on hydrazine sensors.

Meneghelli, B. J.↗

In-situ analysis of hydrazine decomposition products

A gas analyzer utilizing a nondispersive infrared (NDIR) detection system was used to monitor the ammonia and water vapor content of the products of a previously unused hydrazine gas generator. This provided an in-situ measurement of the generator's efficiency difficult to obtain by other means. The analyzer was easily installed in both the calibration and hydrazine systems, required no maintenance other than periodic zero adjustments, and performed well for extended periods in the operating range tested. The catalyst bed operated smoothly and repeatably during the 28 hr of testing. No major transients were observed on startup or during steady state operation. The amount of ammonia in the output stream of the gas generator was found to be a strong function of temperature at catalyst bed temperatures below 450 C. At temperatures above this, the efficiency remained nearly constant. On startup the gas generator efficiency was found to decrease with time until a steady state value was attained. Elevated catalyst bed temperatures in the periods before steady state operation was found to be responsible for this phenomenon.

Curran, Francis M.↗

In-situ analysis of hydrazine decomposition products

A gas analyzer utilizing a nondispersive infrared (NDIR) detection system was used to monitor the ammonia and water vapor content of the products of a previously unused hydrazine gas generator. This provided an in-situ measurement of the generator's efficiency difficult to obtain by other means. The analyzer was easily installed in both the calibration and hydrazine systems, required no maintenance other than periodic zero adjustments, and performed well for extended periods in the operating range tested. The catalyst bed operated smoothly and repeatably during the 28 hr of testing. No major transients were observed on startup or during steady state operation. The amount of ammonia in the output stream of the gas generator was found to be a strong function of temperature at catalyst bed temperatures below 450 C. At temperatures above this, the efficiency remained nearly constant. On startup the gas generator efficiency was found to decrease with time until a steady state value was attained. Elevated catalyst bed temperatures in the periods before steady state operation was found to be responsible for this phenomenon.

Curran, Francis M.↗

Chemochromic Indicators for the Detection of Hypergolic Fuels

The toxicity and hazard level associated with the use of hypergolic fuels necessitates the development of technology capable of detecting the presence of such fuels in a variety of different environments and conditions. The most commonly used sensors for the detection of hypergolic fuels are electrochemical in nature, which have serious limitations when used as area monitoring devices. Recent collaborative work between Kennedy Space Center and ASRC Aerospace has led to the development of indicators which exhibit a color change upon exposure to hydrazine under different conditions. The indicators under investigation on this developmental effort are para-dimethylaminobenzaldehyde (PDAB), various formulations of universal pH indicators, and potassium tetrachloroaurate (KAuCl4). These chemochromic indicators have been tested for the detection of hydrazine under various conditions: pure liquid fuel, aqueous fuel solution, saline aqueous fuel solutions, vapor fuel, and 3-month shelf life study, which included UV protection, thermal extremes, and normal storage conditions. The hypergolic fuel indicator test was conducted with the indicator impregnated into a wipe material to test the applicability of the indicator to be used to capture (absorb) and indicate the presence of hypergolic fuels. Each of the indicators performed well, with the universal pH indicator being the best candidate because of the visible response color change and the indicator stability after the shelf life study.

Santiago-Maldonado, E.↗

Nano Sensors for Gas Detection in Space and Ground Support Applications

Personnel living in a space environment as well as technicians and engineers preparing spacecraft for launch can potentially be exposed to small amounts of hazardous gases. It is therefore important to be able to detect, identify and quantify the presence of a gas especially when its presence could lead to a fatal situation. The use of small and sensitive sensors can allow for the placement of these devices over a large area, thus allowing for a more precise and timely determination of a gas leak. ASRC Aerospace and its research partners are developing nano sensors for detection of various gases, including but not limited to: H2, NH3, N2O4, hydrazine and others. Initial laboratory testing has demonstrated the capability to detect the gases in concentrations lower than parts per million. Testing and development is continuing to improve the response and recovery times, to increase the sensitivity of the devices. Different coatings and electrodes are currently being evaluated to determine the optimum configuration of a variety of gases. The small footprint of the Nano sensors allows for several devices, each responsive in a different way to different gases, to be placed into a single substrate. Multiple devices embedded into a single substrate results in increased reliability and in a decrease for periodic calibrations. The use of different coatings will result in a small electronic nose capable of distinguishing between different gases. A multi-channel signal conditioner amplifier built on a small multi chip module is used to process the output of the sensors and to deliver a signal that can be remotely monitored. All the data is digitized and transmitted over the same cable pair used to power the amplifier. Multiple outputs can be connected to a single cable pair in order to minimize the added weight and expense associated with cabling in a spacecraft. The sensors will be run through a qualification process to evaluate their suitability for space applications we are expecting to have fully functional sensors available for initial field deployment and testing by the end of the year 2006.

Medelius, Pedro J.↗

A Review of Hydrazine Sensors: The State of the Art

Several types of sensors have been developed over the past few years that quantify the vapor concentrations of the hydrazines. These sensor s are able to detect concentrations as low as 10 parts per billion (ppb) up to several parts per million (ppm). The scope of this review wi ll be focused on those sensors that are most current in the marketpla ce as either leak detectors or personnel monitors. Some technical information on the theory of operations of each hydrazine detector will a lso be included. The review will highlight current operations that utilize hydrazine sensors including the Kennedy Space Center (KSC), the United States Air Force (USAF) at Cape Canaveral Air Station (CCAS), USAF F-16 facilities. The orientation of the review will be towards giving users usable practical information on hydrazine sensors.

Meneghelli, B. J.↗

Mitigating Problems in Measuring Hypergolic Fuels

To monitor hydrazine concentrations accurately and safely, hydrazine is converted into a stable derivative that will be monitored and correlated to the actual hydrazine concentration. The hydrazine's reactivity is harnessed to produce a chemical reaction that will form a stable gas-phase derivative which will not react or decompose before it reaches the detector. Hydrazine, monomethylhydrazine, and unsymmetrical dimethylhydrazine belong to a class of compounds known as hypergolic fuels. These fuels self-ignite upon mixing with hypergolic oxidizer (dinitrogen tetroxide), without need of a spark or other ignition source. The resulting reaction produces thrust with exceptionally high energy, making these compounds particularly useful as rocket propellants. Hydrazines are also highly toxic and corrosive. The combined properties of reactivity, corrosivity, and toxicity present the potential for a leak, a disastrous situation in a hypergol-loaded system. Consequently, leak detection is of the utmost importance in protecting equipment and personnel. Hydrazine vapor quantification presents many challenges in addition to the safety concerns. The reactivity of these compounds causes thermal and catalytic decomposition, which results in significant losses. Further complications arise from the sticky nature of hydrazine. Molecules adsorb irreversibly to virtually any surface they make contact with before detection, which results in instrument drift. These properties make it difficult to accurately quantify hydrazines. Current analytical methods seek to minimize these interactions. After an extensive literature search to determine appropriate chemical reactions, a method was devised to quantify hydrazines, without the limitations of monitoring hydrazines.

Source record↗

Green Applications for Space Power Project

Spacecraft propulsion and power for many decades has relied on Hydrazine monopropellant technology for auxiliary power units (APU), orbital circularization, orbit raising/lowering and attitude control. However, Hydrazine is toxic and therefore requires special ground handling procedures to ensure launch crew safety. The Swedish Company ECAPS has developed a technology based upon the propellant Ammonium Dinitramide (ADN) that offers higher performance, higher density and reduced ground handling support than Hydrazine. This blended propellant is called LMP-103S. Currently, the United States Air Force (USAF) is pursuing a technology based on Hydroxyl Ammonium Nitrate (HAN, otherwise known as AF-M315E) with industry partners Aerojet and Moog. Based on the advantages offered by these propellants, MSFC should explore powering APU's with these propellants. Due to the availability of space hardware, the principal investigator has found a collection of USAF hardware, that will act as a surrogate, which operates on a Hydrazine derivative. The F-16 fighter jet uses H-70 or 30% diluted Hydrazine for an Emergency Power Unit (EPU) which supplies power to the plane. The PI has acquired two EPU's from planes slated for destruction at the Davis Monthan AFB. This CIF will include a partnership with 2 other NASA Centers who are individually seeking seed funds from their respective organizations: Kennedy Space Center (KSC) and Dryden Flight Research Center (DFRC). KSC is preparing for future flights from their launch pads that will utilize green propellants and desire a low-cost testbed in which to test and calibrate new leak detection sensors. DFRC has access to F-16's which can be used by MSFC & KSC to perform a ground test that demonstrates emergency power supplied to the jet. Neither of the green propellant alternatives have been considered nor evaluated for an APU application. Work has already been accomplished to characterize and obtain the properties of these 2 propellants. However, the spacecraft are using existing leak detection sensors that are typically used for Hydrazine. Using these green propellants for the APU application requires decrementing their TRL down to 3. This task would aim to establish a TRL of 4 at conclusion by showing a proof of concept with a KSC-instrumented EPU asset at the MSFC Component Development Area (CDA). The task to accomplish this is called Green Application for Space Power or GRASP.

Robinson, Joel↗

A Portable Electronic Nose for Toxic Vapor Detection, Identification, and Quantification

The Space Program and military use large quantities of hydrazine and monomethyl hydrazine as rocket propellant, which are very toxic and suspected human carcinogens. Current off-the-shelf portable instruments require 10 to 20 minutes of exposure to detect these compounds at the minimum required concentrations and are prone to false positives, making them unacceptable for many operations. In addition, post-mission analyses of grab bag air samples from the Shuttle have confirmed the occasional presence of on-board volatile organic contaminants, which also need to be monitored to ensure crew safety. A new prototype instrument based on electronic nose (e-nose) technology has demonstrated the ability to qualify (identify) and quantify many of these vapors at their minimum required concentrations, and may easily be adapted to detect many other toxic vapors. To do this, it was necessary to develop algorithms to classify unknown vapors, recognize when a vapor is not any of the vapors of interest, and estimate the concentrations of the contaminants. This paper describes the design of the portable e-nose instrument, test equipment setup, test protocols, pattern recognition algorithms, concentration estimation methods, and laboratory test results.

Linnell, B. R.↗

Prototype fault isolation expert system for spacecraft control

A program which illustrates how an expert system might perform fault handling for a satellite propulsion subsystem is discussed. The program runs on a VAX 11/780 under VMS with a VT100 interface and is written in FRANZ/LISP. The program presents a series of menus to the user. Once the user selects from the menu, the program simulates the behavior of the hydrazine propulsion system under the fault condition, detects the presence of the fault, and then determines what set of actions to perform in implementing the fault workaround.

Truszkowski, Walt↗

Ozone/Ultraviolet-Photo-Oxidation Reactor

Experimental chemical-processing system destroys waste hydrazine in water by use of ozone in ultraviolet-photo-oxidation reactor. New process reduces concentrations of hydrazines and intermediate decomposition products in effluent liquid and gas to below limit of detectability. Liquid sprayed in reaction chamber past ultraviolet lamps, against flow of oxygen and ozone. Hydrazines and intermediate decomposition products oxidized to harmless substances. Effectiveness and speed of process depends on maintenance of circulating liquid at correct pH, determines lower limit of oxidation by ozone.

Swartz, Ari Ben↗

Intelligent Chemical Sensor Systems for In-space Safety Applications

Future in-space and lunar operations will require significantly improved monitoring and Integrated System Health Management (ISHM) throughout the mission. In particular, the monitoring of chemical species is an important component of an overall monitoring system for space vehicles and operations. For example, in leak monitoring of propulsion systems during launch, inspace, and on lunar surfaces, detection of low concentrations of hydrogen and other fuels is important to avoid explosive conditions that could harm personnel and damage the vehicle. Dependable vehicle operation also depends on the timely and accurate measurement of these leaks. Thus, the development of a sensor array to determine the concentration of fuels such as hydrogen, hydrocarbons, or hydrazine as well as oxygen is necessary. Work has been on-going to develop an integrated smart leak detection system based on miniaturized sensors to detect hydrogen, hydrocarbons, or hydrazine, and oxygen. The approach is to implement Microelectromechanical Systems (MEMS) based sensors incorporated with signal conditioning electronics, power, data storage, and telemetry enabling intelligent systems. The final sensor system will be self-contained with a surface area comparable to a postage stamp. This paper discusses the development of this "Lick and Stick" leak detection system and it s application to In-Space Transportation and other Exploration applications.

Hunter, G. W.↗

A Model-Based Thruster Leakage Monitor for the Cassini Spacecraft

The Cassini spacecraft was launched on October 15, 1997. It uses thrusters to perform many spacecraft control functions: to detumble the spacecraft, to maintain three-axis attitude control, to perform small trajectory correction burns, to desaturate the reaction wheels, and others.

Cassini↗

Familiarization and Detection of Green Monopropellants Project

Ammonium dinitramide (ADN) and hydroxyl ammonium nitrate (HAN) are green monopropellants which will be appearing at Kennedy Space Center (KSC) for processing in the next few years. These are relatively safe replacements for hydrazine as a monopropellant; however, little is known about methods of leak detection, vapor scrubbing, air emissions, or cleanup that will be required for safe and environmentally benign operations at KSC. The goal of this work is to develop leak detection and related technologies for the two new green monopropellants.

Technology Portfolio System↗

Familiarization and Detection of Green Monopropellants Image

Ammonium dinitramide (ADN) and hydroxyl ammonium nitrate (HAN) are green monopropellants which will be appearing at Kennedy Space Center (KSC) for processing in the next few years. These are relatively safe replacements for hydrazine as a monopropellant; however, little is known about methods of leak detection, vapor scrubbing, air emissions, or cleanup that will be required for safe and environmentally benign operations at KSC. The goal of this work is to develop leak detection and related technologies for the two new green monopropellants.

Green↗