Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometry metrology optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Wide angle astrometric demonstration on the micro-arcsecond metrology testbed for the space interferometry mission

The Space Interferometry Mission (SIM) requires fringe measurements to the level of picometers in order to produce astrometric data at the micro-arc-second level. To be more specific, it is necessary to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer to a few hundreds of picometers. The internal path is measured with a small heterodyne metrology beam, whereas the starlight fringe position is estimated with a CCD sampling a large concentric annular beam. One major challenge for SIM is to align the metrology beam with the starlight beam to keep the consistency between these two sensors at the system level while articulating the instrument optics over the field of view.

metrology↗

Measurement of the Non-common Vertex Error of a Double Corner Cube

The Space Interferometry Mission (SIM) requires the control of the optical path of each interferometer with picometer accuracy. Laser metrology gauges are used to measure the path lengths to the fiiducial corner cubes at the siderostats. Due to the geometry of SIM a single corner cube does not have sufficient acceptance angle to work with all the gauges. Therefore SIM employs a double corner cube. Current fabrication methods are in fact not capable of producing such a double corner cube with vertices having sufficient commonality. The plan for SIM is to measure the non-commonalty of the vertices and correct for the error in orbit. SIM requires that the non-common vertex error (NCVE) of the double corner cube to be less than 6 (mu)m. The required accuracy for the knowledge of the NCVE is less than 1 (mu)m. This paper explains a method of measuring non-common vertices of a brassboard double corner cube with sub-micron accuracy. The results of such a measurement will be presented.

Space Interferometry Mission (SIM)↗

LISA and LISA Pathfinder: Gravitational Wave Observation in Space

The Laser Interferometer Space Antenna (LISA) is a planned NASA-ESA gravitational wave observatory in the frequency range of 0.1 mHz--100 mHz. This observation band is inaccessible to ground-based detectors due to fluctuations in the Earth gravitational field. Gravitational wave sources for LISA include galactic binaries, mergers of supermassive black-hole binaries, extreme-mass-ratio inspirals, and cosmology backgrounds and bursts. LISA is a constellation of three spacecraft separated by 5 million km in an equilateral triangle, whose center follows the Earth in a heliocentric orbit with an orbital phase offset of 20 degrees. Challenging technology is required to ensure pure geodetic trajectories of the six onboard test masses, whose distance fluctuations will be measured by interspacecraft laser interferometers with picometer accuracy. LISA Pathfinder is an ESA-launched technology demonstration mission of key LISA subsystems such as spacecraft control with micronewton thrusters, test mass drag-free control, and precision laser interferometry between free-flying test masses. Ground testing of hardware of the Gravitational Reference Sensor and Optical Metrology subsystems of LISA Pathfinder is currently ongoing. A detailed description of the two missions and an overview of current investigations conducted by the community will be discussed. The current status in development and implementation of LISA Pathfinder pre-flight systems and latest results of the ongoing ground testing efforts will also be presented.

Guzman, Felipe↗

Extracting Zero-Gravity Surface Figure of a Mirror

The technical innovation involves refinement of the classic optical technique of averaging surface measurements made in different orientations with respect to gravity, so the effects of gravity cancel in the averaged image. Particularly for large, thin mirrors subject to substantial deformation, the further requirement is that mount forces must also cancel when averaged over measurement orientations. The zerogravity surface figure of a mirror in a hexapod mount is obtained by analyzing the summation of mount forces in the frame of the optic as surface metrology is averaged over multiple clockings. This is illustrated with measurements taken from the Space Interferometry Mission (SIM) PT-Ml mirror for both twofold and threefold clocking. The positive results of these measurements and analyses indicate that, from this perspective, a lighter mirror could be used; that is, one might place less reliance on the damping effects of the elliptic partial differential equations that describe the propagation of forces through glass. The advantage over prior art is relaxing the need for an otherwise substantial thickness of glass that might be needed to ensure accurate metrology in the absence of a detailed understanding and analysis of the mount forces. The general insights developed here are new, and provide the basic design principles on which mirror mount geometry may be chosen.

Bloemhof, Eric E.↗

Laser Interferometry for Gravitational Wave Observation: LISA and LISA Pathfinder

The Laser Interferometer Space Antenna (LISA) is a planned NASA-ESA gravitational wave observatory in the frequency range of 0.1mHz-100mHz. This observation band is inaccessible to ground-based detectors due to the large ground motions of the Earth. Gravitational wave sources for LISA include galactic binaries, mergers of supermasive black-hole binaries, extreme-mass-ratio inspirals, and possibly from as yet unimagined sources. LISA is a constellation of three spacecraft separated by 5 million km in an equilateral triangle, whose center follows the Earth in a heliocentric orbit with an orbital phase offset oF 20 degrees. Challenging technology is required to ensure pure geodetic trajectories of the six onboard test masses, whose distance fluctuations will be measured by interspacecraft laser interferometers with picometer accuracy. LISA Pathfinder is an ESA-launched technology demonstration mission of key LISA subsystems such us spacecraft control with micro-newton thrusters, test mass drag-free control, and precision laser interferometry between free-flying test masses. Ground testing of flight hardware of the Gravitational Reference Sensor and Optical Metrology subsystems of LISA Pathfinder is currently ongoing. An introduction to laser interferometric gravitational wave detection, ground-based observatories, and a detailed description of the two missions together with an overview of current investigations conducted by the community will bc discussed. The current status in development and implementation of LISA Pathfinder pre-flight systems and latest results of the ongoing ground testing efforts will also be presented

Guzman, Felipe↗

Results from the TOM3 testbed: thermal deformation of optics at the picometer Level

We have discussed the TOM3 testbed developed to assess the thermo-opto-mechanical stability of optical assembly such as SIM's siderostat and telescope in flight-like thermal conditions. Although limited by the metrology sensor noise, test results show that optical wavefront stability of SIM's optical assembly is compatible with single micro-arcsecond astrometry.

Space Interferometer Mission (SIM)↗

Performance of the Primary Mirror Center-of-curvature Optical Metrology System During Cryogenic Testing of the JWST Pathfinder Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius-of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse & fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment & phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development & spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software & procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate & efficient cryogenic testing of the JWST flight telescope.

optical testing↗

Sub-pixel Spatial Resolution Micro-roughness Measurements with Interlaced Stitching

In this paper we describe a method to increase the spatial resolution of surface micro-roughness measurements. As the surface specifications for precision optics become more demanding, the metrology instruments must cover a broad spatial frequency range. Generally, multiple instruments are used to cover the full range of the specifications. For example, a Fizeau interferometer would be used to test low spatial frequency surface errors, a white light interferometer would be used for mid spatial frequency errors, and an AFM would be used for high spatial frequency errors. For some precision optics, three instruments would be necessary. However, in many applications, an increase in the spatial resolution of a metrology instrument could negate the need for multiple instruments. A solution to increase the spatial resolution of micro-roughness measurements obtained using white light interferometry with "interlaced stitching" will be presented. In "interlaced stitching", multiple interferometric measurements are made as the optic under test (or the CCD array) is laterally shifted at sub-pixel increments. The measurements are then combined to construct a measurement with higher spatial resolution. Initial results obtained while implementing a similar process used to increase the spatial resolution of measurements made with a commercially available Fizeau interferometer will be presented.

Mooney, James T.↗

A Photonic Clockwork for Deployed Timing and Radar

We present an environmentally robust photonic RF/microwave clockwork with low size, weight, and power (SWaP) for next-generation, field-deployable timing and radar applications. Compared to microwave references, optical local oscillators offer superior fractional frequency stability and phase-noise performance. When transferred with high fidelity into the RF/microwave domain, this “optical advantage” promises unparalleled performance across both private-industry and government (e.g., defense and space-agency) applications including very-long-baseline interferometry (VLBI), alternative positioning, navigation, and timing (PNT), multi-static synthetic aperture radar (MSAR), and geodetic sensing. However, this potential has yet to be fully realized outside the metrology lab primarily due to the high-SWaP and excessive environmental susceptibility of both the optical reference itself as well as the optical frequency comb (OFC) required to transfer the optical stability into the RF/microwave domain. Here, we present two demonstrations of a low-SWaP, environmentally robust photonic clockwork used to make a high-fidelity optical-microwave link with the stability and phase-noise performance relevant to the applications described above. Additionally, operational-testing results of the OFC subsystem under application-relevant environmental conditions will be presented to show pathway to field deployment of this critical subsystem.

Guangning Yang↗

Performance of the Center-Of-Curvature Optical Assembly During Cryogenic Testing of the James Webb Space Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 meters in diameter and consists of 18 hexagonal segments, each 1.5 meters point-to-point. Each segment has a 6 degree-of-freedom hexapod actuation system and a radius-of-curvature (ROC) actuation system. The full telescope was tested at its cryogenic operating temperature at Johnson Space Center (JSC) in 2017. This testing included center-of-curvature measurements of the PM wavefront error using the Center-of-Curvature Optical Assembly (COCOA), along with the Absolute Distance Meter Assembly (ADMA). The COCOA included an interferometer, a reflective null, an interferometer-null calibration system, coarse and fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer was used to enable alignment and phasing of the PM segments. By combining measurements at two laser wavelengths, synthetic wavelengths up to 15 millimeters could be achieved, allowing mirror segments with millimeter-level piston errors to be phased to the nanometer level. The ADMA was used to measure and set the spacing between the PM and the focus of the COCOA null (i.e., the PM center-of-curvature) for determination of the ROC. This paper describes the COCOA, the PM test setup, the testing performed, the test results, and the performance of the COCOA in aligning & phasing the PM segments and measuring the final PM wavefront error.

JWST↗

Design considerations and validation of the MSTAR absolute metrology system

Absolute metrology measures the actual distance between two optical fiducials. A number of methods have been employed, including pulsed time-of-flight, intensity-modulated optical beam, and two-color interferometry. The rms accuracy is currently limited to -5 microns. Resolving the integer number of wavelengths requires a 1-sigma range accuracy of -0.1 microns. Closing this gap has a large pay-off the range (length measurement) accuracy can be increased substantially using the unambiguous optical phase. The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. In this paper, we present recent experiments that use dispersed white light interferometry to independently validate the zero-point of the system. We also describe progress towards reducing the size of optics, and stabilizing the laser wavelength for operation over larger target ranges. MSTAR is a general-purpose tool for conveniently measuring length with much greater accuracy than was previously possible, and has a wide range of possible applications.

Jeganathan, Muthu↗

Estimation of cyclic error due to scattering in the internal OPD metrology of the Space Interferometry Mission

A common-path laser heterodyne interferometer capable of measuring the internal OPD with accuracy of the order of 10 picometers was demonstrated at JPL. To achieve this accuracy, the relative power received by the detector that is contributed by the scattering of light at the optical surfaces should be less than -97 dB. A method has been developed to estimate the cyclic error caused by the scattering of the optical surfaces. The result of the analysis is presented.

Zhao, Feng↗